Table of Contents: Output Details and Examples — EnergyPlus 9.1
Table of Contents
All 9.1 Docs
|
Docs Home
|
EPx Home
Introduction
Output Files
Output File List
eplusout.audit
eplusout.bnd
eplusout.dbg
eplusout.dxf
eplusout.edd
eplusout.eio
Simulation Parameters
Version
Timestep
SimulationControl
Building
Inside Convection Algorithm
Outside Convection Algorithm
Solution Algorithm
Sky Radiance Distribution
Site Atmospheric Variation
Shadowing/Sun Position Calculations
AirflowNetwork Model:Control
AirflowNetwork Model:Wind Direction
AirflowNetwork Model:Wind Pressure Coefficients
Zone Volume Capacitance Multiplier
Climate Group Outputs
Climate Group – Simple Outputs
Location
Site Water Mains Temperature
Weather Station
Site Atmospheric Variation
Ground Temperatures and Ground Reflectances
Ground Temperatures
Ground Reflectance
Snow Ground Reflectance Modifiers
Snow Ground Reflectance
Snow Ground Reflectance for Daylighting
Climate Group – Not so Simple Outputs
Environment Line
Design Day Misc Line
Special Day Line
Daylight Saving Line
Zone Outputs
Zone Summary
Zone Information
Internal Gains Outputs
Zone Internal Gains
People Gains
Lights Gains
Equipment (Electric, Gas, Steam, Hot Water) Gains
Other Equipment Gains
Outdoor Controlled Baseboard Heat
Simple Airflow Outputs
Infiltration, Ventilation, Mixing, Cross Mixing Statistics
Infiltration
Ventilation
Mixing
Cross Mixing
RefrigerationDoor Mixing
Shading Summary
Surface Details Report
Calculating with Surface Details Report
Surface Convection Parameters
OtherSideCoefficient Outputs
Construction Element Outputs
Opaque Constructions
Window Constructions
Material
:
WindowGlass
Material:WindowBlind
ThermoChromic Windows
Complex Fenestration
HAMT Cell Data
Sizing Information
Zone Sizing Information
System Sizing Information
Plant Coincident Sizing Algorithm
Component Sizing Information
Heating/Cooling Coil Capacity Information
Refrigerated Case and WalkIn Output
View Factor Info
View Factor Details
DX Coil Outputs
DX Cooling Coil Outputs
DX Cooling Coil Outputs for ASHRAE 127 Standard Ratings
DX Heating Coil Outputs
Chiller Outputs
Lookup Table Outputs
Warmup Days Line
Warmup Convergence Outputs
Warmup Convergence Information
Summary Warmup Convergence Information
Detailed Warmup Convergence Information
eplusout.end
eplusout.epmidf
eplusout.epmdet
eplusout.err
eplusout.eso
eplusout.mtd
eplusout.mtr
eplusout.rdd
Normal Output Variables – regular format
Normal Output Variables – regular format – sorted by name
Normal Output Variables – IDF format
Advanced Output Variables
eplusout.mdd
Meter Variables – regular format
Meter Variables – regular format – sorted by name
Meter Variables – IDF format
Meter Naming Convention
eplusout.shd
eplusout.sln
eplusout.sql
List of Available SQLite Tables
Report Data
One time (EIO) File Data
Miscellaneous Tables
How to Access the SQLite Data
eplusssz.<ext>
epluszsz.<ext>
eplusout.<ext>
eplusmtr.<ext>
eplusmap.<ext>
eplusout.dfs
eplusscreen.csv
eplustbl.<ext>
Output:Table:SummaryReports
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Equipment Summary
Envelope Summary
Surface Shadowing Summary
Shading Summary
Lighting Summary
HVAC Sizing Summary
System Summary
Component Sizing Summary
Outdoor Air Summary
Climatic Data Summary
Object Count Summary
Component Cost Economics Summary
LEED Summary
Initialization Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
Component Loads Summary
Output:Table:TimeBins
Output:Table:Monthly
UtilityCost:Tariff
Construction Cost Estimate Summary
XML Tabular Output
readvars.rvaudit
eplusout.svg
eplusout.sci
eplusout.wrl
Delight output files
eplusout.delightin
eplusout.delightout
Example Input Files
Data Sets
Simple List Data Sets
AirCooledChillers.idf
ASHRAE_2005_HOF_Materials.idf
Boilers.idf
California_Title_24-2008.idf
Chillers.idf
CompositeWallConstructions.idf
DXCoolingCoil.idf
ElectricGenerators.idf
Electricity USA Environmental Impact Factors.idf
ElectronicEnthalpyEconomizerCurves.idf
Form of the Electronic Enthalpy Curve Equation:
Example Curve A:
Exhaust Fired Chiller.idf
Fossil Fuel Environmental Impact Factors.idf
FluidPropertiesRefData.idf
GlycolPropertiesRefData.idf
GHLERefData.idf
MoistureMaterials.idf
PerfCurves.idf
PrecipitationSchedulesUSA.idf
RefrigerationCasesDataSet.idf
RefrigerationCompressorCurves.idf
RooftopPackagedHeatPump.idf
SandiaPVData.idf
Schedules.idf
SolarCollectors.idf
StandardReports.idf
SurfaceColorSchemes.idf
USHolidays-DST.idf
Window5DataFile.dat
WindowBlindMaterials.idf
WindowConstructs.idf
WindowGasMaterials.idf
WindowGlassMaterials.idf
WindowShadeMaterials.idf
WindowScreenMaterials.idf
Macro Data Sets
Locations-DesignDays.xls
SandiaPVData.idf
SolarCollectors.idf
UtilityTariffObjects.imf
Documentation content copyright © 1996-2020 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.