Table of Contents: Input Output Reference — EnergyPlus 8.0
Table of Contents
|
Object Index
All 8.0 Docs
|
Docs Home
Input Output Reference
The Encyclopedic Reference to EnergyPlus Input and Output
Input-Output Reference
What’s different about EnergyPlus Input and Output?
EnergyPlus Input Processing
General Input Rules
EnergyPlus Output Processing
IDD Conventions
IDD – IP Units
Input – Output Descriptions (Document)
Input Descriptions
Output Descriptions
Group – Simulation Parameters
Version
Field: Version Identifier
Timestep
Field: Number of Timesteps per Hour
ConvergenceLimits
Field: Minimum System Timestep
Field: Maximum HVAC Iterations
Field: Minimum Plant Iterations
Field: Maximum Plant Iterations
Building
Field: Building Name
Field: North Axis
Field: Terrain
Warmup Convergence
Field: Loads Convergence Tolerance Value
Field: Temperature Convergence Tolerance Value
Field: Solar Distribution
Field: Maximum Number of Warmup Days
Field: Minimum Number of Warmup Days
SurfaceConvectionAlgorithm:Inside
Field: Algorithm
SurfaceConvectionAlgorithm:Outside
Field: Algorithm
HeatBalanceAlgorithm
Field: Algorithm
Field: Surface Temperature Upper Limit
Field: Minimum Surface Convection Heat Transfer Coefficient Value
Field: Maximum Surface Convection Heat Transfer Coefficient Value
HeatBalanceSettings:ConductionFiniteDifference
Field: Difference Scheme
Field: Space Discretization Constant
Field: Relaxation Factor
Field: Inside Face Surface Temperature Convergence Criteria
ZoneAirHeatBalanceAlgorithm
Field: Algorithm
ZoneAirContaminantBalance
Field: Carbon Dioxide Concentration
Field: Outdoor Carbon Dioxide Schedule Name
Field: Generic Contaminant Concentration
Field: Outdoor Generic Contaminant Schedule Name
Carbon Dioxide Outputs
Zone Air CO2 Concentration [ppm]
Zone Air CO2 Internal Gain Volume Flow Rate [m3/s]
Generic Contaminant Outputs
Zone Air Generic Air Contaminant Concentration [ppm]
Zone Generic Air Contaminant Generation Volume Flow Rate [m3/s]
ShadowCalculation
Field: Calculation Method
Field: Calculation Frequency
Field: Maximum Figures in Shadow Overlap Calculations
Field: Polygon Clipping Algorithm
Field: Sky Diffuse Modeling Algorithm
Output:Diagnostics
Field: key1, key2
Output:DebuggingData
Field: Report Debugging Data
Field: Report During Warmup”outputpreprocessormessage
Field: Preprocessor Name
Field: Error Severity
Fields: Message Line 1 through Message Line 10
ZoneCapacitanceMultiplier:ResearchSpecial
Field: Sensible Heat Capacity Multiplier
Field: Humidity Capacity Multiplier
Field: Carbon Dioxide Capacity Multiplier
SimulationControl
Field: Do Zone Sizing Calculation
Field: Do System Sizing Calculation
Field: Do Plant Sizing Calculation
Field: Run Simulation for Sizing Periods
Field: Run Simulation for Weather File Run Periods
ProgramControl
Field: Number of Threads Allowed
Meter:Custom
Field: Name
Field: Fuel Type
Field: group(s) Key Name-Output Variable/Meter Name
Field: Key Name
Field: Output Variable or Meter Name
Meter:CustomDecrement
Field: Name
Field: Fuel Type
Field: Source Meter Name
Field: group(s) Key Name-Output Variable/Meter Name
Field: Key Name
Field: Output Variable or Meter Name
Custom Meter Examples
Simulation Parameter Outputs
Group – Compliance Objects
Compliance:Building
Field: Building Rotation for Appendix G
Group – Location – Climate – Weather File Access
Site:Location
Field: Name
Field: Latitude
Field: Longitude
Field: Time Zone
Field: Elevation
SizingPeriod:DesignDay
Field: Name
Field: Month
Field: Day of Month
Field: Day Type
Field: Maximum Dry-Bulb Temperature
Field: Daily Dry-bulb Temperature Range
Field: Dry-Bulb Temperature Range Modifier Type
Field: Dry-Bulb Temperature Range Modifier Day Schedule Name
Field: Humidity Condition Type
Field: Wetbulb or DewPoint at Maximum Dry-Bulb
Field: Humidity Condition Day Schedule Name
Field: Humidity Ratio at Maximum Dry-Bulb
Field: Enthalpy at Maximum Dry-Bulb
Field: Daily Wet-Bulb Temperature Range
Field: Barometric Pressure
Field: Wind Speed
Field: Wind Direction
Field: Rain Indicator
Field: Snow Indicator
Field: Daylight Saving Time Indicator
Field: Solar Model Indicator
Field: Beam Solar Day Schedule Name
Field: Diffuse Solar Day Schedule Name
Field: ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub)
Field: ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud)
Field: Sky Clearness
Longer Design Periods
SizingPeriod:WeatherFileDays
Field: Name
Field: Begin Month
Field: Begin Day of Month
Field: End Month
Field: End Day of Month
Field: Day of Week for Start Day
Field: Use Weather File Daylight Saving Period
Field: Use Weather File Rain and Snow Indicators
SizingPeriod:WeatherFileConditionType
Field: Name
Field: Period Selection
Field: Day of Week for Start Day
Field: Use Weather File Daylight Saving Period
Field: Use Weather File Rain and Snow Indicators
RunPeriod
Field: Name
Field: Begin Month
Field: Begin Day of Month
Field: End Month
Field: End Day of Month
Field: Day of Week for Start Day
Field: Use Weather File Holidays and Special Days
Field: Use Weather File Daylight Saving Period
Field: Apply Weekend Holiday Rule
Field: Use Weather File Rain Indicators
Field: Use Weather File Snow Indicators
Field: Number of Times Runperiod to be Repeated
Field: Increment Day of Week on Repeat
Field: Start Year
RunPeriod:CustomRange
Field: Name
Field: Begin Month
Field: Begin Day of Month
Field: Begin Year
Field: End Month
Field: End Day of Month
Field: End Year
Field: Day of Week for Start Day
Field: Use Weather File Holidays and Special Days
Field: Use Weather File Daylight Saving Period
Field: Apply Weekend Holiday Rule
Field: Use Weather File Rain Indicators
Field: Use Weather File Snow Indicators
RunPeriodControl:SpecialDays
Field: Name
Field: Start Date
Field: Duration
Field: Special Day Type
RunPeriodControl:DaylightSavingTime
Field: Start Date
Field: End Date
WeatherProperty:SkyTemperature
Field: Name
Field: Calculation Type
Field: ScheduleName
Site:WeatherStation
Field: Wind Sensor Height Above Ground
Field: Wind Speed Profile Exponent
Field: Wind Speed Profile Boundary Layer Thickness
Field: Air Temperature Sensor Height Above Ground
Site:HeightVariation
Field: Wind Speed Profile Exponent
Field: Wind Speed Profile Boundary Layer Thickness
Field: Air Temperature Gradient Coefficient
Site:GroundTemperature:BuildingSurface
Field: Month Temperature(s) – 12 fields in all
Site:GroundTemperature:Shallow
Field: Month Temperature(s) – 12 fields in all
Site:GroundTemperature:Deep
Ground Heat Exchanger Average Borehole Temperature [C]
Ground Heat Exchanger Heat Transfer Rate [W]
Ground Heat Exchanger Inlet Temperature [C]
Ground Heat Exchanger Outlet Temperature [C]
Ground Heat Exchanger Mass Flow Rate [kg/s]
Ground Heat Exchanger Average Fluid Temperature [C]
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Field: Month Temperature(s) – 12 fields in all
Site:GroundTemperature:FCfactorMethod
Field: Month Temperature(s) – 12 fields in all
Site:GroundReflectance
Field: Month Average Ground Reflectance(s) – 12 fields in all
Site:GroundReflectance:SnowModifier
Field: Ground Reflected Solar Modifier
Field: Daylighting Ground Reflected Solar Modifier
Site:WaterMainsTemperature
Field: Calculation Method
Field: Schedule Name
Field: Annual Average Outdoor Air Temperature
Field: Maximum Difference In Monthly Average Outdoor Air Temperatures
Site:Precipitation
Field: Precipitation Model Type
Field: Design Level for Total Annual Precipitation
Field: Precipitation Rate Schedule Name
Field: Average Total Annual Precipitation
RoofIrrigation
Field: Irrigation Model Type
Field: Irrigation Rate Schedule Name
Field: Irrigation Maximum Saturation Threshold
Climate Group Outputs
Weather Data Related Outputs
Site Outdoor Air Drybulb Temperature [C]
Site Outdoor Air Dewpoint Temperature [C]
Site Outdoor Air Wetbulb Temperature [C]
Site Outdoor Air Humidity Ratio [kgWater/kgAir]
Site Outdoor Air Relative Humidity [%]
Site Outdoor Air Barometric Pressure [Pa]
Site Wind Speed [m/s]
Site Wind Direction [deg]
Site Sky Temperature [C]
Site Horizontal Infrared Radiation Rate per Area [W/m2]
Site Diffuse Solar Radiation Rate per Area [W/m2]
Site Direct Solar Radiation Rate per Area [W/m2]
Site Precipitation Depth [m]
Site Ground Reflected Solar Radiation Rate per Area [W/m2]
Site Ground Temperature [C]
Site Surface Ground Temperature [C]
Site Deep Ground Temperature [C]
Site Simple Factor Model Ground Temperature [C]
Site Outdoor Air Enthalpy [J/kg]
Site Outdoor Air Density [kg/m3]
Site Solar Azimuth Angle [deg]
Site Solar Altitude Angle [deg]
Site Solar Hour Angle [deg]
Site Rain Status []
Site Snow on Ground Status []
Site Daylight Saving Time Status []
Site Day Type Index []
Site Mains Water Temperature [C]
Site Precipitation Rate [m/s]
Site Precipitation Depth [m]
Water System Roof Irrigation Scheduled Depth[m]
Water System Roof Irrigation Actual Depth[m]
Outputs for local temperature/wind speed calculations
Zone Outdoor Air Drybulb Temperature [C]
Zone Outdoor Air Wetbulb Temperature [C]
Zone Outdoor Air Wind Speed [m/s]
Surface Ext Outdoor Dry Bulb [C]
Surface Ext Outdoor Wet Bulb [C]
Surface Ext Wind Speed [m/s]
System Node Temperature [C]
Group – Schedules
Day Type
ScheduleTypeLimits
Field: Name
Field: Lower Limit Value
Field: Upper Limit Value
Field: Numeric Type
Field: Unit Type
Day Schedules
Schedule:Day:Hourly
Field: Name
Field: Schedule Type Limits Name
Field: Hour Values (1-24)
Schedule:Day:Interval
Field: Name
Field: Schedule Type Limits Name
Field: Interpolate to Timestep
Field-Set: Time and Value (extensible object)
Field: Time
Field: Value
Schedule:Day:List
Field: Name
Field: Schedule Type Limits Name
Field: Interpolate to Timestep
Field: Minutes Per Item
Field Value 1 (same definition for each value – up to 1440 (24*60) allowed)
Week Schedule(s)
Schedule:Week:Daily
Field: Name
Field: Schedule Day Name Fields (12 day types – Sunday, Monday, … )
Schedule:Week:Compact
Field:Name
Field-Set – DayType List#, Schedule:Day Name
Field: DayType List
Field: Schedule:Day Name
Schedule:Year
Field: Name
Field: Schedule Type Limits Name
Field Set (WeekSchedule, Start Month and Day, End Month and Day)
Field: Schedule Week Name
Field: Start Month
Field: Start Day
Field: End Month
Field: End Day
Schedule:Compact
Field: Name
Field: Schedule Type Limits Name
Field-Set (Through, For, Interpolate, Until, Value)
Field: Through
Field: For
Field: Interpolate (optional)
Field: Until
Field: Value
Schedule:Constant
Field: Name
Field: Schedule Type Limits Name
Field: Hourly Value
Schedule:File
Field: Name
Field: Schedule Type Limits Name
Field: File Name
Field: Column Number
Field: Rows to Skip at Top
Field: Number of Hours of Data
Field: Column Separator
Field: Interpolate to Timestep
Field: Minutes Per Item
Schedule Outputs
Schedule Value Output
Schedule Value
Group – Surface Construction Elements
Specifying the Building Envelope
Material and Material Properties
Material
Field: Name
Field: Roughness
Field: Thickness
Field: Conductivity
Field: Density
Field: Specific Heat
Field: Thermal Absorptance
Field: Solar Absorptance
Field: Visible Absorptance
Material:NoMass
Field: Name
Field: Roughness
Field: Thermal Resistance
Field: Thermal Absorptance
Field: Solar Absorptance
Field: Visible Absorptance
Material:InfraredTransparent
Field: Name
Material:AirGap
Field: Name
Field: Thermal Resistance
MaterialProperty:MoisturePenetrationDepth:Settings
Field: Name
Field: Moisture Penetration Depth
Field: Constants to Define Moisture Equilibrium Equation
The next four fields are dimensionless coefficients:
Field: Moisture Equation Coefficient a
Field: Moisture Equation Coefficient b
Field: Moisture Equation Coefficient c
Field: Moisture Equation Coefficient d
Moisture Penetration Depth (EMPD) Outputs
EMPD Surface Inside Face Water Vapor Density [kg/m3]
EMPD Surface Inside Face Humidity Ratio [kgWater/kgDryAir]
EMPD Surface Inside Face Relative Humidity [%]
MaterialProperty:PhaseChange
Field: Name
Field: Temperature Coefficient for Thermal Conductivity
Field Set: Temperature-Enthalpy
Field: Temperature x
Field: Enthalpy x
MaterialProperty:VariableThermalConductivity
Field: Name
Field Set: Temperature-Thermal Conductivity
Field: Temperature x
Field: Thermal Conductivity x
Conduction Finite Difference (CondFD) Outputs
CondFD Inner Solver Loop Iteration Count []
CondFD Surface Temperature Node [C]
MaterialProperty:HeatAndMoistureTransfer:Settings
Field: Material Name
Field: Porosity
Field: Initial Water Content Ratio
MaterialProperty:HeatAndMoistureTransfer:SorptionIsotherm
Field: Material Name
Field: Number of data Coordinates
Field Set: Relative Humidity-Moisture Content
Field: Relative Humidity Fraction x
Field: Moisture Content x
MaterialProperty:HeatAndMoistureTransfer:Suction
Field: Material Name
Field: Number of Suction points
Field Set: Moisture Content-Liquid Transport Coefficient
Field: Moisture Content x
Field: Liquid Transport Coefficient x
MaterialProperty:HeatAndMoistureTransfer:Redistribution
Field: Material Name
Field: Number of Redistribution points
Field Set: Moisture Content– Liquid Transport Coefficient
Field: Moisture Content x
Field: Liquid Transport Coefficient x
MaterialProperty:HeatAndMoistureTransfer:Diffusion
Field: Material Name
Field: Number of Data Pairs
Field Set: Relative Humidity-Vapor Diffusion Resistance Factor
Field: Relative Humidity Fraction #x
Field: Vapor Diffusion Resistance Factor #x
MaterialProperty:HeatAndMoistureTransfer:ThermalConductivity
Field: Material Name
Field: Number of Thermal Coordinates
Field Set: Moisture Content- Thermal Conductivity
Field: Moisture Content x
Field: Thermal Conductivity x
Heat and Moisture (HAMT) Outputs
HAMT Surface Average Water Content Ratio [kg/kg]
HAMT Surface Inside Face Temperature [C]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Vapor Pressure [Pa]
HAMT Surface Outside Face Temperature [C]
HAMT Surface Outside Face Relative Humidity [%]
HAMT Surface Relative Humidity Cell [%]
HAMT Surface Temperature Cell [C]
HAMT Surface Water Content Cell [kg/kg]
Materials for Glass Windows and Doors
WindowMaterial:Glazing
Field: Name
Field: Optical Data Type
Field: Window Glass Spectral Data Set Name
Field: Thickness
Field: Solar Transmittance at Normal Incidence
Field: Front Side Solar Reflectance at Normal Incidence
Field: Back Side Solar Reflectance at Normal Incidence
Field: Visible Transmittance at Normal Incidence
Field: Front Side Visible Reflectance at Normal Incidence
Field: Back Side Visible Reflectance at Normal Incidence
Field: Infrared Transmittance at Normal Incidence
Field: Front Side Infrared Hemispherical Emissivity
Field: Back Side Infrared Hemispherical Emissivity
Field: Conductivity
Field: Dirt Correction Factor for Solar and Visible Transmittance
Field: Solar Diffusing
Field: Young’s modulus
Field: Poisson’s ratio
WindowMaterial:Glazing:RefractionExtinctionMethod
Field: Name
Field: Thickness
Field: Solar Index of Refraction
Field: Solar Extinction Coefficient
Field: Visible Index of Refraction
Field: Visible Extinction Coefficient
Field: Infrared Transmittance at Normal Incidence
Field: Infrared Hemispherical Emissivity
Field: Conductivity
Field: Dirt Correction Factor for Solar and Visible Transmittance
Field: Solar Diffusing
Glass Optical Properties Conversion
Conversion from Glass Optical Properties Specified as Index of Refraction and Transmittance at Normal Incidence
WindowMaterial:GlazingGroup:Thermochromic
Field: Name
Field Set (Optical Data Temperature, Window Material Glazing Name) is extensible.
Field: Optical Data Temperature
Field: Window Material Glazing Name
WindowMaterial:GlazingGroup:Thermochromic Outputs
Surface Window Thermochromic Layer Temperature [C]
Surface Window Thermochromic Layer Property Specification Temperature [C]
WindowMaterial:Gas
Field: Name
Field: Gas Type
Field: Thickness
Properties for Custom Gas Types
Field: Conductivity Coefficient A
Field: Conductivity Coefficient B
Field: Conductivity Coefficient C
Field: Viscosity Coefficient A
Field: Viscosity Coefficient B
Field: Viscosity Coefficient C
Field: Specific Heat Coefficient A
Field: Specific Heat Coefficient B
Field: Specific Heat Coefficient C
Field: Specific Heat Ratio
Field: Molecular Weight
Field: Specific Heat Ratio
WindowMaterial:GasMixture
Field: Name
Field: Thickness
Field: Number of Gases in Mixture
Set: Gas Type-Fraction (up to 4)
Field: Gas 1 Type
Field: Gas 1 Fraction
WindowMaterial:Gap
Field: Name
Field: Thickness
Field: Pressure
Field: Deflection State
Field: Support Pillar
Field: Gas (or GasMixture)
WindowGap:DeflectionState
Field: Name
Field: Deflected Thickness
WindowGap:SupportPillar
Field: Name
Field: Spacing
Field: Radius
WindowMaterial:SimpleGlazingSystem
Field: Name
Field: U-Factor
Field: Solar Heat Gain Coefficient
Field: Visible Transmittance
WindowMaterial:Shade
Method 1:
Method 2:
Field: Name
Field: Solar Transmittance
Field: Solar Reflectance
Field: Visible Transmittance
Field: Visible Reflectance
Field: Thermal Hemispherical Emissivity
Field: Thermal Transmittance
Field: Thickness
Field: Conductivity
Field: Shade to Glass Distance
Field: Top Opening Multiplier
Field: Bottom Opening Multiplier
Field: Left-Side Opening Multiplier
Field: Right-Side Opening Multiplier
Field: Field: Air-Flow Permeability
WindowMaterial:Blind
Method 1:
Method 2:
Field: Name
Field: Slat Orientation
Field: Slat Width
Field: Slat Separation
Field: Slat Thickness
Field: Slat Angle
Field: Slat Conductivity
Field: Slat Beam Solar Transmittance
Field: Front Side Slat Beam Solar Reflectance
Field: Back Side Slat Beam Solar Reflectance
Field: Slat Diffuse Solar Transmittance
Field: Front Side Slat Diffuse Solar Reflectance
Field: Back Side Slat Diffuse Solar Reflectance
Field: Slat Beam Visible Transmittance
Field: Front Side Slat Beam Visible Reflectance
Field: Back Side Slat Beam Visible Reflectance
Field: Slat Diffuse Visible Transmittance
Field: Front Side Slat Diffuse Visible Reflectance
Field: Back Side Slat Diffuse Visible Reflectance
Field: Slat Infrared Hemispherical Transmittance
Field: Front Side Slat Infrared Hemispherical Emissivity
Field: Back Side Slat Infrared Hemispherical Emissivity
Field: Blind to Glass Distance
Opening Multipliers
Field: Blind Top Opening Multiplier
Field: Blind Bottom Opening Multiplier
Field: Blind Left-Side Opening Multiplier
Field: Blind Right-Side Opening Multiplier
Field: Minimum Slat Angle
Field: Maximum Slat Angle
WindowMaterial:ComplexShade
Field: Name
Field: Shading Layer Type
Field: Thickness
Field: Conductivity
Field: IR Transmittance
Field: Front Emissivity
Field: Back Emissivity
Field: Top Opening Multiplier
Field: Bottom Opening Multiplier
Field: Left Side Opening Multiplier
Field: Right Side Opening Multiplier
Field: Front Opening Multiplier
Field: Slat Width
Field: Slat Spacing
Field: Slat Thickness
Field: Slat Angle
Field: Slat Conductivity
Field: Slat Curve
WindowMaterial:Screen
Method 1:
Method 2:
Field: Name
Field: Reflected Beam Transmittance Accounting Method
Field: Diffuse Solar Reflectance
Field: Diffuse Visible Reflectance
Field: Thermal Hemispherical Emissivity
Field: Conductivity
Field: Screen Material Spacing
Field: Screen Material Diameter
Field: Screen to Glass Distance
Field: Top Opening Multiplier
Field: Bottom Opening Multiplier
Field: Left-Side Opening Multiplier
Field: Right-Side Opening Multiplier
Field: Angle of Resolution for Screen Transmittance Output Map
Material:RoofVegetation
Field: Name
Field: Height of Plants
Field: Leaf Area Index
Field: Leaf Reflectivity
Field: Leaf Emissivity
Field: Minimum Stomatal Resistance
Field: Soil Layer Name
Field: Roughness
Field: Thickness
Field: Conductivity of Dry Soil
Field: Density of Dry Soil
Field: Specific Heat of Dry Soil
Field: Thermal Absorptance
Field: Solar Absorptance
Field: Visible Absorptance
Field: Saturation Volumetric Moisture Content of the Soil Layer
Field: Residual Volumetric Moisture Content of the Soil Layer
Field: Initial Volumetric Moisture Content of the Soil Layer
Field: Moisture Diffusion Calculation Method
Ecoroof / RoofVegetation outputs
Green Roof Soil Temperature [C]
Green Roof Vegetation Temperature [C]
Green Roof Soil Root Moisture Ratio []
Green Roof Soil Near Surface Moisture Ratio []
Green Roof Soil Sensible Heat Transfer Rate per Area [W/m2]
Green Roof Vegetation Sensible Heat Transfer Rate per Area [W/m2]
Green Roof Vegetation Moisture Transfer Rate [m/s]
Green Roof Soil Moisture Transfer Rate [m/s]
Green Roof Vegetation Latent Heat Transfer Rate per Area [W/m2]
Green Roof Soil Latent Heat Transfer Rate per Area [W/m2]
Green Roof Cumulative Precipitation Depth [m]
Green Roof Current Precipitation Depth [m]
Green Roof Cumulative Irrigation Depth [m]
Green Roof Current Irrigation Depth [m]
Green Roof Cumulative Runoff Depth [m]
Green Roof Current Runoff Depth [m]
Green Roof Cumulative Evapotranspiration Depth [m]
Green Roof Current Evapotranspiration Depth [m]
MaterialProperty:GlazingSpectralData
Field: Name
Fields 1-4 (repeated up to 450 times)
Construction
Field: Name
Field: Outside Layer
HAMT Surface Average Water Content Ratio [kg/kg]
HAMT Surface Inside Face Temperature [C]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Vapor Pressure [Pa]
HAMT Surface Outside Face Temperature [C]
HAMT Surface Outside Face Relative Humidity [%]
HAMT Surface Relative Humidity Cell [%]
HAMT Surface Temperature Cell [C]
HAMT Surface Water Content Cell [kg/kg]
Field(s) 2-10: Layers
Site:GroundTemperature:FCfactorMethod
Field: Month Temperature(s) – 12 fields in all
Constructions - Modeling Underground Walls and Ground Floors Defined with C and F Factors for Building Energy Code Compliance
Construction:CfactorUndergroundWall
Field: Name
Field: C-Factor
Field: Height
Construction:FfactorGroundFloor
Field: Name
Field: F-Factor
Field: Area
Field: PerimeterExposed
Construction:InternalSource
Field: Name
Field: Source Present After Layer Number
Field: Temperature Calculation Requested After Layer Number
Field: Dimensions for the CTF Calculation
Field: Tube Spacing
Field: Outside Layer
HAMT Surface Average Water Content Ratio [kg/kg]
HAMT Surface Inside Face Temperature [C]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Relative Humidity [%]
HAMT Surface Inside Face Vapor Pressure [Pa]
HAMT Surface Outside Face Temperature [C]
HAMT Surface Outside Face Relative Humidity [%]
HAMT Surface Relative Humidity Cell [%]
HAMT Surface Temperature Cell [C]
HAMT Surface Water Content Cell [kg/kg]
Field(s) 2-10: Layers
Composite Wall Constructions
Construction:ComplexFenestrationState
Field: Name
Field: Basis Type keyword
Field: Basis Symmetry, keyword
Field: Thermal Parameters
Field: Basis Matrix Name
Field: Solar Optical Complex Front Transmittance Matrix Name
Field: Solar Optical Complex Back Reflectance Matrix Name
Field: Visible Optical Complex Front Transmittance Matrix Name
Field: Visible Optical Complex Back Reflectance Matrix Name
Field: Outside Layer
