Guide for Interface Developers — EnergyPlus 8.2

<< Prev | Table of Contents | Object Index | Next >>

Appendix A. Simple IDF file[LINK]

    !1ZoneUncontrolled.idf
    ! Basic file description:  Basic test for EnergyPlus.  Resistive Walls.  Regular (no ground contact) floor.
    !                          Regular roof.  No Windows.
    !
    ! Highlights:              Very basic test to see that EnergyPlus "works".
    !
    !
    ! Simulation Location/Run: DENVER_STAPLETON_CO_USA_WMO_724690, 2 design days, 1 run period,
    !                          Run Control executes two design days (see RUN PERIOD object)
    !
    ! Location:                Denver, CO
    !
    ! Design Days:             DENVER_STAPLETON_CO_USA Annual Heating 99%, MaxDB=-16°C
    !                          DENVER_STAPLETON_CO_USA Annual Cooling (DB=>MWB) 1%, MaxDB=32.6°C MWB=15.5°C
    !
    ! Run Period (Weather File): Full Annual Simulation, DENVER_STAPLETON_CO_USA_WMO_724690
    !
    ! Run Control:             No zone or system sizing, design day run control (no weather file simulation)
    !
    ! Building: Fictional 1 zone building with resistive walls.
    !
    !           The building is oriented due north.
    !
    ! Floor Area:        232.25 m2
    ! Number of Stories: 1
    !
    ! Zone Description Details:
    !
    !       (0,15.24,0)                 (15.24,15.24,0)
    !              _____________________________
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |                             |
    !             |_____________________________|
    !
    !          (0,0,0)                      (15.24,0,0)
    !
    ! Internal gains description:     NA
    !
    ! Interzone Surfaces:             None
    ! Internal Mass:                  None
    ! People:                         None
    ! Lights:                         None
    ! Equipment:                      None
    ! Windows:                        0
    ! Detached Shading:               None
    ! Daylight:                       None
    ! Natural Ventilation:            None
    ! Compact Schedules:              NA (Example of non-Compact Schedules)
    ! Solar Distribution:             MinimalShadowing
    !
    ! HVAC:                           NA
    !
    ! Zonal Equipment:                NA
    ! Central Air Handling Equipment: No
    ! System Equipment Autosize:      No
    ! Purchased Cooling:              No
    ! Purchased Heating:              No
    ! Purchased Chilled Water:        No
    ! Purchased Hot Water:            No
    ! Coils:                          None
    ! Pumps:                          None
    ! Boilers:                        None
    ! Chillers:                       None
    ! Towers:                         None
    !
    ! Results:
    ! Standard Reports:               Variable Dictionary, Surfaces (dxf-wireframe), Meter File
    ! Timestep or Hourly Variables:   Hourly and Daily
    ! Time bins Report:               None
    ! HTML Report:                    None
    ! Environmental Emissions:        None
    ! Utility Tariffs:                None

      Output:PreprocessorMessage,
        No Preprocessor Used,    !- Preprocessor Name
        Information,             !- Error Severity
        Illustrative Message,    !- Message Line 1
        No problems for processing;  !- Message Line 2

      Version,
        3.0;                     !- Version Identifier

      Timestep,
        4;                       !- Number of Timesteps per Hour

      Building,
        Simple One Zone (Wireframe DXF),  !- Name
        0.0000000E+00,           !- North Axis {deg}
        Suburbs,                 !- Terrain
        .04,                     !- Loads Convergence Tolerance Value
        .004,                    !- Temperature Convergence Tolerance Value {deltaC}
        MinimalShadowing,        !- Solar Distribution
        30;                      !- Maximum Number of Warmup Days

      HeatBalanceAlgorithm,
        ConductionTransferFunction;  !- Algorithm

      SurfaceConvectionAlgorithm:Inside,
        Detailed;                !- Algorithm

      SurfaceConvectionAlgorithm:Outside,
        Detailed;                !- Algorithm

