Tabular Summary Reports[LINK]
Several predefined reports are available from the Output Table:Predefined object including the following.
- Annual Building Utility Performance Summary
- Input Verification and Results Summary
- Demand End Use Components Summary
- Source Energy End Use Components Summary
- Climatic Data Summary
- Equipment Summary
- Envelope Summary
- Surface Shadowing Summary
- Shading Summary
- Lighting Summary
- HVAC Sizing Summary
- System Summary
- Component Sizing Summary
- Outside Air Summary
- Object Count Summary
In addition, specifying “All Summary” will enable all the reports in this category (more than are shown here).
First and foremost, the Annual Building Utility Performance Summary gives a good overview of the energy use by category:
Report: AnnualBuildingUtilityPerformanceSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Values gathered over 8760.00 hours
Site and Source Energy
|
Total Site Energy
|
180.73
|
194.92
|
|
Net Site Energy
|
180.73
|
194.92
|
|
Total Source Energy
|
1141.64
|
1231.28
|
|
Net Source Energy
|
1141.64
|
1231.28
|
Source to Site Energy Conversion Factors
| Electricity |
| Natural Gas |
| District Cooling |
| District Heating |
| Steam |
| Gasoline |
| Diesel |
| Coal |
| Fuel Oil #1 |
| Fuel Oil #2 |
| Propane |
Building Area
End Uses
|
Heating
|
0.00
|
28.16
|
0.00
|
0.00
|
0.00
|
|
Cooling
|
16.56
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
81.24
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
47.70
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
6.59
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
0.48
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Refrigeration
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
|
|
|
|
|
|
|
Total End Uses
|
152.57
|
28.16
|
0.00
|
0.00
|
0.00
|
Note: Natural gas appears to be the principal heating source based on energy usage. End Uses By Subcategory
|
Heating
|
Boiler
|
0.00
|
28.16
|
0.00
|
0.00
|
0.00
|
|
|
Boiler Parasitic
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Cooling
|
General
|
16.56
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
GeneralLights
|
81.24
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
General
|
47.70
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
General
|
6.59
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
General
|
0.48
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Refrigeration
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
General
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
Normalized MetricsUtility Use Per Conditioned Floor Area
|
Lighting
|
87.62
|
0.00
|
0.00
|
0.00
|
0.00
|
|
HVAC
|
25.49
|
30.37
|
0.00
|
0.00
|
0.00
|
|
Other
|
51.44
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Total
|
164.55
|
30.37
|
0.00
|
0.00
|
0.00
|
Utility Use Per Total Floor Area
|
Lighting
|
87.62
|
0.00
|
0.00
|
0.00
|
0.00
|
|
HVAC
|
25.49
|
30.37
|
0.00
|
0.00
|
0.00
|
|
Other
|
51.44
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Total
|
164.55
|
30.37
|
0.00
|
0.00
|
0.00
|
Electric Loads Satisfied
| Fuel-Fired Power Generation |
0.00 |
| High Temperature Geothermal* |
0.00 |
| Photovoltaic Power |
0.00 |
| Wind Power* |
0.00 |
| Net Decrease in On-Site Storage |
0.00 |
| Total On-Site Electric Sources |
0.00 |
| |
|
| Electricity Coming From Utility |
152.57 |
| Surplus Electricity Going To Utility |
0.00 |
| Net Electricity From Utility |
152.57 |
| |
|
| Total On-Site and Utility Electric Sources |
152.57 |
| Total Electricity End Uses |
152.57 |
On-Site Thermal Sources
| Water-Side Heat Recovery |
0.00 |
| Air to Air Heat Recovery for Cooling |
0.00 |
| Air to Air Heat Recovery for Heating |
0.00 |
| High-Temperature Geothermal* |
0.00 |
| Solar Water Thermal |
0.00 |
| Solar Air Thermal |
0.00 |
| Total On-Site Thermal Sources |
0.00 |
Water Source Summary
| Rainwater Collection |
0.00 |
| Condensate Collection |
0.00 |
| Groundwater Well |
0.00 |
| Total On Site Water Sources |
0.00 |
| - |
- |
| Initial Storage |
0.00 |
| Final Storage |
0.00 |
| Change in Storage |
0.00 |
| - |
- |
| Water Supplied by Utility |
0.00 |
| - |
- |
| Total On Site, Change in Storage, and Utility Water Sources |
0.00 |
| Total Water End Uses |
0.00 |
Comfort and Setpoint Not Met Summary
| Time Set Point Not Met During Occupied Heating |
| Time Set Point Not Met During Occupied Cooling |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 |
Note 1: An asterisk (*) indicates that the feature is not yet implemented.
The input verification summary gives a good overview of the facility being simulated:
Report: InputVerificationandResultsSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
General
| Program Version and Build |
| Weather |
| Latitude [deg] |
| Longitude [deg] |
| Elevation [m] |
| Time Zone
|
| North Axis Angle [deg] |
| Rotation for Appendix G [deg] |
| Hours Simulated [hrs] |
ENVELOPEWindow-Wall Ratio
|
Gross Wall Area [m2]
|
274.20
|
91.50
|
45.60
|
91.50
|
|
Window Opening Area [m2]
|
60.90
|
20.85
|
9.12
|
21.81
|
|
Window-Wall Ratio [%]
|
22.21
|
22.79
|
20.00
|
23.84
|
Skylight-Roof Ratio
| Gross Roof Area [m2] |
| Skylight Area [m2] |
| Skylight-Roof Ratio [%] |
PERFORMANCEZone Summary
|
PLENUM-1
|
463.60
|
Yes
|
283.20
|
1.00
|
54.84
|
0.00
|
0.0000
|
|
|
SPACE1-1
|
99.16
|
Yes
|
239.25
|
1.00
|
73.20
|
21.81
|
15.9742
|
9.01
|
|
SPACE2-1
|
42.73
|
Yes
|
103.31
|
1.00
|
36.48
|
9.12
|
16.0056
|
8.55
|
|
SPACE3-1
|
96.48
|
Yes
|
239.25
|
1.00
|
73.20
|
20.85
|
16.4179
|
8.77
|
|
SPACE4-1
|
42.73
|
Yes
|
103.31
|
1.00
|
36.48
|
9.12
|
16.0056
|
8.55
|
|
SPACE5-1
|
182.49
|
Yes
|
447.68
|
1.00
|
0.00
|
0.00
|
16.2420
|
9.12
|
|
Total
|
927.20
|
|
1416.00
|
|
274.20
|
60.90
|
8.0889
|
17.83
|
|
Conditioned Total
|
927.20
|
|
1416.00
|
|
274.20
|
60.90
|
8.0889
|
17.83
|
|
Unconditioned Total
|
0.00
|
|
0.00
|
|
0.00
|
0.00
|
|
|
Source Energy End Use Components Summary[LINK]
The source energy end use components summary gives a good overview of the source energy consumption broken down by end uses for the facility being simulated:
Report: SourceEnergyEndUseComponentsSummary
For: Entire Facility
Timestamp: 2011-10-07 20:53:43
Values gathered over 8760.00 hoursSource Energy End Use Components Summary
|
Heating
|
0.00
|
140.03
|
0.00
|
0.00
|
|
Cooling
|
167.65
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
569.39
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
325.49
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
55.72
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
7.57
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Refrigeration
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
0.00
|
0.00
|
0.00
|
0.00
|
|
|
|
|
|
|
|
Total Source Energy End Use Components
|
1125.82
|
140.03
|
0.00
|
0.00
|
Normalized MetricsSource Energy End Use Components Per Conditioned Floor Area
|
Heating
|
0.00
|
151.02
|
0.00
|
0.00
|
|
Cooling
|
180.82
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
614.09
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
351.05
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
60.10
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
8.16
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Refrigeration
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
0.00
|
0.00
|
0.00
|
0.00
|
|
|
|
|
|
|
|
Total Source Energy End Use Components
|
1214.22
|
151.02
|
0.00
|
0.00
|
Source Energy End Use Components Per Total Floor Area
|
Heating
|
0.00
|
151.02
|
0.00
|
0.00
|
|
Cooling
|
180.82
|
0.00
|
0.00
|
0.00
|
|
Interior Lighting
|
614.09
|
0.00
|
0.00
|
0.00
|
|
Exterior Lighting
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Interior Equipment
|
351.05
|
0.00
|
0.00
|
0.00
|
|
Exterior Equipment
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Fans
|
60.10
|
0.00
|
0.00
|
0.00
|
|
Pumps
|
8.16
|
0.00
|
0.00
|
0.00
|
|
Heat Rejection
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Humidification
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Heat Recovery
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Water Systems
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Refrigeration
|
0.00
|
0.00
|
0.00
|
0.00
|
|
Generators
|
0.00
|
0.00
|
0.00
|
0.00
|
|
|
|
|
|
|
|
Total Source Energy End Use Components
|
1214.22
|
151.02
|
0.00
|
0.00
|
Other Summary Reports[LINK]
The Climatic Data Summary, Envelope Summary and Equipment Summary reports might be quite important to some reporting or presentation.
Report: ClimaticDataSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
SizingPeriod:DesignDay
|
LOS_ANGELES_CA_USA HEATING 99% CONDITIONS
|
7.40
|
0.00
|
7.40
|
0
|
2.80
|
|
LOS_ANGELES_CA_USA COOLING 1% CONDITIONS DB=>MWB
|
27.00
|
6.10
|
17.60
|
0
|
4.40
|
Weather Statistics File
| Reference |
| Site:Location |
| Latitude |
| Longitude |
| Time Zone
|
| Elevation |
| Standard Pressure at Elevation |
| Data Source |
| WMO Station |
| Design Conditions |
| Heating Design Temperature 99.6% (C) |
| Heating Design Temperature 99% (C) |
| Cooling Design Temperature 0.4% (C) |
| Cooling Design Temperature 1% (C) |
| Cooling Design Temperature 2% (C) |
| Maximum Dry Bulb Temperature (C) |
| Maximum Dry Bulb Occurs on |
| Minimum Dry Bulb Temperature (C) |
| Minimum Dry Bulb Occurs on |
| Maximum Dew Point Temperature (C) |
| Maximum Dew Point Occurs on |
| Minimum Dew Point Temperature (C) |
| Minimum Dew Point Occurs on |
| Heating Degree-Days (base 10°C) |
| Cooling Degree-Days (base 18°C) |
| Köppen Classification |
| Köppen Description |
| Köppen Recommendation |
| ASHRAE Climate Zone
|
| ASHRAE Description |
Report: EnvelopeSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Opaque Exterior
|
WALL-1PF
|
WALL-1
|
0.22
|
0.384
|
0.408
|
18.30
|
210.00
|
90.00
|
|
WALL-1PR
|
WALL-1
|
0.22
|
0.384
|
0.408
|
9.12
|
120.00
|
90.00
|
|
WALL-1PB
|
WALL-1
|
0.22
|
0.384
|
0.408
|
18.30
|
30.00
|
90.00
|
|
WALL-1PL
|
WALL-1
|
0.22
|
0.384
|
0.408
|
9.12
|
300.00
|
90.00
|
|
TOP-1
|
ROOF-1
|
0.35
|
0.268
|
0.282
|
463.60
|
210.00
|
0.00
|
|
FRONT-1
|
WALL-1
|
0.22
|
0.384
|
0.408
|
73.20
|
210.00
|
90.00
|
|
F1-1
|
FLOOR-SLAB-1
|
0.35
|
3.119
|
12.894
|
99.16
|
30.00
|
180.00
|
|
RIGHT-1
|
WALL-1
|
0.22
|
0.384
|
0.408
|
36.48
|
120.00
|
90.00
|
|
F2-1
|
FLOOR-SLAB-1
|
0.35
|
3.119
|
12.894
|
42.73
|
300.00
|
180.00
|
|
BACK-1
|
WALL-1
|
0.22
|
0.384
|
0.408
|
73.20
|
30.00
|
90.00
|
|
F3-1
|
FLOOR-SLAB-1
|
0.35
|
3.119
|
12.894
|
96.48
|
74.22
|
180.00
|
|
LEFT-1
|
WALL-1
|
0.22
|
0.384
|
0.408
|
36.48
|
300.00
|
90.00
|
|
F4-1
|
FLOOR-SLAB-1
|
0.35
|
3.119
|
12.894
|
42.73
|
120.00
|
180.00
|
|
F5-1
|
FLOOR-SLAB-1
|
0.35
|
3.119
|
12.894
|
182.49
|
30.00
|
180.00
|
Fenestration
|
WF-1
|
DBL CLR 3MM/13MM AIR
|
16.56
|
16.56
|
2.720
|
0.764
|
0.812
|
No
|
FRONT-1
|
210.00
|
|
DF-1
|
SGL GREY 3MM
|
5.25
|
5.25
|
5.894
|
0.716
|
0.611
|
No
|
FRONT-1
|
210.00
|
|
WR-1
|
DBL CLR 3MM/13MM AIR
|
9.12
|
9.12
|
2.720
|
0.764
|
0.812
|
No
|
RIGHT-1
|
120.00
|
|
WB-1
|
DBL CLR 3MM/13MM AIR
|
16.44
|
16.44
|
2.720
|
0.764
|
0.812
|
No
|
BACK-1
|
30.00
|
|
DB-1
|
SGL GREY 3MM
|
4.41
|
4.41
|
5.894
|
0.716
|
0.611
|
No
|
BACK-1
|
30.00
|
|
WL-1
|
DBL CLR 3MM/13MM AIR
|
9.12
|
9.12
|
2.720
|
0.764
|
0.812
|
No
|
LEFT-1
|
300.00
|
|
Total or Average
|
|
|
60.90
|
3.22
|
0.756
|
0.780
|
|
|
|
|
North Total or Average
|
|
|
20.85
|
3.39
|
0.754
|
0.769
|
|
|
|
|
Non-North Total or Average
|
|
|
40.05
|
3.14
|
0.757
|
0.785
|
|
|
|
Report: ShadingSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Sunlit Fraction
|
WF-1
|
0.00
|
0.00
|
0.26
|
0.00
|
0.00
|
0.00
|
0.00
|
0.30
|
|
DF-1
|
0.75
|
0.13
|
0.59
|
0.00
|
0.00
|
0.35
|
0.92
|
0.62
|
|
WR-1
|
1.00
|
1.00
|
0.00
|
1.00
|
1.00
|
0.00
|
1.00
|
1.00
|
|
WB-1
|
0.00
|
0.00
|
0.00
|
1.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
DB-1
|
0.00
|
0.00
|
0.00
|
1.00
|
0.00
|
0.00
|
0.00
|
0.00
|
|
WL-1
|
0.00
|
0.00
|
1.00
|
0.00
|
0.00
|
1.00
|
0.00
|
0.00
|
Window Control
Report: LightingSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Interior Lighting
|
SPACE1-1 LIGHTS 1
|
SPACE1-1
|
15.9742
|
99.16
|
1584.00
|
