The following background on building energy modeling (BEM)
will provide a foundation before learning the essentials of
EnergyPlus. If you are already familiar with BEM, you may wish
to skip to Section 1.4 describing the EnergyPlus QuickStart
Guide.
“Building
Energy Modeling (BEM) is the practice of using computer-based
simulation software to perform a detailed analysis of a
building’s energy use and energy-using systems. The simulation
software works by enacting a mathematical model that provides
an approximate representation of the building. BEM includes
whole-building simulation as well as detailed component
analysis utilizing specialized software tools that address
specific concerns, such as moisture transfer through building
materials, daylighting, indoor air quality, natural
ventilation, and occupant comfort. BEM offers an alternative
approach that encourages customized, integrated design
solutions, which offer deeper savings. Using BEM to compare
energy-efficiency options directs design decisions prior to
construction. It also guides existing building projects to
optimize operation or explore retrofit opportunities.”
Some other terms that are used to describe the same topic
are:
Building Simulation
Building Performance Simulation
Building Energy Simulation
Building Performance Modeling
Somewhat confusing, the term “model” can refer to both the
specific building being described and analyzed as well as
referencing the software for implementing a specific component
of the building such as a wall or chiller.
To learn more about building energy modeling consider
reviewing the following resources:
ASHRAE Standard
209 Energy Simulation Aided Design for Buildings Except
Low-Rise Residential Buildings
Study materials for the ASHRAE Building Energy Modeling
Professional (BEMP)
or AEE Building Energy Simulation Analyst (BESA)
professional certifications
Building
energy modeling is necessary to understand the overall energy
consumption in buildings, because, the energy flows in
buildings can be very complicated. The heat flow through walls
is determined not just by the area and the temperatures, but
the mass characteristics of the walls may result in heat
flowing out of a wall several hours after it has flowed in.
The constantly changing temperature on the outside of the wall
and the less frequent but often large step changes in
thermostat setpoints between day and night operation for the
inside of the building make the direction of the heat flow
vary over time. Solar energy is absorbed on the exterior wall
and roof surfaces as well as entering windows. The intensity
of solar energy varies by the sun position for each period of
time over the day and over the year. Heat sources within the
building including people, office and other equipment, and
lighting include both heat that immediately impacts the air
within (convective heat) and heat that is absorbed by the
surfaces and released slowly over time (radiant heat).
Lighting may be controlled by a sensor that turns it on or off
or changes its intensity based on the amount of natural
daylight that is entering the space through windows and
skylights making the heat generated from the lighting system
change over time. Air conditioning and heating systems come in
a huge number of configurations, and each one can be used with
many different control configurations based on the temperature
or other conditions within each space in the building, and
ultimately their operation accounts for a large portion of the
energy consumed in a building. For these reasons and more,
what might first appear as something that can be calculated
with just a few formulas in a spreadsheet is instead a
software program and, in the case of EnergyPlus, with over
500,000 lines of code.
The most common questions that BEM can answer are:
If my building was made or operated differently, how would
the required equipment capacity and energy consumption
change?
Does my building comply with a building energy code or
standard?
What kind of rating or how many points can I get in an
environmental certification program?
Is my building operating as it was designed to?
What is a good target for energy consumption for my
building?
These questions and more can occur at different times
during the life-cycle of a building, from before schematic
design all the way through the rest of the design process, and
into the operation of the building
Building
energy modeling can be used throughout the design process for
a new building or when considering updates to existing
buildings. It can also be used later in the life-cycle of a
building related to comparing actual operation of the building
with the predicted operation. ASHRAE Standard
209 titled “Energy Simulation Aided Design for Buildings
Except Low-Rise Residential Buildings” is a critical document
in how to apply building energy modeling. It describes a
methodology to apply building energy modeling to the design
and was created to define reliable and consistent procedures
that advance the use of timely energy modeling to quantify the
impact of design decisions at the point in time which they are
made. The standard includes different “Modeling Cycles” for
different stages of using building energy modeling during the
life-cycle of the building:
Modeling Cycle #1 – Simple Box Modeling
Modeling Cycle #2 – Conceptual Design Modeling
Modeling Cycle #3 – Load Reduction Modeling
Modeling Cycle #4 – HVAC System Selection Modeling
Modeling Cycle #5 – Design Refinement
Modeling Cycle #6 – Design Integration and
Optimization
Modeling Cycle #7 – Energy Simulated-Aided Value
Engineering
Modeling Cycle #8 – As-Designed Energy Performance
Modeling Cycle #9 – Change Orders
Modeling Cycle #10 – As-Built Energy Performance
Modeling Cycle #11 – Postoccupancy Energy Comparison
In addition, it has information about how to integrate
climate and site analysis, benchmarking, energy charrettes (a
meeting of the stakeholders to discuss goals and design
strategies) and the energy performance goals of the owners
project requirements into the design process when using
building energy modeling.
Don’t be intimidated by the apparent complexity of
EnergyPlus; you can get started using EnergyPlus quickly using
the QuickStart Guide which is part of the documentation. It
shows you how you can use just an input file and some output
files to start seeing results quickly. The building
description, the detecting and solving of errors, and the most
common primary outputs are found in the IDF input file, the
Table.HTML output file and the .ERR diagnostics file. Starting
with these three files and branching out to others as needed
is a good strategy for learning EnergyPlus.
“EnergyPlus is a whole building energy simulation program
that engineers, architects, and researchers use to model both
energy consumption—for heating, cooling, ventilation, lighting
and plug and process loads—and water use in buildings. Some of
the notable features and capabilities of EnergyPlus
include:
Integrated, simultaneous solution of thermal zone
conditions and HVAC system response that does not assume that
the HVAC system can meet zone loads and can simulate
un-conditioned and under-conditioned spaces.
Heat balance-based solution of radiant and convective
effects that produce surface temperatures, thermal comfort,
and condensation calculations.
Sub-hourly, user-definable time steps for interaction
between thermal zones and the environment; with automatically
varied time steps for interactions between thermal zones and
HVAC systems. These allow EnergyPlus to model systems with
fast dynamics while also trading off simulation speed for
precision.
Combined heat and mass transfer model that accounts for
air movement between zones.
Advanced fenestration models including controllable window
blinds, electrochromic glazings, and layer-by-layer heat
balances that calculate solar energy absorbed by window
panes.
Illuminance and glare calculations for reporting visual
comfort and driving lighting controls.
Component-based HVAC that supports both standard and novel
system configurations.
A large number of built-in HVAC and lighting control
strategies and an extensible runtime scripting system for
user-defined control.
Functional Mockup Interface import and export for
co-simulation with other engines.
Standard summary and detailed output reports as well as
user definable reports with selectable time-resolution from
annual to sub-hourly, all with energy source
multipliers.”
In addition:
ASCII text-based weather, input, and output files that
include hourly or sub-hourly environmental conditions, and
standard and user definable reports, respectively.
Transient heat conduction through building elements such
as walls, roofs, floors, etc. using conduction transfer
functions.
Thermal comfort models based on activity, inside dry-bulb
temperature, humidity, etc.
Anisotropic sky model for improved calculation of diffuse
solar on tilted surfaces.
Atmospheric pollution calculations that predict CO2, SOx,
NOx, CO, particulate matter, and hydrocarbon production for
both on-site and remote energy conversion.
EnergyPlus can be used for for building load calculations
and sizing equipment and uses the heat balance method
recommended in the ASHRAE
Handbook Fundamentals. Proper sizing of equipment without
oversizing, generally saves energy as the equipment is
operated nearer to optimal loads.
EnergyPlus runs on Windows, MacOS, and Linux
computers.
Integration of Loads, Systems, and Plants: One of the
strong points of EnergyPlus is the integration of all aspects
of the simulation—loads, systems, and plants. System and plant
output are allowed to directly impact the building thermal
response rather than calculating all loads first, then
simulating systems and plants. The simulation is coupled
allowing the designer to more accurately investigate the
effect of undersizing fans and equipment and what impact that
might have on the thermal comfort of occupants within the
building.
EnergyPlus is an Open Source program so all
the source
code is available to inspect and modify. If you are
interested in how calculations are performed and the Engineering
Reference does not provide enough details to you, you can
review the source code itself. Instructions
to build the code (compile the source code into an
executable application) are available in the source code
repository wiki if you see something that needs to be enhanced
or fixed, please also see the contribution
policy.
EnergyPlus has been under development since 1997 and was
first released in 2001. EnergyPlus has its roots in both the
BLAST and DOE–2 programs. BLAST (Building Loads Analysis and
System Thermodynamics) and DOE–2 were both developed and
released in the late 1970s and early 1980s as energy and load
simulation tools. BLAST was developed by the [Construction](../input-output-reference/group-surface-construction-elements.html#construction-000)
Engineering Research Laboratory (CERL) and the University of Illinois
while DOE-2 was developed by Berkeley Lab and many others.
Their intended audience is a design engineer or architect that
wishes to size appropriate HVAC equipment, develop retrofit
studies for life cycling cost analyses, optimize energy
performance, etc. Born out of concerns driven by the energy
crisis of the early 1970s and recognition that building energy
consumption is a major component of the American energy usage
statistics, the two programs attempted to solve the same
problem from two slightly different perspectives. In the late
1990s, concern about limitations of both BLAST and DOE-2 as
well as difficulty in maintaining the old code bases prompted
combining the development efforts for a new program called
EnergyPlus. EnergyPlus was originally written in Fortran, in
2014 it was converted to C++. It was developed as a simulation
engine, and many graphical
user interfaces utilize it.
The EnergyPlus documentation is currently included in the
installation in the “Documentation” folder as PDFs. It is also
available as PDFs online
and from third parties that have generated HTML documentation
from the source. Using search in the documentation is critical
to finding the information needed. Some of the documentation
PDFs are very large, so searching is a good way to find
specific information about a topic or an input object. The
documentation includes:
QuickStart Guide: Contains a brief high-level overview of
EnergyPlus and get you up and running quickly with the
program
Input Output Reference: Contains a thorough description of
the various input and output files related to EnergyPlus, the
format of these files, and how the files interact and
interrelate.
Output Details and Examples: Contains details on output
from EnergyPlus. It also addresses the reference data sets
that are included.
Auxiliary Programs: Contains information for the auxiliary
programs that are part of the EnergyPlus package. For example,
this document contains the user manual for the Weather
Converter program, descriptions on using Ground Heat Transfer
auxiliary programs with EnergyPlus, and other assorted
topics.
Engineering Reference: Provides more in-depth knowledge
into the theoretical basis behind the various calculations
contained in the program including algorithm
descriptions.
Application Guide for EMS: Provides an in-depth look at
the Energy Management System (EMS) feature which provides a
way to develop custom control and modeling routines.
External Interface(s) Application Guide: Contains
information specific to using the external interface feature
of EnergyPlus to connect other simulation systems.
Plant Application Guide: Details the methods for
simulating chilled and hot water plant systems within
EnergyPlus.
Using EnergyPlus for Compliance Guide: Contains
information specific to using EnergyPlus in compliance and
standard rating systems.
Tips & Tricks for Using EnergyPlus: Contains short
tips and tricks for using various parts of EnergyPlus.
Many hundreds of example files come with EnergyPlus, and
they are in the ExampleFiles folder from the installation. The
\ExampleFiles\ExampleFiles.html lists each one and includes
the name, a description (scroll all the way to the right) and
lots of information such as the floor area and whether certain
types of input objects are included in the file. Often
searching through this file is a good way to find the proper
example file to learn about a feature. Another method is the
\ExampleFiles\ExampleFiles-ObjectsLink.html file which lists
every type of input object that EnergyPlus uses and then the
first three files that use that input object. It is possible
that many other files also use a particular input object so if
the first three files do not help, a text search of files in
the ExampleFiles folder may find more.
EnergyPlus is often used directly using the text file input
(IDF or epJSON) and various output file formats along with the
utilities that come with the installation package. More
information on that can be found in section [sec:Using-EnergyPlus]. In
addition, EnergyPlus is often the simulation engine for
graphical user interfaces. To see a list, see the BEST
(Building Energy Software Tools) Directory that is
operated by IBPSA-USA.
In the terminology used within the building energy modeling
industry “measures,” sometimes called energy conservation
measures (ECMs) or energy efficiency measures (EEMs), are when
alternative configurations of a building are considered and
simulated and compared with the original building model.
Measures include added wall or roof insulation, lower internal
lighting power, higher efficiency heating and cooling
equipment, and many others. When using EnergyPlus within a
graphical user interface, that interface often provides a way
to implement various measures. When not working within a
graphical user interface, users have several options for
implementing measures.
For a specific building input file, a copy of the input
file can be made and then modified to reflect the measure.
This is an easy approach initially, but since the original
building model might change, it means making the change in the
file that reflects the measure. When many measures are being
considered, this duplicative editing can be inefficient and
prone to errors. In addition, the measure cannot be easily
applied to a different building energy model without again
editing another set of files duplicating the original effort.
Due to this, it is very common for some type of scripting to
be used so that measures can be applied to the original
building model and other models of other buildings reliably
and quickly. Scripting in this approach means to apply some
type of programming language to the task of modifying
files.
EnergyPlus includes, with the installation package, two
methods of implementing measures EP-Macro and the
ParametricPreprocessor. EP-Macro is similar to the C language
pre-processor and allows for portions of the file to be
included or excluded, portions of other files to be included
when desired, and for specific entries that are normally fixed
values to change programmatically. EP-Macro is documented in
the AuxiliaryPrograms documentation. A file with lines
starting “##” or with the “imf” file extension is likely to be
a file using EP-Macro commands.
The EnergyPlus ParametricPreprocessor uses special input
objects in EnergyPlus to set values for any field in any other
input object for a series of simple options. This is briefly
described in the AuxiliaryPrograms documentation, and more
details are present in the InputOutputReference under the
section on “Parametric Objects.” The ParametricPreprocessor
approach is very straight forward, however it has limits in
the flexibility that it provides. It is suitable for
implementing measures related to internal loads,
constructions, and simple efficiency changes but is probably
not the appropriate tool for more complicated measures.
A paper
that describes various other approaches to scripting was
written during the 2018 ASHRAE/IBPSA-USA Building
Performance Conference and SimBuild.
When just implementing a simple measure or even a series of
measures is not enough, a parametric analysis tool may be
appropriate. These tools allow the exploration throughout the
range of variables (such as the thickness of insulation in the
roof or the efficiency of a boiler) to see the impacts of
optimization. While many of the approaches used to implement
measures described previously may also be used for parametric
analysis, a few specific tools have been developed. To see a
list, see the BEST
(Building Energy Software Tools) Directory that is
operated by IBPSA-USA.
Weather files are available for many locations throughout
the world. Finding the right file that represents the weather
in your specific location can sometimes be a challenge. Often
the closest weather location is the best one to choose, but
sometimes a site that is further away may actually have the
most similar weather. This is especially the case in terrain
that varies in elevation or when near large bodies of water.
Many weather files are available from both public and private
sources. The EnergyPlus weather
file web site has many weather files with sources
described. That web site also has a page with
links to many other sites that provide weather files. The
modeler must also choose between using a typical year weather
files or an actual year file. Typical year files, such as TMY3
and IWEC are representative of long-term weather compiled from
20-30 years of data. Actual year files contain a specific year
of weather data and generally used for calibration or
verification studies where the simulation results are compared
to actual utility bills or other measured data.
The modelling of multi-domain, multi-physics, and
multi-time scale systems such as buildings is a challenge for
building energy modelling and simulation tools. In certain
circumstances, it may be better for modelling such systems to
split the systems into multiple sub-systems, model the
individual sub-systems in the language or tool which is best
suited for the system’s domain, and use a master algorithm to
link the sub-systems for a so called “co-simulation.” In a
nutshell, co-simulation consists of the theory and techniques
that enable the simulation of a coupled system through the
composition of simulators. Each simulator is an input-output
mock-up of a constituent system, developed and provided by the
team that is responsible for the sub-system. The
coupling of the sub-systems is performed by a master algorithm
which is responsible for linking the sub-systems at run-time
for data-exchange. EnergyPlus implements three mechanisms to
support co-simulation.
EnergyPlus implements the Building Controls Virtual Test
Bed ( BCVTB)
API. This API leverages the BCVTB to enable the co-simulation
of EnergyPlus with various simulation programs such as TRNSYS, ESP-r,
Radiance,
or DYMOLA.
