The choice of variables to output is really up to the
developer. Since variables don’t appear on the output file
unless requested by the user in the IDF input file, it is
better to “SetUp” too many rather than too few. For an HVAC
component one should generally output the heating and cooling
outputs of the component both in terms of energy and power.
Energy is always output in Joules, power in Watts. If there is
humidification or dehumidification both total and sensible
cooling should be reported. Any electricity or fuel consumed
by a component should be reported out, again both in terms of
energy (Joules) and power (Watts). For HVAC components in most
cases reporting inlet and outlet temperatures and humidities
is unnecessary since these quantities can be obtained from the
system node outputs.
The names for output variables need to be selected
carefully to maintain a high level of consistency and clarity.
Well-chosen names help users quickly understand the meaning of
a specific output.
The following general guidelines are to be followed when
choosing names for new output variables:
Output variable names shall be written in title case where
every major word is capitalized (exceptions: “a”, “the”,
“for”, etc.) with spaces separating words.
Output variable names shall be written using natural
language terminology but should be relatively concise. The
language is American English.
Although they should be avoided where practical, acronyms
(and symbols) are acceptable where their use is commonplace
and contributes to conciseness in identifying a complex
engineering concept. Examples of acceptable acronyms for
output variable names are listed in the table below.
Abbreviations should not be used and the words spelled out
completely (except for Units).
Where practical, reuse existing names for output variables
across different models for similar components. For example, a
new model for a zone baseboard heater should reuse the
existing names for output variables already in use for other
baseboard models rather than use new names that distinguish
the kind of baseboard model that the output is associated
with. The user-defined name of the component should allow the
user to know the association without the basic name of the
output variable reflecting that association. This has the
advantage of reducing the total number of output variable
names and making it simpler for users.
Engineering terminology should generally be consistent
with that used in ASHRAE handbooks and literature (American
Society of Heating, Refrigeration and Air-Conditioning
Engineers, Inc., Atlanta, CA, USA)
Output variable names shall have no punctuation or special
characters. The names are expected to contain many adjectives
adjacent to each other and no hyphens or commas are needed to
clarify.
Output variable names shall always be less than 100
characters long.
An output variable name should be constructed from up to
six separate name elements. The following diagram shows the
elements and the order that they are to be used in the name.
The first three are each somewhat optional and are used as
needed to identify the type of engineering model, object, or
device being reported on. The last three are nearly always
needed. Units are always needed (as described below.
Output Variable Classification
Elements
Model Classification. This name element is
used to identify the specific type of modeling being
conducted. When used, it will form the first part of the name.
This name element is often not needed, such as when the output
is for a more or less usual aspect of buildings and HVAC
system models. This is typically used to identify outputs that
are associated with an alternative, usually more advanced,
model, such as AirflowNetwork (AFN) or Conduction Finite
Difference (CondFD). Although modeling domains such as Building,
HVAC, or Internal Loads are usually obvious and not needed
here, this classification can be useful for non-obvious
sub-domains such as Environmental Impact, Refrigeration, or
Daylighting.
Spatial Classification. This name element
is used to identify spatial or topological location of the
thing being reported on. It is generally used to identify
which part of the building or system is being referred to by
the output. For parts of the building, classifications such as
“Zone”
and “Surface” are the most common. For a model such as
Refrigeration this classification may identify specific parts
of the system, such as “Secondary Loop.” There is often no
spatial or topological aspect needed and in that case this
name element can be omitted.
Type of Component. This name element is
used to identify the type of device or phenomena being modeled
and reported on. For most component models this should be a
simple generic term for the type of device and attempt to
reuse established names for similar devices or models. In
cases where the Model and Spatial Classifications are
sufficient, this element can be omitted.
Specific Nature. This name element is used
to identify the nature of what is being reported for the
device or phenomena being modeled. This is where the most
low-level and specific detail is applied to describe the
output variable. This name element is nearly always
needed.
