Diffuse
Reflection of Beam Solar and Sky Solar Radiation[LINK]
A ray-tracing method is used to calculate beam solar and
sky solar radiation that is diffusely reflected onto each of a
building’s exterior surfaces (walls, roofs, windows and
doors), called here “receiving surfaces.” The calculation
begins by generating a set of rays proceeding into the outward
hemisphere at each receiving point on a receiving surface.
Then it determinines whether each ray hits the sky, ground or
an obstruction. The radiance at the hit point from reflection
of incident beam or sky solar is determined and the
contribution of this radiance to the receiving surface is
calculated, added to the contribution from other hit points,
and averaged over the receiving points. Separate calculations
are done for beam-to-diffuse and sky solar reflection from all
obstructions and beam-to-diffuse and sky solar reflection from
the ground. (For beam-to-beam reflection see “Beam Solar
Radiation Specularly Reflected from Obstructions,” below.)
If N > 3: akj = \(\frac{{N + 1}}{{2N}}\) if
k = i; = \(\frac{1}{{2N}}\) otherwise
For example, for a vertical 3m by 5m rectangle with
vertices (0,0,3), (0,0,0), (5,0,0) and (5,0,3), this
expression gives receiving points at (1.25,0,2.25),
(1.25,0,0.75), (3.75,0,0.75) and (3.75,0,2.25), as shown in
Figure 53.
Vertical rectangular exterior
heat transfer surface showing location of receiving points for
calculating incident solar radiation reflected from
obstructions.
A total of 90 rays are sent out into the exterior
hemisphere surrounding each receiving point. An upgoing ray
may hit an obstruction or the sky. A downgoing ray may hit an
obstruction or the ground. See Figure 54.
In subroutine InitSolReflRecSurf, the following is
determined for each ray, i, :
Unit vector in direction of ray
Cosine of angle between ray and plane of receiving surface
( \(\cos {\alpha _i}\) )
Element of solid angle associated with ray ( \(d{\Omega _i}\) )
If the ray hits one or more obstructions, the coordinates
of the hit point on the obstruction nearest the receiving
point
For the surface containing the hit point: the surface
number, the solar reflectance ( \({\rho _{obs,i}}\) if an
obstruction), and the surface unit vector at the hit point
pointing into the hemisphere containing the receiving
point
If the ray is downgoing and hits the ground, the
coordinates of the ground hit point
Distance from receiving point to hit point
Two-dimensional schematic
showing rays going outward from a point on a receiving
surface. Rays 1-6 hit the ground, rays 7-11 hit an
obstruction, and rays 12-15 hit the sky.
Sky
Solar Radiation Diffusely Reflected from Obstructions[LINK]
The factor for reflection of sky radiation from
obstructions onto a receiving surface is calculated in
subroutine CalcSkySolDiffuseReflFactors. It is given by:
Hitobs,i = 1 if ray i hits an
obstruction, = 0 otherwise,
ViewFacSkyobs,i = unobstructed sky view
factor of the obstruction = \((1 +
\cos til{t_{obs}})/2\) ,
DifShdgRatioIsoSkyobs,i = (obstructed
sky irradiance on obstruction)/(unobstructed sky irradiance on
obstruction)
In this equation the product
ViewFacSky*DifShdgRatioIsoSky is the sky irradiance
at the hit point divided by the horizontal sky irradiance
taking into account shadowing of sky diffuse radiation on the
obstruction by other obstructions, and assuming that the
radiance of the sky is uniform. Note that we ignore secondary
reflections here and in the following sections. In the present
case this means that the irradiance at the hit point due to
reflection of sky radiation from the ground or from other
obstructions is not considered.
The above reflection factor is used in the timestep
calculation to find the irradiance on a receiving surface due
to sky radiation reflected from obstructions:
where DifSolarRad is the horizontal sky irradiance
on an unobstructed horizontal plane (W/m2).
Sky
Solar Radiation Diffusely Reflected from the Ground[LINK]
If a downgoing ray from a receiving point hits the ground
(for example, rays 1-6 in Figure 54), the program calculates
the radiance at the ground hit point due to sky diffuse solar
reaching that point. To do this, rays are sent upward from the
ground hit point and it is determined which of these rays are
unobstructed and so go to the sky (for example, rays 6-10 in
Figure 55). For this calculation it is assumed that the
radiance of the sky is uniform.
Two-dimensional schematic
showing rays going upward from a ground hit
point.
The factor for reflection of sky radiation from the ground
onto a receiving surface is calculated in subroutine
CalcSkySolDiffuseReflFactors. It is given by:
where \({\rho _{gnd}}\) is
the solar reflectance of the ground, which is assumed to be
uniform over the ground plane but may vary monthly (because of
snow cover, for example).
Beam
Solar Radiation Diffusely Reflected from Obstructions[LINK]
This calculation is similar to that for sky solar reflected
from obstructions. However, to find the radiance at a hit
point on an obstruction a line is drawn from the hit point to
center of the sun. From this line it is determined (1) if
there is an obstruction between the hit point and the sun, in
which case it is assumed that no beam solar reaches the hit
point; and (2) if beam solar does reach the hit point, what
the the solar angle of incidence at that point is.
The calculation is done for the hourly sun positions on
each of the design days. It is also done for hourly sun
positions on selected days during the weather file run period
(the same days for which the shadowing calculations are
done).
The factor for diffuse reflection of beam solar radiation
from obstructions onto a receiving surface is calculated in
subroutine CalcBeamSolDiffuseReflFactors. It is given by:
\(Hi{t_{obs,i}}\) = 1 if
ray i from the receiving point hits an obstruction, =
0 otherwise,
\(Hi{t_{obs,i,sun}}\) = 1
if the line from ray i’s hit point to the sun is
unobstructed, = 0 otherwise,
\({\alpha _{sun,obs,i}}\)
is the angle of incidence of the sun on the obstruction.
This factor is used in the timestep calculation to find the
diffuse irradiance on a receiving surface due to beam solar
diffusely reflected from obstructions:
where BeamSolarRad is the timestep value of beam
normal solar intensity (W/m2), and WeightNow and
WeightPreviousHour are time-averaging factors.
Beam
Solar Radiation Diffusely Reflected from the Ground[LINK]
This calculation is the same as that for beam solar
diffusely reflected from obstructions except that only rays
from a receiving point that hit the ground are considered. The
factor for diffuse reflection of beam solar from the ground
onto a receiving surface is calculated in subroutine
CalcBeamSolDiffuseReflFactors. It is given by:
\(Hi{t_{gnd,i}}\) = 1 if
ray i hits the ground, = 0 otherwise,
\(Hi{t_{gnd,i,sun}}\) = 1
if the line from ray i’s hit point ot the sun is
unobstructed, = 0 otherwise,
\({\alpha _{sun,gnd}}\) =
angle of incidence of sun on ground (= solar zenith
angle).
This factor is used in the timestep calculation to find the
diffuse irradiance on a receiving surface due to beam solar
diffusely reflected from the ground:
Beam
Solar Radiation Specularly Reflected from Obstructions[LINK]
Figure 56 shows schematically how specular (beam-to-beam)
reflection from an obstruction is calculated.
Two-dimensional schematic
showing specular reflection from an obstruction such as the
glazed façade of a neighboring building. The receiving point
receives specularly reflected beam solar radiation if (1) DB
passes through specularly reflecting surface EF, (2) CD does
not hit any obstructions (such as RS), and (3) AC does not hit
any obstructions (such as PQ).
The calculation procedure is as follows:
Select receiving point D on receiving surface JK.
Select specularly reflecting surface EF.
Find the mirror image, B, of the sun with respect to the
plane of EF and construct ray DB.
Check if DB passes through EF; if yes, find intersection
point C and construct ray CD.
Check if CD is obstructed.
If no, construct ray AC and check if it is obstructed.
If no, find reflected beam irradiance (W/m2) at
D:
\({\alpha _C}\) = angle of
incidence of beam solar at point C of the obstruction,
\({\rho _{spec}}({\alpha
_C})\) = reflectance of obstruction as a function of
the angle of incidence,
\({\alpha _D}\) = angle of
incidence of ray CD on JK.
The factor for specular reflection of beam solar from
obstruction onto a receiving surface is calculated in
subroutine CalcBeamSolSpecularReflFactors. It is given by:
The program assumes that specular reflection from a surface
is due to glazing. If the reflecting surface is a window
belonging to the building itself (as in Figure 51), then \({f_{C,glazed}}\) is the fraction
of the window that is glazed (which is 1.0 unless the window
has dividers).