EnergyPlus provides an interface which allows it to
import, link, and exchange data with simulation models which
implement the Functional Mock-up Interface (FMI) for co-simulation.
Such models are called Functional Mock-up Units (FMUs). This
feature allows for instance the integration and testing of Simulink or Modelica-based control
algorithms which may not exist in EnergyPlus.
EnergyPlus itself can be exported as an FMU which
implements the FMI
for co-simulation. Such FMU can then be imported into any
simulation engine which implements the FMI import interface
for co-simulation. This feature is relevant for applications
such as the development of building controls. For example, the
building envelope of EnergyPlus may be exported as an FMU
which in turn will be imported in a tool which is best suited
for control development. In this use case, the FMU will be
used as a boundary condition for control’s development.
Please do not post questions as issues on the EnergyPlus
Github website. Of course, if you are using a graphical user
interface with EnergyPlus, the vendor will provide direct
support.
After reviewing this document and other pertinent documents
that come with EnergyPlus like the InputOutputReference, if
additional training is required, several sources are
available:
EnergyPlus is a simulation engine, so it was designed to be
an element within a graphical user interface. However, it can
be run standalone without such an interface. There are several
options for performing a simulation with EnergyPlus:
Graphical user interface
Command line
EP-Launch
In each case, a building model will be simulated in
combination with a weather file for the appropriate building
location.
When running an EnergyPlus simulation within a graphical
user interface, the exact method will vary depending on the
specific program being used. You should read the documentation
for that software to understand how to perform a simulation.
In all cases, the interface will ultimately generate an
EnergyPlus idf or epjson input file, execute the EnergyPlus
simulation, and read the EnergyPlus output files to present
results.
EnergyPlus can be used as a command line tool within a
Terminal window in Linux or MacOS or with the CMD prompt or
PowerShell window under Windows. Basic usage using the command
line approach is well documented in the QuickStart Guide. To
learn more about the command line mode, you can type:
energyplus --help
when in the EnergyPlus folder. This will give the following
display of options:
EnergyPlus, Version 9.6.0-ec0190a2fc
Usage: energyplus [options] [input-file]
Options:
-a, --annual Force annual simulation
-c, --convert Output IDF->epJSON or epJSON->IDF, dependent on
input file type
-d, --output-directory ARG Output directory path (default: current
directory)
-D, --design-day Force design-day-only simulation
-h, --help Display help information
-i, --idd ARG Input data dictionary path (default: Energy+.idd
in executable directory)
-j, --jobs ARG Multi-thread with N threads; 1 thread with no
arg.
-m, --epmacro Run EPMacro prior to simulation
-p, --output-prefix ARG Prefix for output file names (default: eplus)
-r, --readvars Run ReadVarsESO after simulation
-s, --output-suffix ARG Suffix style for output file names (default: L)
L: Legacy (e.g., eplustbl.csv)
C: Capital (e.g., eplusTable.csv)
D: Dash (e.g., eplus-table.csv)
-v, --version Display version information
-w, --weather ARG Weather file path (default: in.epw in current
directory)
-x, --expandobjects Run ExpandObjects prior to simulation
--convert-only Only convert IDF->epJSON or epJSON->IDF,
dependent on input file type. No simulation
Example: energyplus -w weather.epw -r input.idf
EnergyPlus can be run by specifying a number of options
followed by the path to the input file. The file itself is
usually in IDF (Input Data File) format or epJSON format, but
it may also be in IMF (Input Macro File) format to be run with
EPMacro using the --epmacro option. Each option has a short
form (a single-character preceded by a single dash, e.g., -h)
and a long form (a more descriptive string of characters
preceded by double dashes, e.g., --help). Several of these
options are commonly used including the weather,
output-prefix, expandobjects, and readvars options. The
following are some examples of using the command line
options.
Pre-processing using EPMacro and ExpandObjects:
energyplus -w weather.epw -m -x input.imf
Forcing design-day only simulations:
energyplus -D input.idf
Giving all output files the prefix being the same as the
input file (building.idf) and placing them in a directory
called output:
energyplus -w weather -p building -d output building.idf
If no arguments are passed on the command line, EnergyPlus
expects the input and weather files to be located in the
current working directory and name in.idf (or in.epjson) and
in.epw respectively.
For users that want a simple way of selecting files and
running EnergyPlus, EP-Launch provides this and more. In
addition, EP-Launch can help open a text editor for the input
and output files, open a spreadsheet for the result files, a
web browser for the tabular results file, and start up a
viewer for the selected drawing file. There are two different
versions of EP-Launch currently part of the EnergyPlus
system.
The main screen of EP-Launch 2 is shown below:
EP-Launch 2
It is a Windows program only. EP-Launch 2 is included in
the EnergyPlus installation package when installing on
Windows, so no additional steps are needed to run it. It is
located in the main “root” folder of EnergyPlus, usually, a
folder named EnergyPlusVx-x-x, where the x’s are the version
number.
In 2018, EP-Launch 3 was developed, and its main screen is
shown below:
EP-Launch 3
EP-Launch 3 is not part of the EnergyPlus installation
package and needs to be installed separately. It is also open
source and is available from GitHub,
and it is documented on readthedocs
or in the docs folder on GitHub. EP-Launch 3 works on Windows,
MacOS, and Linux systems and is written in Python.
While both EP-Launch 2 and EP-Launch 3 do many of the same
functions, the interface is quite different. For now,
EP-Launch 2 allows groups of files to be run together and has
access to some utilities that the newer version does not.
EP-Launch 3 works across multiple platforms and is a built
from the ground up to be flexible and extensible so that
individuals can make their own workflows that run whatever
programs they need to run.
EnergyPlus has two different input file formats that can be
used to describe the building and system that is simulated.
The file extensions for the two formats are IDF and epJSON.
For both input files, the numeric inputs are in SI units
(International System of Units often called metric units).
The legacy file format is a text-based format that
describes each input object in series. Each input object
starts with the type of input object, and each value for each
field follows in strict order separated by commas. The end of
the input object is indicated by a semi-colon. Comments are
indicated by an exclamation point “!” and anything after this
is ignored by EnergyPlus. Commonly, an input object is spread
over many lines in the file with one value for each field per
line. The names of each field are not required but are usually
shown after the value and the comma or semicolon as a special
comment using “!-” as an indicator. The input objects can be
in any order. An example of an input object in an IDF file is
shown below:
Building,
Simple One Zone, !- Name
0, !- North Axis {deg}
Suburbs, !- Terrain
0.04, !- Loads Convergence Tolerance Value
0.004, !- Temperature Convergence Tolerance Value {deltaC}
MinimalShadowing, !- Solar Distribution
30, !- Maximum Number of Warmup Days
6; !- Minimum Number of Warmup Days
The details of this example input object are not important,
but the use of commas, exclamation points, and the closing
semi-colon are important. The IDF format is currently the most
commonly used format throughout the EnergyPlus ecosystem of
utilities and GUIs. The list of possible input objects and
fields is documented in the Energy+.idd file.
A variation on the IDF file format is the IMF file format
which includes macros that can be used for parametric analysis
or file management called EP-Macros. To learn more about
macros see the Input Macros chapter of the AuxiliaryPrograms
document.
A new file format based on the industry standard JSON format most often used
to transmit data to and from web servers and web-browser based
applications. It is a text-based file format. The JSON format
has wide usage across many industries and is supported in just
about every modern programming language. It is a field-value
style format using brackets and colons to indicate the
hierarchy and commas to separate each field and value pair.
The input objects must appear grouped by the type of input
object. The list of possible input objects and fields is
documented in the Energy+.schema.epJSON file which uses json-schema. The same input
object shown above in IDF format is shown below in epJSON
format:
While the IDF and epJSON file formats are quite different,
they contain the same information, and either may be used. In
general, if producing EnergyPlus input files using a
programming language, the epJSON format might make more sense
while, at this point, if producing IDF files using a GUI, they
are likely to use the IDF format.
EnergyPlus, when used on the command line, can convert from
IDF to epJSON and from epJSON to IDF using the -c or --convert
option.
There is also a separate conversion utility
ConvertInputFormat.exe in the root EnergyPlus folder. It takes
the name of an IDF or epJSON input file (with extension) as an
argument. For additional options, type
ConvertInputFormat --help.
when in the EnergyPlus folder. This will give the following
display of options:
Usage: ConvertInputFormat [OPTIONS] input_file [input_file ..]
Options:
-f, --format ARG Output format.
Default means IDF->epJSON or epJSON->IDF
Select one (case insensitive):
default,idf,epjson,json,cbor,msgpack,ubjson,bson
-h, -help, --help, --usage Display usage instructions.
-i, --input ARG Text file with list of input files to convert
(newline delimited)
-j ARG Number of threads
-n, --noHVACTemplate Do not convert HVACTemplate objects.
-o, --output ARG Output directory. Will use input file
location by default.
-v, --version Display version information
Example: ConvertInputFormat in.idf
On Windows, you can also drag a file (IDF or epJSON) onto
ConvertInputFormat.exe. Note that ConvertInputFormat is
version-specific and will not convert an epJSON file that is
not the same version.
There are three groups of special input objects which are
preprocessor commands: GroundHeatTransfer:*, HVACTemplate:*
Parametric:*. ConverInputFormat converts HVACTemplate objects.
EnergyPlus does not convert any of these.
Since both the IDF and epJSON file formats are text
formats, a simple text editor may be used to edit them. Even
if not regularly used, a good text editor is an important
application to have when working with EnergyPlus. There are
many different text
editors, and a few have special features related to the
IDF format such as syntax highlighting including Atom,
Notepad++,
and UltraEdit.
Another editing choice for IDF file is the IDF Editor which
comes with EnergyPlus in the \PreProcess\IDFEditor directory
and can be run directly or from EP-Launch. It is a
Windows-only program and was not designed to run on Linux or
MacOS. It is specially designed for editing IDF files and
includes many features to simplify the process. It performs
unit conversions so either SI (metric) or IP (inch-pound)
units can be used for editing but the IDF file is always saved
in SI units. It can initialize an input object using the
default values and has indications when values outside the
acceptable range are used. The main screen of the IDF editor
is shown below. Full details of the IDF Editor can be found in
the Auxiliary Programs document under the “Creating Input
Files” section.
For most building energy modeling projects, whether
assisting in early design, refining a design, selecting a
control method, or calibrating an existing building, the use
of EnergyPlus will be part of a repeating process. The process
will probably be in the form of:
Running an EnergyPlus input file
Checking error and other output files
Fixing the input file
Repeat
Don’t expect that an initial model is ever correct; it is
probably not. Initially, errors are likely to exist. The .ERR
file should be the first file checked each time EnergyPlus is
run. The .ERR file has several levels of messages:
Warning
Severe
Fatal
A Fatal error means that EnergyPlus has stopped during the
simulation and the input file needs to be fixed before the
simulation can be run to completion. Fatal errors should be
the first thing fixed. Some Fatal messages reference previous
Severe messages so in that case those should be fixed. Since
the entire simulation was not performed, it is likely that
once the fatal errors are fixed that new Severe and Warning
messages will be shown. After all Fatal messages are
eliminated, you should work on Severe messages; they should
also be fixed. Finally, Warning messages should be reviewed.
Often Warning messages are informative and point out unusual
configurations, conditions, or choices. If what is being
described by the Warning message is as intended, then the
Warning message can be ignored. More often, the Warning
message points out something that is not as intended and
should be fixed or addressed. Since the .ERR file is a text
file; you can usually keep it open in a text editor program.
Many (but not all) text editor programs will detect that the
.ERR file has been updated after each EnergyPlus simulation
and lets you load the most recent version.
The next files to be examined are ones that show output
results from the simulation. Either the tabular output file
(usually an HTML file see Output:Table:SummaryReports
and OutputControl:Table:Style) or CSV file (see Output:Variable
and Output:Meter) should be examined depending on what you
want to look at. Upon examination of the output results, it is
very likely that an aspect of the building and its systems are
not behaving as expected. For example, the Annual Building
Utility Performance Summary report contains a subtable titled
Comfort and Setpoint Not Met Summary. If an annual simulation
has 100s or 1000s of hours of setpoint not met, then the HVAC
system is undersized, or the controls are not working as
expected. With an input file representing many thousands of
assumptions, some assumptions made by you or as a default of
EnergyPlus are likely to be incorrect. Revising the EnergyPlus
input file to address this may cause new issues to be shown in
the .ERR file so it should always be examined after
each change.
To speed the process of running the simulations, you may
want only to run a design day (see SimulationControl
and SizingPeriod:DesignDay) or a subset of the year (see
RunPeriod) while developing and debugging the inputs. This
approach speeds up the simulation time itself, and if used,
please remember to recheck the .ERR file when running an
annual simulation for the first time.
One principal that EnergyPlus uses is that (almost)
everything is specified in the input file. This means that
instead of referencing an external library for materials,
schedules, equipment performance, etc., the input objects that
fully describe those items should be included directly in the
input file. In addition, each input object contains a list of
values for every field that needs one. The DataSets folder
distributed with EnergyPlus contains these kinds of details
and to use them, the input objects should be copied into the
input file that you are developing. This approach does make
the file include more specification than you might be used to,
and typically results in a large input file, but you will have
the assurance of knowing that all the inputs related to your
building are in the input file you have developed. There are a
few exceptions where external data is referenced such as with
Schedule:File
input objects.
Exterior and interior walls in real buildings have a
thickness as specified on building plans by detailed
cross-sections. For EnergyPlus, the Construction
input object is made up of a list of names for the Material
input objects that make up the wall or roof or floor. Each
material input object has a thickness along with the
conductivity, density, specific heat and other factors. These
thicknesses should match the thicknesses shown in the detailed
cross-sections. But when it comes to specifying the walls
themselves in three-dimensional space, the walls should be
entered assuming zero thickness. Once each surface has been
placed, changing the material thickness will have no impact on
zone volume, ceiling height, floor area, shading, or
daylighting. For most modern buildings the choice of where to
locate the wall: inside vs. outside vs. centerline should have
little impact on results, so many modelers just pick one and
let the volumes be slightly off. Using centerlines throughout
the model splits the difference. Or some modelers use outer
edges for exterior walls and then use centerlines for interior
walls. If you are modeling a very thick wall, such as an old
stone building, then you also have thermal mass
considerations. If you use the outside edges there will be too
much mass, inside will be too little. Again, centerline will
split the difference and will be very close to the correct
amount of thermal mass (possibly losing some corner mass).
A zone, sometimes called a “thermal zone,” is a theoretical
construct that usually describes a group of rooms that can be
treated as a single thermal entity. A zone typically includes
multiple rooms. Often a zone can be seen as a group of rooms
that share a single thermostat. In the case of many similar
rooms with the same thermal and operating characteristics,
even if many different thermostats are used, they may still be
grouped into a single zone in EnergyPlus.
Only one type of construction can be associated with each
surface so if the top half of a wall is made up of a different
construction than the bottom half of the wall, the top half
and the bottom half each need to be represented as separate
surfaces.
Available
Outputs Created by First Simulation[LINK]
Since EnergyPlus creates a custom list of possible output
variables during each simulation, you need to perform a
simulation first before you can see them. To create the list
use the Output:VariableDictionary
input object and then check the .RDD and .MDD files that are
created. Select the outputs you want and specify them in the
input file.
Some preliminary steps will facilitate the construction of
your input file. EnergyPlus requires some information in
specified, externally available formats; other information may
require some lead time to obtain. The following checklist
should be completed before you start to construct your input
file.
Obtain location and design climate information for the
city in which your building is located. If possible, use one
of the weather files available for your weather period
run.
Obtain sufficient building construction information to
allow specification of overall building geometry and surface
constructions (including exterior walls, interior walls,
partitions, floors, ceilings, roofs, windows, and doors).
Obtain sufficient building use information to allow
specification of the lighting and other equipment (e.g.,
electric, gas, etc.) and the number of people in each area of
the building.
Obtain sufficient building thermostatic control
information to allow specification of the temperature control
strategy for each area of the building.
Obtain sufficient HVAC operation information to allow
specification and scheduling of the fan systems.
Obtain sufficient central plant information to allow
specification and scheduling of the boilers, chillers and
other plant equipment.
Obtain utility tariff information when expressing the
results as costs.
Obtain component cost information when performing
life-cycle costs.
The installation of EnergyPlus includes many different
files in different folders:
EnergyPlus Installation Folders
Many of these folders include valuable resources for using
and learning EnergyPlus.
The main folder includes the EnergyPlus executable which
can be used on the command line and EP-Launch 2, a program
that makes it easier to use EnergyPlus and the Energy+.IDD
that describes each possible EnergyPlus input object and the
default, minimum, maximum, and options for each field within
each input object.
The Documentation folder includes this document as well as
the InputOutputReference, EngineeringReference,
AuxiliaryPrograms, OutputDetailsAndExamples which are very
important to understand. If you haven’t looked through the
documentation yet, take a few minutes and get familiar with
it.
The DataSets and MacroDataSets folders include files
containing libraries of input objects that may be useful in
constructing your own input files. The
ASHRAE_2005_HOF_Materials.idf and WindowConstructs.idf files,
for example, will help with defining walls and windows.
The ExampleFiles folder includes a huge number of example
files that are indexed in the two HTML files in that folder or
can be searched through using most text editors.
The Preprocess and PostProcess folders include many
utilities that can be used directly or as part of EP-Launch
that can aid in the setting up input files or extracting or
converting results. The WeatherData folder includes a small
sample of the many weather files that are available. For other
weather files, please see the previous section on [subsec:Weather-Files].
When running EnergyPlus using EP-Launch or from the command
line, depending on the options selected, many different output
files may be generated. The file extensions and file suffixes
(added to the original file name prior to the file extension
are shown below:
ERR – list of errors and warnings
TABLE.HTML, TABLE.TXT, TABLE.TAB, TABLE.CSV, TABLE.XML –
tabulated report of the bin and monthly data in HTML, space
delimited, tab delimited, comma delimited, or XML format. This
is one of the primary output files.
CSV, TAB, or TXT – time series output from the
Output:Variable input object in a comma, tab, or space
delimited format (generated by the ReadVarsESO postprocessor
or directly from EnergyPlus using OutputControl:Files)
METER.CSV, METER.TAB, or METER.CSV File – time series
output from the Output:Meter input object in a comma, tab, or
space delimited format (generated by the ReadVarsESO
postprocessor or directly from EnergyPlus using
OutputControl:Files)
SQL - sqlite3 output database format
EIO – additional EnergyPlus results
RDD – list of output variables available from the run
MDD – list of output meters available from the run
MTD – list of meter component variables
DXF – drawing file in AutoCAD DXF format
AUDIT – input file echo with input processor errors and
warnings
BND – HVAC system node and component connection
details
DBG – output from the debug command
EDD – Energy Management System details
END - a single line synopsis of the simulation
EPMIDF – clean idf file after EP-Macro processing
EPMDET – EP-Macro detailed output with errors and
warnings
ESO – raw Output:Variable output before processing into
CSV, TAB, or TXT files
MTR – raw Output:Meter output before processing into CSV,
TAB, or TXT files
SHD – output related to shading
SLN – output from “report, surfaces, lines”
SSZ – system sizing details in a comma, tab, or space
delimited format
ZSZ – zone sizing details in a comma, tab, or space
delimited format
RVAUDIT - output from the ReadVarsESO post-processing
program
SVG - HVAC Diagram related to the arrangement of HVAC
components
SCI - surface cost information report
WRL – drawing file in VRML (Virtual Reality Markup
Language) format
Delight IN - DElight input generated from EnergyPlus
processed input
Delight OUT – Detailed DElight output
Delight ELDMP – DElight reference point illuminance per
time step
Delight DFDMP – DElight warning and error messages
EXPIDF – Expanded IDF when using HVACTemplate input
objects
Group Error – combined error files for a group run
VCpErr – Transition program error file
Proc.CSV – Simple statistics generated from CSVProc
Most of these output files are documented in the Output
Files chapter of the OutputDetailsAndExamples document.
Don’t be intimidated by the long list of files; you can do
a lot in EnergyPlus with just the IDF input file, the
TABLE.HTML file, and the ERR file. The building description,
the detecting and solving of errors, and the most common
primary outputs are found between these three files. Starting
with these three files and branching out to others as needed
is a good strategy for using EnergyPlus.
EnergyPlus version updates are released generally twice per
year in March and September. Each version of EnergyPlus is
installed to a unique folder, so it is possible, and
recommended, to keep older versions in place when adding a new
one. This is very helpful if you need to go back and make a
change to an older project and don’t want to introduce
version-related changes in results. When using the IDF input
file format with EnergyPlus, each release is likely to have
small changes to the file format. Included with EnergyPlus are
a number of ways to update files so that they are compatible
with the release. Each method ultimately uses the
TransitionVx-x-x-ToVx-x-x.exe files that are located in the
Preprocess\IDFVersionUpdater folder. The ways to update your
IDF files are:
IDFVersionUpdater program (shown below) is included in the
installation and works on multiple platforms. It is located in
the Preprocess\IDFVersionUpdater folder. It can convert from
EnergyPlus 7.2 to the most recent version, and even older
versions can be converted if the proper files are requested
from the helpdesk. It
can also update a group of files. It is documented in the
Chapter titled “Using Older Version Input Files - Transition”
in the AuxiliaryPrograms document.
IDFVersionUpdater
EP-Launch 2 - The Windows-only program that comes with the
EnergyPlus installation can update a single file from the just
previous version of EnergyPlus by using the File...Transition
command.
EP-Launch 3 - The program for Windows, Linux, and MacOS
can update a single file across multiple versions using the
Transition workflow.
Command line Transition - This allows updating files using
the command line such as the Terminal for MacOS and Linux or
the CMD or PowerShell for Windows. It is documented in the
Chapter titled “Using Older Version Input Files - Transition”
in the AuxiliaryPrograms document.
As described in the section dealing with errors described
in the ERR file are part of creating files with EnergyPlus.
Resolving errors is something that both new and very
experienced users have to do. Most of the error message
itself, if carefully reviewed will point to the problem. Some
error messages will also reference earlier messages that
should also be checked. A careful review of the ERR file and
the input file will often reveal solutions to the most common
errors. Also, see the section.
EnergyPlus uses snippets of IDF files to create the library
of data that may be useful for you. Two folders are created
upon installation: DataSets – which contains IDF snippets and
MacroDataSets – which also contain IDF snippets but are in a
form such that they can be easily used with the EPMacro
program. Another data set are DDY files that accompany each
EPW weather file. The DDY files include several varieties of
the corresponding design day data for each weather file
location.
The EnergyPlus install includes a variety of tools to help
with various aspects of converting data or displaying
information to help with using EnergyPlus
Coefficient Curve Generation - The CoeffConv and CoeffConv
utility programs can be used to convert DOE-2 temperature
dependent curves (Fahrenheit) to EnergyPlus temperature curves
(Celsius). These programs are described in the Auxiliary
Programs document.
HVAC Performance Curve Fit Tool - The CurveFitTool.xlsm
spreadsheet generates performance curves for a set of tabular
data as typically supply by manufacturers
HVAC-Diagram - Another post-processing program is the
HVAC-Diagram application. It reads one of the EnergyPlus
output files (eplusout.bnd) and produces a Scalable Vector
Graphics (SVG) file. Many web browsers and other drawing
programs can open SVG files. This utility runs automatically
with EP-Launch. More information on the HVAC Diagram program
is found in the Auxiliary Programs document.
convertESOMTR - This simple post-processing program can be
used seamlessly with EP-Launch to provide IP (inch-pound) unit
output files rather than SI units. This program is described
more fully in the Auxiliary Programs document.
WeatherConverter - Used to convert epw to csv format with
column headings to inspection of the data.
The following sections provide an overview of the input
objects based on groups described in the energy+.idd file and
the InputOutputReference. The sections give you a taste of the
capabilities and may help guide you to further investigation
on how to model your building or a specific energy efficiency
measure.
EnergyPlus includes a group of input objects used to set
general parameters related to how the simulation is performed.
Some of these input objects are controlling different options
that are allowed within EnergyPlus such as the selection of
algorithms to use or parameters related to how an algorithm is
used. For a new modeler, these input objects should be
included with their default field values. Later when
additional control is necessary to model a specific type of
measure, the field values can be re-evaluated. The following
input object allows you to control how you want the simulation
to be performed. The input objects should appear in your file
and appear in almost all of the example files:
SimulationControl - controls if the simulation is run for
the weather file period and if sizing calculations are
performed. You should become familiar with this input object
since you may find it one that you frequently change during
the Run-Check-Edit cycle.
Two other input objects should appear in your input file
and are included in almost all example files:
Version - indicates what version of EnergyPlus is being
used.
Building - includes fields for the name of the building,
and the angle of the entire building compared to true north,
as well as parameters related to the simulation that, in
general, should be allowed to default.
For a new modeler, the following input objects may be
omitted. They can be added later for special cases although
they appear in almost all of the example files:
Timestep - the number of timesteps each hour and usually
set to 6.
HeatBalanceAlgorithm - selects the algorithm used for
simulating heat and moisture transfer through the surfaces of
the building and usually set to
ConductionTransferFunction.
SurfaceConvectionAlgorithm:Inside - selects the algorithm
used for the inside face of the building surfaces and is
usually set to TARP.
SurfaceConvectionAlgorithm:Outside - selects the algorithm
used for the outside face of the building surfaces between
interior and exterior conditions and is usually set to
DOE-2.
These input objects and more are further explained in the
InputOutputReference under the heading “Group-Simulation
Parameters.”
Many of the fields in the group of input objects related to
location, climate, and the weather file are ones that will be
set once for each specific project.
Site:Location - describes the name, latitude, longitude
and other parameters related to the location of the building.
When using a weather file, the values from the weather file
will be used instead. Predefined location objects may be found
in the DDY file that accompanies most epw weather files.
SizingPeriod:DesignDay - the high and low temperature and
humidities describing a design day that is used for sizing
equipment. Two (or more) instances of this input object are
frequently in a file, one for heating and one for cooling. The
DDY file that comes with the weather file should include input
objects that may be used here.
RunPeriod - the start and stop dates of the simulation and
often set to the full year. When debugging a file, a shorter
period of time can be used to speed up the simulation portion
of the Run-Check-Edit cycle.
RunPeriodControl:SpecialDays - allows specification of
holidays and a good example can be seen in
5ZoneCostEst.idf.
RunPeriodControl:DaylightSavingTime - allows the
specification of the start and ending period for daylight
savings time. This will impact when schedules operate but
please note that output reporting timesteps are always shown
in standard time so schedules will shift an hour in the output
when daylight savings time is active. A good example can be
seen in 5ZoneCostEst.idf.
Site:GroundTemperature:BuildingSurface - for one of the
ground temperature algorithms, specifies the average
temperature for each month of the year. This temperature is
applied directly to the outside face of surfaces which use the
Ground outside boundary conditions. See Ground Heat Transfer
in EnergyPlus in the Auxiliary Programs document for
information about preprocessors. There are also other more
integrated ground heat transfer options, see
Site:GroundDomain:* and Foundation:Kiva.
Site:WaterMainsTemperature - input for the water
temperatures supplied to the building from underground water
mains and should be specified whenever water heaters are
described. A good example can be seen in
5ZoneVAV-ChilledWaterStorage-Mixed.idf. If not specified, some
default assumptions are used for the water temperature
supplied to the building.
Other input objects in this group can help perform sizing
using the weather file, override the sky temperature, impact
the variation of outdoor conditions with building height
(especially important for tall buildings), work with ground
temperatures and ground heat transfer, override the
precipitation in weather files, specify the irrigation for a
green roof, and some advanced properties related to the light
spectrum for window performance. These input objects and more
are further explained in the InputOutputReference under the
heading “Group-Location and Climate.”
Many aspects of building operation are characterized by
timing whether it is the hours that a building is occupied or
when the control systems are in various modes. Due to this,
specifying when something occurs using the Schedule input
objects becomes one of the most common things to do. It is
important to coordinate schedules properly. The operation of
office equipment in a space usually corresponds to occupancy
of that space as does the thermostat set points and fan
operation. Because schedules are such a key input for so many
features of a building, a great deal of flexibility exists in
EnergyPlus to specify them.
Schedule:Compact - The most commonly used method of
specifying schedules and uses “Through” and “For” to reduce
the amount of input required.
ScheduleTypeLimits - Every schedule input object includes
a field that helps validate the limiting values for the
schedule, and this input object describes the upper and lower
limit.
Schedule:Constant - If the value of the schedule is the
same every hour of the year, this input object is the easiest
way to specify that value.
Schedule:File - At times, data is available from a
building being monitored or for factors that change throughout
the year. This input object allows a column of data from an
external file to be referenced as the values of the schedule.
A variation of this input object allows input specifically for
shading.
Various Office Schedules
Other input objects in this input group allow specification
of schedule values to be in different formats. These input
objects and more are further explained in the
InputOutputReference under the heading “Group-Schedules.”
Specifying the physical properties of the building envelope
is something every building model includes. The input objects
in this group allow the specification of the different layers
that make up exterior and interior walls, roofs, floors,
windows, and skylights as well as the order of the materials
in these surfaces. A large number of input objects appear in
this group since there are many special features that need to
be modeled for certain energy efficiency measures. The
following is a list of only the most commonly used input
objects.
Material - the most common input object to describe the
materials used in opaque constructions in walls, roofs, and
floors and includes inputs for the thickness, conductivity,
density, and specific heat as well as absorptances. See
examples in ASHRAE_2005_HOF_Materials.idf located in the
DataSets folder.
Material:NoMass - used when the material only has thermal
resistance and little thermal mass such as insulation. It
should not be used to describe materials that do have
significant thermal mass.
Material:AirGap - used to describe when walls or roofs
have an air gap. Note, this is modeled as a fixed resistance
(with no internal convection or radiant transfer), and it
cannot be used for windows.
WindowMaterial:Glazing - describes the material used in
the glass (or other transparent material) portion of the
fenestration (windows and skylights). See
WindowGlassMaterials.idf in the DataSets folder for
examples.
WindowMaterial:Gas - the type of gas used between layers
of glass in windows and skylights has a significant impact on
the heat transfer performance. See WindowGasMaterials.idf in
the DataSets folder for examples.
Construction - a list of materials (any from the list
above plus others) in order from the outside to the inside
making up the wall, roof, floor, window or skylight. Every
input file will have several of these input objects. Examples
of constructions for walls, roofs, and floors can be found in
ASHRAE_2005_HOF_Materials.idf located in the DataSets folder
while examples for windows and skylights can be found in
WindowConstructs.idf in the same folder.
WindowMaterial:SimpleGlazingSystem - the best way to
describe a window is with a construction input object that
references WindowMaterial:Glazing and WindowMaterial:Gas input
objects but if all you have is the U-Factor and Solar Heat
Gain Coefficient (SHGC) they can be specified in this input
object.
Envelope Component Hierarchy
A large variety of input objects in this group are not as
commonly used but are key to modeling specific types of walls
and windows so if what you are trying to model does not fall
into the neat categories for the input objects described so
far, there is still a good chance that EnergyPlus has an input
object that will work. These other input objects include ones
for walls and roof that can be used when modeling combined
heat and moisture transfer, modeling materials which undergo a
phase change to store heat in the wall or when the material
properties change with temperature, when the material allows
infrared radiation to flow through it, when modeling green
(vegetated) roofs, for simplified C- or F-factor modeling, or
when the wall includes resistance or hydronic tubing to
provide heat. The other input objects to describe windows and
skylights include input objects that can be used to describe
thermochromic and electrochromic glazing, mixtures of gases
between layers of glass, vacuum glazing, movable portions of
the window assembly such as shades and blinds and screens,
alternative ways of specifying fenestration such as equivalent
layers or refraction extinction method or ASHWAT model or from
a WINDOW program export/data file or specifying
wavelength-by-wavelength properties.
The input objects described in this section are further
explained in the InputOutputReference under the heading
“Group-Surface Construction
Elements.”
The physical aspects of the building such as the walls,
roof, and windows, is one of the most important and often
challenging aspects of creating a building energy model. In
EnergyPlus, the surfaces define the geometry of each zone and
thus for the entire building. For many, a graphical user
interface will be used to help define the geometric aspects of
the building energy model, and many of the input objects
described in this section will be directly created by that
interface program. It is still important to understand some of
the details for these input objects because it is likely that
you will be reviewing them as part of debugging error
messages. EnergyPlus uses the three dimensional position of
each corner of a surface to define the position and
orientation of that surface so for a typical rectangular wall
that represents 12 numbers and for a typical building with
hundreds of surfaces that means thousands of numbers are used
to define the geometry of a building so you can see why using
an interface is so common.
EnergyPlus uses a right-hand coordinate system as shown in
Figure X with three dimensions. The X-axis points east, the
Y-axis points north, and the Z-axis points up.
EnergyPlus Coordinate System
Zone - defines the name of the thermal zone as well as the
ceiling height, floor area, and volume. For most zones that
are fully enclosed these three entries can be calculated
automatically be EnergyPlus and do not need to be entered. A
zone multiplier allows a single zone to represent many
identical zones (such as all the enclosed offices on one side
of a building). The name of the zone will be referenced in
many places in the input file so it should be clear what it is
describing. When defining a zone, it is important for the
entire area to be thermally similar both in heat being
transferred through exterior walls as well as interior heat
gains. But using as few zones as possible (and thus as few
surfaces) also can result in faster simulations, so there is
no reason to slow down the simulation just so two (or more)
essentially identical areas are each simulated. The
coordinates can be just set to zero if the world coordinate
system is used (see GlobalGeometryRules below).
BuildingSurface:Detailed - lists the three-dimensional
coordinates that define each corner as well as referencing the
zone that the surface is attached to and the construction of
the wall (list of materials). This input object supports any
shape surface with three or more corners (vertices). In
addition, this input object defines what is on the other side
of the surface from the zone, whether that is outside, another
zone in the building, or the ground. Other inputs indicate if
the outside of the surface is exposed to the sun or the
wind.
FenestrationSurface:Detailed - describes windows, doors,
and special daylighting tubes and it references the wall that
it is part of. It also requires the specification of vertices
(usually four but three is also allowed) to describe the
corners of the window or door as well as the construction
which, in this case, is generally the layers of glass and the
gas fill between the layers. It has a field for a multiplier
although usually the multiplier is set to one since the
position of windows matters to many of the algorithms used. In
order to describe the frame of the window and any dividers
that it might have, a separate input object
(WindowProperty:FrameAndDivider) may be included and
referenced. A good example file is WindowsTests.idf. To
understand how to model the many options for windows, a
section and a table in the Input Output Reference called
“Window Modeling Options” should be examined.
Casting shadows on the building, especially onto windows,
can significantly impact the energy use of a building, and
EnergyPlus includes several input objects to model this
effect. The largest impact of shading surfaces is to reduce
solar gain through windows that are shaded. There are two
kinds of shading surfaces in EnergyPlus, detached and
attached. A detached shading surface, such as a tree or
neighboring building, is not connected to the building. An
attached shading surface is typically an overhang or fin that
is attached to a particular base surface of the building,
usually a wall; attached shading surfaces are usually designed
to shade specific windows.
Shading:Site:Detailed - describes something near but not
attached to the building that casts a shadow on the building
such as nearby buildings or mountains and includes the vertex
of one corner as well as the length and width. For deciduous
trees, and other situations that shading changes over time,
the schedule for the transmittance can vary, otherwise, it
should always be set to zero or leave the schedule name
blank.
Shading:Zone:Detailed - describes an attachment to the
building that casts a shadow such as an overhang or fin. It
also includes a reference to a transmittance schedule. The
wall that the fin or overhang is attached to is also
specified.
If using relative coordinates (see GlobalGeometryRules),
you may also want to use the Shading:Building:Detailed
input object since it will “rotate” with the building.
Typically, Shading:Site:Detailed
is used for things that are fixed at the site and don’t move
with building rotation. Shading:Building:Detailed
is for larger structures like a parking garage or canopy which
aren’t associated with a specific zone but would likely rotate
with the building.
EnergyPlus includes a bunch of variations on these basic
surface input objects that map to a closer representation of
real surfaces in buildings. These input objects are
effectively just different ways to represent the same
information as the BuildingSurface:Detailed,FenestrationSurface:Detailed,
and Shading:Zone:Detailed
input objects. These input objects are seldom created by
graphical user interfaces, so it is unlikely that you will see
them. Some of these input objects also have simpler methods
for specifying geometry, such as using a single vertex,
height, width, tilt, and azimuth or just specifying the fin
location relative to the window edge. The following is a list
of these input object variations for surfaces:
GlobalGeometryRules - A required input object that should
be in all files. It sets the way geometry is specified for all
of the surface input objects. The most common approach is that
the order of coordinates for each surface should start with
the upper left corner (when viewed from “outside” the zone
with the surface) and that the coordinates should proceed in a
counter-clockwise order. In addition, most common is to use a
world coordinate system where all the vertices are based on a
single coordinate system for the entire building rather than
one that changes relative to each zone. However, if you want
to rotate the building, then you must specify Relative
coordinates, and the zone origins may all remain at
(0,0,0).
WindowShadingControl - for a window, describes the kind of
movable shading (interior shade, interior blind, between glass
shade, exterior blind, etc..) as well as how it is controlled
and the physical material of the shade or window construction
with the shade. Good examples are in the
PurchAirWithDaylightingAndShadeControl.idf file.
WindowProperty:FrameAndDivider - defines the frame
material around a window and any dividers between separate
lites of the window (see Figure X). While a window does not
necessarily need to define the frame, it is a more accurate
approach since the heat transfer through the frame usually has
significant impacts the overall performance of a window. Note
that the area of the Fenestration:Detailed object is the
glazed area without the frame. The frame extends beyond the
glazed area. See the PurchAirWithDaylighting.idf example
file.
A window with frame and divider
WindowProperty:AirflowControl - defines windows that have
forced air flow between the panes of glass, also called
heat-extract windows or climate windows. See the example file
AirflowWindowsAndBetweenGlassBlinds.idf.
WindowProperty:StormWindow - allows the definition of a
movable storm window that is usually applied to a window in
the winter. See the StormWindow.idf example file.
InternalMass - used to define thermal mass that is not
described anywhere else in the model - often used to capture
the effect of furnishings or interior floors that are not
being modeled. Used in many example files including
RefBldgLargeOfficeNew2004_Chicago.idf.
ShadingProperty:Reflectance - specifying the reflectance
properties for shading and is only needed if the input object
Building specifies the “with reflections” option. See the
ReflectiveAdjacentBuilding.idf example file.
Other less common input objects include ZoneList
and ZoneGroup
that can be used when doing multi-story simulations and GeometryTransform
which allows a building model to be stretched with just a few
inputs.
Inside a building, people, appliances, office equipment,
lighting, and other devices produce heat. The combination of
all these items that produce heat within a building are called
internal gains and represents a significant contribution,
sometimes the largest contribution, to the cooling
requirements for a building. In addition, they offset the
amount of heat from the HVAC system that is needed at a given
time. Typically, the peak value is entered in the input
objects for this group such as the maximum number of people,
the total power of equipment, or the total lighting power and
then a schedule is used to modify that value each hour of the
year. It is just as critical that the schedule values are
realistic for your building as is the peak value. For almost
all buildings, it is rare that the peak occupancy occurs for
more than a few hours per year if at all and this is
especially the case for retail stores, theaters, and sports
complexes. Even office buildings when counting vacations and
people out of the building for meetings will rarely have peak
occupancy.
The most common internal gain input objects that are shown
in almost all the example files are:
People – specifies not only the sensible, latent and
radiant heat from people but also includes ways of reporting
the comfort of occupants using a variety of thermal comfort
models. The DynamicClothing.idf example file shows how to use
the thermal comfort models.
Lights – describes the heat related to lighting
systems.
ElectricEquipment – describes the heat related to
electrical appliances, office equipment, and other heat
sources that are powered by electricity.
GasEquipment - specifies the heat related to cooking
appliances and other equipment that uses natural gas.
Less common internal gains input objects include:
OtherEquipment - describes any heat gain or loss
(sensible, radiant, and/or latent) that impacts the space but
does not consume utility energy in the simulation. Typically
used to model a process load which is not to be included in
the overall building energy consumption.
ElectricEquipment:ITE:AirCooled - see the
1ZoneDataCenterCRAC_wApproachTemp.idf example file.
SwimmingPool:Indoor - see the 5ZoneSwimmingPool.idf
example file.
Other
ComfortViewFactorAngles – allows the specification of how
different surfaces impact the thermal comfort calculations for
the occupants. See the PurchAirWithDaylightingAngleFac.idf
example file.
The Internal Gains group also contains input objects
related to zone contaminant sources and sinks. The input
objects include modeling components that impact contaminant
concentrations which are scheduled, pressure driven, use a cut
off model, assume a decaying source, surface diffusion, or
using a deposition velocity model. The input objects described
in this section are further explained in the
InputOutputReference under the heading “Group-Internal
Gains.”
Reducing the amount of powered lighting that is used when
sufficient natural daylight illuminates the interior building
through windows and skylights is called daylighting.
Automatics daylighting control systems are a very common
energy efficiency measure in buildings and are often required
for new building designs depending on the energy code that
applies to the building location. The most common input
objects related to daylighting are:
Daylighting:Controls – specifies the algorithm used for
daylighting, the dimming of lights is continuous or stepped,
and how glare calculations are performed.
Daylighting:ReferencePoint – specifies the location of the
sensors for the daylighting control system.
The InputOutputReference includes not only a description of
these input objects but also extra guidance on how they should
be applied. The PurchAirWithDaylighting.idf contains examples
of these input objects.
Daylighting with Continuous Dimming
Three different devices can be used with daylighting:
DaylightingDevice:Tubular - see the
DaylightingDeviceTubular.idf example file.
DaylightingDevice:Shelf - see the
DaylightingDeviceShelf.idf example file.
DaylightingDevice:LightWell - see the GeometryTest.idf
example file.
An input object called Daylighting:DELight:ComplexFenestration
is used with one of the two control methods specified in the
Daylighting:Controls
input object when used in conjunction with complex
fenestration systems such as prismatic and holographic
glass.
Some flexibility is given to provide extra output related
to daylighting and includes:
Output:DaylightFactors – creates a special report on the
factors used in daylighting. See the ReportDaylightFactors.idf
example file.
Output:IlluminanceMap – allows the generation of maps of
illuminance values within each interior zone that uses
daylighting controls. The exact file format can be set using
the OutputControl:IlluminanceMap:Style input object. See the
DaylightingDeviceTubular.idf for example of both input
objects.
More details of these output options can be found in the
OutputDetailsAndExamples document. The input objects described
in this section are further explained in the
InputOutputReference under the heading
“Group-Daylighting.”
Advanced
Construction, Surface, Zone Concepts[LINK]
The group of input objects contains many special cases for
more sophisticated modeling for constructions, surfaces, and
zones. As part of this, one of the ways to model building
foundations called Kiva is described. See the
ZoneCoupledKivaBasement.idf and ZoneCoupledKivaSlab.idf
example files for example of these input objects.
Foundation:Kiva - describes the insulation depth and width
for interior and exterior horizontal and vertical insulated
foundations as well as the construction for the wall footing,
see Figure X .
Foundation:Kiva:Settings - sets the soil conditions and
other parameters related to the Foundation:Kiva input
object.
SurfaceProperty:ExposedFoundationPerimeter - used to set
the portion of the foundation that is along the exterior
perimeter of the building that undergoes heat transfer with
the environment. Edges of underground surfaces that are fully
under the building and not along the perimeter are not
expected to have any heat transfer with the environment.
Structural and insulation components of Foundation:Kiva input
objects
Input objects of interest in this group not related to Kiva
include
SurfaceControl:MovableInsulation - allows the modeling of
insulation panels that are removable for walls, floors, and
roofs but not windows. See MovableExtInsulationSimple.idf and
MovableIntInsulationLightsLowE.idf example files.
SurfaceProperty:Underwater - allows the outside of the
building to be modeled as underwater and even as moving
through the water allowing EnergyPlus to model vessels. See
the VaryingLocationAndOrientation.idf example file.
SurfaceProperty:ExteriorNaturalVentedCavity - provides a
method to include the modeling of baffles in the multi-skin
exteriors. See the HP_wICSSolarCollector.idf example
file.
Other input objects in this group set the heat transfer
algorithms for specific surfaces to override the building
level heat transfer algorithm, when other models are used to
describe the variation in temperature on the outside of a
surface, override the algorithm used for modeling convection
heat transfer between the air inside or outside of a zone and
the surface, vapor transfer coefficients when using algorithms
that include moisture modeling of surfaces, override the
algorithm that distributes the solar radiation on interior
surfaces, overrides the solar energy absorbed by different
layers for complex windows, a way to override the longwave
radiation with other surfaces in the zone, allows overriding
the external environment for a surface or a zone including
solar shading or airspeed or temperature or humidity,
overrides the source term for the heat balance, or overrides
the view factors for a zone. The input objects described in
this section are further explained in the InputOutputReference
under the heading “Group-Advanced Surface Concepts.”
While equipment that is outside of a building does not
impact the thermal performance of the building, the accounting
of all end-uses including those outside of the building is
important for many compliance and incentive programs that
require building energy modeling. See the
ExteriorLightsAndEq.idf example file for these input
objects.
Exterior:Lights - describes the external site lighting for
the building grounds, entrances, and facades which are either
controlled by a schedule or when the sun is set.
Exterior:FuelEquipment - describes other energy
consumption on the site that is external to the building other
than lighting.
Exterior:WaterEquipment - describes the flow rate of water
use on the building site outside of the building.
The input objects described in this section are further
explained in the InputOutputReference under the heading
“Group-Exterior Energy Use Equipment.”
The Zone
Airflow input object group provides a way to model the airflow
between zones and airflow due to natural ventilation (e.g.,
open windows) or mechanically-induced ventilation (e.g.,
exhaust air fans).
ZoneInfiltration:DesignFlowRate - provides a way to
describe the air infiltration into a building through leaks in
the envelope including around windows or the normal operation
of doors. The leakage can be a function of temperature and
wind speed and can be expressed as either a total flow rate, a
flow rate per floor area, per wall area, or as an air change
rate. This input object appears in most example files.
ZoneInfiltration:EffectiveLeakageArea - similar to the
previous input object but uses a different equation to express
the infiltration rate. The DirectIndirectEvapCoolers.idf file
contains an example.
ZoneInfiltration:FlowCoefficient - also similar to the
ZoneInfiltration:DesignFlowRate input object but uses yet a
different equation.The DirectIndirectEvapCoolers.idf file
contains an example.
ZoneVentilation:DesignFlowRate - a method to add outside
air to a zone with similar inputs to the
ZoneInfiltration:DesignFlowRate but this would represent a
purposeful introduction of outdoor air into the space. See the
5ZoneNightVent2.idf example file.
ZoneVentilation:WindandStackOpenArea - describes the
natural ventilation driven introduction of outdoor air into
the zone using a simpler method than an AirflowNetwork model.
The inputs include the opening area and effectiveness as well
as simple controls based on zone or outdoor temperature or the
difference between the two or wind speed. See the
VentilationSimpleTest.idf file.
ZoneMixing, ZoneCrossMixing, and
ZoneRefrigerationDoorMixing - these three input objects
provide simplified treatments of air exchange between
zones.
ZoneEarthtube - provides a way to model an earth tube
which is a way to draw outdoor into the zone through an
underground pipe in order to cool the air in the summer and
heat it in the winter. An example of this input object is in
the EarthTubeSimpleTest.idf file.
ZoneCoolTower:Shower - models a passive downdraught
evaporative cooling tower (sometimes also called a shower
cooling tower or a wind tower) using natural ventilation and
water evaporation to providing cooling in typically arid
climates. See the CooltowerSimpleTestwithVentilation.idf for
an example of this input object.
ZoneThermalChimney - models a passive solar driven thermal
chimney that utilize the buoyancy of air heated by the sun to
provide ventilation. See the file ThermalChimneyTest.idf.
ZoneAirBalance:OutdoorAir - calculates the combined
outdoor airflow including the interactions between mechanical
ventilation, infiltration, and duct leakage and is usually
applied to residential buildings. See the
SingleFamilyHouse_TwoSpeed_ZoneAirBalance.idf file for
example.
The input objects described in this section are further
explained in the InputOutputReference under the heading
“Group-Airflow.”
New users to EnergyPlus need to learn many things to
understand how to create detailed input objects for modeling
an HVAC system. In order to reduce this initial effort,
HVACTemplates were created. Unlike other input objects, the
HVACTemplate input objects are not directly processed by
EnergyPlus; instead, a preprocessor called ExpandObjects turns
these HVACTemplate input objects into the detailed HVAC input
objects. This can be used as a learning tool since you can
review the .expidf file that contains the detailed input
objects or it can be used for long term modeling especially if
your focus is not on HVAC related energy efficiency measures.
