Code
Readability vs. Speed of Execution[LINK]
Programmers throughout time have had to deal with speed of
code execution and it’s an ongoing concern. However,
compilers are pretty smart these days and, often, can produce
speedier code for the hardware platform than the programmer
can when he or she uses “speed up” tips. The EnergyPlus
development team would rather the code be more “readable” to
all than to try to outwit the compilers for every platform.
First and foremost, the code is the true document of what
EnergyPlus does – other documents will try to explain
algorithms and such but must really take a back seat to the
code itself.
However, many people may read the code – as developers, we
should try to make it as readable at first glance as
possible. For a true example from the code and a general
indication of preferred style, take the case of the zone
temperature update equation. In the Engineering
Reference document, the form is recognizable and
usual:

And, this equation appears in the code
(ZoneTempPredictorCorrector Module), as:
ZT(ZoneNum) = (CoefSumhat + CoefAirrat*(3.0*ZTM1(ZoneNum)
- (3.0/2.0)*ZTM2(ZoneNum) &
+ (1./3.)*
ZTM3(ZoneNum))) &
/
((11.0/6.0)*CoefAirrat+CoefSumha)
Somewhat abbreviated here due to lack of page width but
still recognizable from the original. A better version would
actually be:
ZT(ZoneNum) = (CoefSumhat -
CoefAirrat*(-3.0*ZTM1(ZoneNum) + (3.0/2.0)*ZTM2(ZoneNum)
&
- (1./3.)*
ZTM3(ZoneNum))) &
/
((11.0/6.0)*CoefAirrat+CoefSumha)
Whereas the natural tendency of programming would lead to
the less readable:
ZT(ZoneNum) = (CoefSumhat + CoefAirrat*(3.0*ZTM1(ZoneNum) –
1.5*ZTM2(ZoneNum) + .333333* ZTM3(ZoneNum))) &
/ (1.83333*CoefAirrat+CoefSumha)
The final version is a correct translation (more or less)
from the Engineering/usual representation but much harder to
look at in code and realize what is being represented.
Speed of Execution[LINK]
A critical consideration in speed of execution is
character string comparisons. These are typically
quite slow and should not be used in the core routines
(i.e. those that are executed every zone or hvac time step).
An alternative to string comparisons is to define module-level
integer parameters, equate a string to a parameter during the
initial subroutine call (e.g. GetInput), and then do integer
comparisons through the remainder of the calls to the module.
Doing this does not deter readability, yet assists in reducing
execution time.
For example, in the module shown previously (Module Fans),
the parameters for fan types are set as Integers:
!MODULE PARAMETER DEFINITIONS
INTEGER, PARAMETER :: FanType_SimpleConstVolume = 1
INTEGER, PARAMETER :: FanType_SimpleVAV = 2
INTEGER, PARAMETER :: FanType_SimpleOnOff = 3
INTEGER, PARAMETER :: FanType_ZoneExhaust = 4
During the GetInput, string types are shown (this is
getting these objects):
CALL GetObjectItem(‘FAN:SIMPLE:CONSTVOLUME’,
&
SimpFanNum,AlphArray, &
NumAlphas,NumArray,NumNums,IOSTAT)
. . .
Fan(FanNum)%FanName = AlphArray(1)
Fan(FanNum)%FanType = ‘SIMPLE’
. . .
Fan(FanNum)%Control = ‘CONSTVOLUME’
Fan(FanNum)%FanType_Num =
FanType_SimpleConstVolume
Then, during the simulation the integer parameters are
used:
! Calculate the Correct Fan Model with the current
FanNum
IF (Fan(FanNum)%FanType_Num = =
FanType_SimpleConstVolume) THEN
Call SimSimpleFan(FanNum)
Else IF (Fan(FanNum)%FanType_Num = = FanType_SimpleVAV)
THEN
Call SimVariableVolumeFan(FanNum)
Else If (Fan(FanNum)%FanType_Num = = FanType_SimpleOnOff)
THEN
Call SimOnOffFan(FanNum)
Else If (Fan(FanNum)%FanType_Num = = FanType_ZoneExhaust)
THEN
Call SimZoneExhaustFan(FanNum)
End If
This does not detract from code readability at all but
execution is much speedier with this versus the string
comparisons.
