Using ReadVarsESO[LINK]
Creating
Charts and Spreadsheet files from Output Variables[LINK]
The ReadVarsESO program is distributed with EnergyPlus as a
simple approach to converting the standard output files
(eplusout.eso, eplusout.mtr) into files that
can be put directly into a spreadsheet program and then used
to create graphs or do other statistical operations.
ReadVarsESO can read the complex output files and sort the
data into time-based form, it is a very quick application but
does not have a lot of features. Note that all the Output:Meter
and Output:Meter:Cumulative
objects are included on the eplusout.eso file
as well as the eplusout.mtr file. You can
choose the Output:Meter:MeterFileOnly
or Output:Meter:Cumulative:MeterFileOnly
objects if you do not want a particular meter to show up on
the eplusout.eso file. If you wish to see
only the metered outputs, the eplusout.mtr
file will typically be a lot smaller than the
eplusout.eso file.
The ReadVarsESO program has a very simple set of inputs. By
default, you will get all the variables listed in the [Output:Variable](../input-output-reference/page-089.html#outputvariable)
(eplusout.eso) or [Output:Meter](../input-output-reference/page-089.html#outputmeter-and-outputmetermeterfileonly)
(eplusout.mtr) objects into the appropriate
output files. The outputs from ReadVarsESO are limited to 255
variables (Microsoft Excel™ limit). You can tailor how many
variables to list by specifying variables for the ReadVarsESO
runs.
You can override the 255 variable limit by specifying an
argument on the command line (EP-Launch has a
special option for this). You use “unlimited” or “nolimit” on
the command line to get as many variables into your output
file as desired. Again, this will be limited either by the
number of variables in the eplusout.eso or
eplusout.mtr files or the contents of the
“rvi” file. If you want to use this option, you must include
two arguments to the command line of the ReadVars program – 1)
the “rvi” file and 2) the “unlimited” argument.
ReadVarsESO Command Line Options
| Option |
Description |
|
To use any of these options, you
must include a file name (“rvi” file) as the first
argument. |
| Unlimited (or Nolimit) |
Variables of any number will be
produced on the output file. |
| Timestep |
Only variables with reported
frequency “timestep” (or detailed) will be produced on the
output file. |
| Hourly |
Only variables with reported
frequency “hourly” will be produced on the output file. |
| Daily |
Only variables with reported
frequency “daily” will be produced on the output file. |
| Monthly |
Only variables with reported
frequency “monthly” will be produced on the output file. |
| Annual (or RunPeriod) |
Only variables with reported
frequency “runperiod” will be produced on the output
file. |
In addition, another argument can be used so that the
output file is only one time frequency. (By default, all
variables – hourly, monthly, annual, etc. are mixed together
in the output file). By using “[Timestep](../input-output-reference/page-006.html#timestep)”
as an argument, you would get only the TimeStep reported
variables. Using “Monthly”, only the monthly variables. This
is not automated in either EP-Launch or the
RunEPlus batch file but can easily be
accomplished.
The program is run automatically from the
EP-Launch program or the
RunEPlus batch file (both these methods for
executing EnergyPlus are described in the GettingStarted
document). These programs use .rvi for input
to the ReadVarsESO program executed first after the EnergyPlus
execution and .mvi for the second execution.
Ostensibly, the .rvi file would apply to the eplusout.eso file
and the .mvi would apply to the eplusout.mtr file, BUT the
contents of the files actually specify the
“input” reporting file and the
“output” reorganized file. Typical contents
of an .rvi file are:
“RVI” file contents
| .rvi line description |
Actual .rvi File Contents |
| Input File |
eplusout.eso |
| Output File |
eplusout.csv |
| Variable Name |
Site Outdoor Drybulb
Temperature |
| Variable Name |
Zone Air Temperature |
| Variable Name |
Zone Air Humidity Ratio |
| Variable Name |
Zone Air System Sensible Cooling
Rate |
| Variable Name |
Zone Air System Sensible Heating
Rate |
| Variable Name |
Zone Total Internal Latent Gain
Rate |
| Specific Variable Name |
COOLING COIL AIR OUTLET
NODE,System Node Temperature |
| Specific Variable Name |
AIR LOOP OUTLET NODE,System Node
Temperature |
| Specific Variable Name |
AIR LOOP OUTLET NODE,System Node
Humidity Ratio |
| Specific Variable Name |
Mixed Air Node,System Node Mass
Flow Rate |
| Specific Variable Name |
Outdoor air Inlet Node,System
Node Mass Flow Rate |
| Variable Name |
Humidifier Water Consumption
Rate |
| Variable Name |
Humidifier Electric Power |
| Variable Name |
Zone Air Relative Humidity |
| Variable Name |
Zone Predicted Moisture Load
Moisture Transfer Rate |
| Termination Line (optional) |
0 |
Note that the first two lines of the file are “input file”
(where to read the output variable values from) and “output
file” (where to put the reorganized data). If you have only
those two lines in an “rvi” file, the program will use all the
available variables on indicated input file to produce the
output.
ReadVarsESO takes the input stream but recognizes the
date/time information and appropriately places the required
data onto the “output file”. Following these lines are a list
of variables to be culled from the “input file” and placed
onto the output file. “Variable Name” will take all variables
matching that description whereas “Specific Variable Name”
will only match the full description of the variable. So, in
the above example, “[Zone](../input-output-reference/page-011.html#zone)
Air Temperature” will report air temperatures for all the
zones (but available at the HVAC timestep if you choose the
“detailed” reporting frequency in your input file) but “AIR
LOOP OUTLET NODE” and “COOLING COIL AIR OUTLET NODE” will be
the only values reported for the “System Node Temperature”
variable (the node temperature is available for all nodes used
in the simulation). The termination line (0) is included to
terminate the input to the ReadVarsESO program and begin the
scanning.
The output from ReadVarsESO is in the form commonly called
“comma de-limited” or “comma separated variable”. This format
can be read easily in spreadsheet programs, such as
Excel™.
Note as described in the “Input for Output” above, only
variables as listed on the eplusout.rdd file
are available for reporting. If you request others, they will
become “Warning” messages in the eplusout.err
file.
** Warning ** The following Output variables were requested but not generated
** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file
************* Key=*, VarName=SYSTEM SENSIBLE COOLING RATE
The above message was generated from an IDF that requested
reporting of the “SYSTEM SENSIBLE COOLING RATE” but that
variable was not available from the components in the
execution.
Example ReadVarsESO command lines and
results
| Command Line |
Description/Result |
| ReadVarsESO |
Take eplusout.eso and produce an
eplusout.csv file with all variables (up to 255) on it |
| ReadVarsESO my.rvi |
Use the contents of “my.rvi” to
produce the appropriate output file (limited to 255
variables) |
| ReadVarsESO my.rvi
unlimited |
Use the contents of “my.rvi” to
produce the appropriate output file (no longer limited to 255
variables) |
| ReadVarsESO my.rvi Monthly |
Use the contents of “my.rvi” to
produce the appropriate output file and only produce those
variables reported for “monthly” frequency (up to 255
variables) |
| ReadVarsESO my.rvi Daily
unlimited |
Use the contents of “my.rvi” to
produce the appropriate output file and only produce those
variables reported for “daily” frequency (no longer limited to
255 variables) |
Using ReadVarsESO[LINK]
Creating Charts and Spreadsheet files from Output Variables[LINK]
The ReadVarsESO program is distributed with EnergyPlus as a simple approach to converting the standard output files (eplusout.eso, eplusout.mtr) into files that can be put directly into a spreadsheet program and then used to create graphs or do other statistical operations. ReadVarsESO can read the complex output files and sort the data into time-based form, it is a very quick application but does not have a lot of features. Note that all the Output:Meter and Output:Meter:Cumulative objects are included on the eplusout.eso file as well as the eplusout.mtr file. You can choose the Output:Meter:MeterFileOnly or Output:Meter:Cumulative:MeterFileOnly objects if you do not want a particular meter to show up on the eplusout.eso file. If you wish to see only the metered outputs, the eplusout.mtr file will typically be a lot smaller than the eplusout.eso file.
The ReadVarsESO program has a very simple set of inputs. By default, you will get all the variables listed in the [Output:Variable](../input-output-reference/page-089.html#outputvariable) (eplusout.eso) or [Output:Meter](../input-output-reference/page-089.html#outputmeter-and-outputmetermeterfileonly) (eplusout.mtr) objects into the appropriate output files. The outputs from ReadVarsESO are limited to 255 variables (Microsoft Excel™ limit). You can tailor how many variables to list by specifying variables for the ReadVarsESO runs.
You can override the 255 variable limit by specifying an argument on the command line (EP-Launch has a special option for this). You use “unlimited” or “nolimit” on the command line to get as many variables into your output file as desired. Again, this will be limited either by the number of variables in the eplusout.eso or eplusout.mtr files or the contents of the “rvi” file. If you want to use this option, you must include two arguments to the command line of the ReadVars program – 1) the “rvi” file and 2) the “unlimited” argument.
In addition, another argument can be used so that the output file is only one time frequency. (By default, all variables – hourly, monthly, annual, etc. are mixed together in the output file). By using “[Timestep](../input-output-reference/page-006.html#timestep)” as an argument, you would get only the TimeStep reported variables. Using “Monthly”, only the monthly variables. This is not automated in either EP-Launch or the RunEPlus batch file but can easily be accomplished.
The program is run automatically from the EP-Launch program or the RunEPlus batch file (both these methods for executing EnergyPlus are described in the GettingStarted document). These programs use .rvi for input to the ReadVarsESO program executed first after the EnergyPlus execution and .mvi for the second execution. Ostensibly, the .rvi file would apply to the eplusout.eso file and the .mvi would apply to the eplusout.mtr file, BUT the contents of the files actually specify the “input” reporting file and the “output” reorganized file. Typical contents of an .rvi file are:
Note that the first two lines of the file are “input file” (where to read the output variable values from) and “output file” (where to put the reorganized data). If you have only those two lines in an “rvi” file, the program will use all the available variables on indicated input file to produce the output.
ReadVarsESO takes the input stream but recognizes the date/time information and appropriately places the required data onto the “output file”. Following these lines are a list of variables to be culled from the “input file” and placed onto the output file. “Variable Name” will take all variables matching that description whereas “Specific Variable Name” will only match the full description of the variable. So, in the above example, “[Zone](../input-output-reference/page-011.html#zone) Air Temperature” will report air temperatures for all the zones (but available at the HVAC timestep if you choose the “detailed” reporting frequency in your input file) but “AIR LOOP OUTLET NODE” and “COOLING COIL AIR OUTLET NODE” will be the only values reported for the “System Node Temperature” variable (the node temperature is available for all nodes used in the simulation). The termination line (0) is included to terminate the input to the ReadVarsESO program and begin the scanning.
The output from ReadVarsESO is in the form commonly called “comma de-limited” or “comma separated variable”. This format can be read easily in spreadsheet programs, such as Excel™.
Note as described in the “Input for Output” above, only variables as listed on the eplusout.rdd file are available for reporting. If you request others, they will become “Warning” messages in the eplusout.err file.
The above message was generated from an IDF that requested reporting of the “SYSTEM SENSIBLE COOLING RATE” but that variable was not available from the components in the execution.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.