This document is intended for developers who are creating
user interfaces for EnergyPlus. It provides an overview of the
essentials of the input-output structure of EnergyPlus and
describes the parts of each in detail.
The diagram shown above should give the reader an overall
picture of input-output in EnergyPlus. It can be seen as a
linear process that includes the following steps:
- The user enters building description (including internal
space gains, HVAC arrangements, and Plant equipment
properties) using the interface of their choice. In addition,
the user specifies which non-default reports are desired and
any optional variables from a predefined list of available
simulation quantities.
- The interface program writes the Input Data File (IDF)
file, which includes the specification of any report items
desired by the user.
- EnergyPlus processes both the Input Data Dictionary (IDD)
and the Input Data File (IDF) files with the “InputProcessor”.
The InputProcessor uses the specifications/rules defined in
the IDD and interprets the IDF raw data. The InputProcessor is
really quite “dumb” and only understands a few things about
each field (alpha or numeric) qualified by certain key
elements in the IDD (\ comments which are discussed
later).
- Each module in EnergyPlus has one or several routines
(normally called “GetInput” routines) that obtain the
information from the IDF file data. These subroutines decode
the portion of the IDF file that is pertinent to the local
module. These GetInput routines are more context sensitive
than the InputProcessor and may perform further error
detection. For example, the cooling coil module may read in
the coil type and its associated parameters (number of rows,
tube diameter, fin spacing, etc.).
- EnergyPlus performs the simulation elements specified in
the IDF. Output is generated as a continuous stream (for the
most part) and must be interpreted into a more cohesive form
by output processing. The user has control over which outputs
are produced and when/how often.
- EnergyPlus produces output as required by the user into
one of the output files. These files can be readily processed
into spreadsheet formats for graphing and other
summarizing.
Introduction[LINK]
This document is intended for developers who are creating user interfaces for EnergyPlus. It provides an overview of the essentials of the input-output structure of EnergyPlus and describes the parts of each in detail.
The diagram shown above should give the reader an overall picture of input-output in EnergyPlus. It can be seen as a linear process that includes the following steps: