Results Processing[LINK]
Results from EnergyPlus (using EP-Launch) appear in several
possible formats. The most basic are the csv files for the
time oriented output and the meter output. These will appear
as <filename>.csv and <filename>Meter.csv. These
can be quite detailed files (ref: Output:Variable,
Output:Meter
commands). Other formats (such as Tabular outputs) can yield
more summarized results. These files and contents are
described in more detail in the “Output
Details and Examples” document.
As an example, here is what the normal “csv” file might
look like in Excel™:

Figure 23. Results in Spreadsheet format
Likewise, a tabular output (usually in HTML format – which
can be read by any web browser) might look like:
End Uses
|
|
Electricity (GJ)
|
Natural Gas (GJ)
|
Other Fuel (GJ)
|
Purchaseh Cooling (GJ)
|
Purchaseh Heating (GJ)
|
Water (m3)
|
|
Heating
|
0.00
|
95.17
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Cooling
|
56.78
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
124.39
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
28.27
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
73.52
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
0.08
|
85.39
|
0.00
|
0.00
|
0.00
|
363.07
|
|
Refrigeration
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
|
|
|
|
|
|
|
|
Total End Uses
|
283.03
|
180.56
|
0.00
|
0.00
|
0.00
|
363.07
|
Results Processing[LINK]
Results from EnergyPlus (using EP-Launch) appear in several possible formats. The most basic are the csv files for the time oriented output and the meter output. These will appear as <filename>.csv and <filename>Meter.csv. These can be quite detailed files (ref: Output:Variable, Output:Meter commands). Other formats (such as Tabular outputs) can yield more summarized results. These files and contents are described in more detail in the “Output Details and Examples” document.
As an example, here is what the normal “csv” file might look like in Excel™:
Figure 23. Results in Spreadsheet format
Likewise, a tabular output (usually in HTML format – which can be read by any web browser) might look like:
End UsesDocumentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.