HVAC System Types[LINK]
What kind of systems are available in
EnergyPlus?
EnergyPlus HVAC systems input is flexible, so many
different types of systems can be built using the basic
available components. There are also compound components which
represent common equipment types, and HVACTemplate systems
which simplify the input for specific systems. This list gives
an overview of HVAC objects in EnergyPlus:
HVAC Templates
HVACTemplate:ThermostatHVACTemplate:Zone:IdealLoadsAirSystemHVACTemplate:Zone:FanCoilHVACTemplate:Zone:PTACHVACTemplate:Zone:PTHPHVACTemplate:Zone:UnitaryHVACTemplate:Zone:VAVHVACTemplate:Zone:VAV:FanPoweredHVACTemplate:Zone:WaterToAirHeatPumpHVACTemplate:System:UnitaryHVACTemplate:System:Unitary:AirToAirHVACTemplate:System:VAVHVACTemplate:System:PackagedVAVHVACTemplate:System:DedicatedOutdoorAirHVACTemplate:Plant:ChilledWaterLoopHVACTemplate:Plant:ChillerHVACTemplate:Plant:TowerHVACTemplate:Plant:HotWaterLoopHVACTemplate:Plant:BoilerHVACTemplate:Plant:MixedWaterLoop
Zone
HVAC Forced Air Units
ZoneHVAC:IdealLoadsAirSystemZoneHVAC:FourPipeFanCoilZoneHVAC:WindowAirConditionerZoneHVAC:PackagedTerminalAirConditionerZoneHVAC:PackagedTerminalHeatPumpZoneHVAC:WaterToAirHeatPumpZoneHVAC:Dehumidified:DXZoneHVAC:EnergyRecoveryVentilatorZoneHVAC:EnergyRecoveryVentilator:ControllerZoneHVAC:UnitVentilatorZoneHVAC:UnitHeaterZoneHVAC:OutdoorAirUnitZoneHVAC:TerminalUnit:VariableRefrigerantFlow
Zone
HVAC Radiative/Convective Units
ZoneHVAC:Baseboard:RadiantConvective:WaterZoneHVAC:Baseboard:RadiantConvective:SteamZoneHVAC:Baseboard:RadiantConvective:ElectricZoneHVAC:Baseboard:Convective:WaterZoneHVAC:Baseboard:Convective:ElectricZoneHVAC:LowTemperatureRadiant:VariableFlowZoneHVAC:LowTemperatureRadiant:ConstantFlowZoneHVAC:LowTemperatureRadiant:ElectricZoneHVAC:HighTemperatureRadiantZoneHVAC:VentilatedSlab
Zone
HVAC Air Loop Terminal Units
AirTerminal:SingleDuct:UncontrolledAirTerminal:SingleDuct:ConstantVolume:ReheatAirTerminal:SingleDuct:VAV:NoReheatAirTerminal:SingleDuct:VAV:ReheatAirTerminal:SingleDuct:VAV:Reheat:VariableSpeedFanAirTerminal:SingleDuct:VAV:HeatAndCool:NoReheatAirTerminal:SingleDuct:VAV:HeatAndCool:ReheatAirTerminal:SingleDuct:SeriesPIU:ReheatAirTerminal:SingleDuct:ParallelPIU:ReheatAirTerminal:SingleDuct:ConstantVolume:FourPipeInductionAirTerminal:SingleDuct:ConstantVolume:CooledBeamAirTerminal:DualDuct:ConstantVolumeAirTerminal:DualDuct:VAVAirTerminal:DualDuct:VAV:OutdoorAirZoneHVAC:AirDistributionUnit
Fans
Fan:ConstantVolumeFan:VariableVolumeFan:OnOffFan:ZoneExhaustFanPerformance:NightVentilationFan:ComponentModel
Coils
Coil:Cooling:WaterCoil:Cooling:Water:DetailedGeometryCoil:Cooling:DX:SingleSpeedCoil:Cooling:DX:TwoSpeedCoil:Cooling:DX:MultiSpeedCoil:Cooling:DX:TwoStageWithHumidityControlModeCoilPerformance:DX:CoolingCoil:Cooling:DX:VariableRefrigerantFlowCoil:Heating:DX:VariableRefrigerantFlowCoil:Heating:WaterCoil:Heating:SteamCoil:Heating:ElectricCoil:Heating:GasCoil:Heating:DesuperheaterCoil:Heating:DX:SingleSpeedCoil:Heating:DX:MultiSpeedCoil:Cooling:WaterToAirHeatPump:ParameterEstimationCoil:Heating:WaterToAirHeatPump:ParameterEstimationCoil:Cooling:WaterToAirHeatPump:EquationFitCoil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFitCoil:Heating:WaterToAirHeatPump:EquationFitCoil:Heating:WaterToAirHeatPump:VariableSpeedEquationFitCoil:WaterHeating:AirToWaterHeatPumpCoil:WaterHeating:DesuperheaterCoilSystem:Cooling:DXCoilSystem:Heating:DXCoilSystem:Cooling:Water:HeatExchangerAssistedCoilSystem:Cooling:DX:HeatExchangerAssisted
