The VRML output report file is formatted according to the
“Virtual Reality Modeling Language” standard rules for
representing building type surfaces. The file can be used in
several inexpensive, shareware or freeware viewers. There are
a variety of stand alone and viewers integrated within
browsers. A good list of viewers can be found at:
http://cic.nist.gov/vrml/vbdetect.html
This site detects what, if any, VRML plugin is installed in
your browser as well as gives a list of active ones with links
to their sites.
This file is generated when the following line is included
in the IDF.
Output:Surfaces:Drawing, VRML;
In addition, like the DXF output, you can ask it to
triangulate (algorithm within EnergyPlus) surfaces with >4
sides:
Most viewers will illustrate a solid model by default:
VRML output - solid
model
With some/many viewers, you can also see a wireframe model;
some will even fill this model. Also, viewers can triangulate
any surface that isn’t labeled as “convex” by the software
writing the file (i.e. EnergyPlus). However, this
triangulation may not be correct so you may wish to do it from
within EnergyPlus as illustrated above.
A wireframe model of the same building as above is:
VRML output - wireframe
model
The actual file produced is a text file. EnergyPlus adds
some comments, such as the list of zone names and surface
names before each coordinate specification. The line/solid
colors are set as Floor, Wall, etc. so the file is somewhat
readable.
eplusout.wrl[LINK]
The VRML output report file is formatted according to the “Virtual Reality Modeling Language” standard rules for representing building type surfaces. The file can be used in several inexpensive, shareware or freeware viewers. There are a variety of stand alone and viewers integrated within browsers. A good list of viewers can be found at:
http://cic.nist.gov/vrml/vbdetect.html
This site detects what, if any, VRML plugin is installed in your browser as well as gives a list of active ones with links to their sites.
This file is generated when the following line is included in the IDF.
In addition, like the DXF output, you can ask it to triangulate (algorithm within EnergyPlus) surfaces with >4 sides:
Most viewers will illustrate a solid model by default:
With some/many viewers, you can also see a wireframe model; some will even fill this model. Also, viewers can triangulate any surface that isn’t labeled as “convex” by the software writing the file (i.e. EnergyPlus). However, this triangulation may not be correct so you may wish to do it from within EnergyPlus as illustrated above.
A wireframe model of the same building as above is:
The actual file produced is a text file. EnergyPlus adds some comments, such as the list of zone names and surface names before each coordinate specification. The line/solid colors are set as Floor, Wall, etc. so the file is somewhat readable.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.