Output Details and Examples — EnergyPlus 8.8

<< Prev | Table of Contents | Object Index | Next >>

readvars.rvaudit[LINK]

This file is available from standard EnergyPlus runs (batch file, EP-Launch, etc) where the included utility “ReadVarsESO” is used to create .csv or other delimited files. It shows what steps were taken during the read vars run(s) – in standard EnergyPlus runs there are two: one for the .eso file and one for the .mtr file. Contents might be:

Mon 04/02/2007 19:34:17.09 ReadVars

 ReadVarsESO

 processing:eplusout.inp

 input file:eplusout.eso

 output file:eplusout.csv

 found/finding:

     1 Outdoor Dry Bulb

     6 Zone/Sys Air Temperature

     6 Zone/Sys Sensible Cooling Rate

     6 Zone/Sys Sensible Heating Rate

     6 Total Water Heating Coil Rate

     1 Total Water Cooling Coil Rate

     1 Sensible Water Cooling Coil Rate

     2 Plant Loop Cooling Demand

     2 Plant Loop Heating Demand

     1 Boiler Gas Consumption Rate

     1 Boiler Heating Output Rate

     1 Chiller Electric Power

     1 Chiller Evap Heat Trans Rate

     1 Chiller Evap Water Inlet Temp

     1 Chiller Evap Water Outlet Temp

     1 Chiller Evap Water Mass Flow Rate

     1 Chiller Cond Heat Trans Rate

     0 Chiller Cond Water Inlet Temp

     0 Chiller Cond Water Outlet Temp

     0 Chiller Cond Water Mass Flow Rate

     2 Pump Mass Flow Rate

     2 Pump Outlet Temp

 ReadVars Run Time = 00hr 00min  1.78sec

 ReadVarsESO program completed successfully.

 ReadVarsESO

 processing:test.mvi

 input file:eplusout.mtr

 output file:eplusmtr.csv

 getting all vars from:eplusout.mtr

 ReadVars Run Time = 00hr 00min  0.00sec

 ReadVarsESO program completed successfully.