Programming Style[LINK]
Some of the issues related to programming style have
already been discussed in the Fortran 90/95 Code
section above and will not be repeated here. In order to
complete the discussion of style within program code, it is
necessary to step back and review the goals of the project.
Members of the project team determined that two of the most
important features for the EnergyPlus code were
maintainability and understandability. The key to achieving
these characteristics is to use uniform, simple code for as
much programming as possible. Algorithm tasks should be well
defined and documented.
The next section contains a code template that is to be
used with all EnergyPlus modules. This template will help
promote uniformity between various sections of the EnergyPlus
code.
Code Template[LINK]
MODULE <module_name>
! Module containing the routines dealing with the <module_name>
! MODULE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS MODULE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! OTHER NOTES:
! na
! USE STATEMENTS:
! <use statements for data only modules>
USE DataGlobals, ONLY: ShowWarningError, ShowSevereError, ShowFatalError, &
MaxNameLength, ...
! <use statements for access to subroutines in other modules>
IMPLICIT NONE ! Enforce explicit typing of all variables
PRIVATE ! Everything private unless explicitly made public
! MODULE PARAMETER DEFINITIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! MODULE VARIABLE DECLARATIONS:
! na
! SUBROUTINE SPECIFICATIONS FOR MODULE:
! Driver/Manager Routines
PUBLIC Sim<module_name>
! Get Input routines for module
PRIVATE Get<module_name>
! Initialization routines for module
PRIVATE Init<module_name>
! Algorithms/Calculation routines for the module
PRIVATE Calc<module_name>
! Update routines to check convergence and update nodes
PRIVATE Update<module_name>
! Reporting routines for module
PRIVATE Report<module_name>
! Utility routines for module
! these would be public such as:
! PUBLIC Get<module>InletNode
! PUBLIC Get<module>OutletNode
CONTAINS
SUBROUTINE Sim<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
LOGICAL,SAVE :: GetInputFlag = .true. ! First time, input is "gotten"
IF (GetInputFlag) THEN
CALL Get<module_name>Input
GetInputFlag=.false.
ENDIF
<... insert any necessary code here>
CALL Init<module_name>(Args)
CALL Calc<module_name>(Args)
CALL Update<module_name>(Args)
CALL Report<module_name>(Args)
RETURN
END SUBROUTINE Sim<module_name>
SUBROUTINE Get<module_name>Input
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
USE InputProcessor, ONLY: GetNumObjectsFound, GetObjectItem ! might also use FindItemInList
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
INTEGER :: Item ! Item to be "gotten"
CHARACTER(len=MaxNameLength), &
DIMENSION(x) :: Alphas ! Alpha items for object
REAL, DIMENSION(y) :: Numbers ! Numeric items for object
INTEGER :: NumAlphas ! Number of Alphas for each GetObjectItem call
INTEGER :: NumNumbers ! Number of Numbers for each GetObjectItem call
INTEGER :: IOStatus ! Used in GetObjectItem
LOGICAL :: ErrorsFound=.false. ! Set to true if errors in input, fatal at end of routine
<NumItems>=GetNumObjectsFound('object for <module_name>')
DO Item=1,<NumItems>
CALL GetObjectItem('object for <module_name>', Item, Alphas, NumAlphas, Numbers, NumNumbers, &
IOStatus)
<process, noting errors>
ENDDO
<SetupOutputVariables here...>
IF (ErrorsFound) THEN
CALL ShowFatalError('Get<module_name>Input: Errors found in input')
ENDIF
RETURN
END SUBROUTINE Get<module_name>Input
SUBROUTINE Init<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Init<module_name>
SUBROUTINE Size<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS
! na
! DERIVED TYPE DEFINITIONS
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Size<module_name>
SUBROUTINE Calc<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Calc<module_name>
SUBROUTINE Update<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
RETURN
END SUBROUTINE Update<module_name>
SUBROUTINE Report<module_name>
! SUBROUTINE INFORMATION:
! AUTHOR <author>
! DATE WRITTEN <date_written>
! MODIFIED na
! RE-ENGINEERED na
! PURPOSE OF THIS SUBROUTINE:
! <description>
! METHODOLOGY EMPLOYED:
! <description>
! REFERENCES:
! na
! USE STATEMENTS:
! na
IMPLICIT NONE ! Enforce explicit typing of all variables in this routine
! SUBROUTINE ARGUMENT DEFINITIONS:
! na
! SUBROUTINE PARAMETER DEFINITIONS:
! na
! INTERFACE BLOCK SPECIFICATIONS:
! na
! DERIVED TYPE DEFINITIONS:
! na
! SUBROUTINE LOCAL VARIABLE DECLARATIONS:
! na
! <this routine is typically needed only for those cases where you must transform the internal data to a reportable form>
RETURN
END SUBROUTINE Report<module_name>
!===================== Utility/Other routines for module.
