This section builds upon the discussion that appears in the
Input Output Reference under the heading “EnergyPlus
Economics.” The actual computation of monthly utility bills
is not difficult since it is mostly consists of multiplying
energy consumptions or demands by the price on a per unit
basis and adding different bill components. The
implementation in EnergyPlus becomes more complex since the
objects were crafted to allow a great deal of flexibility in
specifying a utility tariff while, at the same time, being as
simple as possible.
The following discussion on variables and hierarchies is
based on the text that appears in the Input Output
Reference.
Conceptual
Framework – Variables and Hierarchy[LINK]
To understand how to use the utility bill calculation
portion of EnergyPlus you first need to understand some
important concepts of variables and hierarchy. A variable,
for the purposes of this section, is simply a named holder of
a series of numbers. In most cases, the variable will be a
named holder of 12 numbers, one number for each monthly
utility bill. Here is a visualization of a variable called
Electric Energy Use:
Month
Electric Energy Use
January
12143
February
13454
March
14178
April
14876
May
15343
June
16172
July
16105
August
15762
September
14543
October
13987
November
13287
December
12403
If you have ever done any computer programming, you can
think of a variable as an array. Many of the names used in
the utility bill calculation portion of EnergyPlus are names
of variables. In the case of the UtilityCost:Charge objects,
the name of the object is also used as a name of a
variable.
In many of today’s utility rates, the charges for energy or
demand are broken into distribution and supply charges. To
allow for this, more than one charge may to be defined for a
particular category. The variables assigned to the same
category are added together.
The categories are combined in following hierarchy:
Category Hierarchy
Any charges included in the EnergyCharges category are
added together. The EnergyCharges, DemandCharges and
ServiceCharges are added together to form the Basis. The
Basis, Adjustments and Surcharges are added together to form
the Subtotal. The Subtotal and Taxes are added together to be
the Total. The total represents the total monthly charges on
that tariff for the energy source used. The combining of
categories together is performed automatically unless the user
specifies the UtilityCost:Computation. In addition, each
category, which is also a variable, may be used as a source.
For example, a tax that is 5% of the subtotal would be shown
as:
UtilityCost:Charge:Simple,
TaxOfFivePercent, ! Charge Variable Name
TariffExample1, ! Tariff Name
Subtotal, ! Source Variable
Annual, ! Season
Taxes, ! Category Variable Name
0.05; ! Cost Per Unit Value (or Variable)
As you can see, the UtilityCost:Charge:Simple
and UtilityCost:Charge:Block
objects do most of the “work” of computing the annual energy
cost. The benefit of using this categorization is that totals
of each category are shown in the output reports and it
organizes the charges in the monthly calculations in a logical
way that fits almost all tariffs. If no categorization is
desired, theoretically, all charges could be assigned to the
Total category. The categories themselves are simply variable
names. Charges may also be assigned to the “NotIncluded”
category if the result of the charge is used as an
intermediate calculation and should not be included in the
Total.
The user has the option of two different ways to determine
the order of computation. If an UtilityCost:Computation
object is specified for the tariff, the sequence specified in
that object is used for computing the various variables. If no
UtilityCost:Computation
object is specified, a sequence of computational steps is
automatically derived and shown as part of the report. The
routine that creates this automatic sequence of computation
steps is called CreateDefaultComputation as part of the
EconomicTariff module.
The order in which the computation should be made is
complicated by the fact that the objects can each have
variables that are inputs and others that are outputs. Since
any of the variables can be used as inputs, we must ensure
that they are computed prior to being used. In other words,
because the objects allow a great deal of flexibility, there
is no simple default order that the computations should be
made.
Luckily there are known algorithms for sorting though these
types of interdependencies. In fact, the method that
spreadsheets use for sorting through the dependencies of cell
formulas referencing other cells with formula is very
similar. In addition, linkers (used as part of the computer
language compiling process) face similar issues of sorting
through dependences. Figuring out the optimal path in a
complex project represented by a PERT Chart also uses a
similar algorithm.