Each construction must have at least one layer. The layer order is from outside to inside, with the first layer being either WindowMaterial:Glazing or WindowMaterial:ComplexShade. The next layer is a WindowMaterial:Gap layer, and the following layers then alternate between WindowMaterial:Glazing or WindowMaterial:ComplexShade and WindowMaterial:Gap. The last layer cannot be WindowMaterial:Gap.Field: Outside Layer directional front absorptance matrix Name
Field: Outside Layer directional back absorptance matrix Name
Above 3 fields are optionally repeated for layers 2-10
WindowThermalModel:Params
Field: Name
Field: Calculation Standard
Field: Thermal Model
Field: SD Scalar
Field: Deflection Model
Field: Vacuum Pressure Limit
Field: Initial Temperature
Field: Initial Pressure
Matix:TwoDimension
Field: Name
Field: Number of Rows
Field: Number of Columns
< Field Set: Value # N >
Field: Value # 1
Field: Value #2
Construction:WindowDataFile
Field: Name
Field: File Name
Construction Element Outputs
Group – Thermal Zone Description/Geometry
Zone
Field: Direction of Relative North
Field(s): (X,Y,Z) Origin
Field: Type
Field: Multiplier
Field: Ceiling Height
Field: Volume
Field: Floor Area
Field: Zone Inside Convection Algorithm
Field: Zone Outside Convection Algorithm
Field: Part of Total Floor Area
Zone Outputs
Zone Outdoor Air Drybulb Temperature [C]
Zone Outdoor Air Wetbulb Temperature [C]
Zone Outdoor Air Wind Speed [m/s]
Zone Thermal Output(s)
Zone Mean Air Temperature [C]
Zone Air Temperature [C]
Zone Mean Air Dewpoint Temperature [C]
Zone Thermostat Air Temperature [C]
Zone Mean Radiant Temperature [C]
Zone Operative Temperature [C]
Zone Air Heat Balance Internal Convective Heat Gain Rate [W]
Zone Air Heat Balance Surface Convection Rate [W]
Zone Air Heat Balance Interzone Air Transfer Rate [W]
Zone Air Heat Balance Outdoor Air Transfer Rate [W]
Zone Air Heat Balance System Air Transfer Rate [W]
Zone Air Heat Balance System Convective Heat Gain Rate [W]
Zone Air Heat Balance Air Energy Storage Rate [W]
Zone Air Heat Balance Deviation Rate [W]
Zone Air System Sensible Heating Energy [J]
Zone Air System Sensible Cooling Energy [J]
Zone Air System Sensible Heating Rate [W]
Zone Air System Sensible Cooling Rate [W]
Zone Air Humidity Ratio [kgWater/kgDryAir]
Zone Air Relative Humidity [%]
Zone Total Internal Radiant Heating Rate [W]
Zone Total Internal Radiant Heating Energy [J]
Zone Total Internal Visible Radiation Heating Rate [W]
Zone Total Internal Visible Radiation Heating Energy [J]
Zone Total Internal Convective Heating Rate [W]
Zone Total Internal Convective Heating Energy [J]
Zone Total Internal Latent Gain Rate [W]
Zone Total Internal Latent Gain Energy [J]
Zone Total Internal Total Heating Rate [W]
Zone Total Internal Total Heating Energy [J]
ZoneList
Field: Zone List Name
Field: Zone 1 – 20 Name
ZoneList Outputs
ZoneGroup
Tips for Multi-Story Simulations:
Field: Zone Group Name
Field: Zone List Name
Field: Zone List Multiplier
ZoneGroup Outputs
Surface(s)
Interzone Surfaces
Surface View Factors
GlobalGeometryRules
Field: Starting Vertex Position
Field: Vertex Entry Direction
Field: Coordinate System
Field: Daylighting Reference Point Coordinate System
Field: Rectangular Surface Coordinate System
Surfaces
Walls
Wall:Exterior
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Wall:Adiabatic
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Wall:Underground
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Wall:Interzone
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition Object
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Roofs/Ceilings
Roof
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Ceiling:Adiabatic
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Ceiling:Interzone
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition Object
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Floors
Floor:GroundContact
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Floor:Adiabatic
Field: Name
Field: Construction Name
Field: Zone Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Floor:Interzone
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition Object
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Width
Windows/Doors
Window
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Shading Control Name
Field: Frame and Divider Name
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Door
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
GlazedDoor
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Shading Control Name
Field: Frame and Divider Name
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Window:Interzone
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Outside Boundary Condition Object
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Door:Interzone
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Outside Boundary Condition Object
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
GlazedDoor:Interzone
Field: Name
Field: Construction Name
Field: Building Surface Name
Field: Outside Boundary Condition Object
Field: Multiplier
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Surface Vertices
Building Surfaces - Detailed
Wall:Detailed
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition
Field: Outside Boundary Condition Object
Field: Sun Exposure
Field: Wind Exposure
Field: View Factor to Ground
Field: Number of Vertices
RoofCeiling:Detailed
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition
Field: Outside Boundary Condition Object
Field: Sun Exposure
Field: Wind Exposure
Field: View Factor to Ground
Field: Number of Vertices
Floor:Detailed
Field: Name
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition
Field: Outside Boundary Condition Object
Field: Sun Exposure
Field: Wind Exposure
Field: View Factor to Ground
Field: Number of Vertices
BuildingSurface:Detailed
Field: Name
Field: Surface Type
Field: Construction Name
Field: Zone Name
Field: Outside Boundary Condition
Field: Outside Boundary Condition Object
Field: Sun Exposure
Field: Wind Exposure
Field: View Factor to Ground
Field: Number of Vertices
FenestrationSurface:Detailed
Field: Name
Field: Surface Type
Field: Construction Name
Field: Building Surface Name
Field: Outside Boundary Condition Object
Field: View Factor to Ground
Field: Shading Control Name
Field: Frame and Divider Name
Field: Multiplier
Field: Number of Vertices
Fields: Vertex Coordinates
Window Modeling Options
InternalMass
Example
Example
Field: Name
Field: Construction Name
Field: Zone Name
Field: Surface Area
Surface Output Variables/Reports
Window Output Variables
Surface Output Variables (all heat transfer surfaces)
Surface Inside Face Heat Balance Calculation Iteration Count []
Surface Inside Face Temperature [C]
Surface Outside Face Temperature [C]
Surface Inside Face Adjacent Air Temperature [C]
Surface Inside Face Convection Heat Gain Rate [W]
Surface Inside Face Convection Heat Gain Rate per Area [W/m2]
Surface Inside Face Convection Heat Gain Energy [J]
Surface Inside Face Convection Heat Transfer Coefficient [W/m2-K]
Surface Inside Face Net Surface Thermal Radiation Heat Gain Rate [W]
Surface Inside Face Net Surface Thermal Radiation Heat Gain Rate per Area [W/m2]
Surface Inside Face Net Surface Thermal Radiation Heat Gain Energy [J]
Surface Inside Face Solar Radiation Heat Gain Rate [W]
Surface Inside Face Solar Radiation Heat Gain Rate per Area [W/m2]
Surface Inside Face Solar Radiation Heat Gain Energy [J]
Surface Inside Face Lights Radiation Heat Gain Rate [W]
Surface Inside Face Lights Radiation Heat Gain Rate per Area [W/m2]
Surface Inside Face Lights Radiation Heat Gain Energy [J]
Surface Inside Face Internal Gains Radiation Heat Gain Rate [W]
Surface Inside Face Internal Gains Radiation Heat Gain Rate per Area [W/m2]
Surface Inside Face Internal Gains Radiation Heat Gain Energy [J]
Surface Inside Face System Radiation Heat Gain Rate [W]
Surface Inside Face System Radiation Heat Gain Rate per Area [W/m2]
Surface Inside Face System Radiation Heat Gain Energy [J]
Surface Outside Face Convection Heat Gain Rate [W]
Surface Outside Face Convection Heat Gain Rate per Area [W/m2]
Surface Outside Face Convection Heat Gain Energy [J]
Surface Outside Face Convection Heat Transfer Coefficient [W/m2-K]
Surface Outside Face Net Thermal Radiation Heat Gain Rate [W]
Surface Outside Face Net Thermal Radiation Heat Gain Rate per Area [W/m2]
Surface Outside Face Net Thermal Radiation Heat Gain Energy [J]
Surface Inside Face Exterior Windows Incident Beam Solar Radiation Rate [W]
Surface Inside Face Exterior Windows Incident Beam Solar Radiation Rate per Area [W/m2]
Surface Inside Face Exterior Windows Incident Beam Solar Radiation Energy [J]
Surface Inside Face Interior Windows Incident Beam Solar Radiation Rate [W]
Surface Inside Face Interior Windows Incident Beam Solar Radiation Rate per Area [W/m2]
Surface Inside Face Interior Windows Incident Beam Solar Radiation Energy [J]
Surface Inside Face Initial Transmitted Diffuse Absorbed Solar Radiation Rate [W]
Surface Inside Face Absorbed Shortwave Radiation Rate [W]
Surface Output Variables (exterior heat transfer surfaces)
Surface Outside Face Outdoor Air Drybulb Temperature [C]
Surface Outside Face Outdoor Air Wetbulb Temperature [C]
Surface Outside Face Outdoor Air Wind Speed [m/s]
Surface Outside Face Sunlit Area [m2]
Surface Outside Face Sunlit Fraction []
Surface Outside Face Thermal Radiation to Air Heat Transfer Coefficient [W/m2-K]
Surface Outside Face Thermal Radiation to Sky Heat Transfer Coefficient [W/m2-K]
Surface Outside Face Thermal Radiation to Ground Heat Transfer Coefficient [W/m2-K]
Surface Outside Face Solar Radiation Heat Gain Rate [W]
Surface Outside Face Solar Radiation Heat Gain Rate per Area [W/m2]
Surface Outside Face Solar Radiation Heat Gain Energy [J]
Surface Outside Face Incident Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Beam Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Sky Diffuse Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Ground Diffuse Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Beam To Diffuse Ground Reflected Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Sky Diffuse Ground Reflected Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Sky Diffuse Surface Reflected Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Beam To Beam Surface Reflected Solar Radiation Rate per Area [W/m2]
Surface Outside Face Incident Beam To Diffuse Surface Reflected Solar Radiation Rate per Area [W/m2]
Surface Outside Face Beam Solar Incident Angle Cosine Value []
Surface Anisotropic Sky Multiplier []
Surface Window BSDF Beam Direction Number []
Surface Window BSDF Beam Phi Angle [rad]
Surface Window BSDF Beam Theta Angle [rad]
Opaque Surface Output Variables
Surface Inside Face Conduction Heat Transfer Rate [W]
Surface Inside Face Conduction Heat Transfer Rate per Area [W/m2]
Surface Inside Face Conduction Heat Gain Rate [W]
Surface Inside Face Conduction Heat Loss Rate [W]
Surface Outside Face Conduction Heat Transfer Rate [W]
Surface Outside Face Conduction Heat Transfer Rate per Area [W/m2]
Surface Outside Face Conduction Heat Gain Rate [W]
Surface Outside Face Conduction Heat Loss Rate [W]
Surface Average Face Conduction Heat Transfer Rate [W]
Surface Average Face Conduction Heat Transfer Rate per Area [W/m2]
Surface Average Face Conduction Heat Gain Rate [W]
Surface Average Face Conduction Heat Loss Rate [W]
Surface Average Face Conduction Heat Transfer Energy [J]
Surface Heat Storage Rate [W]
Surface Heat Storage Rate per Area [W/m2]
Surface Heat Storage Gain Rate [W]
Surface Heat Storage Loss Rate [W]
Surface Heat Storage Energy [J]
Surface Internal Source Location Temperature [C]
Zone Opaque Surface Inside Face Conduction [W]
Zone Opaque Surface Inside Faces Total Conduction Heat Gain Rate [W]
Zone Opaque Surface Inside Faces Total Conduction Heat Gain Energy [J]
Zone Opaque Surface Inside Faces Total Conduction Heat Loss Rate [W]
Zone Opaque Surface Inside Faces Total Conduction Heat Loss Energy [J]
Zone Opaque Surface Outside Face Conduction [W]
Zone Opaque Surface Outside Face Conduction Gain [W]
Zone Opaque Surface Outside Face Conduction Gain Energy [J]
Zone Opaque Surface Outside Face Conduction Loss [W]
Zone Opaque Surface Outside Face Conduction Loss Energy [J]
Surface Inside Face Beam Solar Radiation Heat Gain Rate [W]
Window Output Variables
Zone Windows Total Transmitted Solar Radiation Rate [W]
Zone Windows Total Transmitted Solar Radiation Energy [J]
Zone Windows Total Heat Gain Rate [W]
Zone Windows Total Heat Gain Energy [J]
Zone Windows Total Heat Loss Rate [W]
Zone Windows Total Heat Loss Energy [J]
Surface Window Total Glazing Layers Absorbed Shortwave Radiation Rate [W]
Surface Window Total Glazing Layers Absorbed Solar Radiation Rate [W]
Surface Window Total Glazing Layers Absorbed Solar Radiation Energy [J]
Surface Window Shading Device Absorbed Solar Radiation Rate [W]
Surface Window Transmitted Solar Radiation Rate [W]
Surface Window Transmitted Solar Radiation Energy [J]
Surface Window Transmitted Beam Solar Radiation Rate [W]
Surface Window Transmitted Beam Solar Radiation Energy [J]
Surface Window Transmitted Beam To Beam Solar Radiation Rate [W]
Surface Window Transmitted Beam To Beam Solar Radiation Energy [J]
For a window with a blind, this transmitted radiation consists of beam radiation that passes between the slats. For a window with a screen, this value consists of direct beam radiation that is transmitted through the screen (gaps between the screen material).
Surface Window Transmitted Beam To Diffuse Solar Radiation Rate [W]
Surface Window Transmitted Beam To Diffuse Solar Radiation Energy [J]
For a window with a blind, this transmitted radiation consists of diffuse radiation reflected from beam by the slats. For a window with a screen, this value consists of diffuse radiation reflected by the screen material.
Zone Exterior Windows Total Transmitted Beam Solar Radiation Rate [W]
Zone Exterior Windows Total Transmitted Beam Solar Radiation Energy [J]
Zone Interior Windows Total Transmitted Beam Solar Radiation Rate [W]
Zone Interior Windows Total Transmitted Beam Solar Radiation Energy [J]
Surface Window Transmitted Diffuse Solar Radiation Rate [W]
Surface Window Transmitted Diffuse Solar Radiation Energy [J]
Zone Exterior Windows Total Transmitted Diffuse Solar Radiation Rate [W]
Zone Exterior Windows Total Transmitted Diffuse Solar Radiation Energy [J]
Zone Interior Windows Total Transmitted Diffuse Solar Radiation Rate [W]
Zone Interior Windows Total Transmitted Diffuse Solar Radiation Energy [J]
Surface Window System Solar Transmittance []
Surface Window System Solar Absorptance []
Surface Window System Solar Reflectance []
Surface Window Gap Convective Heat Transfer Rate [W]
Surface Window Gap Convective Heat Transfer Energy [J]
Surface Window Heat Gain Rate [W]
Surface Window Heat Gain Energy [J]
Surface Window Outside Reveal Reflected Beam Solar Radiation Rate [W]
Surface Window Outside Reveal Reflected Beam Solar Radiation Energy [J]
Surface Window Inside Reveal Reflected Beam Solar Radiation Rate [W]
Surface Window Inside Reveal Reflected Beam Solar Radiation Energy [J]
Surface Window Inside Reveal Absorbed Beam Solar Radiation Rate [W]
Surface Window Inside Reveal Reflected Diffuse Zone Solar Radiation Rate [W]
Surface Window Inside Reveal Reflected Diffuse Frame Solar Radiation Rate [W]
Surface Window Inside Reveal Reflected Diffuse Glazing Solar Radiation Rate [W]
Surface Window Inside Face Glazing Condensation Status []
Surface Window Inside Face Frame Condensation Status []
Surface Window Inside Face Divider Condensation Status []
Surface Shading Device Is On Time Fraction []
Surface Window Blind Slat Angle [deg]
Surface Window Blind Beam to Beam Solar Transmittance []
Surface Window Blind Beam to Diffuse Solar Transmittance []
Surface Window Blind Diffuse to Diffuse Solar Transmittance []
Surface Window Blind and Glazing System Beam Solar Transmittance []
Surface Window Blind and Glazing System Diffuse Solar Transmittance []
Surface Window Screen Beam to Beam Solar Transmittance []
Surface Window Screen Beam to Diffuse Solar Transmittance[]
Surface Window Screen Diffuse to Diffuse Solar Transmittance[]
Surface Window Screen and Glazing System Beam Solar Transmittance[]
Surface Window Screen and Glazing System Diffuse Solar Transmittance []
Surface Window Transmitted Beam Solar Radiation Rate [W]
Surface Window Transmitted Beam Solar Radiation Energy [J]
Surface Storm Window On Off Status [ ]
Surface Inside Face Initial Transmitted Diffuse Transmitted Out Window Solar Radiation Rate [W]
Additional Window Outputs (Advanced)
Surface Window Inside Face Glazing Zone Convection Heat Gain Rate [W]
Surface Window Inside Face Glazing Net Infrared Heat Transfer Rate [W]
Surface Window Shortwave from Zone Back Out Window Heat Transfer Rate [W]
Surface Window Inside Face Frame and Divider Zone Heat Gain Rate [W]
Surface Window Frame Heat Gain Rate [W]
Surface Window Frame Heat Loss Rate [W]
Surface Window Frame Inside Temperature [C]
Surface Window Frame Outside Temperature [C]
Surface Window Divider Heat Gain Rate [W]
Surface Window Divider Heat Loss Rate [W]
Surface Window Divider Inside Temperature [C]
Surface Window Divider Outside Temperature [C]
Surface Window Inside Face Gap between Shade and Glazing Zone Convection Heat Gain Rate [W]
Surface Window Inside Face Shade Zone Convection Heat Gain Rate [W]
Surface Window Inside Face Shade Net Infrared Heat Transfer Rate [W]
Thermochomic Window Outputs
Window Thermochromic Layer Temperature [C]
Surface Window Thermochromic Layer Property Specification Temperature [C]
Switchable Window Outputs
Surface Window Switchable Glazing Switching Factor[]
Surface Window Switchable Glazing Visible Transmittance[]
Other Surface Outputs/Reports
DXF
Details, Vertices, DetailsWithVertices
Shading Surfaces
Detached Shading Surfaces
Shading:Site, Shading:Building
Field: Name
Field: Azimuth Angle
Field: Tilt Angle
Starting Corner for the surface
Field: Starting X Coordinate
Field: Starting Y Coordinate
Field: Starting Z Coordinate
Field: Length
Field: Height
Shading:Site:Detailed, Shading:Building:Detailed
Field: Name
Field: Transmittance Schedule Name
Field: Number Vertices
Attached Shading Surfaces
Shading:Overhang
Field: Name
Field: Window or Door Name
Field: Height above Window or Door
Field Tilt Angle from Window/Door
Field: Left Extension from Window/Door Width
Field: Right Extension from Window/Door Width
Field: Depth
Shading:Overhang:Projection
Field: Name
Field: Window or Door Name
Field: Height above Window or Door
Field Tilt Angle from Window/Door
Field: Left Extension from Window/Door Width
Field: Right Extension from Window/Door Width
Field: Depth as Fraction of Window/Door Height
Shading:Fin
Field: Name
Field: Window or Door Name
Field: Left Fin Extension from Window/Door
Field: Left Fin Distance Above Top of Window
Field: Left Fin Distance Below Bottom of Window
Field: Left Fin Tilt Angle from Window/Door
Field: Left Fin Depth
Field: Right Fin Extension from Window/Door
Field: Right Fin Distance Above Top of Window
Field: Right Fin Distance Below Bottom of Window
Field: Right Fin Tilt Angle from Window/Door
Field: Right Fin Depth
Shading:Fin:Projection
Field: Name
Field: Window or Door Name
Field: Left Fin Extension from Window/Door
Field: Left Fin Distance Above Top of Window
Field: Left Fin Distance Below Bottom of Window
Field: Left Fin Tilt Angle from Window/Door
Field: Left Fin Depth as Fraction of Window/Door Width
Field: Right Fin Extension from Window/Door
Field: Right Fin Distance Above Top of Window
Field: Right Fin Distance Below Bottom of Window
Field: Right Fin Tilt Angle from Window/Door
Field: Right Fin Depth as Fraction of Window/Door Width
Shading:Zone:Detailed
Field: Name
Field: Base Surface Name
Field: Transmittance Schedule Name
Field: Number Vertices
ShadingProperty:Reflectance
Field: Shading Surface Name
Field: Diffuse Solar Reflectance of Unglazed Part of Shading Surface
Field: Diffuse Visible Reflectance of Unglazed Part of Shading Surface
Field: Fraction of Shading Surface That Is Glazed
Field: Glazing Construction Name
WindowProperty:ShadingControl
Specify “Name of Construction with Shading”
Specify the “Material Name of the Shading Device”
Field: Name
Field: Shading Type
Field: Construction with Shading Name
Field: Shading Control Type
Field: Schedule Name
Field: Setpoint
Field: Shading Control Is Scheduled
Field: Glare Control Is Active
Field: Shading Device Material Name
Field: Type of Slat Angle Control for Blinds
Field: Slat Angle Schedule Name
Field: Setpoint 2
WindowProperty:FrameAndDivider
Field: Name
Field: Frame Width
Field: Frame Outside Projection
Field: Frame Inside Projection
Field: Frame Conductance
Field: Ratio of Frame-Edge Glass Conductance to Center-Of-Glass Conductance
Field: Frame Solar Absorptance
Field: Frame Visible Absorptance
Field: Frame Thermal Hemispherical Emissivity
Field: Divider Type
Field: Divider Width
Field: Number of Horizontal Dividers
Field: Number of Vertical Dividers
Field: Divider Outside Projection
Field: Divider Inside Projection
Field: Divider Conductance
Field: Ratio of Divider-Edge Glass Conductance to Center-Of-Glass Conductance
Field: Divider Solar Absorptance
Field: Divider Visible Absorptance
Field: Divider Thermal Hemispherical Emissivity
Field: Outside Reveal Solar Absorptance
Field: Inside Sill Depth
Field: Inside Sill Solar Absorptance
Field: Inside Reveal Solar Absorptance
WindowProperty:AirflowControl
Field: Name
Field: Airflow Source
Field: Airflow Destination
Field: Maximum Flow Rate
Field: Airflow Control Type
Field: Airflow Is Scheduled
Field: Airflow Multiplier Schedule Name
WindowProperty:StormWindow
Field: Window Name
Field: Storm Glass Layer Name
Field: Distance Between Storm Glass Layer and Adjacent Glass
Field: Month that Storm Glass Layer Is Put On
Field: Day of Month that Storm Glass Layer Is Put On
Field: Month that Storm Glass Layer Is Taken Off
Field: Day of Month that Storm Glass Layer Is Taken Off
Importing Windows from WINDOW program
Zone Thermal Output(s)
Zone Mean Air Temperature [C]
Zone Air Temperature [C]
Zone Mean Radiant Temperature [C]
Zone Operative Temperature [C]
Zone Air System Sensible Heating Energy [J]
Zone Air System Sensible Cooling Energy [J]
Zone Air System Sensible Heating Rate [W]
Zone Air System Sensible Cooling Rate [W]
Zone Air Humidity Ratio[kgWater/kgDryAir]
Zone Air Relative Humidity[%]
Zone Total Internal Radiant Heating Energy [J]
Zone-Total Internal Vi sible Heat Gain [J]“zone-total-internal-convective-heating-energy-j-1
Zone Total Internal Latent Gain Energy [J]
Zone Total Internal Total Heating Energy [J]
Group – Advanced Surface Concepts
SurfaceProperty:HeatTransferAlgorithm
Field: Surface Name
Field: Algorithm
SurfaceProperty:HeatTransferAlgorithm:MultipleSurface
Field: Name
Field: Surface Type
Field: Algorithm
SurfaceProperty:HeatTransferAlgorithm:SurfaceList
Field: Name
Field: Algorithm
Field: Surface Name N
SurfaceProperty:HeatTransferAlgorithm:Construction
Field: Name
Field: Algorithm
Field: Construction Name
SurfaceControl:MoveableInsulation
Field: Insulation Type
Field: Surface Name
Field: Material Name
Field: Schedule Name
