- EnergyPlusTM
Documentation, v8.4.0
- Output
Details and Examples
- Introduction
- Output
Files
- Output
File List
- eplusout.audit
- eplusout.bnd
- eplusout.dbg
- eplusout.dxf
- eplusout.edd
- eplusout.eio
- Simulation
Parameters
- Version
- Timestep
- SimulationControl
- Building
- Inside
Convection Algorithm
- Outside
Convection Algorithm
- Solution
Algorithm
- Sky
Radiance Distribution
- Site
Atmospheric Variation
- Shadowing/Sun
Position Calculations
- AirflowNetwork
Model:Control
- AirflowNetwork
Model:Wind Direction
- AirflowNetwork
Model:Wind Pressure Coefficients
- Zone
Volume Capacitance Multiplier
- Program
Control
- Climate
Group Outputs
- Climate
Group – Simple Outputs
- Location
- Weather
Station
- Site
Atmospheric Variation
- Ground
Temperatures and Ground Reflectances
- Ground
Temperatures
- Ground
Reflectance
- Snow
Ground Reflectance Modifiers
- Snow
Ground Reflectance
- Snow
Ground Reflectance for Daylighting
- Climate
Group – Not so Simple Outputs
- Environment
Line
- Design
Day Misc Line
- Special Day
Line
- Daylight
Saving Line
- Zone
Outputs
- Zone Summary
- Zone
Information
- Internal Gains
Outputs
- Zone
Internal Gains
- People Gains
- Lights Gains
- Equipment
(Electric, Gas, Steam, Hot Water) Gains
- Other
Equipment Gains
- Outdoor
Controlled Baseboard Heat
- Simple
Airflow Outputs
- Infiltration,
Ventilation, Mixing, Cross Mixing Statistics
- Infiltration
- Ventilation
- Mixing
- Cross Mixing
- RefrigerationDoor
Mixing
- Shading
Summary
- Surface
Details Report
- Calculating
with Surface Details Report
- Surface
Convection Parameters
- OtherSideCoefficient
Outputs
- Construction
Element Outputs
- Opaque
Constructions
- Window
Constructions
- Material:WindowGlass
- Material:WindowBlind
- ThermoChromic
Windows
- Complex
Fenestration
- HAMT Cell
Data
- Sizing
Information
- Zone
Sizing Information
- System
Sizing Information
- Plant
Coincident Sizing Algorithm
- Component
Sizing Information
- Heating/Cooling
Coil Capacity Information
- Refrigerated
Case and WalkIn Output
- Header
Record: #Refrigeration Compressor Racks
- Field:
Number ofRefrigeration Compressor Racks
- Header
Record: Refrigeration Compressor Rack
- Field:
Compressor Rack Name
- Field:
# Refrigerated Cases Connected
- Field:
# WalkInCoolers Connected
- Field:
Heat Rejection Location
- Field: COP
- Header
Record: Refrigeration Case
- Field:
Refrigeration Case Number
- Field:
Refrigeration Case Name
- Field: Zone
Name
- Field: Zone
Node #
- Field:
Zone Node Name
- Field:
Capacity
- Field: LHR
- Field:
Temperature {C}
- Field: Length
{m}
- Field: Fan
{W/m}
- Field:Installed
Lighting {W/m}
- Field:
Anti-Sweat {W/m}
- Field:
Defrost {W/m}
- Header
Record: Refrigeration Walk In Cooler
- Field:
Walk In Number
- Field: Walk
In Name
- Field:
Capacity
- Field:
Temperature {C}
- Field: Coil
Fan {W}
- Field:
Circulation Fan {W}
- Field:
Lighting {W}
- Field: Heaters
{W}
- Field: Defrost
{W}
- Field: #
Zones
- Header
Record: Walk-In Surfaces Facing Zone
- Field: Zone
Name
- Field:
Wall/Ceiling Area {m2}
- [Field: UValue
{W/m2-C]}](eplusout-eio.html#field-uvalue-wm2-c)
- Field:
AreaStockDoors {m2}
- Field:
HeightStockDoors {m}
- [Field: UValueStockDoors
{W/m2-C]}](eplusout-eio.html#field-uvaluestockdoors-wm2-c)
- Field:
AreaGlassDoors {m2}
- Field:
HeightGlassDoors {m}
- [Field: UValueGlassDoors
{W/m2-C]}](eplusout-eio.html#field-uvalueglassdoors-wm2-c)
- Header
Record: #Detailed Refrigeration Systems
- Field:
Number of Detailed Refrigeration Systems
- Header
Record: Detailed Refrigeration System
- Field:
Refrigeration System Name
- Field:
Refrigerant Used
- Field:
# Refrigerated Cases Connected
- Field:
# WalkInCoolers Connected
- Field: #
Secondary Loops Served
- Field:
# Cascade Condensers Served
- Field:
# Mechanical Subcoolers Served
- Field: #
Compressors Connected
- Field: #
Compression Stages
- Field:
Intercooler Type
- Field:
Intercooler Effectiveness
- Field: #
Subcoolers Connected
- Field:
Minimum Condensing Temperature (C)
- Header
Record: #Detailed Transcritical Refrigeration Systems
- Field:
Number of Detailed Transcritical Refrigeration
Systems
- Header
Record: Detailed Transcritical Refrigeration System
- Field:
Transcritical Refrigeration System Name
- Field:
Refrigerant Used
- Field:
# Medium Temperature Refrigerated Cases Connected
- Field:
# Low Temperature Refrigerated Cases Connected
- Field:
# Medium Temperature WalkInCoolers Connected
- Field:
# Low Temperature WalkInCoolers Connected
- Field:
# High Pressure Compressors Connected
- Field:
# Low Pressure Compressors Connected
- Field:
Minimum Condensing Temperature (C)
- Header
Record: Cascade Load
- Field:
System Name Connected
- Field:
Condenser Number
- Field:
Condenser Name
- Header
Record: Secondary Load
- Field:
Secondary System Served Name
- Field:
Secondary Number
- Header
Record: Mechanical Subcooler Load
- Field:
Subcooler Number
- Field:
Subcooler Name
- Header
Record: Refrigeration Compressor
- Field:
Compressor Number
- Field:
Compressor Name
- Field:
Nominal Capacity, W
- Header
Record: Refrigeration Condenser, Air-Cooled
- Field:
Condenser Number
- Field:
Condenser Name
- Field:
Rated Condensing Temperature, C
- Field:
Rated Capacity, W
- Field:
Rated Fan Power, W
- Header
Record: Refrigeration Condenser, Water-Cooled
- Field:
Condenser Number
- Field:
Condenser Name
- Field:
Rated Condensing Temperature, C
- Field: Rated
Capacity, W
- Field:
Rated Water Inlet Temperature, C
- Field:
Rated Water Flow Rate, m3/s
- Header
Record: Refrigeration Condenser, Evaporative-Cooled
- Field:
Condenser Number
- Field:
Condenser Name
- Field: Rated
Capacity, W
- Field:
Rated Fan Power, W
- Header
Record: Refrigeration Condenser, Cascade
- Field:
Condenser Number
- Field:
Condenser Name
- Field:
Condensing Temperature Control Type,
- Field:
Rated Condensing Temperature, C
- Field: Rated
Capacity, W
- Field:
Approach Temperature Difference, DeltaC
- Header
Record: Refrigeration GasCooler:Air-Cooled
- Field:
Gas Cooler Number
- Field:
Gas Cooler Name
- Field:
Rated Outlet Pressure, Pa
- Field:
Rated Outlet Temperature, C
- Field:
Rated Approach Temperature, C
- Field: Rated
Capacity, W
- Field:
Rated Fan Power, W
- Header
Record: Refrigeration Mechanical Subcooler
- Field:
Subcooler Number
- Field:
Subcooler Name
- Field:
Name of System Providing Cooling
- Field:
Design Outlet Temperature, C
- Header
Record: Refrigeration Liquid Suction Subcooler
- Field:
Subcooler Number
- Field:
Subcooler Name
- Field:
Design Subcooling, deltaC
- Field:
Design liquid inlet temperature, C
- Field:
Design vapor inlet temperature, C
- Header
Record: # Secondary Refrigeration Systems
- Field:
Number of Secondary Refrigeration Systems
- Header
Record: Secondary Refrigeration System: Fluid Always
Liquid
- Field:
Secondary Number
- Field:
Secondary Name
- Field:
# Refrigerated Cases Connected
- Field:
# WalkInCoolers Connected
- Field: Fluid
Name
- Field:
Capacity, W
- Field:
Evap Temperature in Secondary Evaporator, C
- Field:
Approach Temperature Difference, DeltaC
- Field:
Temperature Range, DeltaC
- Field:
TotalPumpPower, W
- Header
Record: Secondary Refrigeration System: Liquid
Overfeed
- Field:
Secondary Number
- Field:
Secondary Name
- Field:
# Refrigerated Cases Connected
- Field:
# WalkInCoolers Connected
- Field:
Fluid Name
- Field:
Capacity, W
- Field:
Evap Temperature in Secondary Evaporator, C
- Field:
Approach Temperature Difference, DeltaC
- Field:
Circulating Rate
- Field:
TotalPumpPower, W
- Header
Record: #Orphaned Refrigerated Cases
- Field:
Number of Orphaned Refrigerated Cases
- Field:
Message
- Header
Record: Orphaned Refrigerated Case
- Field:
Refrigerated Case Number
- Field:
Refrigerated Case Name
- Field: Zone
Name
- Field: Zone
Node #
- Field:
Zone Node Name
- Header
Record: #Orphaned Walk Ins
- Field:
Number of OrphanedWalk Ins
- Field:
Message
- Header
Record: Orphaned Walk In
- Field:Walk
In Number
- Field:
Walk In Name
- Header
Record: #Orphaned Refrigeration Compressors
- Field:
Number of Orphaned Refrigeration Compressors
- Field:
Message
- Header
Record: Orphaned Refrigeration Compressor
- Field:Compressor
Number
- Field:
Compressor Name
- Header
Record: #Orphaned Refrigeration Secondary Loops
- Field:
Number of Orphaned Secondary Loops
- Field:
Message
- Header
Record: Orphaned Refrigeration Secondary Loop
- Field:Secondary
Number
- Field:
Secondary Name
- View Factor
Info
- View
Factor Details
- DX Coil
Outputs
- DX
Cooling Coil Outputs
- DX
Cooling Coil Outputs for ASHRAE 127 Standard Ratings
- DX
Heating Coil Outputs
- Chiller
Outputs
- Lookup
Table Outputs
- How to
Access the SQLite Data
- eplusssz.
- epluszsz.
- eplusout.
- eplusmtr.
- eplusmap.
- eplusout.dfs
- eplusscreen.csv
- eplustbl.
- readvars.rvaudit
- eplusout.svg
- eplusout.sci
- eplusout.wrl
- Delight
output files
- Example
Input Files
- Data Sets
- Simple
List Data Sets
- Macro Data
Sets