Output:Table:Annual[LINK]
The Output:Table:Annual
object provides a generic method of setting up tables of
annual results with each row corresponding to an instance of
an object. These tables are good for creating reports that
broadly summarize the building performance. At the bottom of
the tables, three rows are added for the sum or average
depending on the type of variable, the maximum and the minimum
of each column. The report produced has multiple columns that
are each defined using a repeated group of fields. The fields
for the variable name and the aggregation type can be repeated
for any number of columns. If the variables from different
type of objects are specified in a single Output:Table:Annual,
all the object names for each type of objects will be shown as
rows. Variables that don’t apply for certain objects will be
left blank for that cell.
The Name field allows the user to give the output table a
label that is shown in the output file.
Field: Filter[LINK]
An optional text string that is compared to the names of
the objects referenced by the variables and if they match are
included in the table. A footnote will appear that indicates
that the objects shown may not be all the objects that of that
type that occur in the file.
Field: Schedule Name[LINK]
Optional schedule name. If left blank, aggregation is
performed for all hours simulated. If a schedule is specified,
aggregation is performed for non-zero hours in the
schedule.
Field: Variable or Meter
<#> Name[LINK]
The remainder of this input object consists of pairs of
fields that can be repeatedVariable Or Meter Name fields
contain the name of a variable (see Output:Variable
and eplusout.rdd), meter (see Output:Meter
and eplusout.mdd), or schedule. This value is shown using the
aggregation method specified. If the selected name is used for
both a variable or a meter and a schedule name, the variable
or meter will be used.
Field:
Aggregation Type for Variable or Meter <#>[LINK]
The aggregation type determines how the variable is
aggregated in the table. The choices for aggregation type are
described below:
Simple Aggregation Types
SumOrAverage – For “sum” type variables
adds up the values for each timestep and reports the sum of
the value. For “average” type variables, the value shown will
be the average for the month. SumOrAverage is probably the
most common choice for aggregation type.
Maximum – Reports the maximum value and
the time that the maximum value occurred. When the maximum
option is used with a summed variable the value is divided by
the length of the timestep in seconds. For example, the
maximum for a variable in Joules is reported in Watts.
Minimum – Reports the minimum value and
the time that the minimum value occurred. When the minimum
option is used with a summed variable the value is divided by
the length of the timestep in seconds. For example, the
minimum for a variable in Joules is reported in Watts.
HoursNonZero – The HoursNonZero option
adds up the elapsed time during the month that this variable
is non-zero and would be appropriate to determine the number
of hour that a fan operates.
HoursZero – The HoursZero option adds up
the elapsed time during the month that this variable has a
zero value and would be appropriate to determine the number of
hour that a fan does not operate.
HoursPositive – The HoursPositive option
adds up the elapsed time during the month that this variable
has a positive value. Hours with a zero value are not
included.
HoursNonPositive – The HoursNonPositive
option adds up the elapsed time during the month that this
variable has non-positive value. Hours with a negative value
and hours with a zero value are all included.
HoursNegative – The HoursNegative option
adds up the elapsed time during the month that this variable
has a negative value. Hours with a zero value are not
included.
HoursNonNegative – The HoursNonNegative
option adds up the elapsed time during the month that this
variable has non-negative value. Hours with a positive value
and hours with a zero value are all included.
HourInTenBinsMinToMax - Creates 10 columns
for the specified variable and shows the number of hours in
each of 10 bins based on the minimum and maximum value. The
bin sizes will be rounded up to the next most significant
digit value (if the min is 0 and the max is 28786.3, the bin
size would be 3000 not 2878.63). A table of the bin ranges
would be generated below the main table when this option is
selected.
HourInTenBinsZeroToMax - Creates 11
columns for the specified variable and shows the number of
hours in each of 10 bins from zero to the maximum value and a
bin for hours below zero. The bin sizes will be rounded up to
the next most significant digit value (if the min is 0 and the
max is 28786.3, the bin size would be 3000 not 2878.63). A
table of the bin ranges would be generated below the main
table when this option is selected.
HourInTenBinsMinToZero - Creates 11
columns for the specified variable and shows the number of
hours in each of 10 bins from zero to the minimum value and a
bin for hours above zero. The bin sizes will be rounded up to
the next most significant digit value (if the min is 0 and the
min is -28786.3, the bin size would be 3000 not 2878.63). A
table of the bin ranges would be generated below the main
table when this option is selected.
Advanced Aggregation Types
The advanced aggregation types are described below. These
aggregation types rely on doing an operation on the current
variable but only during the time or times defined by a
previously defined field. The ValueWhenMaxOrMin displays the
value of one variable at the same time as the maximum or
minimum is set on a previous field that is defined as either a
maximum or minimum. The “Hours—” aggregation types (not
including binning) display then number of hours that a
variable meets a condition. The “—DuringHoursShown”
aggregation types perform those aggregations but instead of
for all the hours in the month, only for the hours that the
previous “Hours—” entry applies. Multiple “—DuringHoursShown”
after an “Hours—” will all be based on that single “Hours—”
entry, in fact the “—DuringHoursShown” is based on the next
column to the left that contains an “Hours—” entry even if
other types of aggregations are used in intermediate columns.