      SimulationControl,
        No,                      !- Do Zone Sizing Calculation
        No,                      !- Do System Sizing Calculation
        No,                      !- Do Plant Sizing Calculation
        Yes,                     !- Run Simulation for Sizing Periods
        Yes;                     !- Run Simulation for Weather File Run Periods

      RunPeriod,
        1,                       !- Begin Month
        1,                       !- Begin Day of Month
        12,                      !- End Month
        31,                      !- End Day of Month
        Tuesday,                 !- Day of Week for Start Day
        Yes,                     !- Use Weather File Holidays and Special Days
        Yes,                     !- Use Weather File Daylight Saving Period
        No,                      !- Apply Weekend Holiday Rule
        Yes,                     !- Use Weather File Rain Indicators
        Yes;                     !- Use Weather File Snow Indicators

      Site:Location,
        DENVER_STAPLETON_CO_USA_WMO_724690,  !- Name
        39.77,                   !- Latitude {deg}
        -104.87,                 !- Longitude {deg}
        -7.00,                   !- Time Zone {hr}
        1611.00;                 !- Elevation {m}

     !  WMO=724690 Time Zone=NAM        (GMT-07:00) Mountain Time (US & Canada)
     !  Data Source=ASHRAE 2005 Annual Design Conditions
     ! Using Design Conditions from "Climate Design Data 2005 ASHRAE Handbook"
     ! DENVER_STAPLETON_CO_USA Extreme Annual Wind Speeds, 1%=10.9m/s, 2.5%=8.8m/s, 5%=7.7m/s
     ! DENVER_STAPLETON_CO_USA Extreme Annual Temperatures, Max Drybulb=37.2°C Min Drybulb=-24.6°C
     ! DENVER_STAPLETON_CO_USA Annual Heating Design Conditions Wind Speed=2.3m/s Wind Dir=180
     ! Coldest Month=December
     ! DENVER_STAPLETON_CO_USA Annual Heating 99%, MaxDB=-16°C

      SizingPeriod:DesignDay,
        DENVER_STAPLETON Ann Htg 99% Condns DB,  !- Name
        -16,                     !- Maximum Dry-Bulb Temperature {C}
        0.0,                     !- Daily Temperature Range {deltaC}
        -16,                     !- Humidity Indicating Conditions at Maximum Dry-Bulb
        83411.,                  !- Barometric Pressure {Pa}
        2.3,                     !- Wind Speed {m/s}
        180,                     !- Wind Direction {deg}
        0.00,                    !- Sky Clearness
        0,                       !- Rain Indicator
        0,                       !- Snow Indicator
        21,                      !- Day of Month
        12,                      !- Month
        WinterDesignDay,         !- Day Type
        0,                       !- Daylight Saving Time Indicator
        WetBulb;                 !- Humidity Indicating Type

     ! DENVER_STAPLETON Annual Cooling Design Conditions Wind Speed=4m/s Wind Dir=120
     ! Hottest Month=July
     ! DENVER_STAPLETON_CO_USA Annual Cooling (DB=>MWB) 1%, MaxDB=32.6°C MWB=15.5°C

      SizingPeriod:DesignDay,
        DENVER_STAPLETON Ann Clg 1% Condns DB=>MWB,  !- Name
        32.6,                    !- Maximum Dry-Bulb Temperature {C}
        15.2,                    !- Daily Temperature Range {deltaC}
        15.5,                    !- Humidity Indicating Conditions at Maximum Dry-Bulb
        83411.,                  !- Barometric Pressure {Pa}
        4,                       !- Wind Speed {m/s}
        120,                     !- Wind Direction {deg}
        1.00,                    !- Sky Clearness
        0,                       !- Rain Indicator
        0,                       !- Snow Indicator
        21,                      !- Day of Month
        7,                       !- Month
        SummerDesignDay,         !- Day Type
        0,                       !- Daylight Saving Time Indicator
        WetBulb;                 !- Humidity Indicating Type

      Material:NoMass,
        R13LAYER,                !- Name
        Rough,                   !- Roughness
        2.290965,                !- Thermal Resistance {m2-K/W}
        0.9000000,               !- Thermal Absorptance
        0.7500000,               !- Solar Absorptance
        0.7500000;               !- Visible Absorptance