SurfaceProperty:OtherSideCoefficients
Field: Name
Field: Combined Convective/Radiative Film Coefficient
Field: Constant Temperature
Field: Constant Temperature Coefficient
Field: External Dry-Bulb Temperature Coefficient
Field: Ground Temperature Coefficient
Field: Wind Speed Coefficient
Field: Zone Air Temperature Coefficient
Field: Constant Temperature Schedule Name
Field: Sinusoidal Variation of Constant Temperature Coefficient
Field: Period of Sinusoidal Variation
Field: Previous Other Side Temperature Coefficient
Field: Minimum Other Side Temperature Limit
Field: Maximum Other Side Temperature Limit
SurfaceProperty:OtherSideCoefficients Outputs
Surface Other Side Coefficients Exterior Air Drybulb Temperature [C]
SurfaceProperty:OtherSideConditionsModel
Field: Name
Field: Type of Modeling
SurfaceProperty:OtherSideConditionsModel Outputs
Surface Other Side Conditions Modeled Convection Air Temperature [C]
Surface Other Side Conditions Modeled Convection Heat Transfer Coefficient [W/m2-K]
Surface Other Side Conditions Modeled Radiation Temperature [C]
Surface Other Side Conditions Modeled Radiation Heat Transfer Coefficient [W/m2-K]
SurfaceConvectionAlgorithm:Inside:AdaptiveModelSelections
Field: Name
Field: Simple Bouyancy Vertical Wall Equation Source
Field: Simple Bouyancy Vertical Wall User Curve Name
Field: Simple Bouyancy Stable Horizontal Equation Source
Field: Simple Bouyancy Stable Horizontal Equation User Curve Name
Field: Simple Bouyancy Unstable Horizontal Equation Source
Field: Simple Bouyancy Unstable Horizontal Equation User Curve Name
Field: Simple Bouyancy Stable Tilted Equation Source
Field: Simple Bouyancy Stable Tilted Equation User Curve Name
Field: Simple Bouyancy Unstable Tilted Equation Source
Field: Simple Bouyancy Unstable Tilted Equation User Curve Name
Field: Simple Bouyancy Windows Equation Source
Field: Simple Bouyancy Windows Equation User Curve Name
Field: Floor Heat Ceiling Cool Vertical Wall Equation Source
Field: Floor Heat Ceiling Cool Vertical Wall Equation User Curve Name
Field: Floor Heat Ceiling Cool Stable Horizontal Equation Source
Field: Floor Heat Ceiling Cool Stable Horizontal Equation User Curve Name
Field: Floor Heat Ceiling Cool Unstable Horizontal Equation Source
Field: Floor Heat Ceiling Cool Unstable Horizontal Equation User Curve Name
Field: Floor Heat Ceiling Cool Heated Floor Equation Source
Field: Floor Heat Ceiling Cool Heated Floor Equation User Curve Name
Field: Floor Heat Ceiling Cool Chilled Ceiling Equation Source
Field: Floor Heat Ceiling Cool Chilled Ceiling Equation User Curve Name
Field: Floor Heat Ceiling Cool Stable Tilted Equation Source
Field: Floor Heat Ceiling Cool Stable Tilted Equation User Curve Name
Field: Floor Heat Ceiling Cool Unstable Tilted Equation Source
Field: Floor Heat Ceiling Cool Unstable Tilted Equation User Curve Name
Field: Floor Heat Ceiling Cool Window Equation Source
Field: Floor Heat Ceiling Cool Window Equation User Curve Name
Field: Wall Panel Heating Vertical Wall Equation Source
Field: Wall Panel Heating Vertical Wall Equation User Curve Name
Field: Wall Panel Heating Heated Wall Equation Source
Field: Wall Panel Heating Heated Wall Equation User Curve Name
Field: Wall Panel Heating Stable Horizontal Equation Source
Field: Wall Panel Heating Stable Horizontal Equation User Curve Name
Field: Wall Panel Heating Unstable Horizontal Equation Source
Field: Wall Panel Heating Unstable Horizontal Equation User Curve Name
Field: Wall Panel Heating Stable Tilted Equation Source
Field: Wall Panel Heating Stable Tilted Equation User Curve Name
Field: Wall Panel Heating Unstable Tilted Equation Source
Field: Wall Panel Heating Unstable Tilted Equation User Curve Name
Field: Wall Panel Heating Window Equation Source
Field: Wall Panel Heating Window Equation User Curve Name
Field: Convective Zone Heater Vertical Wall Equation Source
Field: Convective Zone Heater Vertical Wall Equation User Curve Name
Field: Convective Zone Heater Vertical Walls Near Heater Equation Source
Field: Convective Zone Heater Vertical Walls Near Heater Equation User Curve Name
Field: Convective Zone Heater Stable Horizontal Equation Source
Field: Convective Zone Heater Stable Horizontal Equation User Curve Name
Field: Convective Zone Heater Unstable Horizontal Equation Source
Field: Convective Zone Heater Unstable Horizontal Equation User Curve Name
Field: Convective Zone Heater Stable Tilted Equation Source
Field: Convective Zone Heater Stable Tilted Equation User Curve Name
Field: Convective Zone Heater Unstable Tilted Equation Source
Field: Convective Zone Heater Unstable Tilted Equation User Curve Name
Field: Convective Zone Heater Windows Equation Source
Field: Convective Zone Heater Windows Equation User Curve Name
Field: Central Air Diffuser Wall Equation Source
Field: Central Air Diffuser Wall Equation User Curve Name
Field: Central Air Diffuser Ceiling Equation Source
Field: Central Air Diffuser Ceiling Equation User Curve Name
Field: Central Air Diffuser Floor Equation Source
Field: Central Air Diffuser Floor Equation User Curve Name
Field: Central Air Diffuser Window Equation Source
Field: Central Air Diffuser Window Equation User Curve Name
Field: Mechanical Zone Fan Circulation Vertical Wall Equation Source
Field: Mechanical Zone Fan Circulation Vertical Wall Equation User Curve Name
Field: Mechanical Zone Fan Circulation Stable Horizontal Equation Source
Field: Mechanical Zone Fan Circulation Stable Horizontal Equation User Curve Name
Field: Mechanical Zone Fan Circulation Unstable Horizontal Equation Source
Field: Mechanical Zone Fan Circulation Unstable Horizontal Equation User Curve Name
Field: Mechanical Zone Fan Circulation Stable Tilted Equation Source
Field Mechanical Zone Fan Circulation Stable Tilted Equation User Curve Name
Field: Mechanical Zone Fan Circulation Unstable Tilted Equation Source
Field: Mechanical Zone Fan Circulation Unstable Tilted Equation User Curve Name
Field: Mechanical Zone Fan Circulation Window Equation Source
Field: Mechanical Zone Fan Circulation Unstable Tilted Equation User Curve Name
Field: Mixed Regime Bouyancy Assisting Flow on Walls Equation Source
Field: Mixed Regime Bouyancy Assisting Flow on Walls Equation User Curve Name
Field: Mixed Regime Bouyancy Oppossing Flow on Walls Equation Source
Field: Mixed Regime Bouyancy Oppossing Flow on Walls Equation User Curve Name
Field: Mixed Regime Stable Floor Equation Source
Field: Mixed Regime Stable Floor Equation User Curve Name
Field: Mixed Regime Unstable Floor Equation Source
Field: Mixed Regime Unstable Floor Equation User Curve Name
Field: Mixed Regime Stable Ceiling Equation Source
Field: Mixed Regime Stable Ceiling Equation User Curve Name
Field: Mixed Regime Unstable Ceiling Equation Source
Field: Mixed Regime Unstable Ceiling Equation User Curve Name
Field: Mixed Regime Window Equation Source
Field: Mixed Regime Window Equation User Curve Name
SurfaceConvectionAlgorithm:Outside:AdaptiveModelSelections
Field: Name
Field: Wind Convection Windward Vertical Wall Equation Source
Field: Wind Convection Windward Equation Vertical Wall User Curve Name
Field: Wind Convection Leeward Vertical Wall Equation Source
Field: Wind Convection Leeward Vertical Wall Equation User Curve Name
Field: Wind Convection Horizontal Roof Equation Source
Field: Wind Convection Horizontal Roof User Curve Name
Field: Natural Convection Vertical Wall Equation Source
Field: Natural Convection Vertical Wall Equation User Curve Name
Field: Natural Convection Stable Horizontal Equation Source
Field: Natural Convection Stable Horizontal Equation User Curve Name
Field: Natural Convection Unstable Horizontal Equation Source
Field: Natural Convection Unstable Horizontal Equation User Curve Name
SurfaceConvectionAlgorithm:Inside:UserCurve
Field: Name
Field: Reference Temperature for Convection Heat Transfer
Field: Hc Function of Temperature Difference Curve Name
Field: Hc Function of Temperature Difference Divided by Height Curve Name
Field: Hc Function of Air Change Rate Curve Name
Field: Hc Function of Air System Volume Flow Rate Divided by Zone Perimeter Length Curve Name
SurfaceConvectionAlgorithm:Outside:UserCurve
Field: Name
Field: Wind Speed Type for Curve
Field: Hf Function of Wind Speed Curve Name
Field: Hn Function of Temperature Difference Curve Name
Field: Hc Function of Temperature Difference Divided by Height Curve Name
SurfaceProperty:ConvectionCoefficients
Field: Surface Name
Fields (Convection Location, Type, Coefficient & Schedule Name)
Field: Convection Coefficient 1 Location
Field: Convection Coefficient 2 Location
Field: Convection Coefficient 1 Type
Field: Convection Coefficient 2 Type
Field: Convection Coefficient 1
Field: Convection Coefficient 2
Field: Convection Coefficient 1 Schedule Name
Field: Convection Coefficient 2 Schedule Name
Field: Convection Coefficient 1 User Curve Name
Field: Convection Coefficient 2 User Curve Name
SurfaceProperty:ConvectionCoefficients:MultipleSurface
Field: Surface Type
Fields (Convection Location, Type, Coefficient & Schedule Name)
Field: Convection Coefficient 1 Location
Field: Convection Coefficient 2 Location
Field: Convection Coefficient 1 Type
Field: Convection Coefficient 2 Type
Field: Convection Coefficient 1
Field: Convection Coefficient 2
Field: Convection Coefficient 1 Schedule Name
Field: Convection Coefficient 2 Schedule Name
Field: Convection Coefficient 1 User Curve Name
Field: Convection Coefficient 2 User Curve Name
Convection Coefficient Application Hierarchy
Convection Coefficients Outputs
Surface Inside Face Convection Classification Index
Surface Inside Face Convection Model Equation Index
Surface Inside Face Convection Reference Air Index
Surface Outside Face Convection Classification Index
Surface Outside Face Forced Convection Model Equation Index
Surface Outside Face Natural Convection Model Equation Index
SurfaceProperties:VaporCoefficients
Field: Surface Name
Field: Constant External Vapor Transfer Coefficient
Field: External Vapor Coefficient Value
Field: Constant Internal vapor Transfer Coefficient
Field: Internal Vapor Coefficient Value
SurfaceProperty:ExteriorNaturalVentedCavity
Field: Name
Field: Boundary Conditions Model Name
Field: Area Fraction of Openings
Field: Thermal Emissivity of Exterior Baffle Material
Field: Solar Absorptivity of Exterior Baffle
Field: Height Scale for Buoyancy-Driven Ventilation
Field: Effective Thickness of Cavity Behind Exterior Baffle
Field: Ratio of Actual Surface Area to Projected Surface Area
Field: Roughness of Exterior Surface
Field: Effectiveness for Perforations with Respect to Wind
Field: Discharge Coefficient for Openings with Respect to Buoyancy Driven Flow
Field(s): Surface <1 thru x> Name
SurfaceProperty:ExteriorNaturalVentedCavity Outputs
Surface Exterior Cavity Air Drybulb Temperature [C]
Surface Exterior Cavity Baffle Surface Temperature [C]
Surface Exterior Cavity Total Natural Ventilation Mass Flow Rate [kg/s]
Surface Exterior Cavity Natural Ventilation from Wind Mass Flow Rate [kg/s]
Surface Exterior Cavity Natural Ventilation from Buoyancy Mass Flow Rate [kg/s]
GeometryTransform
Field: Plane of Transform
Field: Current Aspect Ratio
Field: New Aspect Ratio
Zone Property View Factors
Approximate Option
User Input View Factors
ZoneProperty:UserViewFactors:bySurfaceName
Field: Zone Name
Field: From Surface 1
Field: To Surface 1
Field: Factor 1
Group – Detailed Ground Heat Transfer
Detailed Ground Heat Transfer
GroundHeatTransfer:Control
Field: Name
Field: Run Basement Preprocessor
Field: Run Slab Preprocessor
Group – Room Air Models
Room Air Models
RoomAirModelType
Field: Name
Field: Zone Name
Field: Room-Air Modeling Type
Field: Air Temperature Coupling Strategy
RoomAir:TemperaturePattern:UserDefined
Field: Name
Field: Zone Name
Field: Availability Schedule Name
Field: Pattern Control Schedule Name
RoomAir:TemperaturePattern:ConstantGradient
Field: Name
Field: Control Integer for Pattern Control Schedule Name
Field: Thermostat Offset
Field: Return Air Offset
Field: Exhaust Air Offset
Field: Temperature Gradient
RoomAir:TemperaturePattern:TwoGradient
Field: Name
Field: Control Integer for Pattern Control Schedule Name
Field: Thermostat Height
Field: Return Air Height
Field: Exhaust Air Height
Field: Temperature Gradient Lower Bound
Field: Temperature Gradient Upper Bound
Field: Gradient Interpolation Mode
Field: Upper Temperature Bound
Field: Lower Temperature Bound
Field: Upper Heat Rate Bound
Field: Lower Heat Rate Bound
RoomAir:TemperaturePattern:NondimensionalHeight
Field: Name
Field: Control Integer for Pattern Control Schedule Name
Field: Thermostat Offset
Field: Return Air Offset
Field: Exhaust Air Offset
Field Set Zeta and Temperature Difference
Field: Pair <#> Zeta non-dimensional Height
Field: Pair <#> Delta Adjacent Air Temperature
RoomAir:TemperaturePattern:SurfaceMapping
Field: Name
Field: Control Integer for Pattern Control Schedule Name
Field: Thermostat Offset
Field: Return Air Offset
Field: Exhaust Air Offset
Field Set: Surface Name, Temperature Difference
Fields (6 and on): Pairs of Surface Names and Temperature Differences
Field: Surface Name Pair <#>
Field: Delta Adjacent Air Temperature Pair <#>
RoomAir:Node
Field: Name
Field: Node Type
Field: Zone Name
Field: Height of Nodal Control Volume Center
Field: Surface <#> Name
RoomAirSettings:OneNodeDisplacementVentilation
Field: Zone Name
Field: Fraction of Convective Internal Loads Added to Floor Air
Field: Fraction of Infiltration Internal Loads Added to Floor Air
RoomAirSettings:ThreeNodeDisplacementVentilation
Field: Zone Name
Field: Gain Distribution Schedule Name
Field: Number of Plumes per Occupant
Field: Thermostat Height
Field: Comfort Height
Field: Temperature Difference Threshold for Reporting
RoomAirSettings:CrossVentilation
Field: Zone Name
Field: Gain Distribution Schedule Name
Field: Airflow Region Used for Thermal Comfort Evaluation
RoomAirSettings:UnderFloorAirDistributionInterior
Field: Zone Name
Field: Number of Diffusers
Field: Power per Plume
Field: Design Effective Area of Diffuser
Field: Diffuser Slot Angle from Vertical
Field: Thermostat Height
Field: Comfort Height
Field: Temperature Difference Threshold for Reporting
Field: Diffuser Type
Field: Transition Height
Field: Coefficient A
Field: Coefficient B
Field: Coefficient C
Field: Coefficient D
Field: Coefficient E
RoomAirSettings:UnderFloorAirDistributionExterior
Field: Zone Name
Field: Number of Diffusers
The total number of diffusers in this zone. This field can allowed to Autocalculate (in which case it is set to the design occupancy level; i.e., number of people). If the design occupancy is low or zero but there are still heat sources that could generate buoyancy driven plumes, the user should input a value based on the design supply air flow rate of the zone and the design flow rate of an individual diffuser. In the absence of any other information, divide the zone area by 100 ft2. The default for this field is Autocalculate.
Field: Power per Plume
The power in watts incorporated in a buoyancy driven thermal plume. Normally we assume all the loads of a workstation create a single plume so that this represents the convective heat gain from a workstation – 1 person, 1 computer terminal, plus any task lighting. A typical value would be 220 watts. However, the model assumes an “equivalent” plume derived from the zone extraction rate normalized to the number of workstations/occupants. This field should be allowed to default – the program will calculate a value based upon the occupancy and the extraction rate. The default is Autocalculate.
Field: Design Effective Area of Diffuser
Field: Diffuser Slot Angle from Vertical
Field: Thermostat Height
Field: Comfort Height
Field: Temperature Difference Threshold for Reporting
Field: Diffuser Type
Field: Transition Height
Field: Coefficient A
Field: Coefficient B
Field: Coefficient C
Field: Coefficient D
Field: Coefficient E
Room Air Model Outputs
RoomAir:TemperaturePattern:TwoGradient Outputs
Room Air Zone Vertical Temperature Gradient [K/m]
Mundt Model / OneNodeDisplacementVentilation Outputs
Room Air Node Air Temperature [C]
ThreeNodeDisplacementVentilation Outputs
Room Air Zone Mixed Subzone Temperature [C]
Room Air Zone Occupied Subzone Temperature [C]
Room Air Zone Floor Subzone Temperature [C]
Room Air Zone Transition Height [m]
Room Air Zone Recommended Minimum Flow Fraction []
Room Air Zone Is Mixed Status []
Room Air Zone Average Temperature Gradient [K/m]
Room Air Zone Maximum Temperature Gradient [K/m]
Room Air Zone Thermal Comfort Effective Air Temperature [C]
Room Air Zone Thermostat Temperature [C]
CrossVentilation Model Outputs
Room Air Zone Jet Region Temperature [C]
Room Air Zone Recirculation Region Temperature [C]
Room Air Zone Jet Region Average Air Velocity [m/s]
Room Air Zone Recirculation Region Average Air Velocity [m/s]
Room Air Zone Inflow Opening Area [m2]
Room Air Zone Room Length [m]
Room Air Zone Recirculation and Inflow Rate Ratio []
Room Air Zone Is Mixing Status []
Room Air Zone Is Recirculating Status []
UnderFloorAirDistributionInterior/Exterior Model Outputs
Room Air Zone Mixed Subzone Temperature [C]
Room Air Zone Occupied Subzone Temperature [C]“room-air-zone-transition-height-m-1
Room Air Zone Is Mixed Status []
Room Air Zone Average Temperature Gradient [K/m]
Room Air Zone Effective Comfort Air Temperature [C]
Room Air Zone Thermostat Temperature [C]
Room Air Zone Transition Height Gamma Value []
Room Air Zone Plume Heat Transfer Rate [W]
Room Air Zone Window Plume Heat Transfer Rate [W]
Room Air Zone Temperature Stratification Fraction []
Group – Internal Gains (People, Lights, Other internal zone equipment)
People
Field: Name
Field: Zone or ZoneList Name
Field: Number of People Schedule Name
Field: Number of People Calculation Method
Field: Number of People
Field: People per Zone Floor Area
Field: Zone Floor Area per Person
Field: Fraction Radiant
Field: Sensible Heat Fraction
Field: Activity Level Schedule Name
Field: Carbon Dioxide Generation Rate
Field: Enable ASHRAE 55 comfort warnings
Field: Mean Radiant Temperature Calculation Type
Field: Surface Name/Angle Factor List Name
Field: Work Efficiency Schedule Name
Field: Clothing Insulation Schedule Name
Field: Air Velocity Schedule Name
Field: Thermal Comfort Model Type (up to 5 allowed)
People Outputs
People Occupant Count []
People Radiant Heating Rate [W]
People Radiant Heating Energy [J]
People Convective Heating Rate [W]
People Convective Heating Energy [J]
People Latent Gain Rate [W]
People Latent Gain Energy [J]
People Sensible Heating Rate [W]
People Sensible Heating Energy [J]
People Total Heating Rate [W]
People Total Heating Energy [J]
People Air Temperature [C]
People Air Relative Humidity [%]
Zone People Occupant Count []
Zone People Radiant Heating Rate [W]
Zone People Radiant Heating Energy [J]
Zone People Convective Heating Rate [W]
Zone People Convective Heating Energy [J]
Zone People Latent Gain Rate [W]
Zone People Latent Gain Energy [J]
Zone People Sensible Heating Rate [W]
Zone People Sensible Heating Energy [J]
Zone People Total Heating Rate [W]
Zone People Total Heating Energy [J]
Zone Thermal Comfort Mean Radiant Temperature [C]
Zone Thermal Comfort Operative Temperature [C]
Zone Thermal Comfort Fanger Model PMV []
Zone Thermal Comfort Fanger Model PPD [%]
Zone Thermal Comfort Clothing Surface Temperature [C]
Zone Thermal Comfort Pierce Model Effective Temperature PMV []
Zone Thermal Comfort Pierce Model Standard Effective Temperature PMV []
Zone Thermal Comfort Pierce Model Discomfort Index []
Zone Thermal Comfort Pierce Model Thermal Sensation Index []
Zone Thermal Comfort KSU Model Thermal Sensation Vote []
Zone Thermal Comfort ASHRAE 55 Adaptive Model 90% Acceptability Status []
Zone Thermal Comfort ASHRAE 55 Adaptive Model 80% Acceptability Status [ ]
Zone Thermal Comfort ASHRAE 55 Adaptive Model Running Average Outdoor Air Temperature [C]
Zone Thermal Comfort ASHRAE 55 Adaptive Model Temperature [C]
Zone Thermal Comfort CEN 15251 Adaptive Model Category I Status
Zone Thermal Comfort CEN 15251 Adaptive Model Category II Status
Zone Thermal Comfort CEN 15251 Adaptive Model Category III Status
Zone Thermal Comfort CEN 15251 Adaptive Model Running Average Outdoor Air Temperature
Zone Thermal Comfort CEN 15251 Adaptive Model Temperature
Simplified ASHRAE 55-2004 Graph Related Outputs
Zone Thermal Comfort ASHRAE 55 Simple Model Summer Clothes Not Comfortable Time[hr]
Zone Thermal Comfort ASHRAE 55 Simple Model Winter Clothes Not Comfortable Time[hr]
Zone Thermal Comfort ASHRAE 55 Simple Model Summer or Winter Clothes Not Comfortable Time[hr]
Facility Thermal Comfort ASHRAE 55 Simple Model Summer Clothes Not Comfortable Time[hr]
Facility Thermal Comfort ASHRAE 55 Simple Model Winter Clothes Not Comfortable Time [hr]
Facility Thermal Comfort ASHRAE 55 Simple Model Summer Clothes Not Comfortable Time [hr]
Simplified ASHRAE 55 Warnings
ComfortViewFactorAngles
Field: Name
Field: Zone Name
Field: Surface <#> Name
Field: Angle Factor <#>
Lights
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Lighting Level
Field: Watts per Zone Floor Area
Field: Watts per Person
Heat Gains from Lights:
Field: Return Air Fraction
Field: Fraction Radiant
Field: Fraction Visible
Field: Fraction Replaceable
Field: End-Use Subcategory
Field: Return Air Fraction Calculated from Plenum Temperature
Field: Return Air Fraction Function of Plenum Temperature Coefficient 1
Field: Return Air Fraction Function of Plenum Temperature Coefficient 2
Lights Report Outputs
Lights Electric Power [W]
Lights Radiant Heating Rate [W]
Lights Radiant Heating Energy [J]
Lights Visible Radiation Heating Rate [W]
Lights Visible Radiation Heating Energy [J]
Lights Convective Heating Rate [W]
Lights Convective Heating Energy [J]
Lights Return Air Heating Rate [W]
Lights Return Air Heating Energy [J]
Lights Total Heating Rate [W]
Lights Total Heating Energy [J]
Lights Electric Energy [J]
Zone Lights Electric Power [W]
Zone Lights Radiant Heating Rate [W]
Zone Lights Radiant Heating Energy [J]
Zone Lights Visible Radiation Heating Rate [W]
Zone Lights Visible Radiation Heating Energy [J]
Zone Lights Convective Heating Rate [W]
Zone Lights Convective Heating Energy [J]
Zone Lights Return Air Heating Rate [W]
Zone Lights Return Air Heating Energy [J]
Zone Lights Total Heating Rate [W]
Zone Lights Total Heating Energy [J]
Zone Lights Electric Energy [J]
Meters for Lights Outputs
ElectricEquipment
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Design Level
Field: Watts per Zone Floor Area
Field: Watts per Person
Heat Gains from Electric Equipment:
Field: Fraction Latent
Field: Fraction Radiant
Field: Fraction Lost
Field: End-Use Subcategory
GasEquipment
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Design Level
Field: Power per Zone Floor Area
Field: Power per Person
Heat Gains from Gas Equipment:
Field: Fraction Latent
Field: Fraction Radiant
Field: Fraction Lost
Field: Carbon Dioxide Generation Rate
Field: End-Use Subcategory
HotWaterEquipment
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Design Level
Field: Power per Zone Floor Area
Field: Power per Person
Heat Gains from Hot Water Equipment:
Field: Fraction Latent
Field: Fraction Radiant
Field: Fraction Lost
Field: End-Use Subcategory
SteamEquipment
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Design Level
Field: Power per Zone Floor Area
Field: Power per Person
Heat Gains from Steam Equipment:
Field: Fraction Latent
Field: Fraction Radiant
Field: Fraction Lost
Field: End-Use Subcategory
OtherEquipment
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Design Level Calculation Method
Field: Design Level
Field: Power per Zone Floor Area
Field: Power per Person
Heat Gains/Losses from Other Equipment:
Field: Fraction Latent
Field: Fraction Radiant
Field: Fraction Lost
Electric, Gas, Other, HotWater, Steam Equipment Outputs
Electric Equipment Electric Power [W]
Gas Equipment Gas Rate [W]
Hot Water Equipment District Heating Rate [W]
Hot Water Equipment District Heating Energy [J]
Steam Equipment District Heating Energy [J]
Steam Equipment District Heating Rate [W]
Electric Equipment Radiant Heating Rate [W]
Electric Equipment Radiant Heating Energy [J]
Gas Equipment Radiant Heating Rate [W]
Gas Equipment Radiant Heating Energy [J]
Hot Water Equipment Radiant Heating Rate [W]
Hot Water Equipment Radiant Heating Energy [J]
Steam Equipment Radiant Heating Rate [W]
Steam Equipment Radiant Heating Energy [J]
Other Equipment Radiant Heating Rate [W]
Other Equipment Radiant Heating Energy [J]
Electric Equipment Convective Heating Rate [W]
Electric Equipment Convective Heating Energy [J]
Gas Equipment Convective Heating Rate [W]
Gas Equipment Convective Heating Energy [J]
Hot Water Equipment Convective Heating Rate [W]
Hot Water Equipment Convective Heating Energy [J]
Steam Equipment Convective Heating Rate [W]
Steam Equipment Convective Heating Energy [J]
Other Equipment Convective Heating Rate [W]
Other Equipment Convective Heating Energy [J]
Electric Equipment Latent Gain Rate [W]
Electric Equipment Latent Gain Energy [J]
Gas Equipment Latent Gain Rate [W]
Gas Equipment Latent Gain Energy [J]
Hot Water Equipment Latent Gain Rate [W]
Hot Water Equipment Latent Gain Energy [J]
Steam Equipment Latent Gain Rate [W]
Steam Equipment Latent Gain Energy [J]
Other Equipment Latent Gain Rate [W]
Other Equipment Latent Gain Energy [J]
Electric Equipment Lost Heat Rate [W]
Electric Equipment Lost Heat Energy [J]
Gas Equipment Lost Heat Rate [W]
Gas Equipment Lost Heat Energy [J]
Hot Water Equipment Lost Heat Rate [W]
Hot Water Equipment Lost Heat Energy [J]
Steam Equipment Lost Heat Rate [W]
Steam Equipment Lost Heat Energy [J]
Other Equipment Lost Heat Rate [W]
Other Equipment Lost Heat Energy [J]
Electric Equipment Total Heating Rate [W]
Electric Equipment Total Heating Energy [J]
Gas Equipment Total Heating Rate [W]
Gas Equipment Total Heating Energy [J]
Hot Water Equipment Total Heating Rate [W]
Hot Water Equipment Total Heating Energy [J]
Steam Equipment Total Heating Rate [W]
Steam Equipment Total Heating Energy [J]
Other Equipment Total Heating Rate [W]
Other Equipment Total Heating Energy [J]
Electric Equipment Electric Energy [J]
Gas Equipment Gas Energy [J]
Hot Water Equipment Purchased Heating Consumption [J]
Steam Equipment Purchased Heating Consumption [J]
Zone Electric Equipment Electric Power [W]
Zone Gas Equipment Gas Rate [W]
[Zone Hot Water Equipment District Heating Rate W]](page-015.html#zone-hot-water-equipment-district-heating-rate-w)
Zone Steam Equipment District Heating Rate [W]
Zone Electric Equipment Radiant Heating Rate [W]
Zone Electric Equipment Radiant Heating Energy [J]
Zone Gas Equipment Radiant Heating Rate [W]
Zone Gas Equipment Radiant Heating Energy [J]
Zone Hot Water Equipment Radiant Heating Rate [W]
Zone Hot Water Equipment Radiant Heating Energy [J]
Zone Steam Equipment Radiant Heating Rate [W]
Zone Steam Equipment Radiant Heating Energy [J]
Zone Other Equipment Radiant Heating Rate [W]
Zone Other Equipment Radiant Heating Energy [J]
Zone Electric Equipment Convective Heating Rate [W]
Zone Electric Equipment Convective Heating Energy [J]
Zone Gas Equipment Convective Heating Rate [W]
Zone Gas Equipment Convective Heating Energy [J]
Zone Hot Water Equipment Convective Heating Rate [W]
Zone Hot Water Equipment Convective Heating Energy [J]
Zone Steam Equipment Convective Heating Rate [W]
Zone Steam Equipment Convective Heating Energy [J]
Zone Other Equipment Convective Heating Rate [W]
Zone Other Equipment Convective Heating Energy [J]
Zone Electric Equipment Latent Gain Rate [W]
Zone Electric Equipment Latent Gain Energy [J]
Zone Gas Equipment Latent Gain Rate [W]
Zone Gas Equipment Latent Gain Energy [J]
Zone Hot Water Equipment Latent Gain Rate [W]
Zone Hot Water Equipment Latent Gain Energy [J]
Zone Steam Equipment Latent Gain Rate [W]
Zone Steam Equipment Latent Gain Energy [J]
Zone Other Equipment Latent Gain Rate [W]
Zone Other Equipment Latent Gain Energy [J]
Zone Electric Equipment Lost Heat Rate [W]
Zone Electric Equipment Lost Heat Energy [J]
Zone Gas Equipment Lost Heat Rate [W]
Zone Gas Equipment Lost Heat Energy [J]
Zone Hot Water Equipment Lost Heat Rate [W]
Zone Hot Water Equipment Lost Heat Energy [J]
Zone Steam Equipment Lost Heat Rate [W]
Zone Steam Equipment Lost Heat Energy [J]
Zone Other Equipment Lost Heat Rate [W]
Zone Other Equipment Lost Heat Energy [J]
Zone Electric Equipment Total Heating Rate [W]
Zone Electric Equipment Total Heating Energy [J]
Zone Gas Equipment Total Heating Rate [W]
Zone Gas Equipment Total Heating Energy [J]
Zone Hot Water Equipment Total Heating Rate [W]
Zone Hot Water Equipment Total Heating Energy [J]
Zone Steam Equipment Total Heating Rate [W]
Zone Steam Equipment Total Heating Energy [J]
Zone Other Equipment Total Heating Rate [W]
Zone Other Equipment Total Heating Energy [J]
Zone Electric Equipment Electric Energy [J]
Zone Gas Equipment Gas Energy [J]
Zone Hot Water Equipment District Heating Energy [J]
Zone Steam Equipment District Heating Energy [J]
ZoneContaminantSourceAndSink:CarbonDioxide
Field: Name
Field: Zone Name
Field: Design Generation Rate
Field: Schedule Name
ZoneContaminantSourceAndSink:CarbonDioxide Outputs
Contaminant Source or Sink CO2 Gain Volume Flow Rate [m3/s]
Zone Contaminant Source or Sink CO2 Gain Volume Flow Rate [m3/s]
ZoneContaminantSourceAndSink:GenericContaminant:Constant
Field: Name
Field: Zone Name
Field: Maximum Generation Rate
Field: Generation Schedule Name
Field: Design Removal Coefficient
Field: Removal Schedule Name
ZoneContaminantSourceAndSink:GenericContaminant:Constant Outputs
Generic Air Contaminant Constant Source Generation Volume Flow Rate [m3/s]
SurfaceContaminantSourceAndSink:GenericContaminant:PressureDriven
Field: Name
Field: Surface Name
Field: Design Generation Rate Coefficient
Field: Generation Schedule Name
SurfaceContaminantSourceAndSink:GenericContaminant:PressureDriven Outputs
Generic Air Contaminant Pressure Driven Generation Volume Flow Rate [m3/s]
ZoneContaminantSourceAndSink:GenericContaminant:CutoffModel
Field: Name
Field: Zone Name
Field: Design Generation Rate
Field: Generation Schedule Name
Field: Cutoff Concentration
ZoneContaminantSourceAndSink:GenericContaminant:CutoffModel Outputs
Generic Air Contaminant Cutoff Model Generation Volume Flow Rate [m3/s]
ZoneContaminantSourceAndSink:GenericContaminant:DecaySource
Field: Name
Field: Zone Name
Field: Initial Generation Rate
Field: Generation Schedule Name
Field: Decay Time Constant
ZoneContaminantSourceAndSink:GenericContaminant:DecaySource Outputs
Generic Air Contaminant Decay Model Generation Volume Flow Rate [m3/s]
Generic Air Contaminant Decay Model Generation Emission Start Elapsed Time [s]
SurfaceContaminantSourceAndSink:GenericContaminant:BoudaryLayerDiffusion
Field: Name
Field: Surface Name
Field: Film Transfer Coefficient
Field: Henry Partition Coefficient
SurfaceContaminantSourceAndSink:GenericContaminant:BoundaryLayerDiffusion Outputs
Generic Air Contaminant Boundary Layer Diffusion Generation Volume Flow Rate [m3/s]
Generic Air Contaminant Boundary Layer Diffusion Inside Face Concentration [ppm]
SurfaceContaminantSourceAndSink:GenericContaminant:DepositionVelocitySink
Field: Name
Field: Surface Name
Field: Deposition Velocity
Field: Removal Schedule Name
SurfaceContaminantSourceAndSink:GenericContaminant:DepositionVelocitySink Outputs
Generic Air Contaminant Deposition Velocity Removal Volume Flow Rate [m3/s]
ZoneContaminantSourceAndSink:GenericContaminant:DepositionRateSink
Field: Name
Field: Zone Name
Field: Deposition Rate
Field: Removal Schedule Name
ZoneContaminantSourceAndSink:GenericContaminant:DepositionRateSink Outputs
Generic Air Contaminant Deposition Rate Removal Volume Flow Rate [m3/s]
ZoneBaseboard:OutdoorTemperatureControlled
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Capacity at Low Temperature
Field: Low Temperature
Field: Capacity at High Temperature
Field: High Temperature
Field: Fraction Radiant
Field: End-Use Subcategory
ZoneBaseboard:OutdoorTemperatureControlled Output
Baseboard Electric Power [W]
Baseboard Electric Energy [J]
Baseboard Radiant Heating Rate [W]
Baseboard Radiant Heating Energy [J]
Baseboard Convective Heating Rate [W]
Baseboard Convective Heating Energy [J]
Baseboard Total Heating Rate [W]
Baseboard Total Heating Energy [J]
Zone Baseboard Electric Pow er [W]“zone-baseboard-electric-energy-j
Zone Baseboard Radiant Heating Rate [W]
Zone Baseboard Radiant Heating Energy [J]
Zone Baseboard Convective Heating Rate [W]
Zone Baseboard Convective Heating Energy [J]
Zone Baseboard Total Heating Rate [W]
Zone Baseboard Total Heating Energy [J]
Meters for Equipment Outputs
Group – Daylighting
Daylighting:Controls
Field: Zone name
Field: Total Daylighting Reference Points
Fields: (X,Y,Z) of First Reference Point
Fields: (X,Y,Z) of Second Reference Point
Field: Fraction of Zone Controlled by First Reference Point
Field: Fraction of Zone Controlled by Second Reference Point
Field: Illuminance SetPoint at First Reference Point
Field: Illuminance SetPoint at Second Reference Point
Field: Lighting Control Type
Field: Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis
Field: Maximum Allowable Discomfort Glare Index
Field: Minimum Input Power Fraction for Continuous Dimming Control
Field: Minimum Light Output Fraction for Continuous Dimming Control
Field: Number of Stepped Control Steps
Field: Probability Lighting will be Reset When Needed in Manual Stepped Control
Field: Availability Schedule Name
Guidelines for Daylighting Modeling (Detailed Method)
Use of Window Multipliers
Use of Zone Multipliers
Thermal Zoning for Daylighting
Multiple Lighting Zones
Fins, Overhangs and Other Exterior Obstructions
Interior Obstructions
Double Façades: Daylighting through Interior Windows
Interior Window Daylighting Configurations that EnergyPlus Can Calculate
Interior Window Daylighting Configurations that EnergyPlus Cannot Calculate
Restrictions on Shading Devices
DElight Daylighting Method
Daylighting:DELight:Controls
Field: Name
Field: Zone Name
Field: Lighting Control Type
Field: Minimum Input Power Fraction for Continuous Dimming Control
Field: Minimum Light Output Fraction for Continuous Dimming Control
Field: Number of Steps (Excluding Off) for Stepped Control
Field: Probability Lighting Will Be Reset When Needed in Manual Stepped Control
Field: Gridding Resolution
Daylighting:DELight:ReferencePoint
Field: Name
Field: DElight Name
Fields: (X,Y,Z) of Reference Point
Field: Fraction of Zone Controlled by Reference Point
Field: Illuminance Setpoint at Reference Point
Daylighting:DELight:ComplexFenestration
Field: User Name
Field: Complex Fenestration Type
Field: Building Surface Name
Field: Window Name
Field: Fenestration Rotation
DElight Output
Daylighting Reference Point Illuminance [lux]
Daylighting Lighting Power Multiplier []
Daylighting Output
Site Exterior Beam Normal Illuminance [lux]
Site Exterior Horizontal Beam Illuminance [lux]
Site Exterior Horizontal Sky Illuminance [lux]
Site Beam Solar Radiation Luminous Efficacy [lum/W]
Site Sky Diffuse Solar Radiation Luminous Efficacy [lum/W]
Site Daylighting Model Sky Clearness [ ]
Site Daylighting Model Sky Brightness [ ]
Daylighting Window Reference Point 1 View Luminance [cd/m2]
Daylighting Window Reference Point 1 Illuminance [lux]
Daylighting Reference Point 1 Illuminance [lux]
Daylighting Reference Point 1 Glare Index []
Daylighting Reference Point 1 Glare Index Setpoint Exceeded Time [hr]
Daylighting Reference Point 1 Daylight Illuminance Setpoint Exceeded Time [hr]
Daylighting Reference Point 2 Illuminance [lux]
Daylighting Window Reference Point 2 View Luminance [cd/m2]
Daylighting Window Reference Point 2 Illuminance [lux]
Daylighting Reference Point 2 Glare Index []
Daylighting Reference Point 2 Glare Index Setpoint Exceeded Time [hr]
Daylighting Reference Point 2 Daylight Illuminance Setpoint Exceeded Time [hr]
Daylighting Lighting Power Multiplier []
Output:IlluminanceMap
Field: Name
Field: Zone Name
Field: Z Height
Field: X Minimum Coordinate
Field: X Maximum Coordinate
Field: Number of X Grid Points
Field: Y Minimum Coordinate
Field: Y Maximum Coordinate
Field: Number of Y Grid Points
OutputControl:IlluminanceMap:Style
Field: Column Separator
Daylighting Devices
DaylightingDevice:Tubular
Field: Name
Field: Dome Name
Field: Diffuser Name
Field: Construction Name
Field: Diameter
Fie ld: Total Length”field-effective-thermal-resistance
Field: Transition Zone<#> Name
Field: Transition Zone <#> Length
Tubular Daylighting Device Output
Tubular Daylighting Device Beam Solar Transmittance []
Tubular Daylighting Device Beam Visible Transmittance []
Tubular Daylighting Device Diffuse Solar Transmittance []
Tubular Daylighting Device Diffuse Visible Transmittance []
Tubular Daylighting Device Heat Gain Rate [W]
Tubular Daylighting Device Heat Loss Rate [W]
Tubular Daylighting Device Pipe Absorbed Solar Radiation Rate [W]
Tubular Daylighting Device Transmitted Solar Radiation Rate [W]
DaylightingDevice:Shelf
Field: Name
Field: Window Name
Field: Inside Shelf Name
Field: Outside Shelf Name
Field: Outside Shelf Construction Name
Field: View Factor To Outside Shelf
Shelf Daylighting Device Output
DaylightingDevice:LightWell
Field: Exterior Window Name
Field: Height of Well
Field: Perimeter of Bottom of Well
Field: Area of Bottom of Well
Field: Visible Reflectance of Well Walls
Daylighting Modeling Options
Group – Exterior Energy Use Equipment
Exterior:Lights
Field: Name
Field: Schedule Name
Field: Design Level
Field: Control Option
Field: End-Use Subcategory
Exterior Lights Outputs
Exterior Lights Electric Power [W]
Exterior Lights Electric Energy [J]
Exterior:FuelEquipment
Field: Name
Field: Fuel Use Type
Field: Schedule Name
Field: Design Level
Field: End-Use Subcategory
Exterior:WaterEquipment
Field: Name
Field: FuelUseType
Field: Schedule Name
Field: Design Level
Field: End-Use Subcategory
Exterior Fuel Equipment, Exterior Water Equipment Outputs
Exterior Equipment Fuel Rate [W]
Exterior Equipment Energy [J]
Exterior Equipment Water Volume Flow Rate [m3/s]
Exterior Equipment Water Volume [m3]
Group – Airflow
ZoneInfiltration:DesignFlowRate
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Flow Rate Calculation Method
Field: Design Flow Rate
Field: Flow per Zone Floor Area
Field: Flow per Exterior Surface Area
Field: Air Changes per Hour
Field: Constant Term Coefficient
Field: Temperature Term Coefficient
Field: Velocity Term Coefficient
Field: Velocity Squared Term Coefficient
ZoneInfiltration:EffectiveLeakageArea
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Effective Air Leakage Area
Field: Stack Coefficient
Field: Wind Coefficient
ZoneInfiltration:FlowCoefficient
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Flow Coefficient
Field: Stack Coefficient
Field: Pressure Exponent
Field: Wind Coefficient
Field: Shelter Factor
ZoneInfiltration Outputs
Zone Infiltration Sensible Heat Loss Energy [J]
Zone Infiltration Sensible Heat Gain Energy [J]
Zone Infiltration Latent Heat Loss Energy [J]
Zone Infiltration Latent Heat Gain Energy [J]
Zone Infiltration Total Heat Loss Energy [J]
Zone Infiltration Total Heat Gain Energy [J]
Zone Infiltration Current Density Volume [m3]
Zone Infiltration Current Density Volume Flow Rate [m3/s]
Zone Infiltration Standard Density Volume [m3]
Zone Infiltration Standard Density Volume Flow Rate [m3/s]
Zone Infiltration Mass [kg]
Zone Infiltration Air Change Rate [ach]
ZoneVentilation:DesignFlowRate
Field: Name
Field: Zone or ZoneList Name
Field: Schedule Name
Field: Design Flow Rate Calculation Method
Field: Design Flow Rate
Field: Flow Rate per Zone Floor Area
Field: Flow Rate per Person
Field: Air Changes per Hour
Field: Ventilation Type
Field: Fan Pressure Rise
Field: Fan Total Efficiency
Field: Constant Term Coefficient
Field: Temperature Term Coefficient
Field: Velocity Term Coefficient
Field: Velocity Squared Term Coefficient
Field: Minimum Indoor Temperature
Field: Minimum Indoor Temperature Schedule Name
Field: Maximum Indoor Temperature
Field: Maximum Indoor Temperature Schedule Name
Field: Delta Temperature
Field: Delta Temperature Schedule Name
Field: Minimum Outdoor Temperature
Field: Minimum Outdoor Temperature Schedule Name
Field: Maximum Outdoor Temperature
Field: Maximum Outdoor Temperature Schedule Name
Field: Maximum Wind Speed
ZoneVentilation:WindandStackOpenArea
Field: Name
Field: Zone Name
Field: Opening Area
Field: Opening Area Fraction Schedule Name
Field: Opening Effectiveness
Field: Effective Angle
Field: Height Difference
Field: Discharge Coefficient for Opening
Field: Minimum Indoor Temperature
Field: Minimum Indoor Temperature Schedule Name
Field: Maximum Indoor Temperature
Field: Maximum Indoor Temperature Schedule Name
Field: Delta Temperature
Field: Delta Temperature Schedule Name
Field: Minimum Outdoor Temperature
Field: Minimum Outdoor Temperature Schedule Name
Field: Maximum Outdoor Temperature
Field: Maximum Outdoor Temperature Schedule Name
Field: Maximum Wind Speed
ZoneVentilation Outputs
Zone Ventilation Sensible Heat Loss Energy [J]
Zone Ventilation Sensible Heat Gain Energy [J]
Zone Ventilation Latent Heat Loss Energy [J]
Zone Ventilation Latent Heat Gain Energy [J]
Zone Ventilation Total Heat Loss Energy [J]
Zone Ventilation Total Heat Gain Energy [J]
Zone Ventilation Current Density Volume [m3]
Zone Ventilation Current Density Volume Flow Rate [m3/s]
Zone Ventilation Standard Density Volume [m3]
Zone Ventilation Standard Density Volume Flow Rate [m3/s]
Zone Ventilation Mass [kg]
Zone Ventilation Air Change Rate [ach]
Zone Ventilation Fan Electric Energy [J]
Zone Ventilation Air Inlet Temperature [C]
ZoneAirBalance:OutdoorAir
Field: Name
Field: Zone Name
Field: Air Balance Method
Field: Induced Outdoor Air Due to Unbalanced Duct Leakage
Field: Induced Outdoor Air Schedule Name
ZoneAirBalance:OutdoorAir Outputs
Zone Combined Outdoor Air Sensible Heat Loss Energy [J]
Zone Combined Outdoor Air Sensible Heat Gain Energy [J]
Zone Combined Outdoor Air Latent Heat Loss Energy [J]
Zone Combined Outdoor Air Latent Heat Gain Energy [J]
Zone Combined Outdoor Air Total Heat Loss Energy [J]
Zone Combined Outdoor Air Total Heat Gain Energy [J]
Zone Combined Outdoor Air Current Density Volume [m3]
Zone Combined Outdoor Air Current Density Volume Flow Rate [m3/s]
Zone Combined Outdoor Air Standard Density Volume [m3]
Zone Combined Outdoor Air Standard Density Volume Flow Rate [m3/s]
Zone Combined Outdoor Air Mass [kg]
Zone Combined Outdoor Air Changes per Hour [ach]
Zone Combined Outdoor Air Fan Electric Energy [J]
ZoneMixing
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Design Flow Rate Calculation Method
Field: Design Flow Rate
Field: Flow Rate per Zone Floor Area
Field: Flow Rate per Person
Field: Air Changes per Hour
Field: Source Zone Name
Field: Delta Temperature
Field: Delta Temperature Schedule Name
Field: Minimum Zone Temperature Schedule Name
Field: Maximum Zone Temperature Schedule Name
Field: Minimum Source Zone Temperature Schedule Name
Field: Maximum Source Zone Temperature Schedule Name
Field: Minimum Outdoor Temperature Schedule Name
Field: Maximum Outdoor Temperature Schedule Name
Zone Mixing Outputs
Zone Mixing Volume [m3]
Zone Mixing Mass [kg]
Zone Mixing Sensible Heat Loss Energy [J]
Zone Mixing Sensible Heat Gain Energy [J]
Zone Mixing Latent Heat Loss Energy [J]
Zone Mixing Latent Heat Gain Energy [J]
Zone Mixing Total Heat Loss Energy [J]
Zone Mixing Total Heat Gain Energy [J]
ZoneCrossMixing
Field: Name
Field: Zone Name
Field: Schedule Name
Field: Design Flow Rate Calculation Method
Field: Design Flow Rate
Field: Flow Rate per Zone Floor Area
Field: Flow Rate per Person
Field: Air Changes per Hour
Field: Source Zone Name
Field: Delta Temperature
Field: Delta Temperature Schedule Name
Field: Minimum Zone Temperature Schedule Name
Field: Maximum Zone Temperature Schedule Name
Field: Minimum Source Zone Temperature Schedule Name
Field: Maximum Source Zone Temperature Schedule Name
Field: Minimum Outdoor Temperature Schedule Name
Field: Maximum Outdoor Temperature Schedule Name
Zone Cross Mixing Outputs
Zone Mixing Volume [m3]
Zone Mixing Mass [kg]
Zone Mixing Sensible Heat Loss Energy [J]
Zone Mixing Sensible Heat Gain Energy [J]
Zone Mixing Latent Heat Loss Energy [J]
Zone Mixing Latent Heat Gain Energy [J]
The latent heat transfer due to the sum of mixing, cross-mixing, and refrigeration-door mixing in the host (receiving) zone is the sum of all the incoming air mass flow rates multiplied by the elapsed time, the heat of vaporization (calculated for the average conditions (temperature and humidity) between the “source” and “receiving” zones) and the humidity ratio differences between the host zone and corresponding source zones. If the heat transfer is negative, the heat transfer is considered to be a zone mixing latent heat loss. If the heat transfer is positive, the heat transfer is considered to be a zone mixing latent heat gain.
Zone Mixing Total Heat Loss Energy [J]
Zone Mixing Total Heat Gain Energy [J]
ZoneRefrigerationDoorMixing
Field: Name
Field: Zone 1 Name
Field: Zone 2 Name
Field: Schedule Name
Field: Door Height
Field: Door Area
Field: Door Protection Type
Refrigeration Door Mixing Outputs
Zone Mixing Volume [m3]
Zone Mixing Mass [kg]
Zone Mixing Sensible Heat Loss Energy [J]
Zone Mixing Sensible Heat Gain Energy [J]
Zone Mixing Latent Heat Loss Energy [J]
Zone Mixing Latent Heat Gain Energy [J]
The latent heat transfer due to the sum of mixing, cross-mixing, and refrigeration-door mixing in the host (receiving) zone is the sum of all the incoming air mass flow rates multiplied by the elapsed time, the heat of vaporization (calculated for the average conditions (temperature and humidity) between the “source” and “receiving” zones) and the humidity ratio differences between the host zone and corresponding source zones. If the heat transfer is negative, the heat transfer is considered to be a zone mixing latent heat loss. If the heat transfer is positive, the heat transfer is considered to be a zone mixing latent heat gain.