Dimensional Nature. This name element is
used to identify the nature of the physical dimensions of the
quantity being reported in words. This name element is nearly
always needed. This name element is the final part of the name
so that names end with terms that reflect the nature of the
value being reported. However, the name element should not be
the actual units. For example, an output that has units of
degrees Celsius, the final word in the name should be
“Temperature.” Or an output for air flow that has units of
kg/s, the final words in the name should be “Mass Flow Rate.”
When reporting on electricity use in Watts, the term “Power”
is used; however most other uses of Watts use the term
“Rate.”
Units. This name element is used to
identify the units of the value being reported. Units of
output variables are strictly SI, as used in EnergyPlus. Units
are concatenated on the end of the name with square brackets
and separated by a space and. Dimensionless quantities shall
use empty brackets “[ ].” The preferred set of units is listed
at the top of the Energy+.idd file. Units are always
abbreviated.
In some situations, a model may lend itself to generating a
series of related output variables that depend on input. For
example a surface heat transfer model may have results for
numerous individual nodes or cells across the thickness of the
surfaces. The number of nodes in the model will vary at
runtime depending on the Construction.
When this is the case, the standard approach used in
EnergyPlus is to produce a series of output variables by
enumerating the output variable name (rather than the key
value) to generate a specific name for each instance. The
generated name element for each instance in the series is
appended to the end of the name (but before the Units element)
and should end in a number. For example, the third node in a
stratified tank model is called “Chilled Water Thermal Storage
Temperature Node 3 [C].” This is done to facilitate
wildcarding when postprocessing output.
For Version
8.0, a comprehensive effort was made to rename output
variables to follow the guidelines and scheme described above.
As of Version
8.0 the existing output variables demonstrate the pattern and
should serve as good examples to follow for future output
variables. The following table lists a few examples of terms,
but these are not meant to be comprehensive or restrictive. It
is expected that new models may have valid reasons to
introduce new terms and units. Developers should examine RDD
output files for comprehensive lists of example output
variable names.
Output Variable Classifications
Model Classification
Spatial Classification
Type of Component
Dimensional Nature
AFN
Zone
Inside Face
Rate
Refrigeration
Surface
Outside Face
Rate per Area
Room Air
Linkage
Air Terminal
Energy
HAMT
Interior
Boiler
Temperature
CondFD
Exterior
Chiller
Mass Flow Rate
EMPD
Site
Cooling Coil
COP
Plant
Supply Side
Infiltration
Power (electric)
Environmental Impact
Air System
Unit Heater
Level
HVAC
Facility
Generator
Fraction
Setpoint Manager
Node
Baseboard
Status
The following table lists acronyms and symbols used in
output variable names.
Output Variable Example Abbreviations
Acronym
Definition
AC
Alternating Current
AFN
AirflowNetwork
Ar
Argon
ASHRAE
American Society of Heating,
Refrigeration, and Air-Conditioning Engineers, Inc.
BSDF
Bidirectional Scattering
Distribution Function
CEN
European Committee for
Standardization (Comite Europeen de Normalisation)
In EnergyPlus meters are an additional output reporting
capability. A meter is a way of grouping similar output
variables. Meters are output variables just like ordinary
output variables except that they sum or average a collection
of ordinary output variables. In EnergyPlus the meter
variables serve two purposes.
Providing output of fuel and electricity consumption by
end use categories and at the system plant, building and
facility level.
Providing a way of summing heating or cooling outputs for
a category of components. The resource type EnergyTransfer is
used for this purpose. An example would be reporting out the
sum of the heating energy from all the heating coils in a
system.
Meter output variables are created at the same time and in
the same manner as ordinary output variables.
SetupOutputVariable is called but the optional arguments
ResourceTypeKey, EndUseKey, and GroupKey must be used in
addition to the usual arguments. For example, in the electric
steam humidifier module
CALL SetupOutputVariable('Humidifier Electric Energy [J]', &
Humidifier(HumNum)%ElecUseEnergy, 'System','Sum', &
Humidifier(HumNum)%Name)
creates an output variable labeled ‘Humidifier Electric
Energy [J]’ with the value of
Humidifier(HumNum)%ElecUseEnergy.
CALL SetupOutputVariable('Humidifier Electric Energy [J]', &
Humidifier(HumNum)%ElecUseEnergy, 'System','Sum', &
Humidifier(HumNum)%Name, & ResourceTypeKey='ELECTRICITY',EndUseKey = 'HUMIDIFIER', &
GroupKey = 'System')
Creates the same output variable but in addition creates a
meter output variable Humidifier:Electricity [J]. This
variable will contain the sum of all the electricity
consumption of the humidifiers in the system. In addition,
this electrical consumption will be added into the meter
variables Electricity:HVAC [J] and Electricity:Facility
[J].
There are a number of rules developers must follow in order
to account for all electricity and fuel consumption as well as
to prevent consumables from being double counted.
Electricity and fuel meters must always be defined at the
simple component level. Some EnergyPlus components are
compound components: they are built up from simple components.
Examples are fan coils (composed of heating coils, cooling
coils, and fans), terminal units etc. Some example simple
components are heating and cooling coils, fans, humidifiers
etc. Electricity and fuel consumption should always be metered
at the simple component level and never at the compound
component level. This prevents double counting of the fuel or
energy consumption.
A variable should be metered once only. This means a
variable can be assigned to only one resource type and to only
one end use category.
Energy Transfer should be metered in the same way as fuel
or electricity use. Energy Transfer meters should only be
defined for simple components and should be assigned the same
end use category as the fuel or electricity consumption.
All fuel and electricity consumption must be put in some
(one) meter.
Use Energy Transfer judiciously; if in doubt, leave it
out.
Output Variable Dos and Don’ts[LINK]
For general output variables there aren’t many rules. For meter output variables there are quite a few. Here are some tips to keep you out of trouble.
What Variables Should I Output?[LINK]
The choice of variables to output is really up to the developer. Since variables don’t appear on the output file unless requested by the user in the IDF input file, it is better to “SetUp” too many rather than too few. For an HVAC component one should generally output the heating and cooling outputs of the component both in terms of energy and power. Energy is always output in Joules, power in Watts. If there is humidification or dehumidification both total and sensible cooling should be reported. Any electricity or fuel consumed by a component should be reported out, again both in terms of energy (Joules) and power (Watts). For HVAC components in most cases reporting inlet and outlet temperatures and humidities is unnecessary since these quantities can be obtained from the system node outputs.
Output Variable Naming Conventions[LINK]
The names for output variables need to be selected carefully to maintain a high level of consistency and clarity. Well-chosen names help users quickly understand the meaning of a specific output.
The following general guidelines are to be followed when choosing names for new output variables:
An output variable name should be constructed from up to six separate name elements. The following diagram shows the elements and the order that they are to be used in the name. The first three are each somewhat optional and are used as needed to identify the type of engineering model, object, or device being reported on. The last three are nearly always needed. Units are always needed (as described below.
Model Classification. This name element is used to identify the specific type of modeling being conducted. When used, it will form the first part of the name. This name element is often not needed, such as when the output is for a more or less usual aspect of buildings and HVAC system models. This is typically used to identify outputs that are associated with an alternative, usually more advanced, model, such as AirflowNetwork (AFN) or Conduction Finite Difference (CondFD). Although modeling domains such as Building, HVAC, or Internal Loads are usually obvious and not needed here, this classification can be useful for non-obvious sub-domains such as Environmental Impact, Refrigeration, or Daylighting.
Spatial Classification. This name element is used to identify spatial or topological location of the thing being reported on. It is generally used to identify which part of the building or system is being referred to by the output. For parts of the building, classifications such as “Zone” and “Surface” are the most common. For a model such as Refrigeration this classification may identify specific parts of the system, such as “Secondary Loop.” There is often no spatial or topological aspect needed and in that case this name element can be omitted.
Type of Component. This name element is used to identify the type of device or phenomena being modeled and reported on. For most component models this should be a simple generic term for the type of device and attempt to reuse established names for similar devices or models. In cases where the Model and Spatial Classifications are sufficient, this element can be omitted.
Specific Nature. This name element is used to identify the nature of what is being reported for the device or phenomena being modeled. This is where the most low-level and specific detail is applied to describe the output variable. This name element is nearly always needed.
Dimensional Nature. This name element is used to identify the nature of the physical dimensions of the quantity being reported in words. This name element is nearly always needed. This name element is the final part of the name so that names end with terms that reflect the nature of the value being reported. However, the name element should not be the actual units. For example, an output that has units of degrees Celsius, the final word in the name should be “Temperature.” Or an output for air flow that has units of kg/s, the final words in the name should be “Mass Flow Rate.” When reporting on electricity use in Watts, the term “Power” is used; however most other uses of Watts use the term “Rate.”
Units. This name element is used to identify the units of the value being reported. Units of output variables are strictly SI, as used in EnergyPlus. Units are concatenated on the end of the name with square brackets and separated by a space and. Dimensionless quantities shall use empty brackets “[ ].” The preferred set of units is listed at the top of the Energy+.idd file. Units are always abbreviated.
In some situations, a model may lend itself to generating a series of related output variables that depend on input. For example a surface heat transfer model may have results for numerous individual nodes or cells across the thickness of the surfaces. The number of nodes in the model will vary at runtime depending on the Construction. When this is the case, the standard approach used in EnergyPlus is to produce a series of output variables by enumerating the output variable name (rather than the key value) to generate a specific name for each instance. The generated name element for each instance in the series is appended to the end of the name (but before the Units element) and should end in a number. For example, the third node in a stratified tank model is called “Chilled Water Thermal Storage Temperature Node 3 [C].” This is done to facilitate wildcarding when postprocessing output.
For Version 8.0, a comprehensive effort was made to rename output variables to follow the guidelines and scheme described above. As of Version 8.0 the existing output variables demonstrate the pattern and should serve as good examples to follow for future output variables. The following table lists a few examples of terms, but these are not meant to be comprehensive or restrictive. It is expected that new models may have valid reasons to introduce new terms and units. Developers should examine RDD output files for comprehensive lists of example output variable names.
The following table lists acronyms and symbols used in output variable names.
What are Meters?[LINK]
In EnergyPlus meters are an additional output reporting capability. A meter is a way of grouping similar output variables. Meters are output variables just like ordinary output variables except that they sum or average a collection of ordinary output variables. In EnergyPlus the meter variables serve two purposes.
How Do I Create A Meter?[LINK]
Meter output variables are created at the same time and in the same manner as ordinary output variables. SetupOutputVariable is called but the optional arguments ResourceTypeKey, EndUseKey, and GroupKey must be used in addition to the usual arguments. For example, in the electric steam humidifier module
creates an output variable labeled ‘Humidifier Electric Energy [J]’ with the value of Humidifier(HumNum)%ElecUseEnergy.
Creates the same output variable but in addition creates a meter output variable Humidifier:Electricity [J]. This variable will contain the sum of all the electricity consumption of the humidifiers in the system. In addition, this electrical consumption will be added into the meter variables Electricity:HVAC [J] and Electricity:Facility [J].
Rules for Meter Variables[LINK]
There are a number of rules developers must follow in order to account for all electricity and fuel consumption as well as to prevent consumables from being double counted.
Electricity and fuel meters must always be defined at the simple component level. Some EnergyPlus components are compound components: they are built up from simple components. Examples are fan coils (composed of heating coils, cooling coils, and fans), terminal units etc. Some example simple components are heating and cooling coils, fans, humidifiers etc. Electricity and fuel consumption should always be metered at the simple component level and never at the compound component level. This prevents double counting of the fuel or energy consumption.
A variable should be metered once only. This means a variable can be assigned to only one resource type and to only one end use category.
Energy Transfer should be metered in the same way as fuel or electricity use. Energy Transfer meters should only be defined for simple components and should be assigned the same end use category as the fuel or electricity consumption.
All fuel and electricity consumption must be put in some (one) meter.
Use Energy Transfer judiciously; if in doubt, leave it out.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.