Conceptual
Framework – Variables and Hierarchy[LINK]
To understand how to use the utility bill calculation
portion of EnergyPlus you first need to understand some
important concepts of variables and hierarchy. A variable, for
the purposes of this section, is simply a named holder of a
series of numbers. In most cases, the variable will be a named
holder of 12 numbers, one number for each monthly utility
bill. Here is a visualization of a variable called Electric
Energy Use:
Example Electric Energy Use (for Economics
Calculation)
Month
Electric Energy Use
January
12143
February
13454
March
14178
April
14876
May
15343
June
16172
July
16105
August
15762
September
14543
October
13987
November
13287
December
12403
If you have ever done any computer programming, you can
think of a variable as an array. Many of the names used in the
utility bill calculation portion of EnergyPlus are names of
variables. In the case of the UtilityCost:Charge objects, the
name of the object is also used as a name of a variable.
In many of today’s utility rates, the charges for energy or
demand are broken into distribution and supply charges. To
allow for this, more than one charge may to be defined for a
particular category. The variables assigned to the same
category are added together.
The categories are combined in following hierarchy:
Hierarchy for Economics
Charges
Any charges included in the EnergyCharges category are
added together. The EnergyCharges, DemandCharges and
ServiceCharges are added together to form the Basis. The
Basis, Adjustments and Surcharges are added together to form
the Subtotal. The Subtotal and Taxes are added together to be
the Total. The total represents the total monthly charges on
that tariff for the energy source used. The combining of
categories together is performed automatically unless the user
specifies the UtilityCost:Computation.
In addition, each category, which is also a variable, may be
used as a source. For example, a tax that is 5% of the
subtotal would be shown as:
UtilityCost:Charge:Simple,
TaxOfFivePercent, ! Charge Variable Name
TariffExample1, ! Tariff Name
Subtotal, ! Source Variable
Annual, ! Season
Taxes, ! Category Variable Name
0.05; ! Cost Per Unit Value or Variable Name
As you can see, the UtilityCost:Charge:Simple
and UtilityCost:Charge:Block
objects do most of the “work” of computing the annual energy
cost. The benefit of using this categorization is that totals
of each category are shown in the output reports and it
organizes the charges in the monthly calculations in a logical
way that fits almost all tariffs. If no categorization is
desired, theoretically, all charges could be assigned to the
Total category. The categories themselves are simply variable
names. Charges may also be assigned to the “NotIncluded”
category if the result of the charge is used as an
intermediate calculation and should not be included in the
Total.
The rest of this section is divided into a reference of the
objects and the fields, a set of examples, discussion of the
reporting, and a description of Complex Tariff Modeling. For
most tariffs, simply using a variety of
UtilityCost:Charge:Simple’s and UtilityCost:Charge:Block’s
will result in a good model but for some more complex tariffs,
especially ones with complex block sizes, variables may be
computed using a very simple programming language that may
appear in the UtilityCost:Computation
object. This will be described more in the Complex Tariff
Modeling section.
Conceptual Framework – Variables and Hierarchy[LINK]
To understand how to use the utility bill calculation portion of EnergyPlus you first need to understand some important concepts of variables and hierarchy. A variable, for the purposes of this section, is simply a named holder of a series of numbers. In most cases, the variable will be a named holder of 12 numbers, one number for each monthly utility bill. Here is a visualization of a variable called Electric Energy Use:
If you have ever done any computer programming, you can think of a variable as an array. Many of the names used in the utility bill calculation portion of EnergyPlus are names of variables. In the case of the UtilityCost:Charge objects, the name of the object is also used as a name of a variable.
In many of today’s utility rates, the charges for energy or demand are broken into distribution and supply charges. To allow for this, more than one charge may to be defined for a particular category. The variables assigned to the same category are added together.
The categories are combined in following hierarchy:
Any charges included in the EnergyCharges category are added together. The EnergyCharges, DemandCharges and ServiceCharges are added together to form the Basis. The Basis, Adjustments and Surcharges are added together to form the Subtotal. The Subtotal and Taxes are added together to be the Total. The total represents the total monthly charges on that tariff for the energy source used. The combining of categories together is performed automatically unless the user specifies the UtilityCost:Computation. In addition, each category, which is also a variable, may be used as a source. For example, a tax that is 5% of the subtotal would be shown as:
As you can see, the UtilityCost:Charge:Simple and UtilityCost:Charge:Block objects do most of the “work” of computing the annual energy cost. The benefit of using this categorization is that totals of each category are shown in the output reports and it organizes the charges in the monthly calculations in a logical way that fits almost all tariffs. If no categorization is desired, theoretically, all charges could be assigned to the Total category. The categories themselves are simply variable names. Charges may also be assigned to the “NotIncluded” category if the result of the charge is used as an intermediate calculation and should not be included in the Total.
The rest of this section is divided into a reference of the objects and the fields, a set of examples, discussion of the reporting, and a description of Complex Tariff Modeling. For most tariffs, simply using a variety of UtilityCost:Charge:Simple’s and UtilityCost:Charge:Block’s will result in a good model but for some more complex tariffs, especially ones with complex block sizes, variables may be computed using a very simple programming language that may appear in the UtilityCost:Computation object. This will be described more in the Complex Tariff Modeling section.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.