EnergyPlus File
Extensions[LINK]
This section will present a list of common EnergyPlus file
extensions and what they mean. This will help you after the
EP-Launch program finishes.
The following files are input to the EnergyPlus
program.
The input data dictionary (IDD) is an ASCII (text)
file containing a list of all possible EnergyPlus objects and
a specification of the data each object requires. This file is
analogous to the DOE-2 keyword file. The Guide for
Interface Developers contains a full description of the
input data dictionary.
The input data file (IDF) is an ASCII file
containing the data describing the building and HVAC system to
be simulated. Many example files are installed as part of the
EnergyPlus installation. Additionally, a spreadsheet file
“ExampleFiles.xls” contains columnar descriptions of each
file’s features.
The input macro file (IMF) is an ascii file
containing the data describing the building and HVAC system to
be simulated and will have some contents of “macro” commands.
The Auxiliary programs document describes use of the macro
commands and the program that processes them – EP-Macro.
Many example files are installed as part of the EnergyPlus
installation.
This is the EnergyPlus initialization file. It is an
optional ascii input file that allows the user to specify the
path for the directory containing Energy+.idd. This file,
using the actual directories of the install, will be created
during the install. Unless you change where the EnergyPlus.exe
file resides, you will not need to change this file.
The EnergyPlus weather file is an ascii file
containing the hourly or sub-hourly weather data needed by the
simulation program. The data format is described in detail in
the Auxiliary Programs Document. It is also described
succinctly in the Input Output Reference document.
Primary Output Files[LINK]
The following output files are the most important for
beginning users. Then, there is the section on “other output”
files. And, more information about output files (complete
list) is shown in the Output
Details and Examples Document.
A text file containing the error messages issued by
EnergyPlus. This is the first output that should be
examined after a simulation.Error messages may be
issued by EnergyPlus during its input phase or during the
simulation. There are three levels of error severity:
fatal, severe, and warning as well
as simple “information” lines. A fatal error causes
the program to terminate immediately. The following table
illustrates the necessary actions.
Error Message Levels – Required Actions
| Error Level |
Action |
| Information, shown as
********* |
Informative, usually a follow-on
to one of the others. No action required. |
| ** ~\~~ ** |
This is a continuation of a
previous message. String all the words/sentences together to
form the complete message. |
| Warning |
Take note. Fix as
applicable. |
| Severe |
Should Fix |
| Fatal |
Program will abort, Must
Fix |
When run normally, EP-Launch and EnergyPlus automatically
creates post-processed standard output (eso) and meter output
(mtr) files into columnar csv (comma separated variable)
files. These files are ready to be read by spreadsheet
programs (such as ExcelTM).
Several of the report options produce html files that can
be read in standard Web browsers. These are very powerful,
information packed files. Though wary of information
overload, the easiest way to see “everything” is to enter the
following in your input file:
OutputControl:Table,
HTML; !- ColumnSeparator
Output:Table:SummaryReports,
All Summary;
Note that you can also get this file in other formats (the
OutputControl:Table option).
Other Output Files[LINK]
This is an text file which echoes the IDD and IDF files,
flagging syntax errors in either file. Note that both
err and audit will show most of the error
messages caused by input syntax errors; however only
err will show errors issued during the actual
simulation. The audit can be used when you need to
see the context of the error message to fully ascertain the
cause. The audit file also contains potentially extra
information that may be useful from the input scan.
The EnergyPlus Standard Output (ESO) is a text
file containing the time varying simulation output. The format
of the file is discussed in the Guide for Interface
Developers and the InputOutputReference. The
contents of the file are controlled by Output:Variable
commands in the IDF file. Although the ESO is a text file, it
is not easily interpretable by a human. Usually postprocessing
will be done on this file in order to put it in a format that
can be read by a spreadsheet; however a quick visual
inspection of the file does show whether the expected
variables are output at the desired time step.
The EnergyPlus Meter Output (MTR) is a text file
containing the time varying simulation output. The format of
the file is similar to the ESO file. As described in a later
section of this document (see Energy Meters), meters are a
powerful reporting tool in EnergyPlus. Values are grouped onto
logical meters and can be viewed the same way that the ESO
variables are used. The contents of the file are controlled by
Output:Meter
commands in the IDF file. Although the MTR is a text file, it
is not easily interpretable by a human. Usually postprocessing
will be done on this file in order to put it in a format that
can be read by a spreadsheet; however a quick visual
inspection of the file does show whether the expected
variables are output at the desired time step.
This file contains all the details (i.e., which report
variables are on a meter and, conversely, what meters contain)
about meters.
The EnergyPlus Invariant Output (EIO) is a text
file containing output that does not vary with time. For
instance, location information (latitude, longitude, time
zone, altitude) appears on this file.
The Report (variable) Data Dictionary (RDD) is a
text file listing those variables available for reporting (on
the ESO) for this particular simulation. Which variables are
available for output depends on the actual simulation problem
described in the IDF. The Report (meter) Data
Dictionary (MDD) is a text file listing those variables
available for reporting (on the MTR) for this particular
simulation. Which meters are available for output depends on
the actual simulation problem described in the IDF. A
simulation with no chiller does not permit the output of any
chiller report variables. The user may need to examine the RDD
or MDD to find out which report variables are available in a
particular simulation. The RDD and MDD are written only if the
following is included in the IDF file.
Output:Reports, VariableDictionary;
A variant produces the same files in a IDF “ready”
format.
