Auxiliary Programs — EnergyPlus 24.2

<< Prev | Table of Contents | Object Index | Next >>

EnergyPlus File Extensions[LINK]

This section will present a list (perhaps not complete) of EnergyPlus file extensions and what they mean. This will help you after the EP-Launch program finishes.

Input Files[LINK]

The following files are input to the EnergyPlus program.

IDD[LINK]

The input data dictionary (IDD) is an ascii (text) file containing a list of all possible EnergyPlus objects and a specification of the data each object requires. This file is analogous to the DOE-2 keyword file. The Guide for Interface Developers contains a full description of the input data dictionary.

idf[LINK]

The input data file (IDF) is an ascii file containing the data describing the building and HVAC system to be simulated. Many example files are installed as part of the EnergyPlus installation. Additionally, a spreadsheet file “ExampleFiles.xls” contains columnar descriptions of each file’s features.

imf[LINK]

The input macro file (IMF) is an ascii file containing the data describing the building and HVAC system to be simulated and will have some contents of “macro” commands. The Auxiliary programs document describes use of the macro commands and the program that processes them - EP-Macro. Many example files are installed as part of the EnergyPlus installation.

ini[LINK]

This is the EnergyPlus initialization file. It is an optional ascii input file that allows the user to specify the path for the directory containing Energy+.idd. This file, using the actual directories of the install, will be created during the install. Unless you change where the EnergyPlus.exe file resides, you will not need to change this file.

epw[LINK]

The EnergyPlus weather file is an ascii file containing the hourly or sub-hourly weather data needed by the simulation program. The data format is described in detail in the Auxiliary Programs Document. It is also described succinctly in the Input Output Reference document.

Output Files[LINK]

More information (and more up-to-date) about output files is shown in the Output Details and Examples Document.

err[LINK]

A text file containing the error messages issued by EnergyPlus. This is the first output that should be examined after a simulation.Error messages may be issued by EnergyPlus during its input phase or during the simulation. There are three levels of error severity: fatal, severe, and warning as well as simple “message” lines. A fatal error causes the program to terminate immediately. The following table illustrates the necessary actions.

Error Message Levels - Required Actions
Error Level Action
Information Informative, usually a follow-on to one of the others. No action required.
Warning Take note. Fix as applicable.
Severe Should Fix
Fatal Program will abort

An example of an error message due to an input syntax error is:

** Severe  ** Did not find " DessignDay" in list of Objects
   **  Fatal  ** Errors occurred on processing IDF file -
       probable incorrect IDD file. View "audit.out" for details.
   ************* EnergyPlus Terminated--Error(s) Detected.

audit[LINK]

This is an text file which echoes the IDD and IDF files, flagging syntax errors in either file. Note that both err and audit will show most of the error messages caused by input syntax errors; however only err will show errors issued during the actual simulation. The audit can be used when you need to see the context of the error message to fully ascertain the cause. The audit file also contains potentially extra information that may be useful from the input scan.

eso[LINK]

The EnergyPlus Standard Output (ESO) is a text file containing the time varying simulation output. The format of the file is discussed in the Guide for Interface Developers and the InputOutputReference. The contents of the file are controlled by Output:Variable commands in the IDF file. Although the ESO is a text file, it is not easily interpretable by a human. Usually postprocessing will be done on this file in order to put it in a format that can be read by a spreadsheet; however a quick visual inspection of the file does show whether the expected variables are output at the desired time step.

mtr[LINK]

The EnergyPlus Meter Output (MTR) is a text file containing the time varying simulation output. The format of the file is similar to the ESO file. As described in the Getting Started document, meters are a powerful reporting tool in EnergyPlus. Values are grouped onto logical meters and can be viewed the same way that the ESO variables are used. The contents of the file are controlled by Output:Meter commands in the IDF file. Although the MTR is a text file, it is not easily interpretable by a human. Usually postprocessing will be done on this file in order to put it in a format that can be read by a spreadsheet; however a quick visual inspection of the file does show whether the expected variables are output at the desired time step.

mtd[LINK]

This file contains all the details (i.e., which report variables are on a meter and, conversely, what meters contain) about meters.

eio[LINK]

The EnergyPlus Invariant Output (EIO) is a text file containing output that does not vary with time. For instance, location information (latitude, longitude, time zone, altitude) appears on this file.

rdd[LINK]

mdd[LINK]

The Report (variable) Data Dictionary (RDD) is a text file listing those variables available for reporting (on the ESO) for this particular simulation. Which variables are available for output depends on the actual simulation problem described in the IDF. The Report (meter) Data Dictionary (MDD) is a text file listing those variables available for reporting (on the MTR) for this particular simulation. Which meters are available for output depends on the actual simulation problem described in the IDF. A simulation with no chiller would not permit the output of any chiller report variables. The user may need to examine the RDD or MDD to find out which report variables are available in a particular simulation. The RDD and MDD are written only if the following is included in the IDF file.

Output:VariableDictionary, Regular;

A variant produces the same files in a IDF “ready” format.

Output:VariableDictionary, IDF;

dbg[LINK]

This is a text file containing debug output for use by EnergyPlus developers. Generally developers will add debug print statements wherever in the code that that they wish. There is a “standard” debug output that prints out conditions at all the HVAC nodes. This output is triggered by placing

Output:DebuggingData,Yes;

in the IDF file. If Output:DebuggingData,No is entered, you will get an empty eplusout.dbg file.

dxf[LINK]

This is a file in AutoCad DXF format showing all the surfaces defined in the IDF file. It provides a means of viewing the building geometry. The DXF file from EnergyPlus highlights different building elements (shading, walls, subsurfaces) in differing colors. A number of programs can read and display DXF files. Output of this file is triggered by

Output:Reports, Surfaces, DXF;

in the IDF.

sln[LINK]

A text file containing the coordinates of the vertices of the surfaces in the IDF.

Output of this file is triggered by

Output:Reports, Surfaces, Lines;

in the IDF.

Postprocessing Program/Files[LINK]

A postprocessing program ReadVarsESO.exe is available that will read an ESO or MTR file and produce a file that can be read by ExcelTM. It can use an input file or not. In batch mode it is run by the little batch file RunReadESO.bat: Further information on this program is provided in the Input Output Reference under a section heading called “Using ReadVarsESO”. OutputControl:Files may also used to write CSV output (variables and meters) directly from EnergyPlus instead of using postprocessing.