Appendix
D. Module, Subroutine, Function Templates[LINK]
The following module template can and should be used to
create new modules. Following the module template are
subroutine and function templates. You should be able to copy
the template for your own use (or you can get a plain text
version).
MODULE <module_name>
! Module containing the routines dealing with the
<module_name>
! MODULE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS MODULE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! OTHER NOTES:
! na
! USE STATEMENTS:
! <use statements for data only
modules>
USE DataGlobals, ONLY: ShowWarningError, ShowSevereError,
ShowFatalError, &
MaxNameLength, …
! <use statements for access to subroutines in
other modules>
IMPLICIT NONE ! Enforce explicit typing of all
variables
PRIVATE ! Everything private unless explicitly made
public
! MODULE PARAMETER DEFINITIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! MODULE VARIABLE DECLARATIONS:
! na
! SUBROUTINE SPECIFICATIONS FOR MODULE:
! Driver/Manager Routines
PUBLIC Sim<module_name>
! Get Input routines for module
PRIVATE Get<module_name>
! Initialization routines for module
PRIVATE Init<module_name>
PRIVATE Size<module_name>
! Algorithms/Calculation routines for the module
PRIVATE Calc<module_name>
! Update routines to check convergence and update
nodes
PRIVATE Update<module_name>
! Reporting routines for module
PRIVATE Report<module_name>
! Utility routines for module
! these would be public such as:
! PUBLIC Get<module>InletNode
! PUBLIC Get<module>OutletNode
CONTAINS
SUBROUTINE Sim<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables
in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
LOGICAL,SAVE :: GetInputFlag = .true. ! First time,
input is “gotten”
IF (GetInputFlag) THEN
CALL Get<module_name>Input
GetInputFlag = .false.
ENDIF
<… insert any necessary code here>
CALL Init<module_name>(Args)
CALL Calc<module_name>(Args)
CALL Update<module_name>(Args)
CALL Report<module_name>(Args)
RETURN
END SUBROUTINE Sim<module_name>
SUBROUTINE Get<module_name>Input
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: GetNumObjectsFound,
GetObjectItem ! might also use FindItemInList
USE DataIPShortCuts
IMPLICIT NONE ! Enforce explicit typing of all variables
in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
CHARACTER(len = *), PARAMETER :: RoutineName =
‘PutRoutineNameHere’
CHARACTER(len = *), PARAMETER :: CurrentModuleObject =
‘GetModuleObject’
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: Item ! Item to be
“gotten”
! Instead of below, use Variables in IPShortCuts
! CHARACTER(len = MaxNameLength), &
! DIMENSION(x) :: Alphas ! Alpha items
for object
! REAL, DIMENSION(y) :: Numbers ! Numeric
items for object
INTEGER :: NumAlphas ! Number of
Alphas for each GetObjectItem call
INTEGER :: NumNumbers ! Number of
Numbers for each GetObjectItem call
INTEGER :: IOStatus ! Used in
GetObjectItem
LOGICAL :: ErrorsFound = .false.
! Set to true if errors in input, fatal at end of routine
<NumItems> =
GetNumObjectsFound(CurrentModuleObject)
DO Item = 1,<NumItems>
CALL
GetObjectItem(CurrentModuleObject,Item,cAlphaArgs,NumAlphas,
&
rNumericArgs,NumNumbers,IOStatus,
&
AlphaBlank =
lAlphaFieldBlanks,NumBlank = lNumericFieldBlanks, &
AlphaFieldnames =
cAlphaFieldNames,NumericFieldNames = cNumericFieldNames)
<process, noting errors>
! Errors should be formatted as (alpha 1 should hold
the name of the object)
CALL
ShowSevereError(RoutineName//‘:’//CurrentModuleObject//’ =
“’//trim(cAlphaArgs(1)))// &
‘ “, invalid ‘//trim(cAlphaFieldNames(x))//’
=” ’//trim(cAlphaArgs(x))//‘" <condition>.’)
! likewise for numeric fields
ENDDO
<SetupOutputVariables here…>
IF (ErrorsFound) THEN
CALL
ShowFatalError(RoutineName//‘:’//CurrentModuleObject//‘:
Errors found in input.’)
ENDIF
RETURN
END SUBROUTINE
Get<module_name>Input
SUBROUTINE Init<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all
variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Init<module_name>
SUBROUTINE Size<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all
variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Size<module_name>
SUBROUTINE Calc<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables
in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Calc<module_name>
SUBROUTINE Update<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables
in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE
Update<module_name>
SUBROUTINE Report<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables
in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
! <this routine is typically needed only for those
cases where you must transform the internal data to a
reportable form>
RETURN
END SUBROUTINE
Report<module_name>
! = = = = = = = = = = = = = = = = = = = = =
Utility/Other routines for module.
! Insert as appropriate
! Insert Standard Copyright Notice here.
END MODULE <module_name>
The Subroutine Template:
SUBROUTINE <name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine needs a description.
! METHODOLOGY EMPLOYED:
! Needs description, as appropriate.
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all
variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE <name>
And the Function Template:
<type> FUNCTION <name>
! FUNCTION INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function needs a description.
! METHODOLOGY EMPLOYED:
! Needs description, as appropriate.