The primary disadvantage of using the HVACTemplate input
objects is that only a small subset of possible configurations
can be modeled using them; however, the subset of
configurations supported by the HVACTemplate input objects was
carefully chosen to be some of the most common HVAC
configurations. If the HVACTemplate input objects do not
support the HVAC configuration you are considering; you need
to model it with the detailed HVAC EnergyPlus input objects.
When using HVACTemplate input objects, no regular EnergyPlus
input objects related to HVAC should be used (see the
InputOutputReference for some exceptions to this). The
HVACTemplates can model:
Baseboard heating systems with optional hot water
boiler
Fan coil systems with boilers and chillers
Packaged terminal air conditioner (PTAC) system with
optional hot water boiler
Packaged terminal air-to-air heat pump (PTHP) systems
Water to air heat pumps with boiler and cooling tower
Variable refrigerant flow heat pumps (air-to-air)
Variable refrigerant flow heat pumps (water-to-air) with
boiler and cooling tower
Direct-expansion (DX) cooling, package and split
systems
Direct-expansion (DX) heat pump systems
Packaged variable air volume system using direct-expansion
cooling
Variable air volume systems with boilers and air-cooled
chillers
Variable air volume systems with boilers and water-cooled
chillers
Constant air volume systems with boilers and water-cooled
chillers
Dual-duct systems (constant or variable air volume) with
boilers and water-cooled chillers
Dedicated outdoor air systems (DOAS) combined with zonal
template systems
The Input Output Reference includes a list of exactly which
input objects are needed for each of these configurations
HVACTemplate:Thermostat - describes the heating and
cooling setpoints for a thermostat. This input object can be
referenced by multiple HVACTemplate:Zone input objects if all
the zones have the same setpoints.
HVACTemplate:Zone:IdealLoadsAirSystem - provides an
idealized system that supplies air to the zone that meets all
loads and uses no energy. Best used for load
calculations.
HVACTemplate:Zone:BaseboardHeat - allows the simulation of
electric or hot water thermostatically controlled baseboard
heaters.
HVACTemplate:Zone:FanCoil - describes a four-pipe fan coil
system with outdoor air intake.
HVACTemplate:Zone:PTAC - models a packaged terminal air
conditioner with either electric, gas or hot water heating
coil most commonly used in residential or hotel
applications.
HVACTemplate:Zone:PTHP - models a packaged terminal heat
pump system most commonly used in residential or hotel
applications with either electric or gas supplementary
heater.
HVACTemplate:Zone:WaterToAirHeatPump - describes the
distributed “terminal” portions of a system which uses a
medium temperature loop and heat pumps to provide heating and
cooling to the building (also see
HVACTemplate:Plant:MixedWaterLoop).
HVACTemplate:Zone:VRF - provides input for variable
refrigerant flow terminal units.
HVACTemplate:Zone:Unitary - describes a constant volume
direct-expansion system such as a rooftop system or split
system. Often paired with a single HVACTemplate:System:Unitary
for a single zone system but can also be part of a multizone
system.
HVACTemplate:Zone:VAV - simulates the terminal of a
variable air volume system with reheat.
HVACTemplate:Zone:VAV:FanPowered - simulates either a
parallel or series fan power terminal of a variable air volume
system.
HVACTemplate:Zone:VAV:HeatAndCool - simulates the terminal
of a variable air volume system.
HVACTemplate:Zone:ConstantVolume - simulates the terminal
of a constant air volume system.
HVACTemplate:Zone:DualDuct - simulates the zone portion of
a constant volume or variable volume dual-duct HVAC
system.
HVACTemplate:System:VRF - simulates the variable
refrigerant flow system.
HVACTemplate:System:Unitary - describes the system portion
of a rooftop or split DX cooling system with electric, gas or
hot water heating.
HVACTemplate:System:UnitaryHeatPump:AirToAir - details the
system portion of a rooftop or split DX air-to-air heat pump
system.
HVACTemplate:System:UnitarySystem - models the system
portion of a rooftop or split system and has more flexibility
than the previous two input objects.
HVACTemplate:System:VAV - simulates the system portion of
a variable air volume HVAC configuration with chilled water
cooling and several different heating options.
HVACTemplate:System:PackagedVAV - describes the system
portion of a packaged direct-expansion (DX) based variable air
volume HVAC configuration with several different heating
options.
HVACTemplate:System:ConstantVolume - provides input for
the system portion of a constant air volume HVAC configuration
with optional chilled water cooling and several different
heating options.
HVACTemplate:System:DualDuct - models the system portion
of a constant air volume or variable air volume dual-duct HVAC
configuration with optional chilled water cooling and several
different heating options.
HVACTemplate:System:DedicatedOutdoorAir - adds a dedicated
outdoor air system (DOAS) which can be used with several of
the HVACTemplate:Zone input objects and contains heating and
cooling coils and heat recovery.
HVACTemplate:Plant:ChilledWaterLoop - models the chilled
water loop connecting chillers to chilled water coils as well
as the condenser water loop that connects chillers with
cooling towers.
HVACTemplate:Plant:Chiller - describes a vapor-compression
chiller that provides chilled water to the loop.
HVACTemplate:Plant:Tower - models an evaporative cooling
tower used to reject heat from chillers.
HVACTemplate:Plant:HotWaterLoop - models the hot water
loop connecting boilers to hot water coils.
HVACTemplate:Plant:Boiler - models a boiler that provides
hot water to the loop.
HVACTemplate:Plant:MixedWaterLoop - models the medium
temperature loop that serves water-to-air heat pumps as well
as cooling towers and boilers.
In addition, this group of input objects includes three
plant input objects that allow the referencing of chillers,
towers, and boilers respectively so that additional details
can be described in those input objects. Example for these are
in the ExampleFiles directory and start with the name
HVACTempate. All of these are described in the “Input/Output
Reference” document under the Group “HVACTemplates” and please
note that this group is described in Chapter 2 while most of
the other groups of input objects are described in Chapter 1.
The expansion process is described in the Auxiliary Programs
document under “ExpandObjects.”
In buildings, HVAC systems are comprised of components such
as fans, pumps, coils, chillers and boilers connected by ducts
or pipes and controlled by systems using sensors strategically
located in the distribution systems and in the zones. In many
respects, EnergyPlus mirrors this topology by having a large
number of components and a means to describe their connections
with one another and their control systems. Every component in
an HVAC system must have an inlet and outlet “node.” In the
actual system, a node might be a point in the system at which
fluid properties can be measured. In an EnergyPlus simulation,
the nodes are points at which fluid properties are evaluated
and passed on to subsequent equipment. Components are linked
together to form various loops within the simulation. Thus,
the output node from one component also serves as the inlet
node to the next component. Loops are constructed combining
the components as well as input objects the describe the
arrangement of the components. The figure below shows a
generic example of the loop-node concept. Loop nodes are a key
defining feature in EnergyPlus. As a result, it is recommended
that one of the first steps taken in defining an HVAC system
in EnergyPlus be the definition of a node diagram or map. This
is helpful for visualization of the entire system.
Example Node Diagram
So that these loops are manageable and more clearly defined
both in the input and in the simulation, four different loop
sections can be defined in an EnergyPlus input file. In
general, these four types are in essence two pairs of loop
sections that make up two distinct types of loops: a zone/air
loop and a plant loop.
Air Loop Supply Side: The air loop is defined by the
section of the zone/air loop that starts after the zone return
streams are combined and continues on until just before any
air stream(s) are branched off to individual zones. The
starting point of the air loop is fairly straightforward. The
ending point is slightly more complex but can be understood
with some examples. For instance, in a terminal reheat system,
the end of the air loop would typically be considered the node
following the cooling coil. In a dual duct system, the air
loop would have two ending points that would correspond to the
nodes after the cooling coil and after the heating
coil/humidifier. In most cases, the air loop has a single
starting point and up to two ending points (for a two-deck
system). An outdoor air subsystem can be included in the
supply side for ventilation and relief air.
Air Loop Zone Equipment: The zone equipment section of the
input file is defined as more or less the rest of the zone/air
loop (outside air is handled separately as a subset of the air
loop). This includes everything from where the ducts are split
to serve various zones up through where the return ducts from
various zones are mixed into a single return duct. Zone
equipment can include dampers and reheat coils as well as
zone-specific conditioning systems such as thermostatic
baseboard or a window air conditioner. Most control issues are
typically dealt with in the zone equipment section of the
simulation.
Plant Loop Demand Side: One side of the plant is where
energy is “demanded” by various components that make up the
air loop or zone equipment. Typically, this is the water side
of equipment such as coils, baseboard, radiant heating and
cooling, etc. In the case of a condenser loop, energy is
typically “demanded” by a chiller condenser or other water
source heat pump. The demand side of this loop can also
include a splitter, a mixer, and a bypass.
Plant Loop Supply Side: The other side of the plant loop
is where energy is “supplied” by various components. The
components typically found on the supply side include pumps,
boilers, chillers, purchased heating and cooling, ice storage,
etc. In the case of a condenser, the components would be a
cooling tower, fluid cooler, or ground source heat exchanger,
etc. As with the demand side, this loop can also include a
splitter, a mixer, and a bypass.
Detailed HVAC Heat Loop Line Diagram
The following is a list of groups of input objects related
to specifying detailed HVAC systems in EnergyPlus related to
zone equipment and secondary systems:
HVAC Design Objects - describes input objects related to
how EnergyPlus performs autosizing for air terminals, zone
equipment, systems, and plant components as well as for
outdoor air systems.
Node-Branch Management - used to describe some of the
topological features of EnergyPlus such as nodes, pipes, and
ducts as well as branches (pieces of loops) and
connectors.
Air Distribution - describes the arrangement of the
components in an air distribution system includes the outdoor
air system, splitters, mixers, and plenums.
Zone HVAC Controls and Thermostats - input objects related
to thermostats and humidistats used to control the conditions
in a zone.
Zone HVAC Forced Air Units - defines input related to zone
forced air equipment like window air conditioners, packaged
terminal air conditions (PTAC), unit heaters, fan coil
systems, and outdoor air units as well as other related input
objects.
Zone HVAC Radiative/Convective Units - models baseboard
systems, low- and high-temperature radiant systems, and active
portion of ventilated slabs.
Zone HVAC Air Loop Terminal Units - describes air
terminals including constant volume, variable volume, series
and parallel powered induction units, and duel duct
terminals.
Zone HVAC Equipment Connections - used to describe the
HVAC equipment connections at the zone level.
Fans - describes constant volume, variable volume, exhaust
fans as well as more system and component model fans.
Coils - contains a long list of input objects to model
heating and cooling water coils; heating and cooling DX coils
including two-, multiple-, and variable-speed units; variable
refrigerant coils; fuel and gas coils; desuperheater coils;
air to water heat pump coils; and other coil input
objects.
Evaporative Coolers - describes direct and indirect
evaporative coolers.
Humidifiers and Dehumidifiers - for electric and gas steam
humidifiers as well as desiccant dehumidifiers.
Heat Recovery - models for air-to-air flat plate and
combined sensible and latent heat exchangers as well as heat
exchangers coupled with desiccants.
Unitary Equipment - describes unitary input objects that
are generally placed in the primary air loop and includes
heating only, heating and cooling, and air-to-air heat pump
input objects.
Variable Refrigerant Flow Equipment - input objects to
describe variable refrigerant flow (VRF) equipment as well as
the controls.
The following is a list of control systems in EnergyPlus
related to HVAC
Controllers - input objects for simple controllers that
look at a single node and compare it with the setpoint and
includes controllers for water coils, outdoor air, and
mechanical ventilation.
System Availability Managers - these input objects can
take an input from any node and control whether an entire
portion of the HVAC system is active and can be based on
temperature, differential temperature, schedules, night cycle,
and ventilation.
Setpoint Managers - these take input from any node or
nodes and calculate a setpoint at another node and include
controls for single zone heating, cooling, or reheat; humidity
control; mixed air; warmest or coldest; and many other
scenarios.
Plant-Condenser Control - provides control for the plant
loop primarily controlling the operation of the loop and which
equipment is available and includes control based on heating
or cooling load and in reference to outdoor conditions such as
dry-bulb or wet-bulb temperature.
Plant-Condenser Flow Control - describes the
TemperingValve input object for the special case of flow
control with thermal storage systems.
The following is a list of input objects related to primary
systems and equipment:
Pumps - describes constant speed and variable speed pumps
and headered multiple pump systems.
Plant-Condenser Loops - describes the supply and demand
side of the loops the operating temperatures and flow
rates.
Plant Heating and Cooling Equipment - used to input the
central plant equipment such as steam and hot water boilers;
electric, absorption, engine driven, and turbine chillers; and
water-to-water heat pumps; as well as connections to district
heating and cooling sources.
Condenser Equipment and Heat Exchangers - describes
single-, two, and variable speed cooling towers; single and
two speed evaporative and non-evaporative fluid coolers;
vertical, surface, trench and slinky ground heat exchangers;
and fluid-to-fluid heat exchangers.
Non-Zone Equipment - describes the LoadProfile:Plant input
object that allows the load on the plant to be specified by
schedule if already known.
User Defined HVAC and Plant Component Models - a group
that allows the user to define custom models for zonal
systems, air terminals, coils, and plant equipment.
The input object groups described in this section are
further explained in the InputOutputReference.
The primary goal of modeling is seeing the results of the
model contained in the output reporting. EnergyPlus has
several different types of outputs, but initially the most
important to understand are the tabular output reports that
summarize the results of the simulation. The Output:Table:SummaryReports
and OutputControl:Table:Style
input objects described below are the only two necessary to
start generating the tabular output reports:
Output:Table:SummaryReports - allows the specification of
different tabular reports but usually just specifying
AllSummary is necessary. Additional reports can be shown by
specifying AllSummaryAndMonthly,
AllSummaryMonthlyAndSizingPeriod.
OutputControl:Table:Style - specifying the output format
for the tabular reports which is most commonly HTML but a
comma, tab, fixed width, and XML options are also available.
Depending on what is specified the output reports can have
different file extensions and the file name usually has the
word “Table” or “tbl” in it.
You can also create your own custom tabular reports by
using one of the following input objects:
Output:Table:TimeBins - shows the amount of time in hours
that occurs in different bins for the single specific output
variable or meter specified
Output:Table:Monthly - shows a series of output variables
or output meters on a monthly basis using different
aggregation schemes. For output variables that reoccur for
each zone or other input objects, the monthly report will be
repeated for each one.
Output:Table:Annual - shows a series of output variables
or output meters on an annual basis using different
aggregation schemes. For output variables that reoccur for
each zone or other input objects, additional rows of results
will be displayed.
Output:VariableDictionary - provides a list of available
output variables for use with these custom tabular reports as
well as the time step reporting described next. The list of
output variables that are available for specific simulation
appear in a file with a .rdd extension, and the output meters
appear in a file with a .mdd extension.
When you need to dive deeper into the results for a
specific output variable or output meters, time step outputs
allow you to see the values of an output variable for each
timestep or other time periods. By looking at multiple output
variables and seeing how they change together over time, a
deeper understanding of the system and control operation can
be gained.
Output:Variable - these input objects are added one for
each output variable desired. Usually, an asterisk is used for
the “key value” field so that all instances of the output
variable are included. The output shows up in the .eso file
which is generally converted to a .csv file for use with a
spreadsheet.
Output:Meter and Output:Meter:MeterFileOnly - these input
objects specify the output meters (think of them as very
detailed submeters). The output from these input objects show
up in the .mtr file which is generally converted to a
Meter.csv file for use with a spreadsheet. Also, note that the
.mtd file shows the exact relationship between specific
end-use output report variables and each output meter.
Output:SQLite - use this input object if you want to
output in the SQLite database format. Not only can the output
variables and meters be in SQLite format but the tabular
reports are also included.
EnergyPlus also includes a number of special reports that
usually appear in different output files or in the .eio output
file
Output:Surfaces:List - provides a report on all the
surfaces in a file and the output appears in the .eio and .sln
output files.
Output:Surfaces:Drawing - provides a DXF drawing that can
be opened in some CAD programs .
OutputControl:SurfaceColorScheme - controls the colors
used in the DXF file.
Output:Schedules - provides a summary of the schedules in
the input file and appears as part of the file with the .eio
extension.
Output:Constructions - provides a summary of constructions
in the input file and appears as part of the file with the
.eio extension.
