RunDirMulti Batch File[LINK]
The RunDirMulti.bat batch file runs all the IDF files in
the directory that it is located in. The batch file is used to
run EnergyPlus simulations using the RunEPlus.bat for all the
files in the current directory across multiple separate
processor cores. It has two parameters, the weather file name
to use for simulations and the number of processors.
RunDirMulti <weather file> (opt) <number processor
cores> (opt)
The RunDirMulti batch file loops through the files located
in the current directory and puts RunEPlus calls to each file
into as many temporary batch files as processor cores and then
starts each of the batch files. No load balancing between the
cores is achieved using this method. The RunDirMulti.bat file
should be located in a directory that contains the IDF files.
Editing of the file may be necessary to match the directory
that EnergyPlus is installed in.
Since the batch file starts up other batch files in
different CMD windows, the only way to know that the
simulations are all complete is when all of the other CMD
windows are closed. Those windows are named “Batch
Simulation<n>” where n is 1 to the number of processor
cores you selected to use.
Before use the RunDirMult.bat must have the maindir
variable set to the directory where the EnergyPlus program was
installed. Please edit the line in the RunDirMulti.bat file
that says:
SET maindir=
Add the full path for the directory that EnergyPlus is
installed after the equals sign and include double quotes
around the path. Make sure the end of the path ends with a
trailing backslash. For example:
SET maindir="c:\EnergyPlusVx-x-x\"
where the x’s are replaced with the actual version number
if EnergyPlus was installed in the default installation
directory.
RunDirMulti Batch File[LINK]
The RunDirMulti.bat batch file runs all the IDF files in the directory that it is located in. The batch file is used to run EnergyPlus simulations using the RunEPlus.bat for all the files in the current directory across multiple separate processor cores. It has two parameters, the weather file name to use for simulations and the number of processors.
RunDirMulti <weather file> (opt) <number processor cores> (opt)
The RunDirMulti batch file loops through the files located in the current directory and puts RunEPlus calls to each file into as many temporary batch files as processor cores and then starts each of the batch files. No load balancing between the cores is achieved using this method. The RunDirMulti.bat file should be located in a directory that contains the IDF files. Editing of the file may be necessary to match the directory that EnergyPlus is installed in.
Since the batch file starts up other batch files in different CMD windows, the only way to know that the simulations are all complete is when all of the other CMD windows are closed. Those windows are named “Batch Simulation<n>” where n is 1 to the number of processor cores you selected to use.
Before use the RunDirMult.bat must have the maindir variable set to the directory where the EnergyPlus program was installed. Please edit the line in the RunDirMulti.bat file that says:
SET maindir=
Add the full path for the directory that EnergyPlus is installed after the equals sign and include double quotes around the path. Make sure the end of the path ends with a trailing backslash. For example:
SET maindir="c:\EnergyPlusVx-x-x\"
where the x’s are replaced with the actual version number if EnergyPlus was installed in the default installation directory.
Documentation content copyright © 1996-2026 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.