The module InputProcessor processes the input data
files (IDFs). It also reads and parses the IDD file. The
InputProcessor uses the definition lines in the IDD as
directives on how to process each input object in the IDF.
The InputProcessor also turns all alpha strings into all UPPER
CASE. Currently, it does nothing else to those strings – so
the number of blanks in a string must match what the
calculational modules expect. The InputProcessor processes
all numeric strings into single precision real numbers.
Special characters, such as tabs, should not be
included in the IDF.
The EnergyPlus module InputProcessor provides
several routines - generically called the “get” routines –
that enable the developer to readily access the data for a new
module. These routines are made available by including a “USE
InputProcessor” statement in the module or in the routine that
will use the “get” routines. The GetFanInput subroutine in
the example illustrates some of the uses of the “get”
routines.
The following objects use public routines from the
InputProcessor. To access these, the code has:
Use InputProcessor, ONLY: <routine1>,
<routine2>
Where the <routine> is one or more of the
following:
GetNumObjectsFound[LINK]
This function returns the number of objects in the input
belonging to a particular class. In other terms, it returns
the number of instances in the input of a particular
component.
Example:
USE InputProcessor, ONLY: GetNumObjectsFound
NumVAVSys = GetNumObjectsFound(‘SINGLE
DUCT:VAV:REHEAT’)
Here NumVAVSys will contain the number of single duct VAV
terminal units in the input data file (IDF). SINGLE
DUCT:VAV:REHEAT is the class name or keyword defining VAV
terminal unit input on the IDD file.
GetObjectItem[LINK]
This subroutine is used to obtain the actual alphanumeric
and numeric data for a particular object.
Example:
USE InputProcessor
INTEGER :: SysNum = 0 ! The Sys that you are
currently loading input into
CHARACTER(Len = MaxNameLength) ::
CurrentModuleObject
CHARACTER(Len = MaxNameLength), ALLOCATABLE,
DIMENSION(:) :: Alphas
CHARACTER(Len = MaxNameLength), ALLOCATABLE,
DIMENSION(:) :: cAlphaFields
CHARACTER(Len = MaxNameLength), ALLOCATABLE,
DIMENSION(:) :: cNumericFields
REAL(r64), ALLOCATABLE, DIMENSION(:) :: Numbers
LOGICAL, ALLOCATABLE, DIMENSION(:) ::
lAlphaBlanks
LOGICAL, ALLOCATABLE, DIMENSION(:) ::
lNumericBlanks
INTEGER :: MaxNums = 0
INTEGER :: MaxAlphas =
0
INTEGER :: TotalArgs =
0
CALL GetObjectDefMaxArgs &
(‘AirTerminal:SingleDuct:VAV:Reheat’,
TotalArgs, NumAlphas, NumNums)
MaxNums = MAX(MaxNums,NumNums)
MaxAlphas = MAX(MaxAlphas,NumAlphas)
!Start Loading the System Input
CurrentModuleObject = ‘AirTerminal:SingleDuct:VAV:Reheat’
DO SysIndex = 1, NumVAVSys
CALL GetObjectItem &
(TRIM(CurrentModuleObject),SysIndex,Alphas,NumAlphas,Numbers,NumNums,
&
IOSTAT,AlphaBlank = lAlphaBlanks,NumBlank =
lNumericBlanks, &
AlphaFieldnames = cAlphaFields,NumericFieldNames =
cNumericFields)
SysNum = SysIndex
— Check to make sure no duplicate names entered
Sys(SysNum)%SysName = Alphas(1)
Sys(SysNum)%SysType =
TRIM(CurrentModuleObject)
Sys(SysNum)%SysType_Num = SingleDuctVAVReheat
END DO
Here GetObjectItem is called with inputs (‘AirTerminal:SingleDuct:VAV:Reheat’)
– passed as CurrentModuleObject the class of object we want
to input – and SysIndex – the index of the object on the input
file. If SysIndex is 3, the call to GetObjectItem will get the
data for the third VAV terminal unit on the input file. Output
is returned in the remaining arguments. AlphArray contains in
order all the alphanumeric data items for a single VAV
terminal unit. NumArray contains all the numeric data items.
