Using
the Interface Surface Temperature Results in EnergyPlus[LINK]
If the objects are placed in the normal EnergyPlus input
IDF file using the “GroundHeatTransfer:Basement:” prefix, then
the values resulting from the Basement preprocessor will be
automatically included in the simulation at run time. The
surfaces can reference these values using Outside Boundary
Conditions of:
- GroundBasementPreprocessorAverageWall
- GroundBasementPreprocessorAverageFloor
- GroundBasementPreprocessorUpperWall
- GroundBasementPreprocessorLowerWall
The objects that support this include:
- BuildingSurface:Detailed
- Wall:Detailed
- RoofCeiling:Detailed
- Floor:Detailed
The monthly results from the basement program are used with
the SurfaceProperty:OtherSideCoefficients
object in EnergyPlus. The idd corresponding to that object is
shown below. The two applicable fields are N2 and A2. N2
should have the value 1.0. It will be modified by a schedule
that is named in A2, and that temperature will be used on the
outside of the surface specified as having the
OtherSideCoeffcients named in A1.
SurfaceProperty:OtherSideCoefficients,
\memo This object sets the other side conditions for a surface in a variety of ways.
\min-fields 8
A1, \field Name
\required-field
\reference OSCNames
\reference OutFaceEnvNames
N1, \field Combined Convective/Radiative Film Coefficient
\required-field
\type real
\note if>0, this field becomes the exterior convective/radiative film coefficient
\note and the other fields are used to calculate the outdoor air temperature
\note then exterior surface temperature based on outdoor air and specified coefficient
\note if<=0, then remaining fields calculate the outside surface temperature
\note following fields are used in the equation:
\note SurfTemp=N7*TempZone + N4*OutdoorDry-bulb + N2*N3 + GroundTemp*N5 + WindSpeed*N6*OutdoorDry-bulb
N2, \field Constant Temperature
\units C
\type real
\default 0
\note This parameter will be overwritten by the values from the Constant Temperature Schedule Name (below) if one is present
N3, \field Constant Temperature Coefficient
\note This coefficient is used even with a Schedule. It should normally be 1.0 in that case
\default 1
N4, \field External Dry-Bulb Temperature Coefficient
\type real
\default 0
N5, \field Ground Temperature Coefficient
\type real
\default 0
N6, \field Wind Speed Coefficient
\type real
\default 0
N7, \field Zone Air Temperature Coefficient
\type real
\default 0
A2; \field Constant Temperature Schedule Name
\note Name of schedule for values of constant temperature.
\note Schedule values replace any value specified in the field Constant Temperature.
\type object-list
\object-list ScheduleNames
A sample idf for this object is shown below.
SurfaceProperty:OtherSideCoefficients, OSCCoef:Zn005:Wall003, !- OSC Name
! Example input for second ground temperature
0.0000000E+00, !- OSC SurfFilmCoef
0.000000 , !- OSC Temp
1.000000 , !- OSC Temp Coef
0.000000 , !- OSC dry-bulb
0.000000 , !- OSC GrndTemp
0.000000 , !- OSC WindSpdCoeff
0.000000 , !- OSC ZoneAirTemp
GroundTempSched; ! Name of schedule defining additional ground temperature.
The OSC object can be repeated for as many outside
temperatures as needed. A more detailed explanation of how to
use this object is contained in the next section, and an
example object is output by the program in the file
EPObjects.txt.
Multiple Ground
Temperatures[LINK]
These three objects show how the OtherSideCoefficients
object can be used to provide extra ground temperatures for
surfaces exposed to different ground temperatures.
Here is the surface description. Note that the
OutsideFaceEnvironment is specified as OtherSideCoeff.
BuildingSurface:Detailed,
!========================
OSCTest:South Wall, !- User Supplied Surface Name
Wall, !- Surface Type
Exterior, !- Construction Name of the Surface
OSCTest, !- Zone
OtherSideCoefficients, !- Outside Boundary Condition
ExampleOSC, !- Outside Boundary Condition Object
NoSun , !- Sun Exposure
NoWind , !- Wind Exposure
0.5, !- View Factor to Ground
4, !- Number of Vertices
0,0,0, !- Vertex 1 X,Y,Z-coordinates {m}
6.096,0,0, !- Vertex 2 X,Y,Z-coordinates {m}
6.096,0,4.572, !- Vertex 3 X,Y,Z-coordinates {m}
0,0,4.572; !- Vertex 4 X,Y,Z-coordinates {m}
The OtherSideCoefficients object has to supply the basic
form of the environment. Note that the name corresponds to
thee name in the Surface object. This object also supplies the
name of a schedule that will provide the monthly ground
temperature values.
SurfaceProperty:OtherSideCoefficients,
ExampleOSC, !- OtherSideCoeff Name
0, !- Combined convective/radiative film coefficient
1, !- User selected Constant Temperature {C}
1, !- Coefficient modifying the user selected constant temperature
0, !- Coefficient modifying the external dry bulb temperature
0, !- Coefficient modifying the ground temperature
0, !- Coefficient modifying the wind speed term (s/m)
0, !- Coefficient modifying the zone air temperature part of the equation
GroundTempCompactSched; !- Schedule Name for values of "const" temperature. Schedule values replace N2.
The schedule named in the last field of the
OtherSideCoefficients object must be supplied. In compact
schedule format it would appear as shown below. Again, objects
for each of the surface temperatures are produced by the
program and output in the file EPObjects.txt.
Schedule:Compact,
GroundTempCompactSched, !- Name
Temperature , !- ScheduleType
Through: 1/31, !- Complex Field #1
For:AllDays, !- Complex Field #2
Until: 24:00, !- Complex Field #3
16, !- Complex Field #4
Through: 2/28, !- Complex Field #5
For:AllDays, !- Complex Field #6
Until: 24:00, !- Complex Field #7
17, !- Complex Field #8
Through: 3/31, !- Complex Field #9
For:AllDays, !- Complex Field #10
Until: 24:00, !- Complex Field #11
18, !- Complex Field #12
Through: 4/30, !- Complex Field #13
For:AllDays, !- Complex Field #14
Until: 24:00, !- Complex Field #15
19, !- Complex Field #16
Through: 5/31, !- Complex Field #17
For:AllDays, !- Complex Field #18
Until: 24:00, !- Complex Field #19
20, !- Complex Field #20
Through: 6/30, !- Complex Field #21
For:AllDays, !- Complex Field #22
Until: 24:00, !- Complex Field #23
20, !- Complex Field #24
Through: 7/31, !- Complex Field #25
For:AllDays, !- Complex Field #26
Until: 24:00, !- Complex Field #27
20, !- Complex Field #28
Through: 8/31, !- Complex Field #29
For:AllDays, !- Complex Field #30
Until: 24:00, !- Complex Field #31
19, !- Complex Field #32
Through: 9/30, !- Complex Field #33
For:AllDays, !- Complex Field #34
Until: 24:00, !- Complex Field #35
18, !- Complex Field #36
Through: 10/31, !- Complex Field #37
For:AllDays, !- Complex Field #38
Until: 24:00, !- Complex Field #39
17, !- Complex Field #40
Through: 11/30, !- Complex Field #41
For:AllDays, !- Complex Field #42
Until: 24:00, !- Complex Field #43
16, !- Complex Field #44
Through: 12/31, !- Complex Field #45
For:AllDays, !- Complex Field #46
Until: 24:00, !- Complex Field #47
16; !- Complex Field #48
Using the Interface Surface Temperature Results in EnergyPlus[LINK]
If the objects are placed in the normal EnergyPlus input IDF file using the “GroundHeatTransfer:Basement:” prefix, then the values resulting from the Basement preprocessor will be automatically included in the simulation at run time. The surfaces can reference these values using Outside Boundary Conditions of:
The objects that support this include:
The monthly results from the basement program are used with the SurfaceProperty:OtherSideCoefficients object in EnergyPlus. The idd corresponding to that object is shown below. The two applicable fields are N2 and A2. N2 should have the value 1.0. It will be modified by a schedule that is named in A2, and that temperature will be used on the outside of the surface specified as having the OtherSideCoeffcients named in A1.
A sample idf for this object is shown below.
The OSC object can be repeated for as many outside temperatures as needed. A more detailed explanation of how to use this object is contained in the next section, and an example object is output by the program in the file EPObjects.txt.
Multiple Ground Temperatures[LINK]
These three objects show how the OtherSideCoefficients object can be used to provide extra ground temperatures for surfaces exposed to different ground temperatures.
Here is the surface description. Note that the OutsideFaceEnvironment is specified as OtherSideCoeff.
The OtherSideCoefficients object has to supply the basic form of the environment. Note that the name corresponds to thee name in the Surface object. This object also supplies the name of a schedule that will provide the monthly ground temperature values.
The schedule named in the last field of the OtherSideCoefficients object must be supplied. In compact schedule format it would appear as shown below. Again, objects for each of the surface temperatures are produced by the program and output in the file EPObjects.txt.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.