Zone Mixing Total Heat Loss Energy [J]
Zone Mixing Total Heat Gain Energy [J]
ZoneEarthtube (Earth Tube)
CalcSoilSurfTemp – Auxiliary Programs Document
Field: Zone Name
Field: Schedule Name
Field: Design Flow Rate
Field: Minimum Zone Temperature when Cooling
Field: Maximum Zone Temperature when Heating
Field: Delta Temperature
Field: Earthtube Type
Field: Fan Pressure Rise
Field: Fan Total Efficiency
Field: Pipe Radius
Field: Pipe Thickness
Field: Pipe Length
Field: Pipe Thermal Conductivity
Field: Pipe Depth Under Ground Surface
Field: Soil Condition
Field: Average Soil Surface Temperature
Field: Amplitude of Soil Surface Temperature
Field: Phase Constant of Soil Surface Temperature
Field: Constant Term Flow Coefficient
Field: Temperature Term Flow Coefficient
Field: Velocity Term Flow Coefficient
Field: Velocity Squared Term Flow Coefficient
ZoneEarthTube Outputs
Earth Tube Zone Sensible Cooling Energy [J]
Earth Tube Zone Sensible Cooling Rate [W]
Earth Tube Zone Sensible Heating Energy [J]
Earth Tube Zone Sensible Heating Rate [W]
Earth Tube Air Flow Volume [m3]
Earth Tube Air Volume Flow Rate [m3/s]
Earth Tube Air Flow Mass [kg]
Earth Tube Air Mass Flow Rate [kg/s]
Earth Tube Fan Electric Energy [J]
Earth Tube Fan Electric Power [W]
Earth Tube Zone Inlet Air Temperature [C]
Earth Tube Ground Interface Temperature [C]
Earth Tube Outdoor Air Heat Transfer Rate [W]
ZoneCoolTower:Shower
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Water Supply Storage Tank Name
Field: Flow Control Type
Field: Pump Flow Rate Schedule Name
Field: Maximum Water Flow Rate
Field: Effective Tower Height
Field: Airflow Outlet Area
Field: Maximum Air Flow Rate
Field: Minimum Indoor Temperature
Field: Fraction of Water Loss
Field: Fraction of Flow Schedule
Field: Rated Power Consumption
ZoneCoolTower:Shower Outputs
Zone Cooltower Sensible Heat Loss Energy [J]
Zone Cooltower Sensible Heat Loss Rate [W]
Zone Cooltower Latent Heat Loss Energy [J]
Zone Cooltower Latent Heat Loss Rate [W]
Zone Cooltower Air Volume Flow Rate [m3/s]
Zone Cooltower Air Volume [m3]
Zone Cooltower Air Mass Flow Rate [kg/s]
Zone Cooltower Air Mass [kg]
Zone Cooltower Air Inlet Temperature [C]
Zone Cooltower Air Inlet Humidity Ratio [kgWater/kgDryAir]
Zone Cooltower Air Outlet Temperature [C]
Zone Cooltower Air Outlet Humidity Ratio [kgWater/kgDryAir]
Zone Cooltower Water Volume [m3]
Zone Cooltower Mains Water Volume [m3]
Zone Cooltower Storage Tank Water Volume [m3]
Zone Cooltower Starved Mains Water Volume [m3]
Zone Cooltower Pump Electric Power [W]
Zone Cooltower Pump Electric Energy [J]
ZoneThermalChimney (Thermal Chimney)
Field: Name
Field: Zone Name
Field: Availability Schedule Name
Field: Width of the Absorber Wall
Field: Cross Sectional Area of Air Channel Outlet
Field: Discharge Coefficient
Field: Zone <#> Name
Field: Distance from Top of Thermal Chimney to Inlet <#>
Field: Relative Ratios of Air Flow Rates Passing through Zone <#>
Field: Cross Sectional Areas of Air Channel Inlet <#>
ZoneThermalChimney Outputs
Zone Thermal Chimney Heat Loss Energy [J]
Zone Thermal Chimney Heat Gain Energy [J]
Zone Thermal Chimney Volume [m3]
Zone Thermal Chimney Mass [kg]
Zone Th ermal Chimney Volume Flow Rate [m3/s]“zone-thermal-chimney-mass-flow-rate-kgs
Zone Thermal Chimney Outlet Temperature [C]
Group – Design Objects
Input for Design Calculations and Component Autosizing
Overview
Component Autosizing
Mixing User-Specified and Autosized Inputs
Component Sizing Output
User or External Zone Design Flow Rate Inputs
User or External System Design Flow Rate Inputs
DesignSpecification:OutdoorAir
Field: Name
Field: Outdoor Air Method
Field: Outdoor Air Flow per Person
Field: Outdoor Air Flow per Zone Floor Area
Field: Outdoor Air Flow per Zone
Field: Outdoor Air Flow Changes per Hour
Field: Outdoor Air Flow Rate Fraction Schedule Name
DesignSpecification:ZoneAirDistribution
Field: Name
Field: Zone Air Distribution Effectiveness in Cooling Mode
Field: Zone Air Distribution Effectiveness in Heating Mode
Field: Zone Air Distribution Effectiveness Schedule Name
Field: Zone Secondary Recirculation Fraction
Sizing:Parameters
Field: Heating Sizing Factor
Field: Cooling Sizing Factor
Field: Timesteps in Averaging Window
Sizing Parameters Outputs
OutputControl:Sizing:Style
Field: Column Separator
Sizing:Zone
Field: Zone Name
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Zone Cooling Design Supply Air Humidity Ratio
Field: Zone Heating Design Supply Air Humidity Ratio
Field: Design Specification Outdoor Air Object Name
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Cooling Design Air Flow Method
Field: Cooling Design Air Flow Rate
Field: Cooling Minimum Air Flow per Zone Floor Area
Field: Cooling Minimum Air Flow
Field: Cooling Minimum Air Flow Fraction
Field: Heating Design Air Flow Method
Fie ld: Heating Design Air Flow Rate”field-heating-maximum-air-flow-per-zone-floor-area
Field: Heating Maximum Air Flow
Field: Heating Maximum Air Flow Fraction
Field: Design Specification Zone Air Distribution Object Name
Zone Sizing Outputs
Sizing:System
Field: AirLoop Name
Field: Type of Load to Size On
Field: Design Outdoor Air Flow Rate
Field: Minimum System Air Flow Ratio
Field: Preheat Design Temperature
Field: Preheat Design Humidity Ratio
Field: Precool Design Temperature
Field: Precool Design Humidity Ratio
Field: Central Cooling Design Supply Air Temperature
Field: Central Heating Design Supply Air Temperature
Field: Sizing Option
Field: 100% Outdoor Air in Cooling
Field: 100% Outdoor Air in Heating
Field: Central Cooling Design Supply Air Humidity Ratio
Field: Central Heating Design Supply Air Humidity Ratio
Field: Cooling Design Air Flow Method
Field: Cooling Design Air Flow Rate
Field: Heating Design Air Flow Method
Field: Heating Design Air Flow Rate
Field: System Outdoor Air Method
Field: Zone Maximum Outdoor Air Fraction
System Sizing Outputs
Sizing:Plant
Field: Plant or Condenser Loop Name
Field: Loop Type
Field: Design Loop Exit Temperature
Field: Loop Design Temperature Difference
Plant Sizing Outputs
HVAC: Primary and Secondary Systems
Group – Node-Branch Management
NodeList
Field: Name
Field: Node <#> Name (up to 25 allowed)
Node List Outputs
System Node Temperature [C]
System Node Last Timestep Temperature [C]
System Node Mass Flow Rate [kg/s]
System Node Humidity Ratio [kgWater/kgDryAir]
System Node Setpoint Temperature [C]
System Node Setpoint High Temperature [C]
System Node Setpoint Low Temperature [C]
System Node Setpoint Humidity Ratio [kgWater/kgDryAir]
System Node Setpoint Minimum Humidity Ratio [kgWater/kgDryAir]
System Node Setpoint Maximum Humidity Ratio [kgWater/kgDryAir]
System Node Relative Humidity [%]
System Node Pressure [Pa]
System Node Standard Density Volume Flow Rate [m3/s]
System Node Enthalpy [J/kg]
System Node Last Timestep Enthalpy [J/kg]
System Node Wetbulb Temperature [C]
System Node Dewpoint Temperature [C]
System Node Quality []
System Node Height [m]
System Node Current Density Volume Flow Rate [m3/s]
System Node Current Density [kg/m3]
System Node Minimum Temperature [C]
System Node Maximum Temperature [C]
System Node Minimum Limit Mass Flow Rate [kg/s]
System Node Maximum Limit Mass Flow Rate [kg/s]
System Node Minimum Available Mass Flow Rate [kg/s]
System Node Maximum Available Mass Flow Rate [kg/s]
System Node Setpoint Mass Flow Rate [kg/s]
System Node Requested Mass Flow Rate [kg/s]
System Node CO2 Concentration [ppm]
System Node Generic Air Contaminant Concentration [ppm]
BranchList
Field: Name
Field: Branch <#> Name
Branch List Output
Branch
Field: Name
Field: Maximum Flow Rate
Field: Pressure Drop Curve Name
Field Set (Branch Specifications)
Field: Component <#> Object Type
Field: Component <#> Name
Field: Component <#> Inlet Node Name
Field: Component <#> Outlet Node Name
Field: Component <#> Branch Control Type
Branch Output
Plant Branch Pressure Difference [Pa]
ConnectorList
Field: Name
Field-Set: Connection Object Type and Identifying Name (up to 2 allowed)
Field: Connector 1 Object Type
Field: Connector 1 Name
Field: Connector 2 Object Type (optional)
Field: Connector 2 Name (optional)
Connector List Outputs
Pipe:Adiabatic
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Pipe Outputs
Pipe:Adiabatic:Steam
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Steam Pipe Outputs
Pipe:Indoor
Field: Name
Field: Construction Name
Field: Fluid Inlet Node Name
Field: Fluid Outlet Node Name
Field: Environment Type
Field: Ambient Temperature Zone Name
Field: Ambient Temperature Schedule Name
Field: Ambient Air Velocity Schedule Name
Field: Pipe Inside Diameter
Field: Pipe Length
Pipe:Indoor Outputs
Pipe Fluid Heat Transfer Rate [W]
Pipe Ambient Heat Transfer Rate [W]
Pipe Fluid Heat Transfer Energy [J]
Pipe Ambient Heat Transfer Energy [J]
Pipe Mass Flow Rate [kg/s]
Pipe Inlet Temperature [C]
Pipe Outlet Temperature [C]
Pipe Volume Flow Rate [m3/s]
Pipe:Outdoor
Field: Name
Field: Construction Name
Field: Fluid Inlet Node Name
Field: Fluid Outlet Node Name
Field: Ambient Temperature Outside Air Node Name
Field: Pipe Inside Diameter
Field: Pipe Length
Pipe:Outdoor Outputs
Pipe Fluid Heat Transfer Rate [W]
Pipe Fluid Heat Transfer Energy [J]
Pipe Mass Flow Rate [kg/s]
Pipe Inlet Temperature [C]
Pipe Outlet Temperature [C]
Pipe Volume Flow Rate [m3/s]
Pipe:Underground
Field: Name
Field: Construction Name
Field: Fluid Inlet Node Name
Field: Fluid Outlet Node Name
Field: Sun Exposure
Field: Pipe Inside Diameter
Field: Pipe Length
Field: Soil Material Name
Field: Average Soil Surface Temperature
Field: Amplitude of Soil Surface Temperature
Field: Phase Constant of Soil Surface Temperature
Pipe:Underground Outputs
Pipe Fluid Heat Transfer Rate [W]
Pipe Fluid Heat Transfer Energy [J]
Pipe Mass Flow Rate [kg/s]
Pipe Volume Flow Rate [m3/s]
Pipe Inlet Temperature [C]
Pipe Outlet Temperature [C]
PipingSystem:Underground Class Objects
PipingSystem:Underground:Domain
Field: Name
Field: XMax, YMax, ZMax
Field: X-Direction Mesh Density Parameter
Field: X-Direction Mesh Type
Field: X-Direction Geometric Coefficient
Field: Y-Direction Mesh Density Parameter
Field: Y-Direction Mesh Type
Field: Y-Direction Geometric Coefficient
Field: Z-Direction Mesh Density Parameter
Field: Z-Direction Mesh Type
Field: Z-Direction Geometric Coefficient
Field: Soil Thermal Conductivity
Field: Soil Density
Field: Soil Specific Heat
Field: Soil Moisture Content Volume Fraction
Field: Soil Moisture Content Volume Fraction at Saturation
Field: Kusuda-Achenbach Average Surface Temperature
Field: Kusuda-Achenbach Average Amplitude of Surface Temperature
Field: Kusuda-Achenbach Phase Shift of Minimum Surface Temperature
Field: This Domain Includes Basement Surface Interaction
Field: Width of Basement Floor in Ground Domain
Field: Width of Basement Floor in Ground Domain
Field: Shift Pipe X Coordinates By Basement Width
Field: Name of Basement Wall Boundary Condition Model
Field: Name of Basement Wall Boundary Condition Model
Field: Convergence Criterion for the Outer Cartesian Domain Iteration Loop
Field: Maximum Iterations in the Outer Cartesian Domain Iteration Loop
Field: Number of Pipe Circuits Entered for this Domain
Field: Pipe Circuit 1 {… to N; extensible}
PipingSystem:Underground:PipeCircuit
Field: Name
Field: Pipe Thermal Conductivity
Field: Pipe Density
Field: Pipe Specific Heat
Field: Pipe Inner Diameter
Field: Pipe Outer Diameter
Field: Design Flow Rate
Field: Circuit Inlet Node Name
Field: Circuit Outlet Node Name
Field: Convergence Criterion for the Inner Radial Iteration Loop
Field: Maximum Iterations in the Inner Radial Iteration Loop
Fi eld: Number of Soil Nodes in the Inner Radial Near Pipe Mesh Region”field-radial-thickness-of-inner-radial-near-pipe-mesh-region
Field: Number of Pipe Segments Entered for this Pipe Circuit
Field: Pipe Segment 1 {… to N; extensible}
PipingSystem:Underground:PipeSegment
Field: Name
Field: X Position
Field: Y Position
Field: Flow Direction
PipingSystem:Underground Outputs
Pipe Circuit Mass Flow Rate [kg/s]
Pipe Circuit Inlet Temperature [C]
Pipe Circuit Outlet Temperature [C]
Pipe Segment Inlet Temperature [C]
Pipe Segment Outlet Temperature [C]
Pipe Circuit Fluid Heat Transfer Rate [W]
Pipe Segment Fluid Heat Transfer Rate [W]
Duct
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Duct Outputs
Group – Plant-Condenser Loops
PlantLoop
Field: Name
Field: Fluid Type
Field: User Defined Fluid Type
Field: Plant Equipment Operation Scheme Name
Field: Loop Temperature Setpoint Node Name
Field: Maximum Loop Temperature
Field: Minimum Loop Temperature
Field: Maximum Loop Flow Rate
Field: Minimum Loop Flow Rate
Field: Plant Loop Volume
Field: Plant Side Inlet Node Name
Field: Plant Side Outlet Node Name
Field: Plant Side Branch List Name
Field: Plant Side Connector List Name
Field: Demand Side Inlet Node Name
Field: Demand Side Outlet Node Name
Field: Demand Side Branch List Name
Field: Demand Side Connector List Name
Field: Load Distribution Scheme
Field: Availability Manager List Name
Field: Plant Loop Demand Calculation Scheme
Field: Common Pipe Simulation
Field: Pressure Simulation Type
Plant Loop Outputs
Plant Supply Side Cooling Demand Rate [W]
Plant Supply Side Heating Demand Rate [W]
This is the value of the net demand required to meet the heating setpoint of the loop. If the loop setpoint is met for the current HVAC timestep, Plant Supply Side Heating Demand Rate will equal sum of the total heating demand from the demand side coils on the loop. It will also equal the heating output of all boilers (or other cooling equipment) on the loop plus any pump heat added to the fluid. For example, for a hot water loop with one boiler and one pump serving one hot water coil: Plant Supply Side Heating Demand Rate will equal the boiler heat transfer plus the pump heat to fluid, and it will also equal the hot water coil total heating output.
If the plant loop setpoint is not met, Plant Supply Side Heating Demand Rate will equal the sum of the total heating demand from the demand side coils on the loop plus the additional heating required to bring the loop flow to setpoint. If the loop remains off setpoint for successive timesteps, the demand required to return to setpoint will repeat in each timestep until the loop reaches setpoint. For this reason, Plant Supply Side Heating Demand Rate should not be summed over time, because it will overstate the demand whenever the loop is off setpoint.
Plant Supply Side Inlet Mass Flow Rate [kg/s]
Plant Supply Side Inlet Temperature [C]
Plant Supply Side Outlet Temperature [C]
Plant Supply Side Not Distributed Demand Rate [W]
Plant Supply Side Unmet Demand Rate [W]
Plant Solver Sub Iteration Count [ ]
Plant Solver Half Loop Calls Count
Plant Common Pipe Mass Flow Rate [Kg/s]
Plant Common Pipe Temperature [C]
Plant Common Pipe Flow Direction Status []
Plant Common Pipe Primary Mass Flow Rate [Kg/s]
Plant Common Pipe Secondary Mass Flow Rate [Kg/s]
Primary Side Common Pipe Flow Direction []
Secondary Side Common Pipe Flow Direction []
Plant Common Pipe Primary to Secondary Mass Flow Rate [Kg/s]
Plant Common Pipe Secondary to Primary Mass Flow Rate [Kg/s]
Plant System Cycle On Off Status
Plant Demand Side Loop Pressure Difference [Pa]
Plant Supply Side Loop Pressure Difference [Pa]
Plant Loop Pressure Difference [Pa]
Plant Demand Side Lumped Capacitance Temperature [C]
Plant Supply Side Lumped Capacitance Temperature [C]
Plant Component Distributed Demand Rate [W]
CondenserLoop
Field: Name
Field: Fluid Type
Field: User Defined Fluid Type
Field: Condenser Equipment Operation Scheme Name
Field: Condenser Loop Temperature Setpoint Node Name
Field: Maximum Loop Temperature
Field: Minimum Loop Temperature
Field: Maximum Loop Flow Rate
Field: Minimum Loop Flow Rate
Field: Condenser Loop Volume
Field: Condenser Side Inlet Node Name
Field: Condenser Side Outlet Node Name
Field: Condenser Side Branch List Name
Field: Condenser Side Connector List Name
Field: Demand Side Inlet Node Name
Field: Demand Side Outlet Nodes Name
Field: Condenser Demand Side Branch List Name
Field: Condenser Demand Side Connector List Name
Field: Load Distribution Scheme
Field: Pressure Simulation Type
Condenser Loop Outputs
Plant Supply Side Cooling Demand Rate [W]
Plant Supply Side Heating Demand Rate [W]
If the condenser loop setpoint is not met, Plant Supply Side Heating Demand Rate will equal the sum of the total heating demand from the demand side components on the loop plus the additional heating required to bring the loop flow to setpoint. If the loop remains off setpoint for successive timesteps, the demand required to return to setpoint will repeat in each timestep until the loop reaches setpoint. For this reason, Plant Supply Side Heating Demand Rate should not be summed over time, because it will overstate the demand whenever the loop is off setpoint.
Plant Supply Side Inlet Mass Flow Rate [kg/s]
Plant Supply Side Inlet Temperature [C]
Cond Loop OutletNode Temperature [C]
Cond Loop Demand Not Distributed [W]
Plant Supply Side Unmet Demand Rate [W]
Plant Demand Side Loop Pressure Difference [Pa]
Plant Supply Side Loop Pressure Difference [Pa]
Plant Loop Pressure Difference [Pa]
Group – Plant-Condenser Control
Operation Schemes (Plant and Condenser)
PlantEquipmentOperationSchemes
Field: Name
Field Set: (Component Object Type, Name, Schedule) up to 8
Field: Control Scheme <#> Object Type
Field: Control Scheme <#> Name
Field: Control Scheme <#> Schedule
CondenserEquipmentOperationSchemes
Field: Name
Field Set: (Component Object Type, Name, Schedule) up to 8
Field: Control Scheme <#> Object Type
Field: Control Scheme <#> Name
Field: Control Scheme <#> Schedule
PlantEquipmentOperation:Uncontrolled
Field: Name
Field: Equipment List Name
Field: Equipment List Name
PlantEquipmentOperation:CoolingLoad
PlantEquipmentOperation:HeatingLoad
Field: Name
Field Set: (Lower limit, Upper Limit, Equip List name) up to 10
Field: Load Range <#> Lower Limit
Field: Load Range <#> Upper Limit
Field: Range <#> Equipment List Name
PlantEquipmentOperation:OutdoorDryBulb
PlantEquipmentOperation:OutdoorWetBulb
PlantEquipmentOperation:OutdoorRelativeHumidity
PlantEquipmentOperation:OutdoorDewpoint
Field: Name
Field Set: (Lower limit, Upper Limit, Equip List name) up to 10
Field: Range <#> Lower Limit
Field: Range <#> Upper Limit
Field: Range <#> Equipment List Name
PlantEquipmentOperation:OutdoorDryBulbDifference
PlantEquipmentOperation:OutdoorWetBulbDifference
PlantEquipmentOperation:OutdoorDewpointDifference
Field: Name
Field: Reference Temperature Node Name
Field Set: (Lower limit, Upper limit, Equipment List)
Field: Range <#> Lower Limit
Field: Range <#> Upper Limit
Field: Range <#> Equipment List Name
PlantEquipmentOperation:ComponentSetpoint
Field: Name
Field Set: Equipment Object Type, Name, Demand Calculation Node, Setpoint Node, Flow Rate, Operation Type)
Field: Equipment <#> Object Type
Field: Equipment <#> Name
Field: Demand Calculation <#> Node Name
Field: Setpoint <#> Node Name
Field: Component <#> Flow Rate
Field: Operation<#> Type
PlantEquipmentLi st”condenserequipmentlist
Field: Name
Field Set: (Object Type, Name) up to 10
Field: Equipment <#> Object Type
Field: Equipment <#> Name
Group – Plant Equipment
Equipment Types
Generic Chiller Outputs
Chiller Electric Power [W]
Chiller Electric Energy [J]
Chiller Evaporator Cooling Rate [W]
Chiller Evaporator Cooling Energy [J]
Chiller Evaporator Inlet Temperature [C]
Chiller Evaporator Outlet Temperature [C]
Chiller Evaporator Mass Flow Rate [kg/s]
Chiller COP [W/W]
Chiller Part Load Ratio
Chiller Cycling Ratio
Chiller Condenser Heat Transfer Rate [W]
Chiller Condenser Heat Transfer Energy [J]
Chiller Condenser Inlet Temperature [C]
Chiller Basin Heater Electric Power [W]
Chiller Basin Heater Electric Energy [J]
Chiller Condenser Inlet Temperature [C]
Chiller Condenser Outlet Temperature [C]
Chiller Condenser Mass Flow Rate [kg/s]
Chiller Drive Shaft Power [W]
Chiller Drive Shaft Energy [J]
Chiller Lube Recovered Heat Rate [W]
Chiller Lube Recovered Heat Energy [J]
Chiller Jacket Recovered Heat Rate [W]
Chiller Jacket Recovered Heat Energy [J]
Chiller Exhaust Recovered Heat Rate [W]
Chiller Exhaust Recovered Heat Energy [J]
Chiller Total Recovered Heat Rate [W]
Chiller Total Recovered Heat Energy [J]
Chiller Exhaust Temperature [C]
Chiller Heat Recovery Inlet Temperature [C]
Chiller Heat Recovery Outlet Temperature [C]
Chiller Heat Recovery Mass Flow Rate [kg/s]
Chiller Effective Heat Rejection Temperature [C]
Chiller Rate [W]
Chiller Energy [J]
Chiller Mass Flow Rate [kg/s]
Chiller Gas Mass [kg] (Gas Turbine Chiller only)
Chiller Source Hot Water Rate [W]
Chiller Source Hot Water Energy [J]
Chiller Source Steam Rate [W]
Chiller:Absorption
Field: Name
Field: Nominal Capacity
Field: Nominal Pumping Power
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Condenser Inlet Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Generator Heat Input Part Load Ratio Curve
Field: Coefficient 1 of the Steam Use Part Load Ratio Curve
Field: Coefficient 2 of the Steam Use Part Load Ratio Curve
Field: Coefficient 3 of the Steam Use Part Load Ratio Curve
Pump Electric Use Part Load Ratio Curve
Field: Coefficient 1 of the Pump Electric Use Part Load Ratio Curve
Field: Coefficient 2 of the Pump Electric Use Part Load Ratio Curve
Field: Coefficient 3 of the Pump Electric Use Part Load Ratio Curve
Field: Chilled Water Outlet Temperature Lower Limit
Field: Generator Inlet Node Name
Field: Generator Outlet Node Name
Field: Chiller Flow Mode
Field: Generator Fluid Type
Field: Design Generator Fluid Flow Rate
Field: Degree of Subcooling in Steam Generator
Field: Sizing Factor
Absorption Chiller Outputs
Chiller:Absorption:Indirect
Field: Name
Field: Nominal Capacity
Field: Nominal Pumping Power
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Condenser Inlet Temperature
Field: Condenser Inlet Temperature Lower Limit
Field: Chilled Water Outlet Temperature Lower Limit
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Field: Chiller Flow Mode
Field: Generator Heat Input Function of Part Load Ratio Curve Name
Field: Pump Electric Input Function of Part Load Ratio Curve Name
Field: Generator Inlet Node Name
Field: Generator Outlet Node Name
Field: Capacity Correction Function of Condenser Temperature Curve Name
Field: Capacity Correction Function of Chilled Water Temperature Curve Name
Field: Capacity Correction Function of Generator Temperature Curve Name
Field: Generator Heat Input Correction Function of Condenser Temperature Curve Name
Field: Generator Heat Input Correction Function of Chilled Water Temperature Curve Name
Field: Generator Heat Source Type
Field: Design Generator Fluid Flow Rate
Field: Temperature Lower Limit Generator Inlet
Field: Degree of Subcooling in Steam Generator
Field: Degree of Subcooling in Steam Condensate Loop
Field: Sizing Factor
Indirect Absorption Chiller Outputs
Chiller:ConstantCOP
Field: Name
Field: Nominal Capacity
Field: Nominal COP
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Condenser Type
Field: Chiller Flow Mode
Field: Sizing Factor
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Constant COP Chiller Outputs
Chiller:Electric
Field: Name
Field: Condenser Type
Field: Nominal Capacity
Field: Nominal COP
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Condenser Inlet Temperature
Field: Temperature Rise Coefficient
Field: Design Chilled Water Outlet Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Fluid Flow Rate
Capacity Ratio Curve
Field: Coefficient 1 of Capacity Ratio Curve
Field: Coefficient 2 of Capacity Ratio Curve
Field: Coefficient 3 of Capacity Ratio Curve
Power Ratio Curve
Field: Coefficient1 of the power ratio curve
Field: Coefficient 2 of Power Ratio Curve
Field: Coefficient 3 of Power Ratio Curve
Full Load Ratio Curve
Field: Coefficient 1 of Full Load Ratio Curve
Field: Coefficient 2 of Full Load Ratio Curve
Field: Coefficient 3 of Full Load Ratio Curve
Field: Chilled Water Outlet Temperature Lower Limit
Field: Chiller Flow Mode
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Inlet Node Name
Field: Heat Recovery Outlet Node Name
Field: Sizing Factor
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Condenser Heat Recovery Relative Capacity Fraction
Field: Heat Recovery Inlet High Temperature Limit Schedule Name
Field: Heat Recovery Leaving Temperature Setpoint Node Name
Electric Chiller Outputs
Chiller:Electric:EIR
Field: Name
Field: Reference Capacity
Field: Reference COP
Field: Reference Leaving Chilled Water Temperature
Field: Reference Entering Condenser Fluid Temperature
Field: Reference Chilled Water Flow Rate
Field: Reference Condenser Fluid Flow Rate
Field: Cooling Capacity Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Minimum Unloading Ratio
Field: Chilled Water Side Inlet Node
Field: Chilled Water Side Outlet Node
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Condenser Type
Field: Condenser Fan Power Ratio
Field: Fraction of Compressor Electric Power Rejected by Condenser
Field: Leaving Chilled Water Lower Temperature Limit
Field: Chiller Flow Mode
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Side Inlet Node
Field: Heat Recovery Side Outlet Node
Field: Sizing Factor
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Condenser Heat Recovery Relative Capacity Fraction
Field: Heat Recovery Inlet High Temperature Limit Schedule Name
Field: Heat Recovery Leaving Temperature Setpoint Node Name
Electric EIR Chiller Outputs
Chiller Condenser Fan Electric Power [W]
Chiller Condenser Fan Electric Energy [J]
Chiller Capacity Temperature Modifier Multiplier []
Chiller EIR Temperature Modifier Multiplier []
Chiller EIR Part Load Modifier Multiplier []
Chiller Part Load Ratio []
Chiller Cycling Ratio []
Chiller False Load Heat Transfer Rate [W]
Chiller False Load Heat Transfer Energy [J]
Chiller:Electric:ReformulatedEIR
Field: Chiller Name
Field: Reference Capacity
Field: Reference COP
Field: Reference Leaving Chilled Water Temperature
Field: Reference Leaving Condenser Water Temperature
Field: Reference Chilled Water Flow Rate
Field: Reference Condenser Water Flow Rate
Field: Cooling Capacity Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Minimum Unloading Ratio
Field: Chilled Water Side Inlet Node
Field: Chilled Water Side Outlet Node
Field: Condenser Side Inlet Node
Field: Condenser Side Outlet Node
Field: Fraction of Compressor Electric Power Rejected by Condenser
Field: Leaving Chilled Water Lower Temperature Limit
Field: Chiller Flow Mode Type
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Side Inlet Node
Field: Heat Recovery Side Outlet Node
Field: Sizing Factor
Field: Condenser Heat Recovery Relative Capacity Fraction
Field: Heat Recovery Inlet High Temperature Limit Schedule Name
Field: Heat Recovery Leaving Temperature Setpoint Node Name
Electric Reformulated EIR Chiller Outputs
Chiller:EngineDriven
Field: Name
Field: Condenser Type
Field: Nominal Capacity
Field: Nominal COP
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Condenser Inlet Temperature
Field: Temperature Rise Coefficient
Field: Design Chilled Water Outlet Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Capacity Ratio Curve
Field: Coefficient 1 of Capacity Ratio Curve
Field: Coefficient 2 of Capacity Ratio Curve
Field: Coefficient 3 of Capacity Ratio Curve
Power Ratio Curve
Field: Coefficient 1 of Power Ratio Curve
Field: Coefficient 2 of Power Ratio Curve
Field: Coefficient 3 of Power Ratio Curve
Full Load Ratio Curve
Field: Coefficient 1 of Full Load Ratio Curve
Field: Coefficient 2 of Full Load Ratio Curve
Field: Coefficient 3 of Full Load Ratio Curve
Field Chilled Water Outlet Temperature Lower Limit
Field: Fuel Use Curve Name
Field: Jacket Heat Recovery Curve Name
Field: Lube Heat Recovery Curve Name
Field: Total Exhaust Energy Curve Name
Field: Exhaust Temperature Curve Name
U-Factor Times Area Curve
Field: Coefficient 1 of U-Factor Times Area Curve
Field: Coefficient 2 of U-Factor Times Area Curve
Field: Maximum Exhaust Flow per Unit of Power Output
Field: Design Minimum Exhaust Temperature
Field: Fuel Type
Field: Fuel Higher Heating Value
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Inlet Node Name
Field: Heat Recovery Outlet Node Name
Field: Chiller Flow Mode
Field: Maximum Temperature for Heat Recovery at Heat Recovery Outlet Node
Field: Sizing Factor
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Engine Driven Chiller Outputs
Chiller:CombustionTurbine
Field: Name
Field: Condenser Type
Field: Nominal Capacity
Field: Nominal COP
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Condenser Inlet Temperature
Field: Temperature Rise Coefficient
Field: Design Chilled Water Outlet Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Capacity Ratio Curve
Field: Coefficient 1 of Capacity Ratio Curve
Field: Coefficient 2 of Capacity Ratio Curve
Field: Coefficient 3 of Capacity Ratio Curve
Power Ratio Curve
Field: Coefficient 1 of Power Ratio Curve
Field: Coefficient 2 of Power Ratio Curve
Field: Coefficient 3 of Power Ratio Curve
Full Load Ratio Curve
Field: Coefficient 1 of Full Load Ratio Curve
Field: Coefficient 2 of Full Load Ratio Curve
Field: Coefficient 3 of Full Load Ratio Curve
Field: Chilled Water Outlet Temperature Lower Limit
Fuel Input Curve
Field: Coefficient 1 of Fuel Input Curve
Field: Coefficient 2 of Fuel Input Curve
Field: Coefficient 3 of Fuel Input Curve
Field: Coefficient 1 of Temperature Based Fuel Input Curve
Field: Coefficient 2 of Temperature Based Fuel Input Curve
Field: Coefficient 3 of Temperature Based Fuel Input Curve
Exhaust Flow Curve
Field: Coefficient 1 of Exhaust Flow Curve
Field: Coefficient 2 of Exhaust Flow Curve
Field: Coefficient 3 of Exhaust Flow Curve
Exhaust Gas Temperature Curve
Field: Coefficient 1 of Exhaust Gas Temperature Curve
Field: Coefficient 2 of Exhaust Gas Temperature Curve
Field: Coefficient 3 of Exhaust Gas Temperature Curve
Field: Coefficient 1 of Temperature Based Exhaust Gas Temperature Curve
Field: Coefficient 2 of Temperature Based Exhaust Gas Temperature Curve
Field: Coefficient 3 of Temperature Based Exhaust Gas Temperature Curve
Recovery Lubricant Heat Curve
Field: Coefficient 1 of Recovery Lube Heat Curve
Field: Coefficient 2 of Recovery Lube Heat Curve
Field: Coefficient 3 of Recovery Lube Heat Curve
U-Factor Times Area Curve Curve
Field: Coefficient 1 of U-Factor Times Area Curve
Field: Coefficient 2 of U-Factor Times Area Curve
Field: Gas Turbine Engine Capacity
Field: Maximum Exhaust Flow per Unit of Power Output
Field: Design Steam Saturation Temperature
Field: Fuel Higher Heating Value
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Inlet Node Name
Field: Heat Recovery Outlet Node Name
Field: Chiller Flow Mode
Field: Fuel Type
Field: Heat Recovery Maximum Temperature
Field: Sizing Factor
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Combustion Turbine Chiller Outputs
ChillerHeater:Absorption:DirectFired
Field: Name
Field: Nominal Cooling Capacity
Field: Heating to Cooling Capacity Ratio
Field: Fuel Input to Cooling Output Ratio
Field: Fuel Input to Heating Output Ratio
Field: Electric Input to Cooling Output Ratio
Field: Electric Input to Heating Output Ratio
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Hot Water Inlet Node Name
Field: Hot Water Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Entering Condenser Water Temperature
Field: Design Leaving Chilled Water Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Field: Design Hot Water Flow Rate
Field: Cooling Capacity Function of Temperature Curve Name
Field: Fuel Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Fuel Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Heating Capacity Function of Cooling Capacity Curve Name
Field: Fuel Input to Heat Output Ratio During Heating Only Operation Curve Name
Field: Temperature Curve Input Variable
Field: Condenser Type
Field: Chilled Water Temperature Lower Limit
Field: Fuel Higher Heating Value
Field: Chiller Flow Mode
Field: Fuel Type
Field: Sizing Factor
Direct Fired Absorption Chiller Outputs
Chiller Heater Electric Power [W]
Chiller Heater Electric Energy [J]
Chiller Heater Rate [W]
Chiller Heater Energy [J]
Chiller Heater Runtime Fraction []
Chiller Heater Cooling Rate [W]
Chiller Heater Cooling Energy [J]
Chiller Heater Cooling Electric Power [W]
Chiller Heater Cooling Electric Energy [J]
Chiller Heater Cooling Rate [W]
Chiller Heater Cooling Part Load Ratio
Chiller Heater Cooling COP
Chiller Heater Heating Rate [W]
Chiller Heater Heating Energy [J]
Chiller Heater Heating Rate [W]
Chiller Heater Heating Energy [J]
Chiller Heater Heating Electric Power [W]
Chiller Heating Heating Electric Energy [J]
Chiller Heater Heating Rate [W]
Chiller Heater Heating Part Load Ratio
Chiller Heater Heating Inlet Temperature [C]
Chiller Heater Heating Outlet Temperature [C]
Chiller Heater Heating Mass Flow Rate [kg/s]
ChillerHeater:Absorption:DoubleEffect
Field: Name
Field: Nominal Cooling Capacity
Field: Heating to Cooling Capacity Ratio
Field: Thermal Energy Input to Cooling Output Ratio
Field: Thermal Energy Input to Heating Output Ratio
Field: Electric Input to Cooling Output Ratio
Field: Electric Input to Heating Output Ratio
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Hot Water Inlet Node Name
Field: Hot Water Outlet Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Design Entering Condenser Water Temperature
Field: Design Leaving Chilled Water Temperature
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Field: Design Hot Water Flow Rate
Field: Cooling Capacity Function of Temperature Curve Name
Field: Thermal Energy Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Thermal Energy Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Heating Capacity Function of Cooling Capacity Curve Name
Field: Thermal Energy Input to Heat Output Ratio During Heating Only Operation Curve Name
Field: Temperature Curve Input Variable
Field: Condenser Type
Field: Chilled Water Temperature Lower Limit
Field: Exhaust Source
Field: Exhaust Source Object
Field: Sizing Factor
Exhaust Fired Absorption Chiller Outputs
Chiller Heater Electric Power [W]
Chiller Heater Electric Energy [J]
Chiller Heater Runtime Fraction []
Chiller Heater Maximum Cooling Rate [W]
Chiller Heater Cooling Part Load Ratio []
Chiller Heater Cooling Source Heat COP [W/W]
Chiller Heater Heating Rate [W]
Chiller Heater Heating Energy [J]
Chiller Heater Heating Electric Power [W]
Chiller Heater Heating Electric Energy [J]
Chiller Heater Maximum Heating Rate [W]
Chiller Heater Heating Part Load Ratio []
Chiller Heater Heating Inlet Temperature [C]
Chiller Heater Heating Outlet Temperature [C]
Chiller Heater Heating Mass Flow Rate [kg/s]
Chiller Heater Condenser Inlet Temperature [C]
Chiller Heater Condenser Heat Transfer Energy [J]
Chiller Heater Condenser Heat Transfer Rate [W]
Chiller Heater Condenser Mass Flow Rate [kg/s]
Chiller Heater Condenser Outlet Temperature [C]
Chiller Heater Evaporator Cooling Energy [J]
Chiller Heater Evaporator Cooling Rate [W]
Chiller Heater Evaporator Inlet Temperature [C]
Chiller Heater Evaporator Mass Flow Rate [kg/s]
Chiller Heater Evaporator Outlet Temperature [C]
Chiller Heater Cooling Electric Energy [J]
Chiller Heater Cooling Electric Power [W]
Chiller Heater Source Exhaust Inlet Mass Flow Rate [kg/s]
Chiller Heater Source Exhaust Inlet Temperature [C]
Boiler:HotWater
Field: Name
Field: Fuel Type
Field: Nominal capacity
Fuel Use Equation
Field: Nominal Thermal Efficiency
Field: Efficiency Curve Temperature Evaluation Variable
Field: Normalized Boiler Efficiency Curve Name
Field: Design Water Outlet Temperature
Field: Design Water Flow Rate
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Boiler Water Inlet Node Name
Field: Boiler Water Outlet Node Name
Field: Water Outlet Upper Temperature Limit
Field: Boiler Flow Mode
Field: Parasitic Electric Load
Field: Sizing Factor
Boiler:HotWater Outputs
Boiler Heating Rate [W]
Boiler Heating Energy [J]
Boiler Inlet Temperature [C]
Boiler Outlet Temperature [C]
Boiler Mass Flow Rate [kg/s]
Boiler Part Load Ratio []
Boiler Rate [W]
[Boiler Energy [J] ](page-024.html#boiler-energy-j)
Boiler Electric Power [W]
Boiler Ancillary Electric Power [W]
Boiler Ancillary Electric Energy [J]
Boiler:Steam
Field: Name
Field: Fuel Type
Field: Maximum Operating Pressure
Field: Theoretical Efficiency
Field: Design Outlet Steam Temperature
Field: Nominal Capacity
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Coefficient 1 of Fuel Use Function of Part Load Ratio Curve
Field: Coefficient 2 of Fuel Use Function of Part Load Ratio Curve
Field: Coefficient 3 of Fuel Use Function of Part Load Ratio Curve
Field: Water Inlet Node Name
Field: Steam Outlet Node Name
Field: Sizing Factor
Steam Boiler Outputs
Boiler Heating Rate [W]
Boiler Heating Energy [J]
Boiler Steam Inlet Temperature [C]
Boiler Steam Outlet Temperature [C]
Boiler Steam Mass Flow Rate [kg/s]
Boiler Rate [W]
Boiler Energy [J]
Boiler Electric Power [W]
Boiler Electric Energy [J]
Water to Water Heat Pumps
HeatPump:WaterToWater:EquationFit:Cooling
Field: Name
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Load Side Inlet Node Name
Field: Load Side Outlet Node Name
Field: Rated Load Side Flow Rate
Field: Rated Source Side Flow Rate
Field: Rated Cooling Capacity
Field: Rated Cooling Power Consumption
Fields: Cooling Capacity Coefficients
Field: Cooling Capacity Coefficient 1-5
Field: Cooling Compressor Power Coefficients
Field: Cooling Compressor Power Coefficient 1-5
Field: Cycle Time
Water to Water Heat Pump Equation Fit Outputs
Water to Water Heat Pump Electric Energy [J]
Water to Water Heat Pump Load Side Heat Transfer Energy [J]
Water to Water Heat Pump Source Side Heat Transfer Energy [J]
Water to Water Heat Pump Electric Power [W]
Water to Water Heat Pump Load Side Heat Transfer Rate [W]
Water to Water Heat Pump Source Side Heat Transfer Rate [W]
Water to Water Heat Pump Load Side Outlet Temperature [C]
Water to Water Heat Pump Load Side Inlet Temperature [C]
Water to Water Heat Pump Source Side Outlet Temperature [C]
Water to Water Heat Pump Source Side Inlet Temperature [C]
Water to Water Heat Pump Load Side Mass Flow Rate [kg/s]
Water to Water Heat Pump Source Side Mass Flow Rate [kg/s]
HeatPump:WaterToWater:EquationFit:Heating
Field: Name
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Load Side Inlet Node Name
Field: Load Side Outlet Node Name
Field: Rated Load Side Flow Rate
Field: Rated Source Side Flow Rate
Field: Rated Heating Capacity
Field: Rated Heating Power Consumption
Fields: Heating Capacity Coefficients
Field: Heating Capacity Coefficient 1-5
Field: Heating Compressor Power Coefficients
Field: Heating Compressor Power Coefficient 1-5
Field: Cycle Time
HeatPump:WaterToWater:ParameterEstimation:Cooling
Field: Name
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Load Side Inlet Node Name
Field: Load Side Outlet Node Name
Field: Nominal COP
Field: Nominal Capacity
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Load Side Flow Rate
Field: Source Side Flow Rate
Field: Load Side Heat Transfer Coefficient
Field: Source Side Heat Transfer Coefficient
Field: Piston Displacement
Field: Compressor Clearance Factor
Field: Compressor Suction and Discharge Pressure Drop
Field: Superheating
Field: Constant Part of Electromechanical Power Losses
Field: Loss Factor
Field: High Pressure Cut Off
Field: Low Pressure Cut Off
Field: Cycle Time
HeatPump:WaterToWater:ParameterEstimation:Heating
Field: Name
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Load Side Inlet Node Name
Field: Load Side Outlet Node Name
Field: Nominal COP
Field: Nominal Capacity
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Load Side Flow Rate
Field: Source Side Flow Rate
Field: Load Side Heat Transfer Coefficient
Field: Source Side Heat Transfer Coefficient
Field: Piston Displacement
Field: Compressor Clearance Factor
Field: Compressor Suction and Discharge Pressure Drop
Field: Superheating
Field: Constant Part of Electromechanical Power Losses
Field: Loss Factor
Field: High Pressure Cut Off
Field: Low Pressure Cut Off
Field: Cycle Time
Steps to specify the Ground Source Heat Pump
Water to Water Heat Pump Parameter Estimation Outputs
Water to Water Heat Pump Electric Power [W]
Water to Water Heat Pump Electric Power [W]
Water to Water Heat Pump Electric Energy [J]
Water to Water Heat Pump Electric Energy [J]
Water to Water Heat Pump Load Side Heat Transfer Rate [W]
Water to Water Heat Pump Load Side Heat Transfer Rate [W]
Water to Water Heat Pump Load Side Heat Transfer Energy [J]
Water to Water Heat Pump Load Side Heat Transfer Energy [J]
Water to Water Heat Pump Source Side Heat Transfer Rate [W]
Water to Water Heat Pump Source Side Heat Transfer Rate [W]
Water to Water Heat Pump Source Side Heat Transfer Energy [J]
Water to Water Heat Pump Source Side Heat Transfer Energy [J]
Water to Water Heat Pump Load Side Outlet Temperature [C]
Water to Water Heat Pump Load Side Outlet Temperature [C]
Water to Water Heat Pump Load Side Inlet Temperature [C]
Water to Water Heat Pump Load Side Inlet Temperature [C]
Water to Water Heat Pump Source Side Outlet Temperature [C]
[Water to Water Heat Pump Source Side Outlet Temperature °C]](page-024.html#water-to-water-heat-pump-source-side-outlet-temperature-c-2)
Water to Water Heat Pump Source Side Inlet Temperature [C]
Water to Water Heat Pump Source Side Inlet Temperature [C]
Water to Water Heat Pump Load Side Mass Flow Rate [kg/s]
Water to Water Heat Pump Load Side Mass Flow Rate [kg/s]
Water to Water Heat Pump Source Side Mass Flow Rate [kg/s]
Water to Water Heat Pump Source Side Mass Flow Rate [kg/s]
DistrictCooling
Field: Name
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Nominal Capacity
DistrictCooling Outputs
District Cooling Chilled Water Rate [W]
District Cooling Chilled Water Energy [J]
District Cooling Rate [W]
District Cooling Inlet Temperature [C]
District Cooling Outlet Temperature [C]
District Cooling Mass Flow Rate [kg/s]
DistrictHeating
Field: Name
Field: Hot Water Inlet Node Name
Field: Hot Water Outlet Node Name
Field: Nominal Capacity
DistrictHeating Outputs
District Heating Hot Water Rate [W]
District Heating Hot Water Energy [J]
District Heating Rate [W]
District Heating Inlet Temperature [C]
District Heating Outlet Temperature [C]
District Heating Mass Flow Rate [kg/s]
PlantComponent:TemperatureSource
Field: Name
Field: Inlet Node
Field: Outlet Node
Field: Design Volume Flow Rate [m3/s]
Field: Temperature Specification Type
Field: Source Temperature [C]
Field: Source Temperature Schedule Name
PlantComponent:TemperatureSource Outputs
Plant Temperature Source Component Mass Flow Rate [kg/s]
Plant Temperature Source Component Inlet Temperature [C]
Plant Temperature Source Component Outlet Temperature [C]
Plant Temperature Source Component Source Temperature [C]
Plant Temperature Source Component Heat Transfer Rate [W]
Plant Temperature Source Component Heat Transfer Energy [J]
CentralHeatPumpSystem
Field: Name
Field: Control Method
This field must contain a keyword defines how the central heat pump system controls the interaction between the chiller-heater modules and the water loops to meet the cooling and heating demands. Currently, the only available option is SmartMixing.
Field: Cooling Loop Inlet Node Name
Field: Cooling Loop Outlet Node Name
Field: Source Loop Inlet Node Name
Field: Source Loop Outlet Node Name
Field: Heating Loop Inlet Node Name
Field: Heating Loop Outlet Node Name
Field: Ancillary Power
Field: Ancillary Operation Schedule Name
Field Set: Individual Chiller-Heater Module Objects
Field: Chiller Heater Module Performance Component Object Type
Field: Chiller Heater Module Performance Component Name
Field: Chiller Heater Module Control Schedule Name
Field: Number of Chiller Heater Modules
Central Heat Pump System Outputs
Chiller Heater System Cooling Electric Power [W]
Chiller Heater System Cooling Electric Energy [J]
Chiller Heater System Heating Electric Power [W]
Chiller Heater System Heating Electric Energy [J]
Chiller Heater System Cooling Rate [W]
Chiller Heater System Cooling Energy [J]
Chiller Heater System Heating Rate [W]
Chiller Heater System Heating Energy [J]
Chiller Heater System Source Heat Transfer Rate [W]
Chiller Heater System Source Heat Transfer Energy [J]
Chiller Heater System Cooling Inlet Temperature [C]
Chiller Heater System Cooling Outlet Temperature [C]
Chiller Heater System Cooling Mass Flow Rate [kg/s]
Chiller Heater System Heating Inlet Temperature [C]
Chiller Heater System Heating Outlet Temperature [C]
Chiller Heater System Heating Mass Flow Rate [kg/s]
Chiller Heater System Source Inlet Temperature [C]
Chiller Heater System Source Outlet Temperature [C]
Chiller Heater System Source Mass Flow Rate [kg/s]
ChillerHeaterPerformance:EIectric:EIR
Field: Name
Field: Reference Cooling Mode Evaporator Capacity
Field: Reference Cooling Mode COP
Field: Reference Cooling Mode Leaving Chilled Water Temperature
Field: Reference Cooling Mode Entering Condenser Water Temperature
Field: Reference Cooling Mode Leaving Condenser Water Temperature
Field: Reference Heating Mode Cooling Capacity Ratio
Field: Reference Heating Mode Cooling Power Ratio
Field: Reference Heating Mode Leaving Chilled Water Temperature
Field: Reference Heating Mode Leaving Condenser Water Temperature
Field: Reference Heating Mode Entering Condenser Water Temperature
Field: Heating Mode Entering Chilled Water Temperature Low Limit
Field: Chilled Water Flow Mode Type
Field: Design Chilled Water Flow Rate
Field: Design Condenser Water Flow Rate
Field: Design Hot Water Flow Rate
Field: Compressor Motor Efficiency
Field: Condenser Type
Field: Cooling Mode Temperature Curve Condenser Water Independent Variable
Field: Cooling Mode Cooling Capacity Function of Temperature Curve Name
Field: Cooling Mode Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Cooling Mode Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Cooling Mode Cooling Capacity Optimum Part Load Ratio
Field: Heating Mode Temperature Curve Condenser Water Independent Variable
Field: Heating Mode Cooling Capacity Function of Temperature Curve Name
Field: Heating Mode Electric Input to Cooling Output Ratio Function of Temperature Curve Name
Field: Heating Mode Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
Field: Heating Mode Cooling Capacity Optimum Part Load Ratio
Field: Sizing Factor
ChillerHeaterPerformance:Electric:EIR Outputs
Chiller Heater Operation Mode Unit [ ]
Chiller Heater Part Load Ratio Unit [ ]
Chiller Heater Cycling Ratio Unit [ ]
Chiller Heater Cooling Electric Power Unit [W]
Chiller Heater Cooling Electric Energy Unit [J]
Chiller Heater Heating Electric Power Unit [W]
Chiller Heater Heating Electric Energy Unit [J]
Chiller Heater Cooling Rate Unit [W]
Chiller Heater Cooling Energy Unit [J]
Chiller Heater False Load Heat Transfer Rate Unit [W]
Chiller Heater False Load Heat Transfer Energy Unit [J]
Chiller Heater Condenser Heat Transfer Rate Unit [C]
Chiller Heater Condenser Heat Transfer Energy Unit [C]
Chiller Heater Evaporator Inlet Temperature Unit [C]
Chiller Heater Evaporator Outlet Temperature Unit [C]
Chiller Heater Evaporator Mass Flow Rate Unit [C]
Chiller Heater Condenser Inlet Temperature Unit [C]
Chiller Heater Condenser Outlet Temperature Unit [C]
Chiller Heater Condenser Mass Flow Rate Unit [C]
Chiller Heater COP Unit [C]
Chiller Heater Capacity Temperature Modifier Multiplier Unit [C]
Chiller Heater EIR Temperature Modifier Multiplier Unit [C]
Chiller Heater EIR Part Load Modifier Multiplier Unit [C]
Thermal Storage Objects
ThermalStorage:Ice:Simple
Field: Name
Field: Ice Storage Type
Field: Capacity
Field: Inlet Node Name
Field: Outlet Node Name
Simple Ice Storage Outputs
Ice Thermal Storage Requested Load [W]
Ice Thermal Storage End Fraction []
Ice Thermal Storage Mass Flow Rate [kg/s]
Ice Thermal Storage Inlet Temperature [C]
Ice Thermal Storage Outlet Temperature [C]
Ice Thermal Storage Cooling Discharge Rate [W]
Ice Thermal Storage Cooling Discharge Energy [J]
Ice Thermal Storage Cooling Charge Rate [W]
Ice Thermal Storage Cooling Charge Energy [J]