NumAlphas is the number of alphanumeric items read; NumNums is
the number of numeric data items read. IOSTAT is a status
flag: -1 means there was an error; +1 means the input was OK.
AlphArray and NumArray should be dimensioned to handle the
largest expected input for the item – which in this case is
set from a call to GetObjectDefMaxArgs.
NumBlank is an optional argument to the routine – it can be
used to determine if a numeric field was entered as “blank”
rather than the filled value of 0.0. Likewise for NumFields
and the others.
These are used to make the potential error messages from
the GetInput routine correspond more closely to the IDD
nomenclature, but look a bit funny in use:
IF (Sys(SysNum)%SchedPtr = = 0) THEN
CALL ShowSevereError( &
RoutineName//trim(CurrentModuleObject)//’ = “’//
&
TRIM(Sys(SysNum)%SysName)//‘“, invalid schedule.’)
CALL ShowContinueError(TRIM(cAlphaFields(2))//’ = ’//
&
TRIM(Alphas(2))//’ not found.’)
ErrorsFound = .true.
ENDIF
More information about standard error message formatting is
contained in the Output
Details and Examples document (for the user) and (for the
developer) in this document section: Standard Message
Format.
GetObjectDefMaxArgs[LINK]
While developers do their best to guess how many items are
needed in an object, users will often want to extend that
object with far more fields than were dreamed of. Using
Allocatable arrays in Fortran usually makes this feasible, the
special \extensible field makes it possible.
Example:
USE InputProcessor, ONLY: GetObjectDefMaxArgs
CHARACTER(len = MaxNameLength), ALLOCATABLE, DIMENSION(:)
:: Alphas
REAL, ALLOCATABLE, DIMENSION(:) ::
Numbers
! You supply the object word, routine returns numargs,
numalpha, numnumeric
CALL
GetObjectDefMaxArgs(‘DAYSCHEDULE:INTERVAL’,NumArgs,NumAlpha,NumNumeric)
ALLOCATE(Alphas(NumAlpha))
ALLOCATE(Numbers(NumNumeric))
! Then, usual get calls…
Thus, you can determine how many arguments that the IDD has
defined as “maximum” for a given object.
GetObjectItemNum[LINK]
GetObjectItem, described above, requires the input file
index of the desired object in order to get the object’s data.
Sometimes this index may be unknown, but the name of the
object is known. GetObjectItemNum returns the input file index
given the class name and object name.
Example:
USE InputProcessor, ONLY: GetObjectItemNum
ListNum = GetObjectItemNum(‘CONTROLLER
LIST’,ControllerListName)
In the example, ListNum will contain the input file index
of the ‘CONTROLLER LIST’ whose name is contained in the string
variable ControllerListName.
FindItemInList[LINK]
This function looks up a string in a similar list of items
and returns the index of the item in the list, if found. It is
case sensitive.
Example:
USE InputProcessor, ONLY: FindItemInList
SysNum =
FindItemInList(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of
names to be searched, and NumSys is the size of the list.
Case insensitive version of the FindItemInList.
Example:
USE InputProcessor, ONLY: FindItem
SysNum =
FindItem(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of
names to be searched, and NumSys is the size of the list.
FindItemInSortedList[LINK]
This function looks up a string in a sorted list of items
and returns the index of the item in the list, if found. It is
case sensitive.
Example:
USE InputProcessor, ONLY: FindItemInSortedList
SysNum =
FindItemInSortedList(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of
names to be searched, and NumSys is the size of the list. See
quick sort utility – most lists are NOT sorted in
EnergyPlus.
This function returns true if two strings are equal (case
insensitively).