Output:Reports, VariableDictionary, IDF;
This is a file in AutoCadTM DXF format showing
all the surfaces defined in the IDF file. It provides a means
of viewing the building geometry. The DXF file from EnergyPlus
highlights different building elements (shading, walls,
subsurfaces) in differing colors. A number of programs can
read and display DXF files. Output of this file is triggered
by
Output:Reports, Surfaces, DXF;
in the IDF.
EnergyPlus File Extensions[LINK]
This section will present a list of common EnergyPlus file extensions and what they mean. This will help you after the EP-Launch program finishes.
Input Files[LINK]
The following files are input to the EnergyPlus program.
IDD[LINK]
The input data dictionary (IDD) is an ASCII (text) file containing a list of all possible EnergyPlus objects and a specification of the data each object requires. This file is analogous to the DOE-2 keyword file. The Guide for Interface Developers contains a full description of the input data dictionary.
idf[LINK]
The input data file (IDF) is an ASCII file containing the data describing the building and HVAC system to be simulated. Many example files are installed as part of the EnergyPlus installation. Additionally, a spreadsheet file “ExampleFiles.xls” contains columnar descriptions of each file’s features.
imf[LINK]
The input macro file (IMF) is an ascii file containing the data describing the building and HVAC system to be simulated and will have some contents of “macro” commands. The Auxiliary programs document describes use of the macro commands and the program that processes them – EP-Macro. Many example files are installed as part of the EnergyPlus installation.
ini[LINK]
This is the EnergyPlus initialization file. It is an optional ascii input file that allows the user to specify the path for the directory containing Energy+.idd. This file, using the actual directories of the install, will be created during the install. Unless you change where the EnergyPlus.exe file resides, you will not need to change this file.
epw[LINK]
The EnergyPlus weather file is an ascii file containing the hourly or sub-hourly weather data needed by the simulation program. The data format is described in detail in the Auxiliary Programs Document. It is also described succinctly in the Input Output Reference document.
Primary Output Files[LINK]
The following output files are the most important for beginning users. Then, there is the section on “other output” files. And, more information about output files (complete list) is shown in the Output Details and Examples Document.
err[LINK]
A text file containing the error messages issued by EnergyPlus. This is the first output that should be examined after a simulation.Error messages may be issued by EnergyPlus during its input phase or during the simulation. There are three levels of error severity: fatal, severe, and warning as well as simple “information” lines. A fatal error causes the program to terminate immediately. The following table illustrates the necessary actions.
csv[LINK]
When run normally, EP-Launch and EnergyPlus automatically creates post-processed standard output (eso) and meter output (mtr) files into columnar csv (comma separated variable) files. These files are ready to be read by spreadsheet programs (such as ExcelTM).
htm/html[LINK]
Several of the report options produce html files that can be read in standard Web browsers. These are very powerful, information packed files. Though wary of information overload, the easiest way to see “everything” is to enter the following in your input file:
Note that you can also get this file in other formats (the OutputControl:Table option).
Other Output Files[LINK]
audit[LINK]
This is an text file which echoes the IDD and IDF files, flagging syntax errors in either file. Note that both err and audit will show most of the error messages caused by input syntax errors; however only err will show errors issued during the actual simulation. The audit can be used when you need to see the context of the error message to fully ascertain the cause. The audit file also contains potentially extra information that may be useful from the input scan.
eso[LINK]
The EnergyPlus Standard Output (ESO) is a text file containing the time varying simulation output. The format of the file is discussed in the Guide for Interface Developers and the InputOutputReference. The contents of the file are controlled by Output:Variable commands in the IDF file. Although the ESO is a text file, it is not easily interpretable by a human. Usually postprocessing will be done on this file in order to put it in a format that can be read by a spreadsheet; however a quick visual inspection of the file does show whether the expected variables are output at the desired time step.
mtr[LINK]
The EnergyPlus Meter Output (MTR) is a text file containing the time varying simulation output. The format of the file is similar to the ESO file. As described in a later section of this document (see Energy Meters), meters are a powerful reporting tool in EnergyPlus. Values are grouped onto logical meters and can be viewed the same way that the ESO variables are used. The contents of the file are controlled by Output:Meter commands in the IDF file. Although the MTR is a text file, it is not easily interpretable by a human. Usually postprocessing will be done on this file in order to put it in a format that can be read by a spreadsheet; however a quick visual inspection of the file does show whether the expected variables are output at the desired time step.
mtd[LINK]
This file contains all the details (i.e., which report variables are on a meter and, conversely, what meters contain) about meters.
eio[LINK]
The EnergyPlus Invariant Output (EIO) is a text file containing output that does not vary with time. For instance, location information (latitude, longitude, time zone, altitude) appears on this file.
rdd[LINK]
mdd[LINK]
The Report (variable) Data Dictionary (RDD) is a text file listing those variables available for reporting (on the ESO) for this particular simulation. Which variables are available for output depends on the actual simulation problem described in the IDF. The Report (meter) Data Dictionary (MDD) is a text file listing those variables available for reporting (on the MTR) for this particular simulation. Which meters are available for output depends on the actual simulation problem described in the IDF. A simulation with no chiller does not permit the output of any chiller report variables. The user may need to examine the RDD or MDD to find out which report variables are available in a particular simulation. The RDD and MDD are written only if the following is included in the IDF file.
A variant produces the same files in a IDF “ready” format.
dxf[LINK]
This is a file in AutoCadTM DXF format showing all the surfaces defined in the IDF file. It provides a means of viewing the building geometry. The DXF file from EnergyPlus highlights different building elements (shading, walls, subsurfaces) in differing colors. A number of programs can read and display DXF files. Output of this file is triggered by
in the IDF.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.