Evaporative Coolers
EvaporativeCooler:Direct:CelDekPadEvaporativeCooler:Indirect:CelDekPadEvaporativeCooler:Indirect:WetCoilEvaporativeCooler:Indirect:ResearchSpecial
Humidifiers and Dehumidifiers
Humidifier:Steam:ElectricDehumidifier:Desiccant:NoFansDehumidifier:Desiccant:System
Heat Recovery
HeatExchanger:AirToAir:FlatPlateHeatExchanger:AirToAir:SensibleAndLatentHeatExchanger:Desiccant:BalancedFlowHeatExchanger:Desiccant:BalancedFlow:PerformanceDataType1
Unitary Equipment
AirLoopHVAC:Unitary:Furnace:HeatOnlyAirLoopHVAC:Unitary:Furnace:HeatCoolAirLoopHVAC:UnitaryHeatOnlyAirLoopHVAC:UnitaryHeatCoolAirLoopHVAC:UnitaryHeatPump:AirToAirAirLoopHVAC:UnitaryHeatPump:WaterToAirAirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypassAirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed
Variable Refrigerant Flow Equipment
AirConditioner:VariableRefrigerantFlow
Air Distribution
AirLoopHVACAirLoopHVAC:OutdoorAirSystem:EquipmentListAirLoopHVAC:OutdoorAirSystemOutdoorAir:MixerAirLoopHVAC:ZoneSplitterAirLoopHVAC:SupplyPlenumAirLoopHVAC:SupplyPathAirLoopHVAC:ZoneMixerAirLoopHVAC:ReturnPlenumAirLoopHVAC:ReturnPath
Pumps
Pump:VariableSpeedPump:ConstantSpeedPump:VariableSpeed:CondensateHeaderedPumps:VariableSpeedHeaderedPumps:ConstantSpeed
Solar Collectors
SolarCollectorPerformance:FlatPlateSolarCollector:FlatPlate:WaterSolarCollector:FlatPlate:PhotovoltaicThermalSolarCollectorPerformance:PhotovoltaicThermal:SimpleSolarCollector:IntegralCollectorStorageSolarCollectorPerformance:IntegralCollectorStorageSolarCollector:UnglazedTranspiredSolarCollector:UnglazedTranspired:Multisystem
Plant Heating and Cooling Equipment
Boiler:HotWaterBoiler:SteamChiller:Electric:EIRChiller:Electric:ReformulatedEIRChiller:ElectricChiller:Absorption:IndirectChiller:AbsorptionChiller:ConstantCOPChiller:EngineDrivenChiller:CombustionTurbineChillerHeater:Absorption:DirectFiredChillerHeater:Absorption:DoubleEffectHeatPump:WaterToWater:EquationFit:HeatingHeatPump:WaterToWater:EquationFit:CoolingHeatPump:WaterToWater:ParameterEstimation:CoolingHeatPump:WaterToWater:ParameterEstimation:HeatingDistrictCoolingDistrictHeating
Condenser Equipment and Heat Exchangers
CoolingTower:SingleSpeedCoolingTower:TwoSpeedCoolingTower:VariableSpeedCoolingTowerPerformance:CoolToolsCoolingTowerPerformance:YorkCalcEvaporativeFluidCooler:SingleSpeedEvaporativeFluidCooler:TwoSpeedFluidCooler:SingleSpeedFluidCooler:TwoSpeedGroundHeatExchanger:VerticalGroundHeatExchanger:PondGroundHeatExchanger:SurfaceHeatExchanger:FluidToFluid
Water Heaters and Thermal Storage
WaterHeater:MixedWaterHeater:StratifiedWaterHeater:SizingWaterHeater:HeatPumpThermalStorage:Ice:SimpleThermalStorage:Ice:DetailedThermalStorage:ChilledWater:MixedThermalStorage:ChilledWater:Stratified
Plant-Condenser Loops
PlantLoopCondenserLoopPipe:AdiabaticPipe:Adiabatic:SteamPipe:IndoorPipe:OutdoorPipe:Underground
HVAC System Types[LINK]
What kind of systems are available in EnergyPlus?
EnergyPlus HVAC systems input is flexible, so many different types of systems can be built using the basic available components. There are also compound components which represent common equipment types, and HVACTemplate systems which simplify the input for specific systems. This list gives an overview of HVAC objects in EnergyPlus: