Output Details and Examples — EnergyPlus 8.3

<< Prev | Table of Contents | Object Index | Next >>

eplusout.dfs[LINK]

The daylight factors report contains the pre-calculated hourly daylight factors for the four CIE sky types (clear, clear turbid, intermediate, and overcast sky) and two daylight reference points for each exterior window of a daylight zone. The file is CSV formatted - ready for spreadsheet viewing. The input for requesting the report is simple:

The following shows an excerpt the daylight factors for a window without shade:

    This file contains daylight factors for all exterior windows of daylight zones.
    If only one reference point the last 4 columns in the data will be zero.
    MonthAndDay,Zone Name,Window Name,Window State
    Hour,Daylight Factor for Clear Sky at Reference point 1,Daylight Factor for Clear Turbid Sky at Reference point 1,Daylight Factor for Intermediate Sky at Reference point 1,Daylight Factor for Overcast Sky at Reference point 1,Daylight Factor for Clear Sky at Reference point 2,Daylight Factor for Clear Turbid Sky at Reference point 2,Daylight Factor for Intermediate Sky at Reference point 2,Daylight Factor for Overcast Sky at Reference point 2
    01/21,PERIMETER_BOT_ZN_1,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,Base Window
    1,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    2,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    3,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    4,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    5,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    6,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    7,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    8,5.08810E-002,5.78633E-002,2.59271E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    9,5.85018E-002,6.68126E-002,3.02054E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    10,6.26710E-002,7.12830E-002,3.37475E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    11,6.35876E-002,7.17181E-002,3.59982E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    12,6.23746E-002,6.98139E-002,3.66365E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    13,6.39669E-002,7.21972E-002,3.61684E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    14,6.25455E-002,7.10272E-002,3.39911E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    15,5.85994E-002,6.67866E-002,3.05581E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    16,5.17581E-002,5.89493E-002,2.63461E-002,1.42712E-002,0.00000,0.00000,0.00000,0.00000
    17,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    18,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    19,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    20,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    21,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    22,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    23,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000
    24,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000,0.00000

The first line describes the data in the eplusout.dfs file. The second line describes the header of the daily row:

Month and Day Zone Name Window Name Window State
01/21 PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW Base Window

The Window State column has three possible outputs - Base Window indicating windows without shades; a numeric value, from 0.0 to 180.0 for every 10.0 step, indicating the slat angle (in degrees) of the blind shading the window; blink indicating windows in shaded state by shades, screens, and blinds with fixed slat angle.

The third line describes the hourly daylight factors. Note that the last 4 columns are 0.0 because there is only one daylight reference point.:

Hour Daylight factor for clear sky at reference point 1 Daylight factor for clear turbid sky at reference point 1 Daylight factor for intermediate sky at reference point 1 Daylight factor for overcast sky at reference point 1 Daylight factor for clear sky at reference point 2 Daylight factor for clear turbid sky at reference point 2 Daylight factor for intermediate sky at reference point 2 Daylight factor for overcast sky at reference point 2
10 0.06239 0.07088 0.03377 0.01427 0.0 0.0 0.0 0.0