Important Rules
for Module Developers[LINK]
- INITIALIZE!!!!! INITIALIZE either fully or “invalidly”
when you ALLOCATE the array/derived type. Two items have been
set up to help you: BigNumber and DBigNumber are in
DataGlobals. They get initialized before anything happens in
the main routine (EnergyPlus). An invalid initialization can
use one of these, appropriately (i.e. set and test for
“BigNumber”). Another example of “invalid” initialization is a
value that shouldn’t be legal for the item (-999).
- Warning errors during “get input” should only be used when
program termination is not required (this is rare). Each
GetInput routine should be structured so that errors detected
(such as an invalid schedule name which currently is just a
warning) cause a fatal error after all the input for that
item/module/etc is gotten. (See HBManager, BaseboardRadiator,
others) In addition, don’t make GetInputFlag a module
variable. Make it as “local” as possible. Look at
BaseboardRadiator for an example.
- Error messages during simulation should be
semi-intelligent. No one wants to see 5,000 messages saying
“this flow invalid”. If the error condition might happen a lot
(especially during debugging), count each occurrence and only
put out a message every 50 or so. It is better to use the
“Recurring Error Handling” routines. (See examples of both
above in the Error Messages section). Also, if you are putting
the same message in two modules, identify the error message
with some designation. For Example,
- CALL ShowWarningError (’SimRoutinename:
this condition happened again’)
- will help everyone track it down. Use the
ShowContinueErrorTimeStamp so the time/date/environment of
occurrence is known, as appropriate for the condition.
- Use the templates for documentation! Modules, subroutines,
functions templates all have been checked into StarTeam. Use
them. Put INTENTs on your Subroutine Arguments. Document
variables.
- Add “meter” variables as appropriate! If your
module uses fuel or electricity and that energy is not
accounted for by other components (i.e. pumps, coils,
chillers, etc), then you need to report it onto a
“meter”.
- Avoid the use of string comparisons in subroutines
other than GetInput. Check string comparisons in the GetInput
subroutines and assign an integer parameter for comparisons
elsewhere in the module. Character strings in structures are
not allowed (except for name of object) - any exceptions must
be approved. Schedule names, curve object names, and child
object types MUST all be referenced by an integer. Existing
code must be changed as you change any of the code within a
module.
- If you are submitting code for insertion in the
public version of EnergyPlus, make sure that the proper
“Grant-Back” procedure has been followed so that the correct
attributions of code authorship are given as well as
permission to use this code in publicly available software is
assured. (see Appendix G, Code/Module Contribution
Questionnaire - also available separately)