BLASTTranslator[LINK]
The BLAST Translator will produce an IDF file from an
existing BLAST Input File (usually called
<something>.bin. For anyone that is unfamiliar, BLAST
stands for the Building
Loads Analysis and Systems Thermodynamics computer program.
Documentation is included here though the BLAST Translator is
no longer included with the EnergyPlus Installation - it is
available as a special download for those who need it.
A special batch file (RunXLate.bat) can be
used to run the translation program. Similar to running
EnergyPlus (see above), you run this batch file:
RunXLate <blastinputfile>
Where <blastinputfile> is the part of the file name
without extension. The program produces a .idf file of the
same name.
The BLASTTranslator uses an “Energy+.ini” file for some
parameters. For example:
[program]
dir =
ver =
surf = group
[weather]
dir =
The above BLASTTranslator ini file sets the “version” of
EnergyPlus to the current version and has the “surf” parameter
set to “group”. This BLASTTranslator run will produce an
EnergyPlus input file for the current release version format
and will name surfaces by Zone
and Class (e.g. ZN001:Wall001). The alternative “Consecutive”
will number surfaces in sequence.
To download the latest version of the BLASTTranslator, go
to energyplus.net/extras
and look for the Additional Release Components section.
BLASTTranslator[LINK]
The BLAST Translator will produce an IDF file from an existing BLAST Input File (usually called <something>.bin. For anyone that is unfamiliar, BLAST stands for the Building Loads Analysis and Systems Thermodynamics computer program. Documentation is included here though the BLAST Translator is no longer included with the EnergyPlus Installation - it is available as a special download for those who need it.
A special batch file (RunXLate.bat) can be used to run the translation program. Similar to running EnergyPlus (see above), you run this batch file:
RunXLate <blastinputfile>
Where <blastinputfile> is the part of the file name without extension. The program produces a .idf file of the same name.
The BLASTTranslator uses an “Energy+.ini” file for some parameters. For example:
The above BLASTTranslator ini file sets the “version” of EnergyPlus to the current version and has the “surf” parameter set to “group”. This BLASTTranslator run will produce an EnergyPlus input file for the current release version format and will name surfaces by Zone and Class (e.g. ZN001:Wall001). The alternative “Consecutive” will number surfaces in sequence.
To download the latest version of the BLASTTranslator, go to energyplus.net/extras and look for the Additional Release Components section.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.