! Insert as appropriate
! Insert Standard Copyright Notice here.
END MODULE <module_name>
Notes on the
EnergyPlus Code Template[LINK]
Programmers should copy the above text into an empty file,
changing names and filling in comments and code as
appropriate. Comments in the template that are enclosed in
{{double braces}} should be replaced with actual comments
specific to the module or subroutine. Comments that are
enclosed in <> should be replaced with
program code. Other comments should be left in the file as
they are. Note that some of the comments appear in all capital
letters while others appear in mixed case. These all
capitalized comments are special “header” comments. Developer
comments should be in sentence case rather than all upper
case. All comments (including in-line comments) should begin
in the 11th column or later to help set them off
visually from the code. In-line comments should leave at least
one blank character between the end of the syntax and the
comment marker. Furthermore, it should be noted that the
indentation of program code did not begin until the subroutine
level had been reached. Finally, functions may be added in a
similar manner as the subroutines.
Good Coding Practices[LINK]
Though we hope that the interfaces to EnergyPlus will
produce correct input files, this may not be the case.
Therefore, you should program defensively when accepted
incorrect data will cause your routines to go “belly-up”. For
example, the “ShowFatalError” routine is called in the code
example (Ref: Module Developer’s Guide) when the
“SimulateFanComponents” is passed a fan name that it cannot
find in the list of fans. Ideally, this kind of error-checking
should be accomplished during the “Get” routines for the
module. Nevertheless, having this detection somewhere
(anywhere) will save countless hours of debugging an incorrect
input file.
Code
Readability vs. Speed of Execution[LINK]
Programmers throughout time have had to deal with speed of
code execution and it’s an ongoing concern. However, compilers
are pretty smart these days and, often, can produce speedier
code for the hardware platform than the programmer can when he
or she uses “speed up” tips. The EnergyPlus development team
would rather the code be more “readable” to all than to try to
outwit the compilers for every platform. First and foremost,
the code is the true document of what EnergyPlus does - other
documents will try to explain algorithms and such but must
really take a back seat to the code itself.
However, many people may read the code - as developers, we
should try to make it as readable at first glance as possible.
For a true example from the code and a general indication of
preferred style, take the case of the zone temperature update
equation. In the engineering document, the form is
recognizable and usual:
And, this equation appears
in the code (ZoneTempPredictorCorrector Module), as:
ZT(ZoneNum)= (CoefSumhat + CoefAirrat*(3.0d0*ZTM1(ZoneNum) - (3.0d0/2.0d0)*ZTM2(ZoneNum) &
+ (1.d0/3.d0)* ZTM3(ZoneNum))) &
/ ((11.0d0/6.0d0)*CoefAirrat+CoefSumha)
somewhat abbreviated here due to lack of page width but
still recognizable from the original. A better version would
actually be:
ZT(ZoneNum)= (CoefSumhat - CoefAirrat*(-3.0d0*ZTM1(ZoneNum) + (3.0d0/2.0d0)*ZTM2(ZoneNum) &
- (1.d0/3.d0)* ZTM3(ZoneNum))) &
/ ((11.0d0/6.0d0)*CoefAirrat+CoefSumha)
whereas the natural tendency of programming would lead to
the less readable:
ZT(ZoneNum)= (CoefSumhat + CoefAirrat*(3.0d0*ZTM1(ZoneNum) &
- 1.5d0*ZTM2(ZoneNum) + .333333d0* ZTM3(ZoneNum))) &
/ (1.83333d0*CoefAirrat+CoefSumha)
The final version is a correct translation (more or less)
from the Engineering/usual representation but much harder to
look at in code and realize what is being represented. Also,
due to all double precision being used, .333333d0 may not be
the best representation that the machine can make for 1/3.
This discussion also appears in the Module Developer’s
Guide.
Programming Style[LINK]
Some of the issues related to programming style have already been discussed in the Fortran 90/95 Code section above and will not be repeated here. In order to complete the discussion of style within program code, it is necessary to step back and review the goals of the project. Members of the project team determined that two of the most important features for the EnergyPlus code were maintainability and understandability. The key to achieving these characteristics is to use uniform, simple code for as much programming as possible. Algorithm tasks should be well defined and documented.
The next section contains a code template that is to be used with all EnergyPlus modules. This template will help promote uniformity between various sections of the EnergyPlus code.
Code Template[LINK]
Notes on the EnergyPlus Code Template[LINK]
Programmers should copy the above text into an empty file, changing names and filling in comments and code as appropriate. Comments in the template that are enclosed in {{double braces}} should be replaced with actual comments specific to the module or subroutine. Comments that are enclosed in <> should be replaced with
program code. Other comments should be left in the file as
they are. Note that some of the comments appear in all capital
letters while others appear in mixed case. These all
capitalized comments are special “header” comments. Developer
comments should be in sentence case rather than all upper
case. All comments (including in-line comments) should begin
in the 11th column or later to help set them off
visually from the code. In-line comments should leave at least
one blank character between the end of the syntax and the
comment marker. Furthermore, it should be noted that the
indentation of program code did not begin until the subroutine
level had been reached. Finally, functions may be added in a
similar manner as the subroutines.
Good Coding Practices[LINK]
Though we hope that the interfaces to EnergyPlus will produce correct input files, this may not be the case. Therefore, you should program defensively when accepted incorrect data will cause your routines to go “belly-up”. For example, the “ShowFatalError” routine is called in the code example (Ref: Module Developer’s Guide) when the “SimulateFanComponents” is passed a fan name that it cannot find in the list of fans. Ideally, this kind of error-checking should be accomplished during the “Get” routines for the module. Nevertheless, having this detection somewhere (anywhere) will save countless hours of debugging an incorrect input file.
Code Readability vs. Speed of Execution[LINK]
Programmers throughout time have had to deal with speed of code execution and it’s an ongoing concern. However, compilers are pretty smart these days and, often, can produce speedier code for the hardware platform than the programmer can when he or she uses “speed up” tips. The EnergyPlus development team would rather the code be more “readable” to all than to try to outwit the compilers for every platform. First and foremost, the code is the true document of what EnergyPlus does - other documents will try to explain algorithms and such but must really take a back seat to the code itself.
However, many people may read the code - as developers, we should try to make it as readable at first glance as possible. For a true example from the code and a general indication of preferred style, take the case of the zone temperature update equation. In the engineering document, the form is recognizable and usual:
somewhat abbreviated here due to lack of page width but still recognizable from the original. A better version would actually be:
whereas the natural tendency of programming would lead to the less readable:
The final version is a correct translation (more or less) from the Engineering/usual representation but much harder to look at in code and realize what is being represented. Also, due to all double precision being used, .333333d0 may not be the best representation that the machine can make for 1/3.
This discussion also appears in the Module Developer’s Guide.