eplusout.audit |
Echo of input, includes both IDD echo and IDF echo – may have errors shown in context with IDD or IDF statements |
< filename > .audit (without echoing IDD unless errors in IDD). |
eplusout.bnd |
This file contains details about the nodes and branches. Useful in determining if all your nodes are connected correctly. May be used to diagram the network/ nodes of the HVAC system. |
< filename > .bnd |
eplusout.dbg |
From Debug Output object – may be useful to support to help track down problems |
< filename > .dbg |
eplusout.dxf |
DXF (from Output:Surfaces:Drawing,DXF;) |
< filename > .dxf |
eplusout.edd |
Descriptive output from the EMS portion |
< filename > .edd |
eplusout.eio |
Contains several standard and optional “report” elements. CSV format – may be read directly into spreadsheet program for better formatting. |
< filename > .eio |
eplusout.end |
A one line summary of success or failure (useful for Interface programs) |
Not saved in the standard EPL-Run script file. |
eplusout.epmidf |
Output from EPMacro program – contains the idf created from the input imf file |
< filename > .epmidf |
eplusout.epmdet |
Output from EPMacro program – the audit/details of the EPMacro processing |
< filename > .epmdet |
eplusout.err |
Error file – contains very important information from running the program. |
< filename > .err |
eplusout.eso |
Standard Output File (contains results from both Output:Variable and Output:Meter objects). |
< filename > .eso |
eplusout.log |
Log of items that appear in the command file output from the run. |
< filename > .log |
eplusout.mdd |
Meter names that are applicable for reporting in the current simulation. |
< filename > .mdd |
eplusout.mtd |
Meter details report – what variables are on what meters and vice versa. This shows the meters on which the Zone: Lights Electric Energy appear as well as the contents of the Electricity:Facility meter. |
< filename > .mtd |
eplusout.mtr |
Similar to .eso but only has Output:Meter outputs. |
< filename > .mtr |
eplusout.rdd |
Variable names that are applicable for reporting in the current simulation. |
< filename > .rdd |
eplusout.shd |
Surface shadowing combinations report |
< filename > .shd |
eplusout.sln |
Similar to DXF output but less structured. Results of Output:Reports,Surface, Lines object. |
< filename > .sln |
eplusout.sql |
Mirrors the data in the .eso and .mtr files but is in SQLite format (for viewing with SQLite tools). |
< filename > .sql |
eplusssz. < ext > |
Results from the Sizing:System object. This file is “spreadsheet” ready. Different extensions (csv, tab, and txt) denote different “separators” in the file. |
< filename > Ssz. < ext > |
epluszsz. < ext > |
Results from the Sizing:Zone object. This file is “spreadsheet” ready. Different extensions (csv, tab, and txt) denote different “separators” in the file. |
< filename > Zsz. < ext > |
eplusmap. < ext > |
Daylighting intensity “map” output. Different extensions (csv, tab, and txt) denote different “separators” in the file. |
< filename > Map. < ext > |
eplusout.dfs |
This file contains the hourly pre-calculated daylight factors for exterior windows of a daylight zone. |
< filename > DFS.csv |
eplusscreen.csv |
Window screen transmittance (direct and reflected) “map” output. |
< filename > Screen.csv |
eplustbl. < ext > |
Results of tabular and economics requests. Different extensions (csv, tab, and txt) denote different “separators” in the file. |
< filename > Table. < ext > |
eplusout.svg |
Results from the HVAC-Diagram application. SVG is a Scalable Vector Graphics file for which several viewers can be found. |
< filename > .svg |
eplusout.sci |
File of cost information |
< filename > .sci |
eplusout.delightin |
File produced during DElight simulations – descriptive of EnergyPlus inputs into DElight inputs. |
< filename > delight.in |
eplusout.delightout |
File produced during DElight simulations – basic results from DElight simulation. |
< filename > delight.out |
eplusout.wrl |
VRML output from (Output:Reports, Surfaces, VRML) |
< filename > .wrl |
Output File List[LINK]
Following are the native file names that are output from EnergyPlus; native – directly out of EnergyPlus. Usually you will not see these file names as batch files and interfaces will change them to be <file name>.<ext> or in some instances <file name><qualifier>.<ext>. Usually the extension is the important piece and is described in the following table.
In addition to the basic output files from EnergyPlus there are three standard “hybrid” output files. These are called “hybrid” because they are a result of post-processing after EnergyPlus has completed. Note that if there is an error during processing, these will not normally be “complete”.
Now, each file will be described in more detail with some examples of use.
Documentation content copyright © 1996-2016 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.