Order of the variables in the report is important when using
the advanced aggregation types since they often depend on a
previous entry.
ValueWhenMaximumOrMinimum – The
ValueWhenMaximumOrMinimum option looks at the previous
variable in the report that sets a maximum or minimum and
displays the value of the current variable at that same
timestep. Order of the variables in the report is important
when using ValueWhenMaxMin. This can be used, for example,
when an outdoor temperature should be reported for the time of
the maximum cooling load.
SumOrAverageDuringHoursShown – Provides
the sum or average of the named variable when during the hours
that the previous variable displayed with any of the
aggregation types starting with “Hours”. For “sum” type
variables adds up the values for each timestep and reports the
sum of the value during the hours reported on the previous
variable. For “average” type variables, the value shown will
be the average for the month during the hours reported on the
previous variable. Order of the variables in the report is
important when using this aggregation type.
MaximumDuringHoursShown – Reports the
maximum value and the time that the maximum value occurred but
only during the hours reported with the previous “hours-”
aggregation type. When the maximum option is used with a
summed variable the value is divided by the length of the
timestep in seconds. For example, the maximum for a variable
in Joules is reported in Watts. Order of the variables in the
report is important when using this aggregation type.
MinimumDuringHoursShown - Reports the
minimum value and the time that the minimum value occurred but
only during the hours reported with the previous “hours-”
aggregation type. When the minimum option is used with a
summed variable the value is divided by the length of the
timestep in seconds. For example, the minimum for a variable
in Joules is reported in Watts. Order of the variables in the
report is important when using this aggregation type.
Field:
Digits After Decimal for Variable or Meter <#>[LINK]
The Digits After Decimal field is a numeric value that
indicates how many digits after the decimal point should be
shown for that column.
The VariableOrMeterName, AggregationType, and
DigitsAfterDecimal fields may be repeated for each column
desired in the annual report. These three fields define each
column of the report. These fields are extensible, so
additional groups of these fields can be added to the end of
this object. An example of this object follows.
Output:Table:Annual,
Custom Annual Window Report,!- Name
, !- Filter
, !- Schedule Name
SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE, !- Variable, Meter, EMS Int Var, IDF field Name 1
SumOrAverage, !- Aggregation Type for 1
2, !- Digits After Decimal for 1
SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE, !- Variable, Meter, EMS Int Var, IDF field Name 2
SumOrAverage, !- Aggregation Type for 2
2, !- Digits After Decimal for 2
SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE, !- Variable, Meter, EMS Int Var, IDF field Name 3
SumOrAverage, !- Aggregation Type for 3
2, !- Digits After Decimal for 3
SURFACE WINDOW HEAT GAIN RATE, !- Variable, Meter, EMS Int Var, IDF field Name 4
SumOrAverage, !- Aggregation Type for 4
2, !- Digits After Decimal for 4
ACE WINDOW HEAT LOSS RATE, !- Variable, Meter, EMS Int Var, IDF field Name 5
SumOrAverage, !- Aggregation Type for 5
2; !- Digits After Decimal for 5
Output:Table:Annual[LINK]
The Output:Table:Annual object provides a generic method of setting up tables of annual results with each row corresponding to an instance of an object. These tables are good for creating reports that broadly summarize the building performance. At the bottom of the tables, three rows are added for the sum or average depending on the type of variable, the maximum and the minimum of each column. The report produced has multiple columns that are each defined using a repeated group of fields. The fields for the variable name and the aggregation type can be repeated for any number of columns. If the variables from different type of objects are specified in a single Output:Table:Annual, all the object names for each type of objects will be shown as rows. Variables that don’t apply for certain objects will be left blank for that cell.
Inputs[LINK]
Field: Name[LINK]
The Name field allows the user to give the output table a label that is shown in the output file.
Field: Filter[LINK]
An optional text string that is compared to the names of the objects referenced by the variables and if they match are included in the table. A footnote will appear that indicates that the objects shown may not be all the objects that of that type that occur in the file.
Field: Schedule Name[LINK]
Optional schedule name. If left blank, aggregation is performed for all hours simulated. If a schedule is specified, aggregation is performed for non-zero hours in the schedule.
Field: Variable or Meter <#> Name[LINK]
The remainder of this input object consists of pairs of fields that can be repeatedVariable Or Meter Name fields contain the name of a variable (see Output:Variable and eplusout.rdd), meter (see Output:Meter and eplusout.mdd), or schedule. This value is shown using the aggregation method specified. If the selected name is used for both a variable or a meter and a schedule name, the variable or meter will be used.
Field: Aggregation Type for Variable or Meter <#>[LINK]
The aggregation type determines how the variable is aggregated in the table. The choices for aggregation type are described below:
Simple Aggregation Types
SumOrAverage – For “sum” type variables adds up the values for each timestep and reports the sum of the value. For “average” type variables, the value shown will be the average for the month. SumOrAverage is probably the most common choice for aggregation type.
