Standard EnergyPlus Units[LINK]
EnergyPlus expects information in a single unit system (SI). This requires interface developers to convert user inputs from those preferred by architects and engineers into the standard metric units of EnergyPlus. EnergyPlus will not perform any units conversions and will not have any unit conversion routines.
ASCII with no spaces is used for abbreviations. Note that exponents appear without any indication of exponentiation: i.e., kg/m3 not kg/m^3 or kg/m**3. Also note the use of dashes. We have W/m2-K not W/m2*K or W/(m2*K).
At the end we note the “problem” variables – the inputs that have non-standard units. Inputs using these units will have to be changed and the code checked to see how the quantities are used internally.
Standard EnergyPlus Units
angular degrees |
degree |
deg |
Length |
meter |
m |
Area |
square meter |
m2 |
Volume |
cubic meter |
m3 |
Time |
seconds |
s |
Frequency |
Hertz |
Hz |
Temperature |
Celsius |
C |
absolute temperature |
Kelvin |
K |
temperature difference |
Kelvin |
delK |
speed |
meters per second |
m/s |
energy (or work) |
Joules |
J |
power |
Watts |
W |
mass |
kilograms |
kg |
force |
Newton |
N |
mass flow |
kilograms per second |
kg/s |
volume flow |
cubic meters per second |
m3/s |
pressure |
Pascals |
Pa |
pressure difference |
Pascals |
delPa |
specific enthalpy |
Joules per kilogram |
J/kg |
density |
kilograms per cubic meter |
kg/m3 |
heat flux |
watts per square meter |
W/m2 |
specific heat |
———————————————————————— |
J/kg-K |
conductivity |
———————————————————————— |
W/m-K |
diffusivity |
———————————————————————— |
m2/s |
heat transfer coefficient |
———————————————————————— |
W/m2-K |
R-value |
———————————————————————— |
m2-K/W |
heating or cooling capacity |
Watts |
W |
electric potential |
volts |
V |
electric current |
Amperes |
A |
illuminace |
lux |
lx |
luminous flux |
lumen |
lm |
luminous intensity |
candelas |
cd |
luminance |
candelas per square meter |
cd/m2 |
vapor diffusivity |
m2/s |
|
viscosity |
———————————————————————— |
kg/m-s |
porosity |
———————————————————————— |
m3/m3 |
thermal gradient coeff for moisture capacity |
———————————————————————— |
kg/kg-K |
isothermal moisture capacity |
———————————————————————— |
m3/kg |
Standard EnergyPlus Units[LINK]
EnergyPlus expects information in a single unit system (SI). This requires interface developers to convert user inputs from those preferred by architects and engineers into the standard metric units of EnergyPlus. EnergyPlus will not perform any units conversions and will not have any unit conversion routines.
ASCII with no spaces is used for abbreviations. Note that exponents appear without any indication of exponentiation: i.e., kg/m3 not kg/m^3 or kg/m**3. Also note the use of dashes. We have W/m2-K not W/m2*K or W/(m2*K).
At the end we note the “problem” variables – the inputs that have non-standard units. Inputs using these units will have to be changed and the code checked to see how the quantities are used internally.
Documentation content copyright © 1996-2021 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.