Example:
USE InputProcessor, ONLY: SameString
IF
(SameString(InputRoughness,‘VeryRough’))
THEN
Material(MaterNum)%Roughness = VeryRough
ENDIF
This subroutine checks that an object name is unique; that
is, it hasn’t already been used for the same class of object
and the name is not blank.
Example:
USE InputProcessor, ONLY: VerifyName
CALL VerifyName(AlphArray(1),Fan%FanName,
&
FanNum-1,IsNotOK,IsBlank,‘FAN:SIMPLE:CONSTVOLUME
Name’)
The first argument is the name to be checked, the second is
the list of names to search, the third argument is the number
of entries in the list, the 4th argument is set to
TRUE if verification fails, the 5th argument is set
to true if the name is blank, and the last argument is part of
the error message written to the error file when verification
fails.
The routine RangeCheck can be used to produce a reasonable
error message to describe the situation in addition to setting
the ErrorsFound variable to true. Errors found can then be
checked in the calling routine and the program terminated if
desired.
SUBROUTINE
RangeCheck(ErrorsFound,WhatFieldString,WhatObjectString,ErrorLevel,
&
LowerBoundString,LowerBoundCondition,UpperBoundString,UpperBoundCondition)
It can be used in a variety of places when the \minimum and
\maximum fields will not work (e.g. different min/max
dependent on some other field).
USE InputProcessor, ONLY: RangeCheck
ErrorsFound = .false.
CALL RangeCheck(ErrorsFound,‘DryBulb
Temperature’,‘WeatherFile’, &
‘SEVERE’,‘> -70’,(Drybulb>-70.),‘<
70’,(DryBulb <70.))
CALL RangeCheck(ErrorsFound,‘DewPoint
Temperature’,‘WeatherFile’, &
‘SEVERE’,‘>
-70’,(Dewpoint>-70.),‘< 70’,(Dewpoint <70.))
CALL RangeCheck(ErrorsFound,‘Relative
Humidity’,‘WeatherFile’, &
‘SEVERE’,‘> 0’,(RelHum> = 0.),‘< =
110’,(RelHum< = 110.))
To examine one call:
The variable DryBulb is set to its value.
In this case, it is coming from the Weather
File. The LowerBoundString is ‘>
- 70’ and the LowerBoundCondition is
(DryBulb>-70.) [this expression will yield true or false
depending…]
The LowerBounds (LowerBoundString,
LowerBoundCondition) are optional as are the
UpperBounds (UpperBoundString,
UpperBoundCondition). If we were only
testing one set of ranges, the call would look like:
Call RangeCheck(ErrorsFound,‘DryBulb
Temperature’,‘WeatherFile’,‘SEVERE’, &
UpperBoundString = ‘< 70’, UpperBoundCondition =
(DryBulb<70.))
ErrorLevel can be one of the usual Error levels:
WARNING – would be a simple warning message – the calling
routine might reset the value to be within bounds
SEVERE – a severe error. Usually the program would
terminate if this is in a “GetInput” routine. If during
execution, the calling program could reset the value but
RangeCheck contains too many string comparisons to be called
for an execution problem.
FATAL – not likely to be used. You want to provide a
context to the error and if really a fatal type error, you’d
like to execute the RangeCheck call and then terminate from
the calling program.
And the context for the message may be shown in the calling
routine by checking the value of ErrorsFound:
ErrFound = .false.
Call RangeCheck(ErrFound,‘This
field’,‘SEVERE’,‘< = 100’,(Value<100.))