ThermalStorage:Ice:Detailed
Field: Name
Field: Availability Schedule Name
Field: Capacity
Field: Inlet Node Name
Field: Outlet Node Name
Field: Discharging Curve Object Type
Field: Discharging Curve Name
Field: Charging Curve Object Type
Field: Charging Curve Name
Field: Timestep of the Curve Data
Field: Parasitic Electric Load During Discharging
Field: Parasitic Electric Load During Charging
Field: Tank Loss Coefficient
Field: Freezing Temperature of Storage Medium
Field: Thaw Process Indicator
Detailed Ice Storage Outputs
Ice Thermal Storage Cooling Rate [W]
Ice Thermal Storage Change Fraction []
Ice Thermal Storage End Fraction [ ]
Ice Thermal Storage On Coil Fraction [ ]
Ice Thermal Storage Mass Flow Rate [kg/s]
Ice Thermal Storage Bypass Mass Flow Rate [kg/s]
Ice Thermal Storage Tank Mass Flow Rate [kg/s]
Ice Thermal Storage Fluid Inlet Temperature [C]
Ice Thermal Storage Blended Outlet Temperature [C]
Ice Thermal Storage Tank Outlet Temperature [C]
Ice Thermal Storage Cooling Discharge Rate [W]
Ice Thermal Storage Cooling Discharge Energy [J]
Ice Thermal Storage Cooling Charge Rate [W]
Ice Thermal Storage Cooling Charge Energy [J]
Ice Thermal Storage Ancillary Electric Power [W]
Ice Thermal Storage Ancillary Electric Energy [J]
ThermalStorage:ChilledWater:Mixed
Field: Name
Field: Tank Volume
Field: Setpoint Temperature Schedule Name
Field: Deadband Temperature Difference
Field: Minimum Temperature Limit
Field: Nominal Cooling Capacity
Field: Ambient Temperature Indicator
Field: Ambient Temperature Schedule Name
Field: Ambient Temperature Zone Name
Field: Ambient Temperature Outdoor Air Node Name
Field: Heat Gain Coefficient from Ambient Temperature
Field: Use Side Inlet Node Name
Field: Use Side Outlet Node Name
Field: Use Side Heat Transfer Effectiveness
Field: Use Side Availability Schedule Name
Field: Use Side Design Flow Rate
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Source Side Heat Transfer Effectiveness
Field: Source Side Availability Schedule Name
Field: Source Side Design Flow Rate
Field: Tank Recovery Time
Chilled Water Mixed Thermal Storage Outputs
Chilled Water Thermal Storage Tank Temperature [C]
Chilled Water Thermal Storage Final Tank Temperature [C]
Chilled Water Thermal Storage Tank Heat Gain Rate [W]
Chilled Water Thermal Storage Tank Heat Gain Energy [J]
Chilled Water Thermal Storage Use Side Mass Flow Rate [kg/s]
Chilled Water Thermal Storage Use Side Inlet Temperature [C]
Chilled Water Thermal Storage Use Side Outlet Temperature [C]
Chilled Water Thermal Storage Use Side Heat Transfer Rate [W]
Chilled Water Thermal Storage Use Side Heat Transfer Energy [J]
Chilled Water Thermal Storage Source Side Mass Flow Rate [kg/s]
Chilled Water Thermal Storage Source Side Inlet Temperature [C]
Chilled Water Thermal Storage Source Side Outlet Temperature [C]
Chilled Water Thermal Storage Source Side Heat Transfer Rate [W]
Chilled Water Thermal Storage Source Side Heat Transfer Energy [J]
ThermalStorage:ChilledWater:Stratified
Field: Name
Field: Tank Volume
Field: Tank Height
Field: Tank Shape
Field: Tank Perimeter
Field: Setpoint Temperature Schedule Name
Field: Deadband Temperature Difference
Field: Temperature Sensor Height
Field: Minimum Temperature Limit
Field: Nominal Cooling Capacity
Field: Ambient Temperature Indicator
Field: Ambient Temperature Schedule Name
Field: Ambient Temperature Zone Name
Field: Ambient Temperature Outside Air Node Name
Field: Uniform Skin Loss Coefficient per Unit Area to Ambient Temperature
Field: Use Side Inlet Node Name
Field: Use Side Outlet Node Name
Field: Use Side Heat Transfer Effectiveness
Field: Use Side Availability Schedule Name
Field: Use Side Inlet Height
Field: Use Side Outlet Height
Field: Use Side Design Flow Rate
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Source Side Heat Transfer Effectiveness
Field: Source Side Availability Schedule Name
Field: Source Side Inlet Height
Field: Source Side Outlet Height
Field: Source Side Design Flow Rate
Field: Tank Recovery Time
Field: Inlet Mode
Field: Number of Nodes
Field: Additional Destratification Conductivity
Field: Node 1-10 Additional Loss Coefficient
Chilled Water Stratified Thermal Storage Outputs
Chilled Water Thermal Storage Tank Temperature [C]
Chilled Water Thermal Storage Tank Final Temperature [C]
Chilled Water Thermal Storage Tank Heat Gain Rate [W]
Chilled Water Thermal Storage Tank Heat Gain Energy [J]
Chilled Water Thermal Storage Use Side Mass Flow Rate [kg/s]
Chilled Water Thermal Storage Use Side Inlet Temperature [C]
Chilled Water Thermal Storage Use Side Outlet Temperature [C]
Chilled Water Thermal Storage Use Side Heat Transfer Rate [W]
Chilled Water Thermal Storage Use Side Heat Transfer Energy [J]
Chilled Water Thermal Storage Source Side Mass Flow Rate [kg/s]
Chilled Water Thermal Storage Source Side Inlet Temperature [C]
Chilled Water Thermal Storage Source Side Outlet Temperature [C]
Chilled Water Thermal Storage Source Side Heat Transfer Rate [W]
Chilled Water Thermal Storage Source Side Heat Transfer Energy [J]“chilled-water-thermal-storage-temperature-node-1-10-c
Chilled Water Thermal Storage Final Temperature Node 1-10 [C]
Group – Water Heaters
Standard Ratings
Water Heater:Mixed
Field: Name
Field: Tank Volume
Field: Setpoint Temperature Schedule Name
Field: Deadband Temperature Difference
Field: Maximum Temperature Limit
Field: Heater Control Type
Field: Heater Maximum Capacity
Field: Heater Minimum Capacity
Field: Heater Ignition Minimum Flow Rate
Field: Heater Ignition Delay
Field: Heater Fuel Type
Field: Heater Thermal Efficiency
Field: Part Load Factor Curve Name
Field: Off-Cycle Parasitic Fuel Consumption Rate
Field: Off-Cycle Parasitic Fuel Type
Field: Off-Cycle Parasitic Heat Fraction to Tank
Field: On-Cycle Parasitic Fuel Consumption Rate
Field: On-Cycle Parasitic Fuel Type
Field: On-Cycle Parasitic Heat Fraction to Tank
Field: Ambient Temperature Indicator
Field: Ambient Temperature Schedule Name
Field: Ambient Temperature Zone Name
Field: Ambient Temperature Outdoor Air Node Name
Field: Off-Cycle Loss Coefficient to Ambient Temperature
Field: Off-Cycle Loss Fraction to Zone
Field: On-Cycle Loss Coefficient to Ambient Temperature
Field: On-Cycle Loss Fraction to Zone
Field: Peak Use Flow Rate
Field: Use Flow Rate Fraction Schedule Name
Field: Cold Water Supply Temperature Schedule Name
Field: Use Side Inlet Node Name
Field: Use Side Outlet Node Name
Field: Use Side Effectiveness
Field: Source Side Inlet Node Name
Field: Source Side Outlet Node Name
Field: Source Side Effectiveness
Field: Use Side Design Flow Rate
Field: Source Side Design Flow Rate
Field: Indirect Water Heating Recovery Time
Mixed Water Heater Outputs
Water Heater Tank Temperature [C]
Water Heater Final Tank Temperature [C]
Water Heater Heat Loss Rate [W]
Water Heater Heat Loss Energy [J]
Water Heater Use Side Mass Flow Rate [kg/s]
Water Heater Use Side Inlet Temperature [C]
Water Heater Use Side Outlet Temperature [C]
Water Heater Use Side Heat Transfer Rate [W]
Water Heater Use Side Heat Transfer Energy [J]
Water Heater Source Side Mass Flow Rate [kg/s]
Water Heater Source Side Inlet Temperature [C]
Water Heater Source Side Outlet Temperature [C]
Water Heater Source Side Heat Transfer Rate [W]
Water Heater Source Side Heat Transfer Energy [J]
Water Heater Off Cycle Parasitic Tank Heat Transfer Rate [W]
Water Heater Off Cycle Parasitic Tank Heat Transfer Energy [J]
Water Heater On Cycle Parasitic Tank Heat Transfer Rate [W]
Water Heater On Cycle Parasitic Tank Heat Transfer Energy [J]
Water Heater Total Demand Heat Transfer Rate [W]
Water Heater Total Demand Energy [J]
Water Heater Heating Rate [W]
Water Heater Heating Energy [J]
Water Heater Unmet Demand Heat Transfer Rate [W]
Water Heater Unmet Demand Heat Transfer Energy [J]
Water Heater Venting Heat Transfer Rate [W]
Water Heater Venting Heat Transfer Energy [J]
Water Heater Net Heat Transfer Rate [W]
Water Heater Net Heat Transfer Energy [J]
Water Heater Cycle On Count []
Water Heater Runtime Fraction []
Water Heater Part Load Ratio []
Water Heater Rate [W]
Water Heater Electric Power [W]
Water Heater Energy [J]
Water Heater Off Cycle Parasitic Rate [W]
Water Heater Off Cycle Parasitic Electric Power [W]
Water Heater Off Cycle Parasitic Energy [J]
Water Heater On Cycle Parasitic Rate [W]
Water Heater On Cycle Parasitic Electric Power [W]
Water Heater On Cycle Parasitic Energy [J]
Water Heater Water Volume Flow Rate [m3/s]
Water Heater Water Volume [m3]
Water Heater Mains Water Volume [m3]
WaterHeater:Stratified
Field: Name
Field: End-Use Subcategory
Field: Tank Volume
Field: Tank Height
Field: Tank Shape
Field: Tank Perimeter
Field: Maximum Temperature Limit
Field: Heater Priority Control
Field: Heater 1 Set Point Temperature Schedule Name
Field: Heater 1 Deadband Temperature Difference
Field: Heater 1 Capacity
Field: Heater 1 Height
Field: Heater 2 Set Point Temperature Schedule Name
Field: Heater 2 Deadband Temperature Difference
Field: Heater 2 Capacity
Field: Heater 2 Height
Field: Heater Fuel Type
Field: Heater Thermal Efficiency
Field: Off-Cycle Parasitic Fuel Consumption Rate
Field: Off-Cycle Parasitic Fuel Type
Field: Off-Cycle Parasitic Heat Fraction to Tank
Field: Off-Cycle Parasitic Height
Field: On-Cycle Parasitic Fuel Consumption Rate
Field: On-Cycle Parasitic Fuel Type
Field: On-Cycle Parasitic Heat Fraction to Tank
Field: On-Cycle Parasitic Height
Field: Ambient Temperature Indicator
Field: Ambient Temperature Schedule Name
Field: Ambient Temperature Zone
Field: Ambient Temperature Outdoor Air Node
Field: Uniform Skin Loss Coefficient Per Unit Area to Ambient Temperature
Field: Skin Loss Fraction to Zone
Field: Off-Cycle Flue Loss Coefficient to Ambient Temperature
Field: Off-Cycle Flue Loss Fraction to Zone
Field: Peak Use Flow Rate
Field: Use Flow Rate Fraction Schedule Name
Field: Cold Water Supply Temperature Schedule Name
Field: Use Side Inlet Node Name
Field: Use Side Outlet Node Name
Field: Use Side Effectiveness
Field: Use Side Inlet Height
Field: Use Side Outlet Height
Field: Source Side Inlet Node
Field: Source Side Outlet Node
Field: Source Side Effectiveness
Field: Source Side Inlet Height
Field: Source Side Outlet Height
Field: Inlet Mode
Field: Use Side Design Flow Rate
Field: Source Side Design Flow Rate
Field: Indirect Water Heating Recovery Time
Field: Number Of Nodes
Field: Additional Destratification Conductivity
Field: Node 1-10 Additional Loss Coefficient
Stratified Water Heater Outputs
Water Heater Tank Temperature [C]
Water Heater Final Tank Temperature [C]
Water Heater Heating Rate [W]
Water Heater Heating Energy [J]
Water Heater Cycle On Count []
Water Heater Runtime Fraction []
Water Heater Heater 1 Heating Rate [W]
Water Heater Heater 2 Heating Rate [W]
Water Heater Heater 1 Heating Energy [J]
Water Heater Heater 2 Heating Energy [J]
Water Heater Heater 1 Cycle On Count []
Water Heater Heater 2 Cycle On Count []
Water Heater Heater 1 Runtime Fraction []
Water Heater Heater 2 Runtime Fraction []
Water Heater Temperature Node 1-10 [C]
Water Heater Final Temperature Node 1-10 [C]
WaterHeater:Sizing
Field: WaterHeater Name
Field: Design Mode
Field: Time Storage Can Meet Peak Draw
Field: Time for Tank Recovery
Field: Nominal Tank Volume for Autosizing Plant Connections
Field: Number of Bedrooms
Field: Number of Bathrooms
Field: Storage Capacity per Person
Field: Recovery Capacity per Person
Field: Storage Capacity per Floor Area
Field: Recovery Capacity per Floor Area
Field: Number of Units
Field: Storage Capacity per Unit
Field: Recovery Capacity per Unit
Field: Storage Capacity per Collector Area
Field: Height Aspect Ratio
WaterHeater:HeatPump
Field: Name
Field: Availability Schedule Name
Field: Compressor Setpoint Temperature Schedule Name
Field: Dead Band Temperature Difference
Field: Condenser Water Inlet Node Name
Field: Condenser Water Outlet Node Name
Field: Condenser Water Flow Rate
Field: Evaporator Air Flow Rate
Field: Inlet Air Configuration
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Node Name
Field: Exhaust Air Node Name
Field: Inlet Air Temperature Schedule Name
Field: Inlet Air Humidity Schedule Name
Field: Inlet Air Zone Name
Field: Tank Object Type
Field: Tank Name
Field: Tank Use Side Inlet Node Name
Field: Tank Use Side Outlet Node Name
Field: DX Coil Object Type
Field: DX Coil Name
Field: Minimum Inlet Air Temperature for Compressor Operation
Field: Compressor Location
Field: Compressor Ambient Temperature Schedule Name
Field: Fan Object Type
Field: Fan Name
Field: Fan Placement
Field: On Cycle Parasitic Electric Load
Field: Off Cycle Parasitic Electric Load
Field: Parasitic Heat Rejection Location
Field: Inlet Air Mixer Node Name
Field: Outlet Air Splitter Node Name
Field: Inlet Air Mixer Schedule Name
Field: Control Sensor Location In Stratified Tank
Heat Pump Water Heater Outputs
Water Heater Compressor Part Load Ratio
Water Heater On Cycle Ancillary Electric Power [W]
Water Heater On Cycle Ancillary Electric Energy [J]
Water Heater Off Cycle Ancillary Electric Power [W]
Water Heater Off Cycle Ancillary Electric Energy [J]
Group – Condenser Equipment
Equipment Types
CoolingTower:SingleSpeed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Design Water Flow Rate
Field: Design Air Flow Rate
Field: U-Factor Times Area Value at Design Air Flow Rate
Field: Air Flow Rate in Free Convection Regime
Field: U-Factor Times Area Value at Free Convection Air Flow Rate
Field: Performance Input Method
Field: Nominal Capacity
Field: Free Convection Capacity
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Evaporation Loss Mode
Field: Evaporation Loss Factor
Field: Drift Loss Percent
Field: Blowdown Calculation Mode
Field: Blowdown Concentration Ratio
Field: Blowdown Makeup Water Usage Schedule Name
Field: Supply Water Storage Tank Name
Field: Outdoor Air Inlet Node Name
Field: Capacity Control
Field: Number of Cells
Field: Cell Control
Field: Cell Minimum Water Flow Rate Fraction
Field: Cell Maximum Water Flow Rate Fraction
Single Speed Cooling Tower Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Cooling Tower Basin Heater Electric Power [W]
Cooling Tower Basin Heater Electric Energy [J]
Cooling Tower Make Up Water Volume Flow Rate [m3/s]
Cooling Tower Make Up Water Volume [m3]
Cooling Tower Water Evaporation Volume Flow Rate [m3/s]
Cooling Tower Water Evaporation Volume [m3]
Cooling Tower Water Drift Volume Flow Rate [m3/s]
Cooling Tower Water Drift Volume [m3]
Cooling Tower Water Blowdown Volume Flow Rate [m3/s]
Cooling Tower Water Blowdown Volume [m3]
Cooling Tower Make Up Mains Water Volume [m3]
Cooling Tower Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Storage Tank Water Volume [m3]
Cooling Tower Starved Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Starved Storage Tank Water Volume [m3]
Cooling Tower Fan Cycling Ratio []
Cooling Tower Bypass Fraction []
Cooling Tower Operating Cells Count []
CoolingTower:TwoSpeed
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Design Water Flow Rate
Field: Air Flow Rate at High Fan Speed
Field: U-Factor Times Area Value at High Fan Speed
Field: Air Flow Rate at Low Fan Speed
Field: U-Factor Times Area Value at Low Fan Speed
Field: Air Flow Rate in Free Convection Regime
Field: U-Factor Times Area Value at Free Convection Air Flow Rate
Field: Performance Input Method
Field: High Speed Nominal Capacity
Field: Low Speed Nominal Capacity
Field: Free Convection Capacity
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Evaporation Loss Mode
Field: Evaporation Loss Factor
Field: Drift Loss Percent
Field: Blowdown Calculation Mode
Field: Blowdown Concentration Ratio
Field: Blowdown Makeup Water Usage Schedule Name
Field: Supply Water Storage Tank Name
Field: Outdoor Air Inlet Node Name
Field: Number of Cells
Field: Cell Control
Field: Cell Minimum Water Flow Rate Fraction
Field: Cell Maximum Water Flow Rate Fraction
Two Speed Cooling Tower Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Cooling Tower Basin Heater Electric Power [W]
Cooling Tower Basin Heater Electric Energy [J]
Cooling Tower Make Up Water Volume Flow Rate [m3/s]
Cooling Tower Make Up Water Volume [m3]
Cooling Tower Water Evaporation Volume Flow Rate [m3/s]
Cooling Tower Water Evaporation Volume [m3]
Cooling Tower Water Drift Volume Flow Rate [m3/s]
Cooling Tower Water Drift Volume [m3]
Cooling Tower Water Blowdown Volume Flow Rate [m3/s]
Cooling Tower Water Blowdown Volume [m3]
Cooling Tower Make Up Mains Water Volume [m3]
Cooling Tower Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Storage Tank Water Volume [m3]
Cooling Tower Starved Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Starved Storage Tank Water Volume [m3]
Cooling Tower Fan Cycling Ratio []
Cooling Tower Operating Cells Count []
Cooling Tower Fan Speed Level []
Cooling Tower:Variable Speed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Model Type
Field: Model Coefficient Name
Field: Design Inlet Air Wet-Bulb Temperature
Field: Design Approach Temperature
Field: Design Range Temperature
Field: Design Water Flow Rate
Field: Design Air Flow Rate
Field: Design Fan Power
Field: Fan Power Ratio Function of Air Flow Rate Ratio Curve Name
Field: Minimum Air Flow Rate Ratio
Field: Fraction of Tower Capacity in Free Convection Regime
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Evaporation Loss Mode
Field: Evaporation Loss Factor
Field: Drift Loss Percent
Field: Blowdown Calculation Mode
Field: Blowdown Concentration Ratio
Field: Blowdown Makeup Water Usage Schedule Name
Field: Supply Water Storage Tank Name
Field: Outdoor Air Inlet Node Name
Field: Number of Cells
Field: Cell Control
Field: Cell Minimum Water Flow Rate Fraction
Field: Cell Maximum Water Flow Rate Fraction
Field: Sizing Factor
Variable Speed Cooling Tower Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Fan Part Load Ratio []
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Cooling Tower Air Flow Rate Ratio []
Cooling Tower Basin Heater Electric Power [W]
Cooling Tower Basin Heater Electric Energy [J]
Cooling Tower Make Up Water Volume Flow Rate [m3/s]
Cooling Tower Make Up Water Volume [m3]
Cooling Tower Water Evaporation Volume Flow Rate [m3/s]
Cooling Tower Water Evaporation Volume [m3]
Cooling Tower Water Drift Volume Flow Rate [m3/s]
Cooling Tower Water Drift Volume [m3]
Cooling Tower Water Blowdown Volume Flow Rate [m3/s]
Cooling Tower Water Blowdown Volume [m3]
Cooling Tower Make Up Mains Water Volume [m3]
Cooling Tower Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Storage Tank Water Volume [m3]
Cooling Tower Starved Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Starved Storage Tank Water Volume [m3]
Cooling Tower Operating Cells Count []
CoolingTowerPerformance:CoolTools
Field: Name
Field: Minimum Inlet Air Wet-Bulb Temperature
Field: Maximum Inlet Air Wet-Bulb Temperature
Field: Minimum Range Temperature
Field: Maximum Range Temperature
Field: Minimum Approach Temperature
Field: Maximum Approach Temperature
Field: Minimum Water Flow Rate Ratio
Field: Maximum Water Flow Rate Ratio
Field: Coefficient 1 to 35
CoolingTowerPerformance:CoolTools Outputs
CoolingTowerPerformance:YorkCalc
Field: Name
Field: Minimum Inlet Air Wet-Bulb Temperature
Field: Maximum Inlet Air Wet-Bulb Temperature
Field: Minimum Range Temperature
Field: Maximum Range Temperature
Field: Minimum Approach Temperature
Field: Maximum Approach Temperature
Field: Minimum Water Flow Rate Ratio
Field: Maximum Water Flow Rate Ratio
Field: Maximum Liquid to Gas Ratio
Field: Coefficient 1 to 27
CoolingTowerPerformance:YorkCalc Outputs
EvaporativeFluidCooler:SingleSpeed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Design Air Flow Rate
Field: Fan Power at Design Air Flow Rate
Field: Design Spray Water Flow Rate
Field: Performance Input Method
Field: Outdoor Air Inlet Node Name
Field: Standard Design Capacity
Field: U-factor Times Area Value at Design Air Flow Rate
Field: Design Water Flow Rate
Field: User Specified Design Capacity
Field: Design Entering Water Temperature
Field: Design Entering Air Temperature
Field: Design Entering Air Wet-bulb Temperature
Field: Capacity Control
Field: Sizing Factor
Field: Evaporation Loss Mode
Field: Evaporation Loss Factor
Field: Drift Loss Percent
Field: Blowdown Calculation Mode
Field: Blowdown Concentration Ratio
Field: Blowdown Makeup Water Usage Schedule Name
Field: Supply Water Storage Tank Name
Single Speed Evaporative Fluid Cooler Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Cooling Tower Bypass Fraction []
Cooling Tower Make Up Water Volume Flow Rate [m3/s]
Cooling Tower Make Up Water Volume [m3]
Cooling Tower Water Evaporation Volume Flow Rate [m3/s]
Cooling Tower Water Evaporation Volume [m3]
Cooling Tower Water Drift Volume Flow Rate [m3/s]
Cooling Tower Water Drift Volume [m3]
Cooling Tower Water Blowdown Volume Flow Rate [m3/s]
Cooling Tower Water Blowdown Volume [m3]
Cooling Tower Make Up Mains Water Volume [m3]
Cooling Tower Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Storage Tank Water Volume [m3]
Cooling Tower Starved Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Starved Storage Tank Water Volume [m3]
EvaporativeFluidCooler:TwoSpeed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Flow Rate at High Fan Speed
Field: Fan Power at High Fan Speed
Field: Air Flow Rate at Low Fan Speed
Field: Fan Power at Low Fan Speed
Field: Design Spray Water Flow Rate
Field: Performance Input Method
Field: Outdoor Air Inlet Node Name
Field: High-Speed Standard Design Capacity
Field: Low-Speed Standard Design Capacity
Field: U-factor Times Area Value at High Fan Speed
Field: U-factor Times Area Value at Low Fan Speed
Field: Design Water Flow Rate
Field: High-Speed User Specified Design Capacity
Field: Low-Speed User Specified Design Capacity
Field: Design Entering Water Temperature
Field: Design Entering Air Temperature
Field: Design Entering Air Wet-bulb Temperature
Field: Sizing Factor
Field: Evaporation Loss Mode
Field: Evaporation Loss Factor
Field: Drift Loss Percent
Field: Blowdown Calculation Mode
Field: Blowdown Concentration Ratio
Field: Blowdown Makeup Water Usage Schedule Name
Field: Supply Water Storage Tank Name
Two Speed Evaporative Fluid Cooler Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
Cooling Tower Make Up Water Volume Flow Rate [m3/s]
Cooling Tower Make Up Water Volume [m3]
Cooling Tower Water Evaporation Volume Flow Rate [m3/s]
Cooling Tower Water Evaporation Volume [m3]
Cooling Tower Water Drift Volume Flow Rate [m3/s]
Cooling Tower Water Drift Volume [m3]
Cooling Tower Water Blowdown Volume Flow Rate [m3/s]
Cooling Tower Water Blowdown Volume [m3]
Cooling Tower Make Up Mains Water Volume [m3]
Cooling Tower Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Storage Tank Water Volume [m3]
Cooling Tower Starved Storage Tank Water Volume Flow Rate [m3/s]
Cooling Tower Starved Storage Tank Water Volume [m3]
FluidCooler:SingleSpeed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Performance Input Method
Field: U-factor Times Area Value at Design Air Flow Rate
Field: Nominal Capacity
Field: Design Entering Water Temperature
Field: Design Entering Air Temperature
Field: Design Entering Air Wet-bulb Temperature
Field: Design Water Flow Rate
Field: Design Air Flow Rate
Field: Fan Power at Design Air Flow Rate
Field: Outdoor Air Inlet Node Name
Single Speed Fluid Cooler Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
FluidCooler:TwoSpeed
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Performance Input Method
Field: U-factor Times Area Value at High Fan Speed
Field: U-factor Times Area Value at Low Fan Speed
Field: High Speed Nominal Capacity
Field: Low Speed Nominal Capacity
Field: Design Entering Water Temperature
Field: Design Entering Air Temperature
Field: Design Entering Air Wet-bulb temperature
Field: Design Water Flow Rate
Field: Air Flow Rate at High Fan Speed
Field: Fan Power at High Fan Speed
Field: Air Flow Rate at Low Fan Speed
Field: Fan Power at Low Fan Speed
Field: Outdoor Air Inlet Node Name
Two Speed Fluid Cooler Outputs
Cooling Tower Fan Electric Power [W]