GeneralLights
|
LIGHTS-1
|
0.00
|
0.2000
|
|
SPACE2-1 LIGHTS 1
|
SPACE2-1
|
16.0056
|
42.73
|
684.00
|
GeneralLights
|
LIGHTS-1
|
0.00
|
0.2000
|
|
SPACE3-1 LIGHTS 1
|
SPACE3-1
|
16.4179
|
96.48
|
1584.00
|
GeneralLights
|
LIGHTS-1
|
0.00
|
0.2000
|
|
SPACE4-1 LIGHTS 1
|
SPACE4-1
|
16.0056
|
42.73
|
684.00
|
GeneralLights
|
LIGHTS-1
|
0.00
|
0.2000
|
|
SPACE5-1 LIGHTS 1
|
SPACE5-1
|
16.2420
|
182.49
|
2964.00
|
GeneralLights
|
LIGHTS-1
|
0.00
|
0.2000
|
|
Interior Lighting Total
|
|
16.1777
|
463.60
|
7500.00
|
|
|
|
|
Daylighting
Exterior Lighting
|
Exterior Lighting Total
|
0.00
|
|
|
Report: EquipmentSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Central Plant
Cooling Coils
Heating Coils
Fans
Pumps
Service Water Heating
Tabular Summary Reports[LINK]
Several predefined reports are available from the Output Table:Predefined object including the following.
In addition, specifying “All Summary” will enable all the reports in this category (more than are shown here).
Annual Building Utility Performance Summary[LINK]
First and foremost, the Annual Building Utility Performance Summary gives a good overview of the energy use by category:
Report: AnnualBuildingUtilityPerformanceSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Values gathered over 8760.00 hours
Site and Source Energy
Source to Site Energy Conversion Factors
Building Area
End Uses
Note: Natural gas appears to be the principal heating source based on energy usage. End Uses By Subcategory
Normalized MetricsUtility Use Per Conditioned Floor Area
Utility Use Per Total Floor Area
Electric Loads Satisfied
On-Site Thermal Sources
Water Source Summary
Comfort and Setpoint Not Met Summary
Note 1: An asterisk (*) indicates that the feature is not yet implemented.
Input Verification Summary[LINK]
The input verification summary gives a good overview of the facility being simulated:
Report: InputVerificationandResultsSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
General
ENVELOPEWindow-Wall Ratio
Skylight-Roof Ratio
PERFORMANCEZone Summary
Source Energy End Use Components Summary[LINK]
The source energy end use components summary gives a good overview of the source energy consumption broken down by end uses for the facility being simulated:
Report: SourceEnergyEndUseComponentsSummary
For: Entire Facility
Timestamp: 2011-10-07 20:53:43
Values gathered over 8760.00 hoursSource Energy End Use Components Summary
Normalized MetricsSource Energy End Use Components Per Conditioned Floor Area
Source Energy End Use Components Per Total Floor Area
Other Summary Reports[LINK]
The Climatic Data Summary, Envelope Summary and Equipment Summary reports might be quite important to some reporting or presentation.
Report: ClimaticDataSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
SizingPeriod:DesignDay
Weather Statistics File
Report: EnvelopeSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Opaque Exterior
Fenestration
Report: ShadingSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Sunlit Fraction
Window Control
Report: LightingSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Interior Lighting
Daylighting
Exterior Lighting
Report: EquipmentSummary
For: Entire Facility
Timestamp: 2009-09-17 17:30:22
Central Plant
Cooling Coils
Heating Coils
Fans
Pumps
Service Water Heating
Documentation content copyright © 1996-2015 The Board of Trustees of the University of Illinois and the Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory. All rights reserved. EnergyPlus is a trademark of the US Department of Energy.
This documentation is made available under the EnergyPlus Open Source License v1.0.