      Material:NoMass,
        R31LAYER,                !- Name
        Rough,                   !- Roughness
        5.456,                   !- Thermal Resistance {m2-K/W}
        0.9000000,               !- Thermal Absorptance
        0.7500000,               !- Solar Absorptance
        0.7500000;               !- Visible Absorptance

      Material,
        C5 - 4 IN HW CONCRETE,   !- Name
        MediumRough,             !- Roughness
        0.1014984,               !- Thickness {m}
        1.729577,                !- Conductivity {W/m-K}
        2242.585,                !- Density {kg/m3}
        836.8000,                !- Specific Heat {J/kg-K}
        0.9000000,               !- Thermal Absorptance
        0.6500000,               !- Solar Absorptance
        0.6500000;               !- Visible Absorptance

      Construction,
        R13WALL,                 !- Name
        R13LAYER;                !- Outside Layer

      Construction,
        FLOOR,                   !- Name
        C5 - 4 IN HW CONCRETE;   !- Outside Layer

      Construction,
        ROOF31,                  !- Name
        R31LAYER;                !- Outside Layer

      Site:GroundTemperature:BuildingSurface,
        18.89,                   !- January Ground Temperature {C}
        18.92,                   !- February Ground Temperature {C}
        19.02,                   !- March Ground Temperature {C}
        19.12,                   !- April Ground Temperature {C}
        19.21,                   !- May Ground Temperature {C}
        19.23,                   !- June Ground Temperature {C}
        19.07,                   !- July Ground Temperature {C}
        19.32,                   !- August Ground Temperature {C}
        19.09,                   !- September Ground Temperature {C}
        19.21,                   !- October Ground Temperature {C}
        19.13,                   !- November Ground Temperature {C}
        18.96;                   !- December Ground Temperature {C}

      Zone,
        ZONE ONE,                !- Name
        0.0000000E+00,           !- Direction of Relative North {deg}
        0.0000000E+00,           !- X Origin {m}
        0.0000000E+00,           !- Y Origin {m}
        0.0000000E+00,           !- Z Origin {m}
        1,                       !- Type
        1,                       !- Multiplier
        autocalculate,           !- Ceiling Height {m}
        autocalculate;           !- Volume {m3}

      ScheduleTypeLimits,
        Fraction,                !- Name
        0.0 : 1.0,               !- Range
        CONTINUOUS;              !- Numeric Type

      GlobalGeometryRules,
        UpperLeftCorner,         !- Starting Vertex Position
        CounterClockWise,        !- Vertex Entry Direction
        WorldCoordinateSystem;   !- Coordinate System

      BuildingSurface:Detailed,
        Zn001:Wall001,           !- Name
        Wall,                    !- Surface Type
        R13WALL,                 !- Construction Name
        ZONE ONE,                !- Zone Name
        Outdoors,                !- Outside Boundary Condition
        ,                        !- Outside Boundary Condition Object
        SunExposed,              !- Sun Exposure
        WindExposed,             !- Wind Exposure
        0.5000000,               !- View Factor to Ground
        4,                       !- Number of Vertices
        0.0000000E+00,0.0000000E+00,4.572000,  !- X,Y,Z ==> Vertex 1
        0.0000000E+00,0.0000000E+00,0.0000000E+00,  !- X,Y,Z ==> Vertex 2
        15.24000,0.0000000E+00,0.0000000E+00,  !- X,Y,Z ==> Vertex 3
        15.24000,0.0000000E+00,4.572000;  !- X,Y,Z ==> Vertex 4

      BuildingSurface:Detailed,
        Zn001:Wall002,           !- Name
        Wall,                    !- Surface Type
        R13WALL,                 !- Construction Name
        ZONE ONE,                !- Zone Name
        Outdoors,                !- Outside Boundary Condition
        ,                        !- Outside Boundary Condition Object
        SunExposed,              !- Sun Exposure
        WindExposed,             !- Wind Exposure
        0.5000000,               !- View Factor to Ground
        4,                       !- Number of Vertices
        15.24000,0.0000000E+00,4.572000,  !- X,Y,Z ==> Vertex 1
        15.24000,0.0000000E+00,0.0000000E+00,  !- X,Y,Z ==> Vertex 2
        15.24000,15.24000,0.0000000E+00,  !- X,Y,Z ==> Vertex 3
        15.24000,15.24000,4.572000;  !- X,Y,Z ==> Vertex 4

      BuildingSurface:Detailed,
        Zn001:Wall003,           !- Name
        Wall,                    !- Surface Type
        R13WALL,                 !- Construction Name
        ZONE ONE,                !- Zone Name
        Outdoors,                !- Outside Boundary Condition
        ,                        !- Outside Boundary Condition Object
        SunExposed,              !- Sun Exposure
        WindExposed,             !- Wind Exposure
        0.5000000,               !- View Factor to Ground
        4,                       !- Number of Vertices
        15.24000,15.24000,4.572000,  !- X,Y,Z ==> Vertex 1
        15.24000,15.24000,0.0000000E+00,  !- X,Y,Z ==> Vertex 2
        0.0000000E+00,15.24000,0.0000000E+00,  !- X,Y,Z ==> Vertex 3
        0.0000000E+00,15.24000,4.572000;  !- X,Y,Z ==> Vertex 4

      BuildingSurface:Detailed,
        Zn001:Wall004,           !- Name
        Wall,                    !- Surface Type
        R13WALL,                 !- Construction Name
        ZONE ONE,                !- Zone Name
        Outdoors,                !- Outside Boundary Condition
        ,                        !- Outside Boundary Condition Object
        SunExposed,              !- Sun Exposure
        WindExposed,             !- Wind Exposure
        0.5000000,               !- View Factor to Ground
        4,                       !- Number of Vertices
        0.0000000E+00,15.24000,4.572000,  !- X,Y,Z ==> Vertex 1
        0.0000000E+00,15.24000,0.0000000E+00,  !- X,Y,Z ==> Vertex 2
        0.0000000E+00,0.0000000E+00,0.0000000E+00,  !- X,Y,Z ==> Vertex 3
        0.0000000E+00,0.0000000E+00,4.572000;  !- X,Y,Z ==> Vertex 4

      BuildingSurface:Detailed,
        Zn001:Flr001,            !- Name
        Floor,                   !- Surface Type
        FLOOR,                   !- Construction Name
        ZONE ONE,                !- Zone Name
        Surface,                 !- Outside Boundary Condition
        Zn001:Flr001,            !- Outside Boundary Condition Object
        NoSun,                   !- Sun Exposure
        NoWind,                  !- Wind Exposure
        1.000000,                !- View Factor to Ground
        4,                       !- Number of Vertices
        15.24000,0.000000,0.0,  !- X,Y,Z ==> Vertex 1
        0.000000,0.000000,0.0,  !- X,Y,Z ==> Vertex 2
        0.000000,15.24000,0.0,  !- X,Y,Z ==> Vertex 3
        15.24000,15.24000,0.0;  !- X,Y,Z ==> Vertex 4

      BuildingSurface:Detailed,
        Zn001:Roof001,           !- Name
        Roof,                    !- Surface Type
        ROOF31,                  !- Construction Name
        ZONE ONE,                !- Zone Name
        Outdoors,                !- Outside Boundary Condition
        ,                        !- Outside Boundary Condition Object
        SunExposed,              !- Sun Exposure
        WindExposed,             !- Wind Exposure
        0.0000000E+00,           !- View Factor to Ground
        4,                       !- Number of Vertices
        0.000000,15.24000,4.572,  !- X,Y,Z ==> Vertex 1
        0.000000,0.000000,4.572,  !- X,Y,Z ==> Vertex 2
        15.24000,0.000000,4.572,  !- X,Y,Z ==> Vertex 3
        15.24000,15.24000,4.572;  !- X,Y,Z ==> Vertex 4

      Output:Variable,
        *,                       !- Key Value
        outdoor dry bulb,        !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Daylight Saving Time Indicator,  !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        DayType Index,           !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Zone Mean Air Temperature,  !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Zone Total Internal Latent Gain,  !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Zone Mean Radiant Temperature,  !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Zone Air Balance Surface Convection Rate,  !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Zone Air Balance Air Energy Storage Rate,  !- Variable Name
        hourly;                  !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Surface Inside Temperature,  !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Surface Outside Temperature,  !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Surface Int Convection Coeff,  !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Variable,
        *,                       !- Key Value
        Surface Ext Convection Coeff,  !- Variable Name
        daily;                   !- Reporting Frequency

      Output:Reports,
        VariableDictionary,      !- Type of Report
        IDF;                     !- Report Name

      Output:Reports,
        surfaces,                !- Type of Report
        dxf:wireframe;           !- Report Name

      Output:Reports,
        construction;            !- Type of Report

      Output:Meter:MeterFileOnly,
        ExteriorLights:Electricity,  !- Name
        hourly;                  !- Reporting Frequency

      Output:Meter:MeterFileOnly,
        Carbon Equivalent:Facility,  !- Name
        hourly;                  !- Reporting Frequency

      Output:Meter:MeterFileOnly,
        EnergyTransfer:Building, !- Name
        hourly;                  !- Reporting Frequency

      Output:Meter:MeterFileOnly,
        EnergyTransfer:Facility, !- Name
        hourly;                  !- Reporting Frequency

      OutputControl:Table:Style,
        HTML;                    !- Column Separator

      Output:Table:SummaryReports,
        AllSummary;              !- Report 1 Name

      Exterior:Lights,
        ExtLights,               !- Name
        AlwaysOn,                !- Schedule Name
        5250,                    !- Design Level {W}
        AstronomicalClock,       !- Control Option
        Grounds Lights;          !- End-Use Subcategory

      ScheduleTypeLimits,
        On/Off,                  !- Name
        0:1,                     !- Range
        DISCRETE;                !- Numeric Type

      Schedule:Day:Hourly,
        On,                      !- Name
        On/Off,                  !- Schedule Type Limits Name
        1.,                      !- Hour 1
        1.,                      !- Hour 2
        1.,                      !- Hour 3
        1.,                      !- Hour 4
        1.,                      !- Hour 5
        1.,                      !- Hour 6
        1.,                      !- Hour 7
        1.,                      !- Hour 8
        1.,                      !- Hour 9
        1.,                      !- Hour 10
        1.,                      !- Hour 11
        1.,                      !- Hour 12
        1.,                      !- Hour 13
        1.,                      !- Hour 14
        1.,                      !- Hour 15
        1.,                      !- Hour 16
        1.,                      !- Hour 17
        1.,                      !- Hour 18
        1.,                      !- Hour 19
        1.,                      !- Hour 20
        1.,                      !- Hour 21
        1.,                      !- Hour 22
        1.,                      !- Hour 23
        1.;                      !- Hour 24

      Schedule:Week:Daily,
        On Weeks,                !- Name
        On,                      !- Sunday Schedule:Day Name
        On,                      !- Monday Schedule:Day Name
        On,                      !- Tuesday Schedule:Day Name
        On,                      !- Wednesday Schedule:Day Name
        On,                      !- Thursday Schedule:Day Name
        On,                      !- Friday Schedule:Day Name
        On,                      !- Saturday Schedule:Day Name
        On,                      !- Holiday Schedule:Day Name
        On,                      !- SummerDesignDay Schedule:Day Name
        On,                      !- WinterDesignDay Schedule:Day Name
        On,                      !- CustomDay1 Schedule:Day Name
        On;                      !- CustomDay2 Schedule:Day Name

      Schedule:Year,
        AlwaysOn,                !- Name
        On/Off,                  !- Schedule Type Limits Name
        On Weeks,                !- Schedule:Week Name 1
        1,                       !- Start Month 1
        1,                       !- Start Day 1
        12,                      !- End Month 1
        31;                      !- End Day 1