IF (ErrFound) THEN
CALL ShowContinueError(‘Occurs in routine xyz’)
ErrorsFound = .true. ! for later termination
ENDIF
MakeUPPERCase[LINK]
This function can be used to make sure an upper case string
is being used. (Note this is not needed when using
“SameString”). Parameter 1 to the function is the string to
be upper cased:
USE InputProcessor, ONLY: MakeUPPERCase
UCString = MakeUPPERCase(‘lower
string’)
Input Services[LINK]
The module InputProcessor processes the input data files (IDFs). It also reads and parses the IDD file. The InputProcessor uses the definition lines in the IDD as directives on how to process each input object in the IDF. The InputProcessor also turns all alpha strings into all UPPER CASE. Currently, it does nothing else to those strings – so the number of blanks in a string must match what the calculational modules expect. The InputProcessor processes all numeric strings into single precision real numbers. Special characters, such as tabs, should not be included in the IDF.
The EnergyPlus module InputProcessor provides several routines - generically called the “get” routines – that enable the developer to readily access the data for a new module. These routines are made available by including a “USE InputProcessor” statement in the module or in the routine that will use the “get” routines. The GetFanInput subroutine in the example illustrates some of the uses of the “get” routines.
InputProcessor[LINK]
The following objects use public routines from the InputProcessor. To access these, the code has:
Use InputProcessor, ONLY: <routine1>, <routine2>
Where the <routine> is one or more of the following:
GetNumObjectsFound[LINK]
This function returns the number of objects in the input belonging to a particular class. In other terms, it returns the number of instances in the input of a particular component.
Example:
USE InputProcessor, ONLY: GetNumObjectsFound
NumVAVSys = GetNumObjectsFound(‘SINGLE DUCT:VAV:REHEAT’)
Here NumVAVSys will contain the number of single duct VAV terminal units in the input data file (IDF). SINGLE DUCT:VAV:REHEAT is the class name or keyword defining VAV terminal unit input on the IDD file.
GetObjectItem[LINK]
This subroutine is used to obtain the actual alphanumeric and numeric data for a particular object.
Example:
USE InputProcessor
INTEGER :: SysNum = 0 ! The Sys that you are currently loading input into
CHARACTER(Len = MaxNameLength) :: CurrentModuleObject
CHARACTER(Len = MaxNameLength), ALLOCATABLE, DIMENSION(:) :: Alphas
CHARACTER(Len = MaxNameLength), ALLOCATABLE, DIMENSION(:) :: cAlphaFields
CHARACTER(Len = MaxNameLength), ALLOCATABLE, DIMENSION(:) :: cNumericFields
REAL(r64), ALLOCATABLE, DIMENSION(:) :: Numbers
LOGICAL, ALLOCATABLE, DIMENSION(:) :: lAlphaBlanks
LOGICAL, ALLOCATABLE, DIMENSION(:) :: lNumericBlanks
INTEGER :: MaxNums = 0
INTEGER :: MaxAlphas = 0
INTEGER :: TotalArgs = 0
CALL GetObjectDefMaxArgs &
(‘AirTerminal:SingleDuct:VAV:Reheat’, TotalArgs, NumAlphas, NumNums)
MaxNums = MAX(MaxNums,NumNums)
MaxAlphas = MAX(MaxAlphas,NumAlphas)
!Start Loading the System Input
CurrentModuleObject = ‘AirTerminal:SingleDuct:VAV:Reheat’
DO SysIndex = 1, NumVAVSys
CALL GetObjectItem & (TRIM(CurrentModuleObject),SysIndex,Alphas,NumAlphas,Numbers,NumNums, &
IOSTAT,AlphaBlank = lAlphaBlanks,NumBlank = lNumericBlanks, &
AlphaFieldnames = cAlphaFields,NumericFieldNames = cNumericFields)
SysNum = SysIndex
— Check to make sure no duplicate names entered
Sys(SysNum)%SysName = Alphas(1)
Sys(SysNum)%SysType = TRIM(CurrentModuleObject)
Sys(SysNum)%SysType_Num = SingleDuctVAVReheat
END DO
Here GetObjectItem is called with inputs (‘AirTerminal:SingleDuct:VAV:Reheat’) – passed as CurrentModuleObject the class of object we want to input – and SysIndex – the index of the object on the input file. If SysIndex is 3, the call to GetObjectItem will get the data for the third VAV terminal unit on the input file. Output is returned in the remaining arguments. AlphArray contains in order all the alphanumeric data items for a single VAV terminal unit. NumArray contains all the numeric data items. NumAlphas is the number of alphanumeric items read; NumNums is the number of numeric data items read. IOSTAT is a status flag: -1 means there was an error; +1 means the input was OK. AlphArray and NumArray should be dimensioned to handle the largest expected input for the item – which in this case is set from a call to GetObjectDefMaxArgs. NumBlank is an optional argument to the routine – it can be used to determine if a numeric field was entered as “blank” rather than the filled value of 0.0. Likewise for NumFields and the others.