Maximum – Reports the maximum value and the time that the maximum value occurred. When the maximum option is used with a summed variable the value is divided by the length of the timestep in seconds. For example, the maximum for a variable in Joules is reported in Watts.
Minimum – Reports the minimum value and the time that the minimum value occurred. When the minimum option is used with a summed variable the value is divided by the length of the timestep in seconds. For example, the minimum for a variable in Joules is reported in Watts.
HoursNonZero – The HoursNonZero option adds up the elapsed time during the month that this variable is non-zero and would be appropriate to determine the number of hour that a fan operates.
HoursZero – The HoursZero option adds up the elapsed time during the month that this variable has a zero value and would be appropriate to determine the number of hour that a fan does not operate.
HoursPositive – The HoursPositive option adds up the elapsed time during the month that this variable has a positive value. Hours with a zero value are not included.
HoursNonPositive – The HoursNonPositive option adds up the elapsed time during the month that this variable has non-positive value. Hours with a negative value and hours with a zero value are all included.
HoursNegative – The HoursNegative option adds up the elapsed time during the month that this variable has a negative value. Hours with a zero value are not included.
HoursNonNegative – The HoursNonNegative option adds up the elapsed time during the month that this variable has non-negative value. Hours with a positive value and hours with a zero value are all included.
HourInTenBinsMinToMax - Creates 10 columns for the specified variable and shows the number of hours in each of 10 bins based on the minimum and maximum value. The bin sizes will be rounded up to the next most significant digit value (if the min is 0 and the max is 28786.3, the bin size would be 3000 not 2878.63). A table of the bin ranges would be generated below the main table when this option is selected.
HourInTenBinsZeroToMax - Creates 11 columns for the specified variable and shows the number of hours in each of 10 bins from zero to the maximum value and a bin for hours below zero. The bin sizes will be rounded up to the next most significant digit value (if the min is 0 and the max is 28786.3, the bin size would be 3000 not 2878.63). A table of the bin ranges would be generated below the main table when this option is selected.
HourInTenBinsMinToZero - Creates 11 columns for the specified variable and shows the number of hours in each of 10 bins from zero to the minimum value and a bin for hours above zero. The bin sizes will be rounded up to the next most significant digit value (if the min is 0 and the min is -28786.3, the bin size would be 3000 not 2878.63). A table of the bin ranges would be generated below the main table when this option is selected.
Advanced Aggregation Types
The advanced aggregation types are described below. These aggregation types rely on doing an operation on the current variable but only during the time or times defined by a previously defined field. The ValueWhenMaxOrMin displays the value of one variable at the same time as the maximum or minimum is set on a previous field that is defined as either a maximum or minimum. The “Hours—” aggregation types (not including binning) display then number of hours that a variable meets a condition. The “—DuringHoursShown” aggregation types perform those aggregations but instead of for all the hours in the month, only for the hours that the previous “Hours—” entry applies. Multiple “—DuringHoursShown” after an “Hours—” will all be based on that single “Hours—” entry, in fact the “—DuringHoursShown” is based on the next column to the left that contains an “Hours—” entry even if other types of aggregations are used in intermediate columns. Order of the variables in the report is important when using the advanced aggregation types since they often depend on a previous entry.
ValueWhenMaximumOrMinimum – The ValueWhenMaximumOrMinimum option looks at the previous variable in the report that sets a maximum or minimum and displays the value of the current variable at that same timestep. Order of the variables in the report is important when using ValueWhenMaxMin. This can be used, for example, when an outdoor temperature should be reported for the time of the maximum cooling load.
SumOrAverageDuringHoursShown – Provides the sum or average of the named variable when during the hours that the previous variable displayed with any of the aggregation types starting with “Hours”. For “sum” type variables adds up the values for each timestep and reports the sum of the value during the hours reported on the previous variable. For “average” type variables, the value shown will be the average for the month during the hours reported on the previous variable. Order of the variables in the report is important when using this aggregation type.
MaximumDuringHoursShown – Reports the maximum value and the time that the maximum value occurred but only during the hours reported with the previous “hours-” aggregation type. When the maximum option is used with a summed variable the value is divided by the length of the timestep in seconds. For example, the maximum for a variable in Joules is reported in Watts. Order of the variables in the report is important when using this aggregation type.
MinimumDuringHoursShown - Reports the minimum value and the time that the minimum value occurred but only during the hours reported with the previous “hours-” aggregation type. When the minimum option is used with a summed variable the value is divided by the length of the timestep in seconds. For example, the minimum for a variable in Joules is reported in Watts. Order of the variables in the report is important when using this aggregation type.
Field: Digits After Decimal for Variable or Meter <#>[LINK]
The Digits After Decimal field is a numeric value that indicates how many digits after the decimal point should be shown for that column.
The VariableOrMeterName, AggregationType, and DigitsAfterDecimal fields may be repeated for each column desired in the annual report. These three fields define each column of the report. These fields are extensible, so additional groups of these fields can be added to the end of this object. An example of this object follows.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.