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all
variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
! na
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END FUNCTION <name>
Appendix D. Module, Subroutine, Function Templates[LINK]
The following module template can and should be used to create new modules. Following the module template are subroutine and function templates. You should be able to copy the template for your own use (or you can get a plain text version).
MODULE <module_name>
! Module containing the routines dealing with the <module_name>
! MODULE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS MODULE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! OTHER NOTES:
! na
! USE STATEMENTS:
! <use statements for data only modules>
USE DataGlobals, ONLY: ShowWarningError, ShowSevereError, ShowFatalError, &
MaxNameLength, …
! <use statements for access to subroutines in other modules>
IMPLICIT NONE ! Enforce explicit typing of all variables
PRIVATE ! Everything private unless explicitly made public
! MODULE PARAMETER DEFINITIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! MODULE VARIABLE DECLARATIONS:
! na
! SUBROUTINE SPECIFICATIONS FOR MODULE:
! Driver/Manager Routines
PUBLIC Sim<module_name>
! Get Input routines for module
PRIVATE Get<module_name>
! Initialization routines for module
PRIVATE Init<module_name>
PRIVATE Size<module_name>
! Algorithms/Calculation routines for the module
PRIVATE Calc<module_name>
! Update routines to check convergence and update nodes
PRIVATE Update<module_name>
! Reporting routines for module
PRIVATE Report<module_name>
! Utility routines for module
! these would be public such as:
! PUBLIC Get<module>InletNode
! PUBLIC Get<module>OutletNode
CONTAINS
SUBROUTINE Sim<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
LOGICAL,SAVE :: GetInputFlag = .true. ! First time, input is “gotten”
IF (GetInputFlag) THEN
CALL Get<module_name>Input
GetInputFlag = .false.
ENDIF
<… insert any necessary code here>
CALL Init<module_name>(Args)
CALL Calc<module_name>(Args)
CALL Update<module_name>(Args)
CALL Report<module_name>(Args)
RETURN
END SUBROUTINE Sim<module_name>
SUBROUTINE Get<module_name>Input
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: GetNumObjectsFound, GetObjectItem ! might also use FindItemInList
USE DataIPShortCuts
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
CHARACTER(len = *), PARAMETER :: RoutineName = ‘PutRoutineNameHere’
CHARACTER(len = *), PARAMETER :: CurrentModuleObject = ‘GetModuleObject’
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: Item ! Item to be “gotten”
! Instead of below, use Variables in IPShortCuts
! CHARACTER(len = MaxNameLength), &
! DIMENSION(x) :: Alphas ! Alpha items for object
! REAL, DIMENSION(y) :: Numbers ! Numeric items for object
INTEGER :: NumAlphas ! Number of Alphas for each GetObjectItem call
INTEGER :: NumNumbers ! Number of Numbers for each GetObjectItem call
INTEGER :: IOStatus ! Used in GetObjectItem
LOGICAL :: ErrorsFound = .false. ! Set to true if errors in input, fatal at end of routine
<NumItems> = GetNumObjectsFound(CurrentModuleObject)
DO Item = 1,<NumItems>
CALL GetObjectItem(CurrentModuleObject,Item,cAlphaArgs,NumAlphas, &
rNumericArgs,NumNumbers,IOStatus, &
AlphaBlank = lAlphaFieldBlanks,NumBlank = lNumericFieldBlanks, &
AlphaFieldnames = cAlphaFieldNames,NumericFieldNames = cNumericFieldNames)
<process, noting errors>
! Errors should be formatted as (alpha 1 should hold the name of the object)
CALL ShowSevereError(RoutineName//‘:’//CurrentModuleObject//’ = “’//trim(cAlphaArgs(1)))// &
‘ “, invalid ‘//trim(cAlphaFieldNames(x))//’ =” ’//trim(cAlphaArgs(x))//‘" <condition>.’)
! likewise for numeric fields
ENDDO
<SetupOutputVariables here…>
IF (ErrorsFound) THEN
CALL ShowFatalError(RoutineName//‘:’//CurrentModuleObject//‘: Errors found in input.’)
ENDIF
RETURN
END SUBROUTINE Get<module_name>Input
SUBROUTINE Init<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Init<module_name>
SUBROUTINE Size<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Size<module_name>
SUBROUTINE Calc<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Calc<module_name>
SUBROUTINE Update<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Update<module_name>
SUBROUTINE Report<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
! <this routine is typically needed only for those cases where you must transform the internal data to a reportable form>
RETURN
END SUBROUTINE Report<module_name>
! = = = = = = = = = = = = = = = = = = = = = Utility/Other routines for module.
! Insert as appropriate
! Insert Standard Copyright Notice here.
END MODULE <module_name>
The Subroutine Template:
SUBROUTINE <name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! This subroutine needs a description.
! METHODOLOGY EMPLOYED:
! Needs description, as appropriate.
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE <name>
And the Function Template:
<type> FUNCTION <name>
! FUNCTION INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS FUNCTION:
! This function needs a description.
! METHODOLOGY EMPLOYED:
! Needs description, as appropriate.
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! FUNCTION ARGUMENT DEFINITIONS:
! na
! FUNCTION PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! FUNCTION LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END FUNCTION <name>