These are used to make the potential error messages from the GetInput routine correspond more closely to the IDD nomenclature, but look a bit funny in use:
IF (Sys(SysNum)%SchedPtr = = 0) THEN
CALL ShowSevereError( &
RoutineName//trim(CurrentModuleObject)//’ = “’// &
TRIM(Sys(SysNum)%SysName)//‘“, invalid schedule.’)
CALL ShowContinueError(TRIM(cAlphaFields(2))//’ = ’// &
TRIM(Alphas(2))//’ not found.’)
ErrorsFound = .true.
ENDIF
More information about standard error message formatting is contained in the Output Details and Examples document (for the user) and (for the developer) in this document section: Standard Message Format.
GetObjectDefMaxArgs[LINK]
Extensible input techniques[LINK]
While developers do their best to guess how many items are needed in an object, users will often want to extend that object with far more fields than were dreamed of. Using Allocatable arrays in Fortran usually makes this feasible, the special \extensible field makes it possible.
Example:
USE InputProcessor, ONLY: GetObjectDefMaxArgs
CHARACTER(len = MaxNameLength), ALLOCATABLE, DIMENSION(:) :: Alphas
REAL, ALLOCATABLE, DIMENSION(:) :: Numbers
! You supply the object word, routine returns numargs, numalpha, numnumeric
CALL GetObjectDefMaxArgs(‘DAYSCHEDULE:INTERVAL’,NumArgs,NumAlpha,NumNumeric)
ALLOCATE(Alphas(NumAlpha))
ALLOCATE(Numbers(NumNumeric))
! Then, usual get calls…
Thus, you can determine how many arguments that the IDD has defined as “maximum” for a given object.
GetObjectItemNum[LINK]
GetObjectItem, described above, requires the input file index of the desired object in order to get the object’s data. Sometimes this index may be unknown, but the name of the object is known. GetObjectItemNum returns the input file index given the class name and object name.
Example:
USE InputProcessor, ONLY: GetObjectItemNum
ListNum = GetObjectItemNum(‘CONTROLLER LIST’,ControllerListName)
In the example, ListNum will contain the input file index of the ‘CONTROLLER LIST’ whose name is contained in the string variable ControllerListName.
FindItemInList[LINK]
This function looks up a string in a similar list of items and returns the index of the item in the list, if found. It is case sensitive.
Example:
USE InputProcessor, ONLY: FindItemInList
SysNum = FindItemInList(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of names to be searched, and NumSys is the size of the list.
FindItem[LINK]
Case insensitive version of the FindItemInList.
Example:
USE InputProcessor, ONLY: FindItem
SysNum = FindItem(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of names to be searched, and NumSys is the size of the list.
FindItemInSortedList[LINK]
This function looks up a string in a sorted list of items and returns the index of the item in the list, if found. It is case sensitive.
Example:
USE InputProcessor, ONLY: FindItemInSortedList
SysNum = FindItemInSortedList(CompName,Sys%SysName,NumSys)
CompName is the input string, Sys%SysName is the list of names to be searched, and NumSys is the size of the list. See quick sort utility – most lists are NOT sorted in EnergyPlus.
SameString[LINK]
This function returns true if two strings are equal (case insensitively).