Code Readability vs. Speed of Execution[LINK]
Programmers throughout time have had to deal with speed of code execution and it’s an ongoing concern. However, compilers are pretty smart these days and, often, can produce speedier code for the hardware platform than the programmer can when he or she uses “speed up” tips. The EnergyPlus development team would rather the code be more “readable” to all than to try to outwit the compilers for every platform. First and foremost, the code is the true document of what EnergyPlus does – other documents will try to explain algorithms and such but must really take a back seat to the code itself.
However, many people may read the code – as developers, we should try to make it as readable at first glance as possible. For a true example from the code and a general indication of preferred style, take the case of the zone temperature update equation. In the Engineering Reference document, the form is recognizable and usual:
And, this equation appears in the code (ZoneTempPredictorCorrector Module), as:
ZT(ZoneNum) = (CoefSumhat + CoefAirrat*(3.0*ZTM1(ZoneNum) - (3.0/2.0)*ZTM2(ZoneNum) &
+ (1./3.)* ZTM3(ZoneNum))) &
/ ((11.0/6.0)*CoefAirrat+CoefSumha)
Somewhat abbreviated here due to lack of page width but still recognizable from the original. A better version would actually be:
ZT(ZoneNum) = (CoefSumhat - CoefAirrat*(-3.0*ZTM1(ZoneNum) + (3.0/2.0)*ZTM2(ZoneNum) &
- (1./3.)* ZTM3(ZoneNum))) &
/ ((11.0/6.0)*CoefAirrat+CoefSumha)
Whereas the natural tendency of programming would lead to the less readable:
ZT(ZoneNum) = (CoefSumhat + CoefAirrat*(3.0*ZTM1(ZoneNum) – 1.5*ZTM2(ZoneNum) + .333333* ZTM3(ZoneNum))) &
/ (1.83333*CoefAirrat+CoefSumha)
The final version is a correct translation (more or less) from the Engineering/usual representation but much harder to look at in code and realize what is being represented.
Speed of Execution[LINK]
A critical consideration in speed of execution is character string comparisons. These are typically quite slow and should not be used in the core routines (i.e. those that are executed every zone or hvac time step). An alternative to string comparisons is to define module-level integer parameters, equate a string to a parameter during the initial subroutine call (e.g. GetInput), and then do integer comparisons through the remainder of the calls to the module. Doing this does not deter readability, yet assists in reducing execution time.
For example, in the module shown previously (Module Fans), the parameters for fan types are set as Integers:
!MODULE PARAMETER DEFINITIONS
INTEGER, PARAMETER :: FanType_SimpleConstVolume = 1
INTEGER, PARAMETER :: FanType_SimpleVAV = 2
INTEGER, PARAMETER :: FanType_SimpleOnOff = 3
INTEGER, PARAMETER :: FanType_ZoneExhaust = 4
During the GetInput, string types are shown (this is getting these objects):
CALL GetObjectItem(‘FAN:SIMPLE:CONSTVOLUME’, &
SimpFanNum,AlphArray, &
NumAlphas,NumArray,NumNums,IOSTAT)
. . .
Fan(FanNum)%FanName = AlphArray(1)
Fan(FanNum)%FanType = ‘SIMPLE’
. . .
Fan(FanNum)%Control = ‘CONSTVOLUME’
Fan(FanNum)%FanType_Num = FanType_SimpleConstVolume
Then, during the simulation the integer parameters are used:
! Calculate the Correct Fan Model with the current FanNum
IF (Fan(FanNum)%FanType_Num = = FanType_SimpleConstVolume) THEN
Call SimSimpleFan(FanNum)
Else IF (Fan(FanNum)%FanType_Num = = FanType_SimpleVAV) THEN
Call SimVariableVolumeFan(FanNum)
Else If (Fan(FanNum)%FanType_Num = = FanType_SimpleOnOff) THEN
Call SimOnOffFan(FanNum)
Else If (Fan(FanNum)%FanType_Num = = FanType_ZoneExhaust) THEN
Call SimZoneExhaustFan(FanNum)
End If
This does not detract from code readability at all but execution is much speedier with this versus the string comparisons.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.