Missing Weather File
Data[LINK]
The following data contains “missing” descriptors; a new
concept not introduced previously in our IDD conventions. In
this case, it will be processed as though those values are
“missing” in the weather conversions. This may not always be
desirable though the weather processor will fill in “missing”
value with something “appropriate”. Eventually, these missing
values will be available through the weather processor. Until
then, the following are used for initial missing conditions.
When a valid value is encountered from weather data, however,
it will become the new “missing” replacement value:
Missing weather replacement values
| Data item |
Supplied
Value |
Units |
| Dry Bulb Temperature |
6 |
C |
| Dew Point Temperature |
3 |
C |
| Relative Humidity |
50 |
% |
| Atmospheric Pressure |
Standard** Barometric Pressure
(altitude based) |
Pa |
| Wind Speed |
2.5 |
m/s |
| Wind Direction |
180 |
Deg |
| Total Sky Cover |
5 |
(tenths) |
| Opaque Sky Cover |
5 |
(tenths) |
| Visibility |
777.7 |
Km |
| Ceiling Height |
77777 |
m |
| Precipitable Water |
0 |
Mm |
| Aerosol Optical Depth |
0 |
Broadband turbidity |
| Snow Depth |
0 |
Cm |
| Days Since Last Snow |
88 |
Days |
| Radiation Values
(Direct/Diffuse) |
0.0 |
Wh/m2 |
| Illuminance Values |
0.0 |
lux (or CD/m2) |
**Standard Barometric pressure based on location elevation
is taken from ASHRAE 2001 Handbook of Fundamentals, pages 6.1
& 6.2.
Missing Weather File Data[LINK]
The following data contains “missing” descriptors; a new concept not introduced previously in our IDD conventions. In this case, it will be processed as though those values are “missing” in the weather conversions. This may not always be desirable though the weather processor will fill in “missing” value with something “appropriate”. Eventually, these missing values will be available through the weather processor. Until then, the following are used for initial missing conditions. When a valid value is encountered from weather data, however, it will become the new “missing” replacement value:
**Standard Barometric pressure based on location elevation is taken from ASHRAE 2001 Handbook of Fundamentals, pages 6.1 & 6.2.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.