Example:
USE InputProcessor, ONLY: SameString
IF (SameString(InputRoughness,‘VeryRough’)) THEN
Material(MaterNum)%Roughness = VeryRough
ENDIF
VerifyName[LINK]
This subroutine checks that an object name is unique; that is, it hasn’t already been used for the same class of object and the name is not blank.
Example:
USE InputProcessor, ONLY: VerifyName
CALL VerifyName(AlphArray(1),Fan%FanName, &
FanNum-1,IsNotOK,IsBlank,‘FAN:SIMPLE:CONSTVOLUME Name’)
The first argument is the name to be checked, the second is the list of names to search, the third argument is the number of entries in the list, the 4th argument is set to TRUE if verification fails, the 5th argument is set to true if the name is blank, and the last argument is part of the error message written to the error file when verification fails.
RangeCheck[LINK]
The routine RangeCheck can be used to produce a reasonable error message to describe the situation in addition to setting the ErrorsFound variable to true. Errors found can then be checked in the calling routine and the program terminated if desired.
SUBROUTINE RangeCheck(ErrorsFound,WhatFieldString,WhatObjectString,ErrorLevel, &
LowerBoundString,LowerBoundCondition,UpperBoundString,UpperBoundCondition)
It can be used in a variety of places when the \minimum and \maximum fields will not work (e.g. different min/max dependent on some other field).
USE InputProcessor, ONLY: RangeCheck
ErrorsFound = .false.
CALL RangeCheck(ErrorsFound,‘DryBulb Temperature’,‘WeatherFile’, &
‘SEVERE’,‘> -70’,(Drybulb>-70.),‘< 70’,(DryBulb <70.))
CALL RangeCheck(ErrorsFound,‘DewPoint Temperature’,‘WeatherFile’, &
‘SEVERE’,‘> -70’,(Dewpoint>-70.),‘< 70’,(Dewpoint <70.))
CALL RangeCheck(ErrorsFound,‘Relative Humidity’,‘WeatherFile’, &
‘SEVERE’,‘> 0’,(RelHum> = 0.),‘< = 110’,(RelHum< = 110.))
To examine one call:
The variable DryBulb is set to its value. In this case, it is coming from the Weather File. The LowerBoundString is ‘> - 70’ and the LowerBoundCondition is (DryBulb>-70.) [this expression will yield true or false depending…]
The LowerBounds (LowerBoundString, LowerBoundCondition) are optional as are the UpperBounds (UpperBoundString, UpperBoundCondition). If we were only testing one set of ranges, the call would look like:
Call RangeCheck(ErrorsFound,‘DryBulb Temperature’,‘WeatherFile’,‘SEVERE’, &
UpperBoundString = ‘< 70’, UpperBoundCondition = (DryBulb<70.))
ErrorLevel can be one of the usual Error levels:
WARNING – would be a simple warning message – the calling routine might reset the value to be within bounds
SEVERE – a severe error. Usually the program would terminate if this is in a “GetInput” routine. If during execution, the calling program could reset the value but RangeCheck contains too many string comparisons to be called for an execution problem.
FATAL – not likely to be used. You want to provide a context to the error and if really a fatal type error, you’d like to execute the RangeCheck call and then terminate from the calling program.
And the context for the message may be shown in the calling routine by checking the value of ErrorsFound:
ErrFound = .false.
Call RangeCheck(ErrFound,‘This field’,‘SEVERE’,‘< = 100’,(Value<100.))
IF (ErrFound) THEN
CALL ShowContinueError(‘Occurs in routine xyz’)
ErrorsFound = .true. ! for later termination
ENDIF
MakeUPPERCase[LINK]
This function can be used to make sure an upper case string is being used. (Note this is not needed when using “SameString”). Parameter 1 to the function is the string to be upper cased:
USE InputProcessor, ONLY: MakeUPPERCase
UCString = MakeUPPERCase(‘lower string’)
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.