Output:EnergyManagementSystem - creates a list of detailed
output related to the energy management system in a file with
the .edd extension.
OutputControl:ReportingTolerances - provides more control
over the amount of time reported for the setpoints not being
met.
Output:Diagnostics - provides additional detail in the
output messages in the .err file . Normally this extra detail
is not shown to reduce confusion for new users.
Output:DebuggingData - provides an additional detailed
output related to HVAC nodes in a file with a .dbg
extension.
Environmental reporting adds new meters showing the
emissions related to the building and is triggered by the use
of the following three input objects. See the 5ZoneTDV.idf
file for examples.
Output:EnvironmentalImpactFactors - specifies the
frequency of the output variables related to emissions.
EnvironmentalImpactFactors - specifies the efficiency of
district heating and cooling systems as well as the carbon
equivalent emission factors for N20, CH4, and CO2.
FuelFactors - for each type of energy resource
(electricity, natural gas, etc..) provides a way to enter
factors related to source energy and emissions of CO2, CO,
CH4, NOx, N20, SO2, PM, NH3, NMVOC, Hg, Pb, and other
factors.
Other input objects in this group allow the accumulation of
metered results, the combination of output variables or meters
to create custom meters, and a method for preprocessors to
include error messages in the normal error file. Many example
files contain some of these input objects. All of these are
described in the “Input/Output Reference” but note that this
group is described in Chapter 5 “Input for Output” and Chapter
7 “Standard Output Reports” while most of the other groups of
input objects are described in Chapter 1. The
OutputDetailsAndExamples documentation provides even more
details on the outputs created by each of these input objects.
Several other output related input objects appear in other
areas such as Output:DaylightFactors
input object in the Daylighting group.
EnergyPlus contains several input objects that allow
economic analysis to be performed. When these input objects
are included in the input file, new tabular output reports are
automatically generated. The input objects used by EnergyPlus
for cost estimating calculations are as follows:
ComponentCost:LineItem - provides inputs related to
determining the construction cost and can be associated with
several different input objects and the cost estimate is based
on factors such as cost per area or cost per unit of output
capacity. It has not been applied to all types of input
objects so for many scenarios; construction costing would need
to be performed outside of EnergyPlus.
ComponentCost:Adjustments - allows the specification of
adjustments including miscellaneous costs per conditioned
area, design and engineering fees, contractor fees,
contingency, permitting, bonding, and insurance as well as
commissioning and regional adjustment fees.
ComponentCost:Reference - entry of reference building
costs so that the current model can be compared to the
reference building.
For many building projects, while energy estimates are
important, the computation of estimated utility bills provides
an understanding of how much money is going to be saved to
help offset possibly higher initial costs of a
high-performance building. Due to the many different utility
companies and regulatory agencies, the approach used to
compute monthly utility bills has become widely varied and, at
times, quite complicated depending not only on energy and
demand but the timing of each and the relationship between the
two. Overall, the goals of the UtilityCost input objects of
EnergyPlus are to make simple tariffs easy to model and
complex tariffs possible to model. The
5ZoneEconomicsTariffAndLifeCycleCosts.idf example file
provides several different example tariffs. The input objects
used by EnergyPlus for the calculation of monthly and annual
utility bills are as follows:
UtilityCost:Tariff - sets the parameters for the overall
tariff such as associated output meter, conversion factors,
demand computation, monthly charges, and minimum charges, and
schedule names for the time of use periods, seasons, billing
cycle, and real-time pricing.
UtilityCost:Qualify - provides a method to qualify if a
tariff applies to the building being modeled since utilities
provide limits usually based on peak demand or energy
consumption for each tariff.
UtilityCost:Charge:Simple - defines cost per unit value
for a charge based on energy or demand or other charges for a
specific season. The charges are arranged in a hierarchy shown
in Figure X Hierarchy of Economic Charges.
UtilityCost:Charge:Block - defines a more complicated but
common type of charge for energy or demand where the costs are
defined in the tariff with blocks of charges (i.e., the first
1000 kWh is one cost per kWh, the next 5000 kWh is a second
cost, and remaining kWh is a third cost). Like
UtilityCost:Charge:Simple, the charges use the same
hierarchy.
UtilityCost:Ratchet - some utilities charge not only for
the current month’s demand but also compensate for the highest
demand in recent months, and this input object allows the
specification of such a structure.
Hierarchy of Economic Charges
The following two input objects are uncommon to use:
UtilityCost:Variable - allows the specific specification
of a monthly variable to be used in the calculation of the
tariff.
UtilityCost:Computation - provides the step-by-step
specification of the steps needed to compute the tariff. The
output report tariff summary includes the default computation
steps for the input objects specified.
Life-cycle costing allows the combination of initial and
future costs (typically energy bills) to be understood using a
single metric so that multiple building energy models can be
compared even if they all have different initial and future
costs. The input objects used for performing a life-cycle cost
analysis are:
LifeCycleCost:Parameters - describes the discount, tax,
and inflation rates, the approach used for inflation and
discounting, as well as the base date and length of the study
period and other parameters related to life-cycle
costing.
LifeCycleCost:RecurringCosts - used to enter reoccurring
costs other than costs related to energy and water usage since
those are included automatically.
LifeCycleCost:NonrecurringCost - used to enter costs that
occur only once during the study period.
LifeCycleCost:UsePriceEscalation - specifies the annual
escalation of energy costs in future years and is generally
based on government predictions. The increases in energy costs
for future years are assuming they change differently than
inflation. A file that is updated each year begins with the
name LCCusePriceEscalationDataSet is included in the DataSets
directory and is based on supplements to the NIST 135
handbook.
Two less commonly used input objects are
LifeCycleCost:UseAdjustment - allows manual adjustment of
energy or water costs in future years.
CurrencyType - specifies the currency symbol of the
monetary unit. If it is not included a dollar sign ‘$’ is used
in all reports.
All of these are described in the “Input/Output Reference”
but note that this group is described in Chapter 3 “EnergyPlus
Economics” while most of the other groups of input objects are
described in Chapter 1. The OutputDetailsAndExamples
documentation provides even more details on the tabular
outputs created in the section labeled
“eplustbl.<ext>”.
The previous sections describe major groups of input
objects. This section briefly covers some of the remaining
input object groups.
Detailed Ground Heat Transfer - provides an alternative
way of describing ground heat transfer through basement walls
and floors and slabs using input objects that are then
processed by the SLAB and BASEMENT programs and is also
documented in AuxiliaryPrograms.
Energy Management System (EMS) - a high-level control
method that connects sensors and actuators with a simple
control programming language and is also documented in the
EMSApplicationGuide.
External Interface - allows the connection of EnergyPlus
using co-simulation by the import of Functional Mockup Units
(FMUs) and is also documented in the
ExternalInterfacesApplicationGuide.
Operational Faults - provides for the modeling of
operation problems in sensors, controllers, meters, equipment,
and systems and is commonly used with existing buildings.
General Data Entry - contains the Matrix:TwoDimension
input object used with the
Construction:ComplexFenestrationState input object.
Performance Curves - allows the specification of
polynomial curves used to characterize the performance of HVAC
equipment.
Performance Tables - allows the specification of tables
used to characterize the performance of HVAC equipment.
Fluid Properties - describes the detailed properties of
refrigerants and glycols.
Demand Limiting Controls - provides a way of implementing
management of the systems of the building to regulate the peak
demand.
Natural Ventilation and Duct Leakage - provides a way to
model multizone airflows driven by wind and forced air systems
(shown under Group-Airflow Network in the
InputOutputReference).
Room Air Models - allows the description of non-uniform
room air temperatures (not fully mixed).
Compliance Objects - provides an input object that allows
rotation of the building when used for compliance
purposes.
Parametrics - allows for simple parametric cases to be
defined within an input file using input objects. Makes use of
the ParametricPreprocessor as described in the
AuxiliaryPrograms document.
Refrigeration - describes supermarket and warehouse
refrigeration systems.
Electric Load Center-Generator Specifications - allows the
specification of fuel and photovoltaic generators and controls
on when they should be used to provide power to the
facility.
Water Systems - contains input objects to describe the use
of water in the building including from wells, rain, and
storage.
Solar Collectors - describes various systems that convert
solar energy into thermal energy including those that are
integrated with photovoltaic systems.
Water Heaters and Thermal Storage - describes systems that
provide water heating and storage as well as ice and chilled
water storage.
EnergyPlus Essentials[LINK]
Introduction[LINK]
The following background on building energy modeling (BEM) will provide a foundation before learning the essentials of EnergyPlus. If you are already familiar with BEM, you may wish to skip to Section 1.4 describing the EnergyPlus QuickStart Guide.
What is BEM?[LINK]
According to the BEM Library:
Some other terms that are used to describe the same topic are:
Somewhat confusing, the term “model” can refer to both the specific building being described and analyzed as well as referencing the software for implementing a specific component of the building such as a wall or chiller.
To learn more about building energy modeling consider reviewing the following resources:
Building energy modeling is necessary to understand the overall energy consumption in buildings, because, the energy flows in buildings can be very complicated. The heat flow through walls is determined not just by the area and the temperatures, but the mass characteristics of the walls may result in heat flowing out of a wall several hours after it has flowed in. The constantly changing temperature on the outside of the wall and the less frequent but often large step changes in thermostat setpoints between day and night operation for the inside of the building make the direction of the heat flow vary over time. Solar energy is absorbed on the exterior wall and roof surfaces as well as entering windows. The intensity of solar energy varies by the sun position for each period of time over the day and over the year. Heat sources within the building including people, office and other equipment, and lighting include both heat that immediately impacts the air within (convective heat) and heat that is absorbed by the surfaces and released slowly over time (radiant heat). Lighting may be controlled by a sensor that turns it on or off or changes its intensity based on the amount of natural daylight that is entering the space through windows and skylights making the heat generated from the lighting system change over time. Air conditioning and heating systems come in a huge number of configurations, and each one can be used with many different control configurations based on the temperature or other conditions within each space in the building, and ultimately their operation accounts for a large portion of the energy consumed in a building. For these reasons and more, what might first appear as something that can be calculated with just a few formulas in a spreadsheet is instead a software program and, in the case of EnergyPlus, with over 500,000 lines of code.
Questions that BEM can answer[LINK]
The most common questions that BEM can answer are:
These questions and more can occur at different times during the life-cycle of a building, from before schematic design all the way through the rest of the design process, and into the operation of the building
The Design Process and BEM[LINK]
Building energy modeling can be used throughout the design process for a new building or when considering updates to existing buildings. It can also be used later in the life-cycle of a building related to comparing actual operation of the building with the predicted operation. ASHRAE Standard 209 titled “Energy Simulation Aided Design for Buildings Except Low-Rise Residential Buildings” is a critical document in how to apply building energy modeling. It describes a methodology to apply building energy modeling to the design and was created to define reliable and consistent procedures that advance the use of timely energy modeling to quantify the impact of design decisions at the point in time which they are made. The standard includes different “Modeling Cycles” for different stages of using building energy modeling during the life-cycle of the building:
In addition, it has information about how to integrate climate and site analysis, benchmarking, energy charrettes (a meeting of the stakeholders to discuss goals and design strategies) and the energy performance goals of the owners project requirements into the design process when using building energy modeling.
EnergyPlus QuickStart Guide[LINK]
Don’t be intimidated by the apparent complexity of EnergyPlus; you can get started using EnergyPlus quickly using the QuickStart Guide which is part of the documentation. It shows you how you can use just an input file and some output files to start seeing results quickly. The building description, the detecting and solving of errors, and the most common primary outputs are found in the IDF input file, the Table.HTML output file and the .ERR diagnostics file. Starting with these three files and branching out to others as needed is a good strategy for learning EnergyPlus.
EnergyPlus Capabilities[LINK]
According to the energyplus.net web site (as of January 2019):
In addition:
Integration of Loads, Systems, and Plants: One of the strong points of EnergyPlus is the integration of all aspects of the simulation—loads, systems, and plants. System and plant output are allowed to directly impact the building thermal response rather than calculating all loads first, then simulating systems and plants. The simulation is coupled allowing the designer to more accurately investigate the effect of undersizing fans and equipment and what impact that might have on the thermal comfort of occupants within the building.
Open Source[LINK]
EnergyPlus is an Open Source program so all the source code is available to inspect and modify. If you are interested in how calculations are performed and the Engineering Reference does not provide enough details to you, you can review the source code itself. Instructions to build the code (compile the source code into an executable application) are available in the source code repository wiki if you see something that needs to be enhanced or fixed, please also see the contribution policy.
Brief History[LINK]
EnergyPlus has been under development since 1997 and was first released in 2001. EnergyPlus has its roots in both the BLAST and DOE–2 programs. BLAST (Building Loads Analysis and System Thermodynamics) and DOE–2 were both developed and released in the late 1970s and early 1980s as energy and load simulation tools. BLAST was developed by the [Construction](../input-output-reference/group-surface-construction-elements.html#construction-000) Engineering Research Laboratory (CERL) and the University of Illinois while DOE-2 was developed by Berkeley Lab and many others. Their intended audience is a design engineer or architect that wishes to size appropriate HVAC equipment, develop retrofit studies for life cycling cost analyses, optimize energy performance, etc. Born out of concerns driven by the energy crisis of the early 1970s and recognition that building energy consumption is a major component of the American energy usage statistics, the two programs attempted to solve the same problem from two slightly different perspectives. In the late 1990s, concern about limitations of both BLAST and DOE-2 as well as difficulty in maintaining the old code bases prompted combining the development efforts for a new program called EnergyPlus. EnergyPlus was originally written in Fortran, in 2014 it was converted to C++. It was developed as a simulation engine, and many graphical user interfaces utilize it.
Documentation[LINK]
The EnergyPlus documentation is currently included in the installation in the “Documentation” folder as PDFs. It is also available as PDFs online and from third parties that have generated HTML documentation from the source. Using search in the documentation is critical to finding the information needed. Some of the documentation PDFs are very large, so searching is a good way to find specific information about a topic or an input object. The documentation includes:
Example Files[LINK]
Many hundreds of example files come with EnergyPlus, and they are in the ExampleFiles folder from the installation. The \ExampleFiles\ExampleFiles.html lists each one and includes the name, a description (scroll all the way to the right) and lots of information such as the floor area and whether certain types of input objects are included in the file. Often searching through this file is a good way to find the proper example file to learn about a feature. Another method is the \ExampleFiles\ExampleFiles-ObjectsLink.html file which lists every type of input object that EnergyPlus uses and then the first three files that use that input object. It is possible that many other files also use a particular input object so if the first three files do not help, a text search of files in the ExampleFiles folder may find more.
The EnergyPlus Ecosystem[LINK]
Current Interfaces[LINK]
EnergyPlus is often used directly using the text file input (IDF or epJSON) and various output file formats along with the utilities that come with the installation package. More information on that can be found in section [sec:Using-EnergyPlus]. In addition, EnergyPlus is often the simulation engine for graphical user interfaces. To see a list, see the BEST (Building Energy Software Tools) Directory that is operated by IBPSA-USA.
Approaches to Implement Measures[LINK]
In the terminology used within the building energy modeling industry “measures,” sometimes called energy conservation measures (ECMs) or energy efficiency measures (EEMs), are when alternative configurations of a building are considered and simulated and compared with the original building model. Measures include added wall or roof insulation, lower internal lighting power, higher efficiency heating and cooling equipment, and many others. When using EnergyPlus within a graphical user interface, that interface often provides a way to implement various measures. When not working within a graphical user interface, users have several options for implementing measures.
For a specific building input file, a copy of the input file can be made and then modified to reflect the measure. This is an easy approach initially, but since the original building model might change, it means making the change in the file that reflects the measure. When many measures are being considered, this duplicative editing can be inefficient and prone to errors. In addition, the measure cannot be easily applied to a different building energy model without again editing another set of files duplicating the original effort. Due to this, it is very common for some type of scripting to be used so that measures can be applied to the original building model and other models of other buildings reliably and quickly. Scripting in this approach means to apply some type of programming language to the task of modifying files.
EnergyPlus includes, with the installation package, two methods of implementing measures EP-Macro and the ParametricPreprocessor. EP-Macro is similar to the C language pre-processor and allows for portions of the file to be included or excluded, portions of other files to be included when desired, and for specific entries that are normally fixed values to change programmatically. EP-Macro is documented in the AuxiliaryPrograms documentation. A file with lines starting “##” or with the “imf” file extension is likely to be a file using EP-Macro commands.
The EnergyPlus ParametricPreprocessor uses special input objects in EnergyPlus to set values for any field in any other input object for a series of simple options. This is briefly described in the AuxiliaryPrograms documentation, and more details are present in the InputOutputReference under the section on “Parametric Objects.” The ParametricPreprocessor approach is very straight forward, however it has limits in the flexibility that it provides. It is suitable for implementing measures related to internal loads, constructions, and simple efficiency changes but is probably not the appropriate tool for more complicated measures.
A paper that describes various other approaches to scripting was written during the 2018 ASHRAE/IBPSA-USA Building Performance Conference and SimBuild.
Parametric Analysis Tools[LINK]
When just implementing a simple measure or even a series of measures is not enough, a parametric analysis tool may be appropriate. These tools allow the exploration throughout the range of variables (such as the thickness of insulation in the roof or the efficiency of a boiler) to see the impacts of optimization. While many of the approaches used to implement measures described previously may also be used for parametric analysis, a few specific tools have been developed. To see a list, see the BEST (Building Energy Software Tools) Directory that is operated by IBPSA-USA.
Weather Files[LINK]
Weather files are available for many locations throughout the world. Finding the right file that represents the weather in your specific location can sometimes be a challenge. Often the closest weather location is the best one to choose, but sometimes a site that is further away may actually have the most similar weather. This is especially the case in terrain that varies in elevation or when near large bodies of water. Many weather files are available from both public and private sources. The EnergyPlus weather file web site has many weather files with sources described. That web site also has a page with links to many other sites that provide weather files. The modeler must also choose between using a typical year weather files or an actual year file. Typical year files, such as TMY3 and IWEC are representative of long-term weather compiled from 20-30 years of data. Actual year files contain a specific year of weather data and generally used for calibration or verification studies where the simulation results are compared to actual utility bills or other measured data.
Co-Simulation and Linked Software[LINK]
The modelling of multi-domain, multi-physics, and multi-time scale systems such as buildings is a challenge for building energy modelling and simulation tools. In certain circumstances, it may be better for modelling such systems to split the systems into multiple sub-systems, model the individual sub-systems in the language or tool which is best suited for the system’s domain, and use a master algorithm to link the sub-systems for a so called “co-simulation.” In a nutshell, co-simulation consists of the theory and techniques that enable the simulation of a coupled system through the composition of simulators. Each simulator is an input-output mock-up of a constituent system, developed and provided by the team that is responsible for the sub-system. The coupling of the sub-systems is performed by a master algorithm which is responsible for linking the sub-systems at run-time for data-exchange. EnergyPlus implements three mechanisms to support co-simulation.
Getting Help[LINK]
Several resources are available for getting help when using EnergyPlus:
Please do not post questions as issues on the EnergyPlus Github website. Of course, if you are using a graphical user interface with EnergyPlus, the vendor will provide direct support.
After reviewing this document and other pertinent documents that come with EnergyPlus like the InputOutputReference, if additional training is required, several sources are available:
In addition, if you are using a graphical user interface, the vendor probably also provides training.
Using EnergyPlus[LINK]
Installing EnergyPlus[LINK]
Please see the EnergyPlus QuickStart Guide for instructions on how to install EnergyPlus for your system.
Running EnergyPlus[LINK]
EnergyPlus is a simulation engine, so it was designed to be an element within a graphical user interface. However, it can be run standalone without such an interface. There are several options for performing a simulation with EnergyPlus:
In each case, a building model will be simulated in combination with a weather file for the appropriate building location.
Graphical User Interface[LINK]
When running an EnergyPlus simulation within a graphical user interface, the exact method will vary depending on the specific program being used. You should read the documentation for that software to understand how to perform a simulation. In all cases, the interface will ultimately generate an EnergyPlus idf or epjson input file, execute the EnergyPlus simulation, and read the EnergyPlus output files to present results.
Command Line[LINK]
EnergyPlus can be used as a command line tool within a Terminal window in Linux or MacOS or with the CMD prompt or PowerShell window under Windows. Basic usage using the command line approach is well documented in the QuickStart Guide. To learn more about the command line mode, you can type:
when in the EnergyPlus folder. This will give the following display of options:
EnergyPlus can be run by specifying a number of options followed by the path to the input file. The file itself is usually in IDF (Input Data File) format or epJSON format, but it may also be in IMF (Input Macro File) format to be run with EPMacro using the --epmacro option. Each option has a short form (a single-character preceded by a single dash, e.g., -h) and a long form (a more descriptive string of characters preceded by double dashes, e.g., --help). Several of these options are commonly used including the weather, output-prefix, expandobjects, and readvars options. The following are some examples of using the command line options.
Pre-processing using EPMacro and ExpandObjects:
Forcing design-day only simulations:
Giving all output files the prefix being the same as the input file (building.idf) and placing them in a directory called output:
If no arguments are passed on the command line, EnergyPlus expects the input and weather files to be located in the current working directory and name in.idf (or in.epjson) and in.epw respectively.
EP-Launch[LINK]
For users that want a simple way of selecting files and running EnergyPlus, EP-Launch provides this and more. In addition, EP-Launch can help open a text editor for the input and output files, open a spreadsheet for the result files, a web browser for the tabular results file, and start up a viewer for the selected drawing file. There are two different versions of EP-Launch currently part of the EnergyPlus system.
The main screen of EP-Launch 2 is shown below:
It is a Windows program only. EP-Launch 2 is included in the EnergyPlus installation package when installing on Windows, so no additional steps are needed to run it. It is located in the main “root” folder of EnergyPlus, usually, a folder named EnergyPlusVx-x-x, where the x’s are the version number.
In 2018, EP-Launch 3 was developed, and its main screen is shown below:
EP-Launch 3 is not part of the EnergyPlus installation package and needs to be installed separately. It is also open source and is available from GitHub, and it is documented on readthedocs or in the docs folder on GitHub. EP-Launch 3 works on Windows, MacOS, and Linux systems and is written in Python.
While both EP-Launch 2 and EP-Launch 3 do many of the same functions, the interface is quite different. For now, EP-Launch 2 allows groups of files to be run together and has access to some utilities that the newer version does not. EP-Launch 3 works across multiple platforms and is a built from the ground up to be flexible and extensible so that individuals can make their own workflows that run whatever programs they need to run.
IDF and JSON syntax[LINK]
EnergyPlus has two different input file formats that can be used to describe the building and system that is simulated. The file extensions for the two formats are IDF and epJSON. For both input files, the numeric inputs are in SI units (International System of Units often called metric units).
IDF[LINK]
The legacy file format is a text-based format that describes each input object in series. Each input object starts with the type of input object, and each value for each field follows in strict order separated by commas. The end of the input object is indicated by a semi-colon. Comments are indicated by an exclamation point “!” and anything after this is ignored by EnergyPlus. Commonly, an input object is spread over many lines in the file with one value for each field per line. The names of each field are not required but are usually shown after the value and the comma or semicolon as a special comment using “!-” as an indicator. The input objects can be in any order. An example of an input object in an IDF file is shown below:
The details of this example input object are not important, but the use of commas, exclamation points, and the closing semi-colon are important. The IDF format is currently the most commonly used format throughout the EnergyPlus ecosystem of utilities and GUIs. The list of possible input objects and fields is documented in the Energy+.idd file.
A variation on the IDF file format is the IMF file format which includes macros that can be used for parametric analysis or file management called EP-Macros. To learn more about macros see the Input Macros chapter of the AuxiliaryPrograms document.
epJSON[LINK]
A new file format based on the industry standard JSON format most often used to transmit data to and from web servers and web-browser based applications. It is a text-based file format. The JSON format has wide usage across many industries and is supported in just about every modern programming language. It is a field-value style format using brackets and colons to indicate the hierarchy and commas to separate each field and value pair. The input objects must appear grouped by the type of input object. The list of possible input objects and fields is documented in the Energy+.schema.epJSON file which uses json-schema. The same input object shown above in IDF format is shown below in epJSON format:
Converting between IDF and epJSON[LINK]
While the IDF and epJSON file formats are quite different, they contain the same information, and either may be used. In general, if producing EnergyPlus input files using a programming language, the epJSON format might make more sense while, at this point, if producing IDF files using a GUI, they are likely to use the IDF format.
EnergyPlus, when used on the command line, can convert from IDF to epJSON and from epJSON to IDF using the -c or --convert option.
There is also a separate conversion utility ConvertInputFormat.exe in the root EnergyPlus folder. It takes the name of an IDF or epJSON input file (with extension) as an argument. For additional options, type
when in the EnergyPlus folder. This will give the following display of options:
On Windows, you can also drag a file (IDF or epJSON) onto ConvertInputFormat.exe. Note that ConvertInputFormat is version-specific and will not convert an epJSON file that is not the same version.
There are three groups of special input objects which are preprocessor commands: GroundHeatTransfer:*, HVACTemplate:* Parametric:*. ConverInputFormat converts HVACTemplate objects. EnergyPlus does not convert any of these.
Creating and Editing Input Files[LINK]
Since both the IDF and epJSON file formats are text formats, a simple text editor may be used to edit them. Even if not regularly used, a good text editor is an important application to have when working with EnergyPlus. There are many different text editors, and a few have special features related to the IDF format such as syntax highlighting including Atom, Notepad++, and UltraEdit.
Another editing choice for IDF file is the IDF Editor which comes with EnergyPlus in the \PreProcess\IDFEditor directory and can be run directly or from EP-Launch. It is a Windows-only program and was not designed to run on Linux or MacOS. It is specially designed for editing IDF files and includes many features to simplify the process. It performs unit conversions so either SI (metric) or IP (inch-pound) units can be used for editing but the IDF file is always saved in SI units. It can initialize an input object using the default values and has indications when values outside the acceptable range are used. The main screen of the IDF editor is shown below. Full details of the IDF Editor can be found in the Auxiliary Programs document under the “Creating Input Files” section.
Run-Check-Edit Repeat[LINK]
For most building energy modeling projects, whether assisting in early design, refining a design, selecting a control method, or calibrating an existing building, the use of EnergyPlus will be part of a repeating process. The process will probably be in the form of:
Don’t expect that an initial model is ever correct; it is probably not. Initially, errors are likely to exist. The .ERR file should be the first file checked each time EnergyPlus is run. The .ERR file has several levels of messages:
A Fatal error means that EnergyPlus has stopped during the simulation and the input file needs to be fixed before the simulation can be run to completion. Fatal errors should be the first thing fixed. Some Fatal messages reference previous Severe messages so in that case those should be fixed. Since the entire simulation was not performed, it is likely that once the fatal errors are fixed that new Severe and Warning messages will be shown. After all Fatal messages are eliminated, you should work on Severe messages; they should also be fixed. Finally, Warning messages should be reviewed. Often Warning messages are informative and point out unusual configurations, conditions, or choices. If what is being described by the Warning message is as intended, then the Warning message can be ignored. More often, the Warning message points out something that is not as intended and should be fixed or addressed. Since the .ERR file is a text file; you can usually keep it open in a text editor program. Many (but not all) text editor programs will detect that the .ERR file has been updated after each EnergyPlus simulation and lets you load the most recent version.
The next files to be examined are ones that show output results from the simulation. Either the tabular output file (usually an HTML file see Output:Table:SummaryReports and OutputControl:Table:Style) or CSV file (see Output:Variable and Output:Meter) should be examined depending on what you want to look at. Upon examination of the output results, it is very likely that an aspect of the building and its systems are not behaving as expected. For example, the Annual Building Utility Performance Summary report contains a subtable titled Comfort and Setpoint Not Met Summary. If an annual simulation has 100s or 1000s of hours of setpoint not met, then the HVAC system is undersized, or the controls are not working as expected. With an input file representing many thousands of assumptions, some assumptions made by you or as a default of EnergyPlus are likely to be incorrect. Revising the EnergyPlus input file to address this may cause new issues to be shown in the .ERR file so it should always be examined after each change.
To speed the process of running the simulations, you may want only to run a design day (see SimulationControl and SizingPeriod:DesignDay) or a subset of the year (see RunPeriod) while developing and debugging the inputs. This approach speeds up the simulation time itself, and if used, please remember to recheck the .ERR file when running an annual simulation for the first time.
Key Concepts[LINK]
The following sections highlight some key concepts in EnergyPlus
Everything Included[LINK]
One principal that EnergyPlus uses is that (almost) everything is specified in the input file. This means that instead of referencing an external library for materials, schedules, equipment performance, etc., the input objects that fully describe those items should be included directly in the input file. In addition, each input object contains a list of values for every field that needs one. The DataSets folder distributed with EnergyPlus contains these kinds of details and to use them, the input objects should be copied into the input file that you are developing. This approach does make the file include more specification than you might be used to, and typically results in a large input file, but you will have the assurance of knowing that all the inputs related to your building are in the input file you have developed. There are a few exceptions where external data is referenced such as with Schedule:File input objects.
Wall Thickness[LINK]
Exterior and interior walls in real buildings have a thickness as specified on building plans by detailed cross-sections. For EnergyPlus, the Construction input object is made up of a list of names for the Material input objects that make up the wall or roof or floor. Each material input object has a thickness along with the conductivity, density, specific heat and other factors. These thicknesses should match the thicknesses shown in the detailed cross-sections. But when it comes to specifying the walls themselves in three-dimensional space, the walls should be entered assuming zero thickness. Once each surface has been placed, changing the material thickness will have no impact on zone volume, ceiling height, floor area, shading, or daylighting. For most modern buildings the choice of where to locate the wall: inside vs. outside vs. centerline should have little impact on results, so many modelers just pick one and let the volumes be slightly off. Using centerlines throughout the model splits the difference. Or some modelers use outer edges for exterior walls and then use centerlines for interior walls. If you are modeling a very thick wall, such as an old stone building, then you also have thermal mass considerations. If you use the outside edges there will be too much mass, inside will be too little. Again, centerline will split the difference and will be very close to the correct amount of thermal mass (possibly losing some corner mass).
Zones Are Not the Same as Rooms[LINK]
A zone, sometimes called a “thermal zone,” is a theoretical construct that usually describes a group of rooms that can be treated as a single thermal entity. A zone typically includes multiple rooms. Often a zone can be seen as a group of rooms that share a single thermostat. In the case of many similar rooms with the same thermal and operating characteristics, even if many different thermostats are used, they may still be grouped into a single zone in EnergyPlus.
One Construction Per Surface[LINK]
Only one type of construction can be associated with each surface so if the top half of a wall is made up of a different construction than the bottom half of the wall, the top half and the bottom half each need to be represented as separate surfaces.
Available Outputs Created by First Simulation[LINK]
Since EnergyPlus creates a custom list of possible output variables during each simulation, you need to perform a simulation first before you can see them. To create the list use the Output:VariableDictionary input object and then check the .RDD and .MDD files that are created. Select the outputs you want and specify them in the input file.
Always Plan Ahead[LINK]
Some preliminary steps will facilitate the construction of your input file. EnergyPlus requires some information in specified, externally available formats; other information may require some lead time to obtain. The following checklist should be completed before you start to construct your input file.
What Are All These Folders?[LINK]
The installation of EnergyPlus includes many different files in different folders:
Many of these folders include valuable resources for using and learning EnergyPlus.
What Are All These Output Files?[LINK]
When running EnergyPlus using EP-Launch or from the command line, depending on the options selected, many different output files may be generated. The file extensions and file suffixes (added to the original file name prior to the file extension are shown below:
Most of these output files are documented in the Output Files chapter of the OutputDetailsAndExamples document.
Don’t be intimidated by the long list of files; you can do a lot in EnergyPlus with just the IDF input file, the TABLE.HTML file, and the ERR file. The building description, the detecting and solving of errors, and the most common primary outputs are found between these three files. Starting with these three files and branching out to others as needed is a good strategy for using EnergyPlus.
Versions and Updating[LINK]
EnergyPlus version updates are released generally twice per year in March and September. Each version of EnergyPlus is installed to a unique folder, so it is possible, and recommended, to keep older versions in place when adding a new one. This is very helpful if you need to go back and make a change to an older project and don’t want to introduce version-related changes in results. When using the IDF input file format with EnergyPlus, each release is likely to have small changes to the file format. Included with EnergyPlus are a number of ways to update files so that they are compatible with the release. Each method ultimately uses the TransitionVx-x-x-ToVx-x-x.exe files that are located in the Preprocess\IDFVersionUpdater folder. The ways to update your IDF files are:
Errors and How to Fix Them[LINK]
As described in the section dealing with errors described in the ERR file are part of creating files with EnergyPlus. Resolving errors is something that both new and very experienced users have to do. Most of the error message itself, if carefully reviewed will point to the problem. Some error messages will also reference earlier messages that should also be checked. A careful review of the ERR file and the input file will often reveal solutions to the most common errors. Also, see the section.
Data Sets[LINK]
EnergyPlus uses snippets of IDF files to create the library of data that may be useful for you. Two folders are created upon installation: DataSets – which contains IDF snippets and MacroDataSets – which also contain IDF snippets but are in a form such that they can be easily used with the EPMacro program. Another data set are DDY files that accompany each EPW weather file. The DDY files include several varieties of the corresponding design day data for each weather file location.
Other Useful Utility Programs[LINK]
The EnergyPlus install includes a variety of tools to help with various aspects of converting data or displaying information to help with using EnergyPlus
Input Object Groups[LINK]
The following sections provide an overview of the input objects based on groups described in the energy+.idd file and the InputOutputReference. The sections give you a taste of the capabilities and may help guide you to further investigation on how to model your building or a specific energy efficiency measure.
Simulation Parameters[LINK]
EnergyPlus includes a group of input objects used to set general parameters related to how the simulation is performed. Some of these input objects are controlling different options that are allowed within EnergyPlus such as the selection of algorithms to use or parameters related to how an algorithm is used. For a new modeler, these input objects should be included with their default field values. Later when additional control is necessary to model a specific type of measure, the field values can be re-evaluated. The following input object allows you to control how you want the simulation to be performed. The input objects should appear in your file and appear in almost all of the example files:
Two other input objects should appear in your input file and are included in almost all example files:
For a new modeler, the following input objects may be omitted. They can be added later for special cases although they appear in almost all of the example files:
These input objects and more are further explained in the InputOutputReference under the heading “Group-Simulation Parameters.”
Location and Climate[LINK]
Many of the fields in the group of input objects related to location, climate, and the weather file are ones that will be set once for each specific project.
Other input objects in this group can help perform sizing using the weather file, override the sky temperature, impact the variation of outdoor conditions with building height (especially important for tall buildings), work with ground temperatures and ground heat transfer, override the precipitation in weather files, specify the irrigation for a green roof, and some advanced properties related to the light spectrum for window performance. These input objects and more are further explained in the InputOutputReference under the heading “Group-Location and Climate.”
Schedules[LINK]
Many aspects of building operation are characterized by timing whether it is the hours that a building is occupied or when the control systems are in various modes. Due to this, specifying when something occurs using the Schedule input objects becomes one of the most common things to do. It is important to coordinate schedules properly. The operation of office equipment in a space usually corresponds to occupancy of that space as does the thermostat set points and fan operation. Because schedules are such a key input for so many features of a building, a great deal of flexibility exists in EnergyPlus to specify them.
Other input objects in this input group allow specification of schedule values to be in different formats. These input objects and more are further explained in the InputOutputReference under the heading “Group-Schedules.”
Surface Construction Elements[LINK]
Specifying the physical properties of the building envelope is something every building model includes. The input objects in this group allow the specification of the different layers that make up exterior and interior walls, roofs, floors, windows, and skylights as well as the order of the materials in these surfaces. A large number of input objects appear in this group since there are many special features that need to be modeled for certain energy efficiency measures. The following is a list of only the most commonly used input objects.
A large variety of input objects in this group are not as commonly used but are key to modeling specific types of walls and windows so if what you are trying to model does not fall into the neat categories for the input objects described so far, there is still a good chance that EnergyPlus has an input object that will work. These other input objects include ones for walls and roof that can be used when modeling combined heat and moisture transfer, modeling materials which undergo a phase change to store heat in the wall or when the material properties change with temperature, when the material allows infrared radiation to flow through it, when modeling green (vegetated) roofs, for simplified C- or F-factor modeling, or when the wall includes resistance or hydronic tubing to provide heat. The other input objects to describe windows and skylights include input objects that can be used to describe thermochromic and electrochromic glazing, mixtures of gases between layers of glass, vacuum glazing, movable portions of the window assembly such as shades and blinds and screens, alternative ways of specifying fenestration such as equivalent layers or refraction extinction method or ASHWAT model or from a WINDOW program export/data file or specifying wavelength-by-wavelength properties.
The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Surface Construction Elements.”
Thermal Zones and Surfaces[LINK]
The physical aspects of the building such as the walls, roof, and windows, is one of the most important and often challenging aspects of creating a building energy model. In EnergyPlus, the surfaces define the geometry of each zone and thus for the entire building. For many, a graphical user interface will be used to help define the geometric aspects of the building energy model, and many of the input objects described in this section will be directly created by that interface program. It is still important to understand some of the details for these input objects because it is likely that you will be reviewing them as part of debugging error messages. EnergyPlus uses the three dimensional position of each corner of a surface to define the position and orientation of that surface so for a typical rectangular wall that represents 12 numbers and for a typical building with hundreds of surfaces that means thousands of numbers are used to define the geometry of a building so you can see why using an interface is so common.
EnergyPlus uses a right-hand coordinate system as shown in Figure X with three dimensions. The X-axis points east, the Y-axis points north, and the Z-axis points up.
Shading Related[LINK]
Casting shadows on the building, especially onto windows, can significantly impact the energy use of a building, and EnergyPlus includes several input objects to model this effect. The largest impact of shading surfaces is to reduce solar gain through windows that are shaded. There are two kinds of shading surfaces in EnergyPlus, detached and attached. A detached shading surface, such as a tree or neighboring building, is not connected to the building. An attached shading surface is typically an overhang or fin that is attached to a particular base surface of the building, usually a wall; attached shading surfaces are usually designed to shade specific windows.
If using relative coordinates (see GlobalGeometryRules), you may also want to use the Shading:Building:Detailed input object since it will “rotate” with the building. Typically, Shading:Site:Detailed is used for things that are fixed at the site and don’t move with building rotation. Shading:Building:Detailed is for larger structures like a parking garage or canopy which aren’t associated with a specific zone but would likely rotate with the building.
Input Object Variations[LINK]
EnergyPlus includes a bunch of variations on these basic surface input objects that map to a closer representation of real surfaces in buildings. These input objects are effectively just different ways to represent the same information as the BuildingSurface:Detailed, FenestrationSurface:Detailed, and Shading:Zone:Detailed input objects. These input objects are seldom created by graphical user interfaces, so it is unlikely that you will see them. Some of these input objects also have simpler methods for specifying geometry, such as using a single vertex, height, width, tilt, and azimuth or just specifying the fin location relative to the window edge. The following is a list of these input object variations for surfaces:
Other Related Input Objects[LINK]
Other less common input objects include ZoneList and ZoneGroup that can be used when doing multi-story simulations and GeometryTransform which allows a building model to be stretched with just a few inputs.
Internal Gains[LINK]
Inside a building, people, appliances, office equipment, lighting, and other devices produce heat. The combination of all these items that produce heat within a building are called internal gains and represents a significant contribution, sometimes the largest contribution, to the cooling requirements for a building. In addition, they offset the amount of heat from the HVAC system that is needed at a given time. Typically, the peak value is entered in the input objects for this group such as the maximum number of people, the total power of equipment, or the total lighting power and then a schedule is used to modify that value each hour of the year. It is just as critical that the schedule values are realistic for your building as is the peak value. For almost all buildings, it is rare that the peak occupancy occurs for more than a few hours per year if at all and this is especially the case for retail stores, theaters, and sports complexes. Even office buildings when counting vacations and people out of the building for meetings will rarely have peak occupancy.
The most common internal gain input objects that are shown in almost all the example files are:
Less common internal gains input objects include:
Other
The Internal Gains group also contains input objects related to zone contaminant sources and sinks. The input objects include modeling components that impact contaminant concentrations which are scheduled, pressure driven, use a cut off model, assume a decaying source, surface diffusion, or using a deposition velocity model. The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Internal Gains.”
Daylighting[LINK]
Reducing the amount of powered lighting that is used when sufficient natural daylight illuminates the interior building through windows and skylights is called daylighting. Automatics daylighting control systems are a very common energy efficiency measure in buildings and are often required for new building designs depending on the energy code that applies to the building location. The most common input objects related to daylighting are:
The InputOutputReference includes not only a description of these input objects but also extra guidance on how they should be applied. The PurchAirWithDaylighting.idf contains examples of these input objects.
Three different devices can be used with daylighting:
An input object called Daylighting:DELight:ComplexFenestration is used with one of the two control methods specified in the Daylighting:Controls input object when used in conjunction with complex fenestration systems such as prismatic and holographic glass.
Some flexibility is given to provide extra output related to daylighting and includes:
More details of these output options can be found in the OutputDetailsAndExamples document. The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Daylighting.”
Advanced Construction, Surface, Zone Concepts[LINK]
The group of input objects contains many special cases for more sophisticated modeling for constructions, surfaces, and zones. As part of this, one of the ways to model building foundations called Kiva is described. See the ZoneCoupledKivaBasement.idf and ZoneCoupledKivaSlab.idf example files for example of these input objects.
Input objects of interest in this group not related to Kiva include
Other input objects in this group set the heat transfer algorithms for specific surfaces to override the building level heat transfer algorithm, when other models are used to describe the variation in temperature on the outside of a surface, override the algorithm used for modeling convection heat transfer between the air inside or outside of a zone and the surface, vapor transfer coefficients when using algorithms that include moisture modeling of surfaces, override the algorithm that distributes the solar radiation on interior surfaces, overrides the solar energy absorbed by different layers for complex windows, a way to override the longwave radiation with other surfaces in the zone, allows overriding the external environment for a surface or a zone including solar shading or airspeed or temperature or humidity, overrides the source term for the heat balance, or overrides the view factors for a zone. The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Advanced Surface Concepts.”
Exterior Equipment[LINK]
While equipment that is outside of a building does not impact the thermal performance of the building, the accounting of all end-uses including those outside of the building is important for many compliance and incentive programs that require building energy modeling. See the ExteriorLightsAndEq.idf example file for these input objects.
The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Exterior Energy Use Equipment.”
Zone Airflow[LINK]
The Zone Airflow input object group provides a way to model the airflow between zones and airflow due to natural ventilation (e.g., open windows) or mechanically-induced ventilation (e.g., exhaust air fans).
The input objects described in this section are further explained in the InputOutputReference under the heading “Group-Airflow.”
HVAC Templates[LINK]
New users to EnergyPlus need to learn many things to understand how to create detailed input objects for modeling an HVAC system. In order to reduce this initial effort, HVACTemplates were created. Unlike other input objects, the HVACTemplate input objects are not directly processed by EnergyPlus; instead, a preprocessor called ExpandObjects turns these HVACTemplate input objects into the detailed HVAC input objects. This can be used as a learning tool since you can review the .expidf file that contains the detailed input objects or it can be used for long term modeling especially if your focus is not on HVAC related energy efficiency measures. The primary disadvantage of using the HVACTemplate input objects is that only a small subset of possible configurations can be modeled using them; however, the subset of configurations supported by the HVACTemplate input objects was carefully chosen to be some of the most common HVAC configurations. If the HVACTemplate input objects do not support the HVAC configuration you are considering; you need to model it with the detailed HVAC EnergyPlus input objects. When using HVACTemplate input objects, no regular EnergyPlus input objects related to HVAC should be used (see the InputOutputReference for some exceptions to this). The HVACTemplates can model:
The Input Output Reference includes a list of exactly which input objects are needed for each of these configurations
In addition, this group of input objects includes three plant input objects that allow the referencing of chillers, towers, and boilers respectively so that additional details can be described in those input objects. Example for these are in the ExampleFiles directory and start with the name HVACTempate. All of these are described in the “Input/Output Reference” document under the Group “HVACTemplates” and please note that this group is described in Chapter 2 while most of the other groups of input objects are described in Chapter 1. The expansion process is described in the Auxiliary Programs document under “ExpandObjects.”
Detailed HVAC[LINK]
In buildings, HVAC systems are comprised of components such as fans, pumps, coils, chillers and boilers connected by ducts or pipes and controlled by systems using sensors strategically located in the distribution systems and in the zones. In many respects, EnergyPlus mirrors this topology by having a large number of components and a means to describe their connections with one another and their control systems. Every component in an HVAC system must have an inlet and outlet “node.” In the actual system, a node might be a point in the system at which fluid properties can be measured. In an EnergyPlus simulation, the nodes are points at which fluid properties are evaluated and passed on to subsequent equipment. Components are linked together to form various loops within the simulation. Thus, the output node from one component also serves as the inlet node to the next component. Loops are constructed combining the components as well as input objects the describe the arrangement of the components. The figure below shows a generic example of the loop-node concept. Loop nodes are a key defining feature in EnergyPlus. As a result, it is recommended that one of the first steps taken in defining an HVAC system in EnergyPlus be the definition of a node diagram or map. This is helpful for visualization of the entire system.
So that these loops are manageable and more clearly defined both in the input and in the simulation, four different loop sections can be defined in an EnergyPlus input file. In general, these four types are in essence two pairs of loop sections that make up two distinct types of loops: a zone/air loop and a plant loop.
The following is a list of groups of input objects related to specifying detailed HVAC systems in EnergyPlus related to zone equipment and secondary systems:
The following is a list of control systems in EnergyPlus related to HVAC
The following is a list of input objects related to primary systems and equipment:
The input object groups described in this section are further explained in the InputOutputReference.
Output Reporting[LINK]
The primary goal of modeling is seeing the results of the model contained in the output reporting. EnergyPlus has several different types of outputs, but initially the most important to understand are the tabular output reports that summarize the results of the simulation. The Output:Table:SummaryReports and OutputControl:Table:Style input objects described below are the only two necessary to start generating the tabular output reports:
You can also create your own custom tabular reports by using one of the following input objects:
When you need to dive deeper into the results for a specific output variable or output meters, time step outputs allow you to see the values of an output variable for each timestep or other time periods. By looking at multiple output variables and seeing how they change together over time, a deeper understanding of the system and control operation can be gained.
EnergyPlus also includes a number of special reports that usually appear in different output files or in the .eio output file
Environmental reporting adds new meters showing the emissions related to the building and is triggered by the use of the following three input objects. See the 5ZoneTDV.idf file for examples.
Other input objects in this group allow the accumulation of metered results, the combination of output variables or meters to create custom meters, and a method for preprocessors to include error messages in the normal error file. Many example files contain some of these input objects. All of these are described in the “Input/Output Reference” but note that this group is described in Chapter 5 “Input for Output” and Chapter 7 “Standard Output Reports” while most of the other groups of input objects are described in Chapter 1. The OutputDetailsAndExamples documentation provides even more details on the outputs created by each of these input objects. Several other output related input objects appear in other areas such as Output:DaylightFactors input object in the Daylighting group.
Economics[LINK]
EnergyPlus contains several input objects that allow economic analysis to be performed. When these input objects are included in the input file, new tabular output reports are automatically generated. The input objects used by EnergyPlus for cost estimating calculations are as follows:
For many building projects, while energy estimates are important, the computation of estimated utility bills provides an understanding of how much money is going to be saved to help offset possibly higher initial costs of a high-performance building. Due to the many different utility companies and regulatory agencies, the approach used to compute monthly utility bills has become widely varied and, at times, quite complicated depending not only on energy and demand but the timing of each and the relationship between the two. Overall, the goals of the UtilityCost input objects of EnergyPlus are to make simple tariffs easy to model and complex tariffs possible to model. The 5ZoneEconomicsTariffAndLifeCycleCosts.idf example file provides several different example tariffs. The input objects used by EnergyPlus for the calculation of monthly and annual utility bills are as follows:
The following two input objects are uncommon to use:
Life-cycle costing allows the combination of initial and future costs (typically energy bills) to be understood using a single metric so that multiple building energy models can be compared even if they all have different initial and future costs. The input objects used for performing a life-cycle cost analysis are:
Two less commonly used input objects are
All of these are described in the “Input/Output Reference” but note that this group is described in Chapter 3 “EnergyPlus Economics” while most of the other groups of input objects are described in Chapter 1. The OutputDetailsAndExamples documentation provides even more details on the tabular outputs created in the section labeled “eplustbl.<ext>”.
Other Groups of Input Objects[LINK]
The previous sections describe major groups of input objects. This section briefly covers some of the remaining input object groups.