If the surface is a shading surface (that represents, for
example, the glazed façade of a neigboring building) the
surface reflection information is entered with the Shading
Surface Reflectance object. This object contains values
for:
Diffuse solar reflectance of the unglazed part of the
shading surface
Diffuse visible reflectance of the unglazed part of the
shading surface
Fraction of shading surface that is glazed
Name of glazing construction
In this case \({f_{C,glazed}}\) is “Fraction of
shading surface that is glazed” and \({\rho _{spec}}({\alpha _C})\) is
the front reflectance of the indicated glazing construction as
a function of beam solar incidence angle.
The above specular reflection factor is used in the
timestep calculation to find the beam irradiance on a
receiving surface due to beam-beam reflection from
obstructions:
Diffuse Reflection of Beam Solar and Sky Solar Radiation[LINK]
A ray-tracing method is used to calculate beam solar and sky solar radiation that is diffusely reflected onto each of a building’s exterior surfaces (walls, roofs, windows and doors), called here “receiving surfaces.” The calculation begins by generating a set of rays proceeding into the outward hemisphere at each receiving point on a receiving surface. Then it determinines whether each ray hits the sky, ground or an obstruction. The radiance at the hit point from reflection of incident beam or sky solar is determined and the contribution of this radiance to the receiving surface is calculated, added to the contribution from other hit points, and averaged over the receiving points. Separate calculations are done for beam-to-diffuse and sky solar reflection from all obstructions and beam-to-diffuse and sky solar reflection from the ground. (For beam-to-beam reflection see “Beam Solar Radiation Specularly Reflected from Obstructions,” below.)
Receiving points[LINK]
An N-sided surface is assigned N receiving points with the following coordinates, expressed in terms of the surface vertex coordinates:
\[{P_{ij}} = \sum\limits_{k = 1}^N {{a_{ki}}{v_{kj}},{\rm{ }}i = 1,3;{\rm{ }}j = 1,3}\]
where
Pij = jth coordinate of the ith receiving point
vkj = jth coordinate of the kth surface vertex
If N = 3: akj = 3/5 if k = i; = 1/5 otherwise
If N > 3: akj = \(\frac{{N + 1}}{{2N}}\) if k = i; = \(\frac{1}{{2N}}\) otherwise
For example, for a vertical 3m by 5m rectangle with vertices (0,0,3), (0,0,0), (5,0,0) and (5,0,3), this expression gives receiving points at (1.25,0,2.25), (1.25,0,0.75), (3.75,0,0.75) and (3.75,0,2.25), as shown in Figure 53.
Rays[LINK]
A total of 90 rays are sent out into the exterior hemisphere surrounding each receiving point. An upgoing ray may hit an obstruction or the sky. A downgoing ray may hit an obstruction or the ground. See Figure 54.
In subroutine InitSolReflRecSurf, the following is determined for each ray, i, :
Unit vector in direction of ray
Cosine of angle between ray and plane of receiving surface ( \(\cos {\alpha _i}\) )
Element of solid angle associated with ray ( \(d{\Omega _i}\) )
If the ray hits one or more obstructions, the coordinates of the hit point on the obstruction nearest the receiving point
For the surface containing the hit point: the surface number, the solar reflectance ( \({\rho _{obs,i}}\) if an obstruction), and the surface unit vector at the hit point pointing into the hemisphere containing the receiving point
If the ray is downgoing and hits the ground, the coordinates of the ground hit point
Distance from receiving point to hit point
Sky Solar Radiation Diffusely Reflected from Obstructions[LINK]
The factor for reflection of sky radiation from obstructions onto a receiving surface is calculated in subroutine CalcSkySolDiffuseReflFactors. It is given by:
\[\begin{array}{l}{\rm{ReflFacSkySolObs(RecSurfNum)}} = \\\frac{1}{{{N_{rec}}}}\sum\limits_1^{{N_{rec}}} {\sum\limits_{i = 1}^{{N_{ray}}} {Hi{t_{obs,i}}ViewFacSk{y_{obs,i}}DifShdgRatioIsoSk{y_{obs,i}}{\rho _{obs,i}}\cos {\alpha _i}/\pi } }\end{array}\]
where
RecSurfNum is the receiving surface number,
\({N_{rec}}\) is the number of receiving points,
\({N_{ray}}\) is the number of rays,
“obs,i” denotes the obstruction hit by ray i, **
Hitobs,i = 1 if ray i hits an obstruction, = 0 otherwise,
ViewFacSkyobs,i = unobstructed sky view factor of the obstruction = \((1 + \cos til{t_{obs}})/2\) ,
DifShdgRatioIsoSkyobs,i = (obstructed sky irradiance on obstruction)/(unobstructed sky irradiance on obstruction)
In this equation the product ViewFacSky*DifShdgRatioIsoSky is the sky irradiance at the hit point divided by the horizontal sky irradiance taking into account shadowing of sky diffuse radiation on the obstruction by other obstructions, and assuming that the radiance of the sky is uniform. Note that we ignore secondary reflections here and in the following sections. In the present case this means that the irradiance at the hit point due to reflection of sky radiation from the ground or from other obstructions is not considered.
The above reflection factor is used in the timestep calculation to find the irradiance on a receiving surface due to sky radiation reflected from obstructions:
where DifSolarRad is the horizontal sky irradiance on an unobstructed horizontal plane (W/m2).
Sky Solar Radiation Diffusely Reflected from the Ground[LINK]
If a downgoing ray from a receiving point hits the ground (for example, rays 1-6 in Figure 54), the program calculates the radiance at the ground hit point due to sky diffuse solar reaching that point. To do this, rays are sent upward from the ground hit point and it is determined which of these rays are unobstructed and so go to the sky (for example, rays 6-10 in Figure 55). For this calculation it is assumed that the radiance of the sky is uniform.
The factor for reflection of sky radiation from the ground onto a receiving surface is calculated in subroutine CalcSkySolDiffuseReflFactors. It is given by:
\[\begin{array}{l}{\rm{ReflFacSkySolGnd(RecSurfNum)}} = \\frac{1}{{{N_{rec}}}}\sum\limits_1^{{N_{rec}}} {\sum\limits_{i = 1}^{{N_{ray}}} {\left[ {(Hi{t_{gnd,i}}d{\Omega _i}\cos {\alpha _i}/\pi )\sum\limits_{j(i)}^{{N_{ray}}} {Hi{t_{sky,j(i)}}\cos {\alpha _{j(i)}}d{\Omega _{j(i)}}/\pi } } \right]} } \end{array}\]
where
Hitsky,j(i) = 1 if ray j(i) hits the sky, = 0 otherwise,
\({\alpha _{j(i)}}\) is the angle of incidence of ray \(j(i)\) with respect to the ground plane,
\(d{\Omega _{j(i)}}\) is the solid angle element associated with ray \(j(i)\) .
This factor is used in the timestep calculation to find the irradiance on a receiving surface due to sky radiation reflected from the ground:
where \({\rho _{gnd}}\) is the solar reflectance of the ground, which is assumed to be uniform over the ground plane but may vary monthly (because of snow cover, for example).
Beam Solar Radiation Diffusely Reflected from Obstructions[LINK]
This calculation is similar to that for sky solar reflected from obstructions. However, to find the radiance at a hit point on an obstruction a line is drawn from the hit point to center of the sun. From this line it is determined (1) if there is an obstruction between the hit point and the sun, in which case it is assumed that no beam solar reaches the hit point; and (2) if beam solar does reach the hit point, what the the solar angle of incidence at that point is.
The calculation is done for the hourly sun positions on each of the design days. It is also done for hourly sun positions on selected days during the weather file run period (the same days for which the shadowing calculations are done).
The factor for diffuse reflection of beam solar radiation from obstructions onto a receiving surface is calculated in subroutine CalcBeamSolDiffuseReflFactors. It is given by:
\[{\rm{ReflFacBmToDiffSolObs(RecSurfNum,IHr)}} = \frac{1}{{{N_{rec}}}}\sum\limits_1^{{N_{rec}}} {\sum\limits_{i = 1}^{{N_{ray}}} {Hi{t_{obs,i}}Hi{t_{obs,i,sun}}d{\Omega _i}\cos {\alpha _i}{\rho _{obs,i}}\cos {\alpha _{sun,obs,i}}} }\]
where
IHr = hour number
\(Hi{t_{obs,i}}\) = 1 if ray i from the receiving point hits an obstruction, = 0 otherwise,
\(Hi{t_{obs,i,sun}}\) = 1 if the line from ray i’s hit point to the sun is unobstructed, = 0 otherwise,
\({\alpha _{sun,obs,i}}\) is the angle of incidence of the sun on the obstruction.
This factor is used in the timestep calculation to find the diffuse irradiance on a receiving surface due to beam solar diffusely reflected from obstructions:
where BeamSolarRad is the timestep value of beam normal solar intensity (W/m2), and WeightNow and WeightPreviousHour are time-averaging factors.
Beam Solar Radiation Diffusely Reflected from the Ground[LINK]
This calculation is the same as that for beam solar diffusely reflected from obstructions except that only rays from a receiving point that hit the ground are considered. The factor for diffuse reflection of beam solar from the ground onto a receiving surface is calculated in subroutine CalcBeamSolDiffuseReflFactors. It is given by:
\[{\rm{ReflFacBmToDiffSolGnd(RecSurfNum,IHr)}} = \frac{1}{{{N_{rec}}}}\sum\limits_1^{{N_{rec}}} {\sum\limits_{i = 1}^{{N_{ray}}} {Hi{t_{gnd,i}}Hi{t_{gnd,i,sun}}d{\Omega _i}\cos {\alpha _{gnd,i}}\cos {\alpha _{sun,gnd}}} }\]
where
\(Hi{t_{gnd,i}}\) = 1 if ray i hits the ground, = 0 otherwise,
\(Hi{t_{gnd,i,sun}}\) = 1 if the line from ray i’s hit point ot the sun is unobstructed, = 0 otherwise,
\({\alpha _{sun,gnd}}\) = angle of incidence of sun on ground (= solar zenith angle).
This factor is used in the timestep calculation to find the diffuse irradiance on a receiving surface due to beam solar diffusely reflected from the ground:
Beam Solar Radiation Specularly Reflected from Obstructions[LINK]
Figure 56 shows schematically how specular (beam-to-beam) reflection from an obstruction is calculated.
The calculation procedure is as follows:
Select receiving point D on receiving surface JK.
Select specularly reflecting surface EF.
Find the mirror image, B, of the sun with respect to the plane of EF and construct ray DB.
Check if DB passes through EF; if yes, find intersection point C and construct ray CD.
Check if CD is obstructed.
If no, construct ray AC and check if it is obstructed.
If no, find reflected beam irradiance (W/m2) at D:
\[I_{D,refl}^{bm} = BeamSolarRad*{\rho _{spec}}({\alpha _C})\cos {\alpha _D}\]
where
\({\alpha _C}\) = angle of incidence of beam solar at point C of the obstruction,
\({\rho _{spec}}({\alpha _C})\) = reflectance of obstruction as a function of the angle of incidence,
\({\alpha _D}\) = angle of incidence of ray CD on JK.
The factor for specular reflection of beam solar from obstruction onto a receiving surface is calculated in subroutine CalcBeamSolSpecularReflFactors. It is given by:
\[{\rm{ReflFacBmToBmSolObs(RecSurfNum,IHr) }} = \sum_{\text{specularly reflecting surfaces}} \left[ {\frac{1}{{{N_{rec}}}}\sum\limits_1^{{N_{rec}}} {{f_{C,glazed}}{\rho _{spec}}({\alpha _C})\cos {\alpha _D}} } \right]\]
The program assumes that specular reflection from a surface is due to glazing. If the reflecting surface is a window belonging to the building itself (as in Figure 51), then \({f_{C,glazed}}\) is the fraction of the window that is glazed (which is 1.0 unless the window has dividers).
If the surface is a shading surface (that represents, for example, the glazed façade of a neigboring building) the surface reflection information is entered with the Shading Surface Reflectance object. This object contains values for:
Diffuse solar reflectance of the unglazed part of the shading surface
Diffuse visible reflectance of the unglazed part of the shading surface
Fraction of shading surface that is glazed
Name of glazing construction
In this case \({f_{C,glazed}}\) is “Fraction of shading surface that is glazed” and \({\rho _{spec}}({\alpha _C})\) is the front reflectance of the indicated glazing construction as a function of beam solar incidence angle.
The above specular reflection factor is used in the timestep calculation to find the beam irradiance on a receiving surface due to beam-beam reflection from obstructions:
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.