Generically, dependency problems are usually characterized
as Directed Acycle Graphs (DAGs). A DAG shows the individual
formulas as circles and uses arrows between the circles to
show which formula is dependent on which other formulas. One
of the simplest explanations can be seen at the following
website:
(Click on lecture 14 “Critical Path”).
The lecture and site was created by Alison Cawsey,
Department of Computing and Electrical Engineering,
Heriot-Watt University Edinburgh EH14 4AS, UK. The specific
algorithm that was used in EnergyPlus is described at this
site and is quoted below:
Calculate, for each node, the in-degree of that node (ie,
now many edges end up there). Store these in array D.
Repeat:
– Remove (output) node such that D[n] = 0.
– Decrement D[x] for all nodes x that are neighbors of n
(edge from n to x).
Of course in this case “node” has nothing to do with
EnergyPlus nodes but is just describing one of the formulas in
a DAG. This is just one of several different methods to solve
a DAG. The general method for solving a DAG is called a
topological sort. The algorithm used in EnergyPlus is one of
the simplest methods available and is appropriate given the
number of dependencies. More efficient algorithms are known
but are probably only appropriate for much larger number of
dependencies.
One important note, if after the algorithm is exercised,
and some of the formulas still have a count on the number of
dependencies, it must be the result of a circular dependency
and an error condition is flagged in the ERR file.
The objects have specific variables that are used as inputs
and outputs, and thus the outputs are dependent on the inputs,
are shown in the following table:
Object Variables Inputs and
Outputs
Object
Outputs
Inputs
Qualify
Name
Source
Threshold
Charge:Simple
Name
Source
Category
Cost Per Unit
Charge:Block
Name
Source
Category
Block Size Multiplier
Remaining
Block Size
Block Cost
Ratchet
Name
Baseline
Adjustment
Multiplier
Offset
In addition, the hierarchy shown in the first diagram in
this section also represents dependencies that are included
when determining the order of computation.
The resulting order of computation is shown at the bottom
of the economics report.
Once the order that the formulas should be computed is
known, the actual evaluation of the formulas is based on a
simple Last In First Out (LIFO) stack. This is a common
method to compute expressions where values are stored on the
stack and operands work off of the top of the stack.
Tariff Computation[LINK]
The EnergyPlus economic (Utility Costs) objects related to computing utility bills include:
UtilityCost:Tariff
UtilityCost:Qualify
UtilityCost:Charge:Simple
UtilityCost:Charge:Block
UtilityCost:Ratchet
UtilityCost:Variable
UtilityCost:Computation
This section builds upon the discussion that appears in the Input Output Reference under the heading “EnergyPlus Economics.” The actual computation of monthly utility bills is not difficult since it is mostly consists of multiplying energy consumptions or demands by the price on a per unit basis and adding different bill components. The implementation in EnergyPlus becomes more complex since the objects were crafted to allow a great deal of flexibility in specifying a utility tariff while, at the same time, being as simple as possible.
The following discussion on variables and hierarchies is based on the text that appears in the Input Output Reference.
Conceptual Framework – Variables and Hierarchy[LINK]
To understand how to use the utility bill calculation portion of EnergyPlus you first need to understand some important concepts of variables and hierarchy. A variable, for the purposes of this section, is simply a named holder of a series of numbers. In most cases, the variable will be a named holder of 12 numbers, one number for each monthly utility bill. Here is a visualization of a variable called Electric Energy Use:
If you have ever done any computer programming, you can think of a variable as an array. Many of the names used in the utility bill calculation portion of EnergyPlus are names of variables. In the case of the UtilityCost:Charge objects, the name of the object is also used as a name of a variable.
In many of today’s utility rates, the charges for energy or demand are broken into distribution and supply charges. To allow for this, more than one charge may to be defined for a particular category. The variables assigned to the same category are added together.
The categories are combined in following hierarchy:
Any charges included in the EnergyCharges category are added together. The EnergyCharges, DemandCharges and ServiceCharges are added together to form the Basis. The Basis, Adjustments and Surcharges are added together to form the Subtotal. The Subtotal and Taxes are added together to be the Total. The total represents the total monthly charges on that tariff for the energy source used. The combining of categories together is performed automatically unless the user specifies the UtilityCost:Computation. In addition, each category, which is also a variable, may be used as a source. For example, a tax that is 5% of the subtotal would be shown as:
As you can see, the UtilityCost:Charge:Simple and UtilityCost:Charge:Block objects do most of the “work” of computing the annual energy cost. The benefit of using this categorization is that totals of each category are shown in the output reports and it organizes the charges in the monthly calculations in a logical way that fits almost all tariffs. If no categorization is desired, theoretically, all charges could be assigned to the Total category. The categories themselves are simply variable names. Charges may also be assigned to the “NotIncluded” category if the result of the charge is used as an intermediate calculation and should not be included in the Total.
The objects that create variables are:
UtilityCost:Qualify
UtilityCost:Charge:Simple
UtilityCost:Charge:Block
UtilityCost:Ratchet
UtilityCost:Variable
Default Order of Computation[LINK]
The user has the option of two different ways to determine the order of computation. If an UtilityCost:Computation object is specified for the tariff, the sequence specified in that object is used for computing the various variables. If no UtilityCost:Computation object is specified, a sequence of computational steps is automatically derived and shown as part of the report. The routine that creates this automatic sequence of computation steps is called CreateDefaultComputation as part of the EconomicTariff module.
The order in which the computation should be made is complicated by the fact that the objects can each have variables that are inputs and others that are outputs. Since any of the variables can be used as inputs, we must ensure that they are computed prior to being used. In other words, because the objects allow a great deal of flexibility, there is no simple default order that the computations should be made.
Luckily there are known algorithms for sorting though these types of interdependencies. In fact, the method that spreadsheets use for sorting through the dependencies of cell formulas referencing other cells with formula is very similar. In addition, linkers (used as part of the computer language compiling process) face similar issues of sorting through dependences. Figuring out the optimal path in a complex project represented by a PERT Chart also uses a similar algorithm.
Generically, dependency problems are usually characterized as Directed Acycle Graphs (DAGs). A DAG shows the individual formulas as circles and uses arrows between the circles to show which formula is dependent on which other formulas. One of the simplest explanations can be seen at the following website:
(Click on lecture 14 “Critical Path”).
The lecture and site was created by Alison Cawsey, Department of Computing and Electrical Engineering, Heriot-Watt University Edinburgh EH14 4AS, UK. The specific algorithm that was used in EnergyPlus is described at this site and is quoted below:
Calculate, for each node, the in-degree of that node (ie, now many edges end up there). Store these in array D.
Repeat:
– Remove (output) node such that D[n] = 0.
– Decrement D[x] for all nodes x that are neighbors of n (edge from n to x).
Of course in this case “node” has nothing to do with EnergyPlus nodes but is just describing one of the formulas in a DAG. This is just one of several different methods to solve a DAG. The general method for solving a DAG is called a topological sort. The algorithm used in EnergyPlus is one of the simplest methods available and is appropriate given the number of dependencies. More efficient algorithms are known but are probably only appropriate for much larger number of dependencies.
One important note, if after the algorithm is exercised, and some of the formulas still have a count on the number of dependencies, it must be the result of a circular dependency and an error condition is flagged in the ERR file.
The objects have specific variables that are used as inputs and outputs, and thus the outputs are dependent on the inputs, are shown in the following table:
Object Variables Inputs and Outputs
In addition, the hierarchy shown in the first diagram in this section also represents dependencies that are included when determining the order of computation.
The resulting order of computation is shown at the bottom of the economics report.
Computation Steps[LINK]
Once the order that the formulas should be computed is known, the actual evaluation of the formulas is based on a simple Last In First Out (LIFO) stack. This is a common method to compute expressions where values are stored on the stack and operands work off of the top of the stack.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.