Cooling Tower Fan Electric Energy [J]
Cooling Tower Heat Transfer Rate [W]
Cooling Tower Inlet Temperature [C]
Cooling Tower Outlet Temperature [C]
Cooling Tower Mass Flow Rate [kg/s]
GroundHeatExchanger:Vertical
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Maximum Flow Rate
Field: Number of Bore Holes
Field: Bore Hole Length
Field: Bore Hole Radius
Field: Ground Thermal Conductivity
FieldSet: Ground Thermal Heat Capacity
Field: Ground Temperature
Field: Design Flow Rate
Field: Grout Thermal Conductivity
Field: Pipe Thermal Conductivity
Field: Pipe Out Diameter
Field: U-Tube Distance
Field: Pipe Thickness
Field: Maximum Length of Simulation
Field: G-Function Reference Ratio
Field: Number of Data Pairs of the G Function
Field: G-Function Ln(T/Ts) Value
Field: G-Function ‘G’ Value
Vertical Ground Heat Exchanger Outputs
Ground Heat Exchanger Average Borehole Temperature [C]
Ground Heat Exchanger Heat Transfer Rate [W]
Ground Heat Exchanger Inlet Temperature [C]
Ground Heat Exchanger Outlet Temperature [C]
Ground Heat Exchanger Mass Flow Rate [kg/s]
Ground Heat Exchanger Average Fluid Temperature [C]
GroundHeatExchanger:Pond
Field: Name
Field: Fluid Inlet Node Name
Field: Fluid Outlet Node Name
Field: Pond Depth
Field: Pond Area
Field: Hydronic Tubing Inside Diameter
Field: Hydronic Tubing Outside Diameter
Field: Hydronic Tubing Thermal Conductivity
Field: Ground Thermal Conductivity
Field: Number of Tubing Circuits
Field: Length of Each Tubing Circuit
Pond Heat Exchanger Outputs
Pond Heat Exchanger Heat Transfer Rate [W]
Pond Heat Exchanger Heat Transfer Energy [J]
Pond Heat Exchanger Mass Flow Rate [kg/s]
Pond Heat Exchanger Inlet Temperature [C]
Pond Heat Exchanger Outlet Temperature [C]
Pond Heat Exchanger Bulk Temperature [C]
GroundHeatExchanger:Surface
Field: Name
Field: Construction Name
Field: Fluid Inlet Node Name
Field: Fluid Outlet Node Name
Field: Hydronic Tubing Inside Diameter
Field: Number of Tubing Circuits
Field: Hydronic Tube Spacing
Field: Surface Length
Field: Surface Width
Field: Lower Surface Environment
Surface Ground Heat Exchanger Outputs
Ground Heat Exchanger Heat Transfer Rate [W]
Ground Heat Exchanger Surface Heat Transfer Rate [W]
Ground Heat Exchanger Heat Transfer Energy [J]
Ground Heat Exchanger Mass Flow Rate [kg/s]
Ground Heat Exchanger Inlet Temperature [C]
Ground Heat Exchanger Outlet Temperature [C]
Ground Heat Exchanger Top Surface Temperature [C]
Ground Heat Exchanger Bottom Surface Temperature [C]
Ground Heat Exchanger Top Surface Heat Transfer Energy per Area [J/m2]
Ground Heat Exchanger Bottom Surface Heat Transfer Energy per Area [J/m2]
Ground Heat Exchanger Surface Heat Transfer Energy [J]
Ground Heat Exchanger Source Temperature [C]
GroundHeatExchanger:HorizontalTrench
Horizontal Trench Ground Heat Exchanger Outputs
Ground Heat Exchanger Mass Flow Rate [kg/s]
Ground Heat Exchanger Inlet Temperature [C]
Ground Heat Exchanger Outlet Temperature [C]
Ground Heat Exchanger Fluid Heat Transfer Rate [W]
HeatExchanger:FluidToFluid
Field: Name
Field: Availability Schedule Name
Field: Loop Demand Side Inlet Node Name
Field: Loop Demand Side Outlet Node Name
Field: Loop Demand Side Design Flow Rate
Field: Loop Supply Side Inlet Node Name
Field: Loop Supply Side Outlet Node Name
Field: Loop Supply Side Design Flow Rate
Field: Heat Exchange Model Type
Field: Heat Exchanger U-Factor Times Area Value
Field: Control Type
Field: Heat Exchanger Setpoint Node Name
Field: Minimum Temperature Difference to Activate Heat Exchanger
Field: Heat Transfer Metering End Use Type
Field: Component Override Loop Supply Side Inlet Node Name
Field: Component Override Loop Demand Side Inlet Node Name
Field: Component Override Cooling Control Temperature Mode
Field: Sizing Factor
Field: Operation Minimum Temperature Limit
Field: Operation Maximum Temperature Limit
Fluid to Fluid Heat Exchanger Outputs
Fluid Heat Exchanger Heat Transfer Rate [W]
Fluid Heat Exchanger Heat Transfer Energy [J]
Fluid Heat Exchanger Loop Supply Side Mass Flow Rate [kg/s]
Fluid Heat Exchanger Loop Supply Side Inlet Temperature [C]
Fluid Heat Exchanger Loop Supply Side Outlet Temperature [C]
Fluid Heat Exchanger Loop Demand Side Mass Flow Rate [kg/s]
Fluid Heat Exchanger Loop Demand Side Inlet Temperature [C]
Fluid Heat Exchanger Loop Demand Side Outlet Temperature [C]
Fluid Heat Exchanger Operation Status [0=off, 1= on]
Fluid Heat Exchanger Effectiveness [ ]
Group – Plant-Condenser Flow Control
Connector:Splitter, Connector:Mixer
Connector:Splitter
Field: Name
Field: Inlet Branch Name
Field: Outlet Branch Name
Connector:Mixer
Field: Name
Field: Outlet Branch Name
Field: Inlet Branch Name
TemperingValve
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Stream 2 Source Node Name
Field: Temperature Setpoint Node Name
Field: Pump Outlet Node Name
Tempering Valve Outputs
Group – Air Distribution
AirLoopHVAC
Field: Name
Field: Controller List Name
Field: Availability Manager List Name
Field: Design Supply Air Flow Rate
Field: Branch List Name
Field: Connector List Name
Field: Supply Side Inlet Node Name
Field: Demand Side Outlet Node Name
Field: Demand Side Inlet Node Names
Field: Supply Side Outlet Node Names
AirLoopHVAC Outputs
Air System Simulation Cycle On Off Status
HVAC System Solver Iteration Count []
Air System Solver Iteration Count []
Air System Simulation Maximum Iteration Count []
Air System Simulation Iteration Count []
Air System Component Model Simulation Calls []
Outdoor Air Ventilation Outputs
Ventilation Flow Outputs
Zone Mechanical Ventilation Mass Flow Rate [kg/s]
Zone Mechanical Ventilation Mass [kg]
Zone Mechanical Ventilation Standard Density Volume Flow Rate [m3/s]
Zone Mechanical Ventilation Standard Density Volume [m3]
Zone Mechanical Ventilation Current Density Volume Flow Rate [m3/s]
Zone Mechanical Ventilation Current Density Volume [m3]
Zone Mechanical Ventilation Air Changes per Hour [ach]
Ventilation Load Reports
Zone Mechanical Ventilation Cooling Load Increase Due to Overheating Energy [J]
Zone Mechanical Ventilation Heating Load Increase Due to Overcooling Energy [J]
Zone Mechanical Ventilation Cooling Load Decrease Energy [J]
Zone Mechanical Ventilation Heating Load Decrease[J]
Zone Mechanical Ventilation No Load Heat Removal Energy [J]
Zone Mechanical Ventilation No Load Heat Addition Energy [J]
Systems Level Reporting
System Loads Outputs
Air System Total Heating Energy
Air System Total Cooling Energy
System Energy Use Outputs
Air System Hot Water Energy
Air System Steam Energy
Air System Chilled Water Energy
Air System Electric Energy
Air System Gas Energy
Air System Water Volume
System Component Loads Outputs
Air System Fan Air Heating Energy
Air System Cooling Coil Total Cooling Energy
Air System Heating Coil Total Heating Energy
Air System Heat Exchanger Total Heating Energy
Air System Heat Exchanger Total Cooling Energy
Air System Humidifier Total Heating Energy
Air System Evaporative Cooler Total Cooling Energy
Air System Desiccant Dehumidifier Total Cooling Energy
Air System Solar Collector Total Heating Energy
Air System Solar Collector Total Cooling Energy
Air System User Defined Air Terminal Total Heating Energy
Air System User Defined Air Terminal Total Cooling Energy
System Component Energy Use Outputs
Air System Fan Electric Energy
Air System Heating Coil Hot Water Energy
Air System Cooling Coil Chilled Water Energy
Air System DX Heating Coil Electric Energy
Air System DX Cooling Coil Electric Energy
Air System Heating Coil Electric Energy
Air System Heating Coil Gas Energy
Air System Heating Coil Steam Energy
Air System Humidifier Electric Energy
Air System Evaporative Cooler Electric Energy
Air System Desiccant Dehumidifier Electric Energy
Overall Air Loop Syntax
AirLoopHVAC:ControllerList
Field: Name
Field Set (Object Type, Controller Name) up to 8
Field: Controller Object Type
Field: Controller Name
AvailabilityManagerAssignmentList
Field: Name
Field Set (Availability Manager Object Type, Name)
Field: Availability Manager Object Type
Field: Availability Manager Name
AirLoopHVAC:OutdoorAirSystem
Field: Name
Field: Name: Controller List Name
Field: Outdoor Air Equipment List Name
Field: Availability Manager List Name
Outdoor Air System Outputs
AirLoopHVAC:OutdoorAirSystem:EquipmentList
Field: Name
Field Set (Component Object Type,, Component Name) up to 8
Field: Component Object Type
Field: Component Name
OutdoorAir:Node
Field: Name
Field: Height Above Ground
Outdoor Air Node outputs:
OutdoorAir:NodeList
Field: Node or NodeList name
OutdoorAir:Mixer
Field: Name
Field: Mixed Air Node Name
Field: Outdoor Air Stream Node Name
Field: Relief Air Stream Node Name
Field: Return Air Stream Node Name
Group – Airflow Network
Overview
Summary of Objects
Airflow Network Example Files (included in the installation)
What the Airflow Network Model Can and Cannot Do
Can Do
Cannot Do or Restricted
AirflowNetwork:SimulationControl
Field: Name
Field: AirflowNetwork Control
Field: Wind Pressure Coefficient Type
Field: AirflowNetwork Wind Pressure Coefficient Array Name
Field: Height Selection for Local Wind Pressure Calculation
Field: Building Type
Field: Maximum Number of Iterations
Field: Initialization Type
Field: Relative Airflow Convergence Tolerance
Field: Absolute Airflow Convergence Tolerance
Field: Convergence Acceleration Limit
Field: Azimuth Angle of Long Axis of Building
Field: Ratio of Building Width Along Short Axis to Width Along Long Axis
AirflowNetwork:Multizone:Zone
Field: Zone Name
Field: Ventilation Control Mode
Field: Ventilation Control Zone Temperature Setpoint Schedule Name
Field: Minimum Venting Open Factor
Field: Indoor and Outdoor Temperature Difference Lower Limit For Maximum Venting Open Factor
Field: Indoor and Outdoor Temperature Difference Upper Limit for Minimun Venting Open Factor
Field: Indoor and Outdoor Enthalpy Difference Lower Limit For Maximum Venting Open Factor
Field: Indoor and Outdoor Enthalpy Difference Upper Limit for Minimun Venting Open Factor
Field: Venting Availability Schedule Name
AirflowNetwork:Multizone:Surface
Field: Surface Name
Field: Leakage Component Name
Field: External Node Name
Field: Window/Door Opening Factor, or Crack Factor
Field: Ventilation Control Mode
Field: Ventilation Control Zone Temperature Setpoint Schedule Name
Field: Minimum Venting Open Factor
Field: Indoor and Outdoor Temperature Difference Lower Limit For Maximum Venting Open Factor
Field: Indoor and Outdoor Temperature Difference Upper Limit for Minimun Venting Open Factor
Field: Indoor and Outdoor Enthalpy Difference Lower Limit For Maximum Venting Open Factor
Field: Indoor and Outdoor Enthalpy Difference Upper Limit for Minimun Venting Open Factor
Field: Venting Availability Schedule Name
AirflowNetwork:MultiZone:ReferenceCrackConditions
Field: Name
Field: Reference Temperature
Field: Reference Barometric Pressure
Field: Reference Humidity Ratio
AirflowNetwork:MultiZone:Surface:Crack
Field: Name
Field: Air Mass Flow Coefficient at Reference Conditions
Field: Air Mass Flow Exponent
Field: Reference Crack Conditions
AirflowNetwork:MultiZone:Surface:EffectiveLeakageArea
Field: Name
Field: Effective Leakage Area
Field: Discharge Coefficient
Field: Reference Pressure Difference
Field: Air Mass Flow Exponent
AirflowNetwork:MultiZone:Component:DetailedOpening
Field: Name
Field: Air Mass Flow Coefficient When Opening is Closed
Field: Air Mass Flow Exponent When Opening Is Closed
Field: Type of Rectanguler Large Vertical Opening (LVO)
Field: Extra Crack Length or Height of Pivoting Axis
Field: Number of Sets of Opening Factor Data
Field Group: Opening Factor, Discharge Coefficient, Width Factor, Height Factor, Start Height Factor
Field: Opening Factor 11
Field: Discharge Coefficient for Opening Factor 1
Field: Width Factor for Opening Factor 1
Field: Height Factor for Opening Factor 1
Field: Start Height Factor for Opening Factor 1
Field: Opening Factor
Field: Discharge Coefficient for Opening Factor
Field: Width Factor for Opening Factor
Field: Height Factor for Opening Factor
Field: Start Height Factor for Opening Factor
AirflowNetwork:MultiZone:Component:HorizontalOpening
Field: Name
Field: Air Mass Flow Coefficient When Opening is Closed
Field: Air Mass Flow Exponent When Opening is Closed
Field: Sloping Plane Angle
Field: Discharge Coefficient
AirflowNetwork:MultiZone:Component:SimpleOpening
Field: Name
Field: Air Mass Flow Coefficient When Opening is Closed
Field: Air Mass Flow Exponent When Opening is Closed
Field: Minimum Density Difference for Two-Way Flow
Field: Discharge Coefficient
AirflowNetwork:MultiZone:Component:ZoneExhaustFan
Field: Name
Field: Air Mass Flow Coefficient When the Zone Exhaust Fan is Off at Reference Conditions
Field: Air Mass Flow Exponent When the Zone Exhaust Fan is Off
Field: Reference Crack Conditions
AirflowNetwork:MultiZone:ExternalNode
Field: Name
Field: External Node Height
Field: Wind Pressure Coefficient Values Object Name
AirflowNetwork:MultiZone:WindPressureCoefficientArray
Field: Name
Field: Wind Direction 1-Wind Direction N
AirflowNetwork:MultiZone:WindPressureCoefficientValues
Field: Name
Field: WindPressureCoefficientArray Name
Field: Wind Pressure Coefficient Value 1 to Wind Pressure Coefficient Value N
Obtaining WPC values
AirflowNetwork:Distribution:Node
Field: Name
Field:Component Name or Node Name
Field: Component Object Type or Node Type
Field: Node Height
AirflowNetwork:Distribution:Component:Leak
Field: Name
Field: Air Mass Flow Coefficient
Field: Air Mass Flow Exponent
AirflowNetwork:Distribution:Component:LeakageRatio
Field: Name
Field: Effective Leakage Ratio
Field: Maximum Flow Rate
Field: Reference Pressure Difference
Field: Air Mass Flow Exponent
AirflowNetwork:Distribution:Component:Duct
Field: Name
Field: Duct Length
Field: Hydraulic Diameter
Field: Cross Section Area
Field: Surface Roughness
Field: Coefficient for Local Dynamic Loss Due to fitting
Field: Overall Heat Transmittance Coefficient (U-Factor) from Air to Air
Field: Overall Moisture Transmittance Coefficient from Air to Air
AirflowNetwork:Distribution:Component:Fan
Field: Fan Name
Field: Supply Fan Object Type
AirflowNetwork:Distribution:Component:Coil
Field: Coil Name
Field: Coil Object Type
Field: Air Path Length
Field: Air Path Hydraulic Diameter
AirflowNetwork:Distribution:Component:HeatExchanger
Field: Heat Exchanger Name
Field: Heat Exchanger Object Type
Field: Air Path Length
Field: Air Path Hydraulic Diameter
AirflowNetwork:Distribution:Component:TerminalUnit
Field: Terminal Unit Name
Field: Terminal Unit Object Type
Field: Air Path Length
Field: Air Path Hydraulic Diameter
AirflowNetwork:Distribution:Component:ConstantPressureDrop
Field: Name
Field: Pressure Difference across the Component
AirflowNetwork:Distribution:Linkage
Field: Name
Field: Node 1 Name
Field: Node 2 Name
Field: Component Name
Field: Thermal Zone Name
Airflow Network Outputs
AFN Node Temperature [C]
AFN Node Humidity Ratio [kgWater/kgDryAir]
AFN Node Total Pressure [Pa]
AFN Node CO2 Concentration [ ppm]
AFN Node Generic Air Contaminant Concentration [ppm]
AFN Zone Average Pressure [Pa]
AFN Zone On Cycle Pressure [Pa]
AFN Zone Off Cycle Pressure [Pa]
AFN Node Wind Pressure [Pa]
AFN Linkage Node 1 to Node 2 Mass Flow Rate [kg/s]
AFN Linkage Node 2 to Node 1 Mass Flow Rate [kg/s]
AFN Linkage Node 1 to 2 Average Mass Flow Rate [kg/s]
AFN Linkage Node 2 to 1 Average Mass Flow Rate [kg/s]
AFN Linkage Node 1 to Node 2 Volume Flow Rate [m3/s]
AFN Linkage Node 2 to Node 1 Volume Flow Rate [m3/s]
AFN Linkage Node 1 to 2 Average Volume Flow Rate [m3/s]
AFN Linkage Node 2 to 1 Average Volume Flow Rate [m3/s]
AFN Linkage Node 1 to Node 2 Pressure Difference [Pa]
AFN Surface Average Pressure Difference [Pa]
AFN Surface On Cycle Pressure Difference [Pa]
AFN Surface Off Cycle Pressure Difference [Pa]
AFN Surface Venting Window or Door Opening Factor []
AFN Surface Venting Window or Door Opening Modulation Multiplier []
AFN Surface Venting Inside Setpoint Temperature [C]
AFN Surface Venting Availability Status [ ]
AFN Zone Infiltration Sensible Heat Gain Rate [W]
AFN Zone Infiltration Sensible Heat Gain Energy [J]
AFN Zone Infiltration Sensible Heat Loss Rate [W]
AFN Zone Infiltration Sensible Heat Loss Energy [J]
AFN Zone Infiltration Latent Heat Gain Rate [W]
AFN Zone Infiltration Latent Heat Gain Energy [J]
AFN Zone Infiltration Latent Heat Loss Rate [W]
AFN Zone Infiltration Latent Heat Loss Energy [J]
AFN Zone Mixing Sensible Heat Gain Rate [W]
AFN Zone Mixing Sensible Heat Loss Rate [W]
AFN Zone Mixing Sensible Heat Gain Energy [J]
AFN Zone Mixing Sensible Heat Loss Energy [J]
AFN Zone Mixing Latent Heat Gain Rate [W]
AFN Zone Mixing Latent Heat Gain Energy [J]
AFN Zone Mixing Latent Heat Loss Rate [W]
AFN Zone Mixing Latent Heat Loss Energy [J]
AFN Zone Mixing CO2 Mass Flow Rate [kg/s]
AFN Zone Mixing Generic Air Contaminant Mass Flow Rate [kg/s]
AFN Zone Duct Leaked Air Sensible Heat Gain Rate [W]
AFN Zone Duct Leaked Air Sensible Heat Gain Energy [J]
AFN Zone Duct Leaked Air Sensible Heat Loss Rate [W]
AFN Zone Duct Leaked Air Sensible Heat Loss Energy [J]
AFN Zone Duct Leaked Air Latent Heat Gain Rate [W]
AFN Zone Duct Leaked Air Latent Heat Gain Energy [J]
AFN Zone Duct Leaked Air Latent Heat Loss Rate [W]
AFN Zone Duct Leaked Air Latent Heat Loss Energy [J]
AFN Zone Duct Conduction Sensible Heat Gain Rate [W]
AFN Zone Duct Conduction Sensible Heat Gain Energy [J]
AFN Zone Duct Conduction Sensible Heat Loss Rate [W]
AFN Zone Duct Conduction Sensible Heat Loss Energy [J]
AFN Zone Duct Diffusion Latent Heat Gain Rate [W]
AFN Zone Duct Diffusion Latent Heat Gain Energy [J]
AFN Zone Duct Diffusion Latent Heat Loss Rate [W]
AFN Zone Duct Diffusion Latent Heat Loss Energy [J]
AFN Distribution Sensible Heat Gain Rate [W]
AFN Distribution Sensible Heat Gain Energy [J]
AFN Distribution Sensible Heat Loss Rate [W]
AFN Distribution Sensible Heat Loss Energy [J]
AFN Distribution Latent Heat Gain Rate [W]
AFN Distribution Latent Heat Gain Energy [J]
AFN Distribution Latent Heat Loss Rate [W]
AFN Distribution Latent Heat Loss Energy [J]
AFN Zone Infiltration Sensible Heat Gain Energy [J]“afn-zone-infiltration-sensible-heat-loss-energy-j-1
AFN Zone Infiltration Volume [m3]
AFN Zone Infiltration Mass [kg]
AFN Zone Infiltration Air Change Rate [ach]
AFN Zone Mixing Volume [m3]
AFN Zone Mixing Mass [kg]
AFN Zone Mixing Mass Flow Rate [kg/s]
AFN Zone Outdoor Air CO2 Mass Flow Rate [kg/s]
AFN Zone Outdoor Air Generic Air Contaminant Mass Flow Rate [kg/s]
AFN Zone Outdoor Air Mass Flow Rate [kg/s]
AFN Zone Total CO2 Mass Flow Rate [kg/s]
AFN Zone Total Generic Air Contaminant Mass Flow Rate [kg/s]
Group – Zone Equipment
ZoneHVAC:AirDistributionUnit
Field: Name
Field: Air Distribution Unit Outlet Node Name
Field: Air Terminal Object Type
Field: Air Terminal Name
Field: Nominal Upstream Leakage Fraction
Field: Constant Downstream Leakage Fraction
ZoneHVAC:EquipmentConnections
Field: Zone Name
Field: Zone Conditioning Equipment List Name
Field: Zone Air Inlet Node or NodeList Name
Field: Zone Air Exhaust Node or NodeList Name
Field: Zone Air Node Name
Field: Zone Return Air Node Name
ZoneHVAC:EquipmentList
Field: Name
Field Set (Zone Equipment: Object Type, Name, Cooling Sequence, Heating or No-Load Sequence)
Field: Zone Equipment Object Type
Field: Zone Equipment Name
Field: Zone Equipment Cooling Sequence
Field: Zone Equipment Heating or No-Load Sequence
Group – Air Distribution Equipment
AirTerminal:SingleDuct:Uncontrolled
Field: Name
Field: Availability Schedule Name
Field: Zone Supply Air Node Name
Field: Maximum Air Flow Rate
Single Duct Uncontrolled AirTerminal Outputs
Zone Air Terminal Sensible Heating Energy [J]
Zone Air Terminal Sensible Heating Rate [W]
Zone Air Terminal Sensible Cooling Energy [J]
Zone Air Terminal Sensible Cooling Rate [W]
AirTerminal:SingleDuct:ConstantVolume:Reheat
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Air Inlet Node Name
Field: Maximum Air Flow Rate
Control Fields:
Field: Hot Water or Steam Inlet Node Name
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Convergence Tolerance
Field: Maximum Reheat Air Temperature
Single Duct Constant Volume Reheat AirTerminal Outputs
AirTerminal:SingleDuct:VAV:Reheat
Field: Name
Field: Availability Schedule Name
Field: Damper Air Outlet Node Name
Field: Air Inlet Node Name
Field: Maximum Air Flow Rate
Field: Zone Minimum Air Flow Method
Field: Constant Minimum Air Flow Fraction
Field: Fixed Minimum Air Flow Rate
Field: Minimum Air Flow Fraction Schedule Name
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Air Outlet Node Name
Field: Convergence Tolerance
Field: Damper Heating Action
Control Fields for Maximum Flow During Reheat:
Field: Maximum Flow per Zone Floor Area During Reheat
Field: Maximum Flow Fraction During Reheat
Field: Maximum Reheat Air Temperature
Field: Design Specification Outdoor Air Object Name
Single Duct VAV Reheat AirTerminal Outputs
Zone Air Terminal VAV Damper Position []
Zone Air Terminal Minimum Air Flow Fraction []
Zone Air Terminal Outdoor Air Volume Flow Rate [m3/s]
AirTerminal:SingleDuct:VAV:Reheat:VariableSpeedFan
Field: Name
Field: Availability Schedule Name
Field: Maximum Cooling Air Flow Rate
Field: Maximum Heating Air Flow Rate
Field: Zone Minimum Air Flow Fraction
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Heating Coil Air Inlet Node Name
Field: Hot Water or Steam Inlet Node Name
Field: Fan Object Type
Field: Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Heating Convergence Tolerance
Single Duct VAV Reheat Variable Speed Fan AirTerminal Outputs
Zone Air Terminal VAV Damper Position
AirTerminal:SingleDuct:VAV:HeatAndCool:Reheat
Field: Name
Field: Availability Schedule Name
Field: Damper Air Outlet Node Name
Field: Air Inlet Node Name
Field: Maximum Air Flow Rate
Field: Zone Minimum Air Flow Fraction
Control Fields:
Field: Hot Water or Steam Inlet Node Name
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Air Outlet Node Name
Field: Convergence Tolerance
Field: Maximum Reheat Air Temperature
Single Duct VAV Heat and Cool Reheat AirTerminal Outputs
Zone Air Terminal VAV Damper Position []
AirTerminal:SingleDuct:VAV:NoReheat
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Air Inlet Node Name
Field: Maximum Air Flow Rate
Field: Zone Minimum Air Flow Method
Field: Constant Minimum Air Flow Fraction
Field: Fixed Minimum Air Flow Rate
Field: Minimum Air Flow Fraction Schedule Name
Field: Design Specification Outdoor Air Object Name
Single Duct VAV NoReheat AirTerminal Outputs
Zone Air Terminal VAV Damper Position []
Zone Air Terminal Outdoor Air Volume Flow Rate [m3/s]
AirTerminal:SingleDuct:VAV:HeatAndCool:NoReheat
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Air Inlet Node Name
Field: Maximum Air Flow Rate
Field: Zone Minimum Air Flow Fraction
Single Duct VAV Heat and Cool NoReheat AirTerminal Outputs
Zone Air Terminal VAV Damper Position []
AirTerminal:SingleDuct:SeriesPIU:Reheat
Field: Name
Field: Availability Schedule Name
Field: Maximum Air Flow Rate
Field: Maximum Primary Air Flow Rate
Field: Minimum Primary Air Flow Fraction
Field: Supply Air Inlet Node Name
Field: Secondary Air Inlet Node Name
Field: Outlet Node Name
Field: Reheat Coil Air Inlet Node Name
Field: Zone Mixer Name
Field: Fan Name
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Hot Water or Steam Inlet Node Name
Field: Convergence Tolerance
Single Duct Series PIU Reheat AirTerminal Outputs
Zone Air Terminal Heating Rate [W]
Zone Air Terminal Heating Energy [J]
Zone Air Terminal Sensible Cooling Rate [W]
Zone Air Terminal Sensible Cooling Energy [J]
AirTerminal:SingleDuct:ParallelPIU:Reheat
Field: Name
Field: Availability Schedule Name
Field: Maximum Primary Air Flow Rate
Field: Maximum Secondary Air Flow Rate
Field: Minimum Primary Air Flow Fraction
Field: Fan On Flow Fraction
Field: Supply Air Inlet Node Name
Field: Secondary Air Inlet Node Name
Field: Outlet Node Name
Field: Reheat Coil Air Inlet Node Name
Field: Zone Mixer Name
Field: Fan Name
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Hot Water or Steam Inlet Node Name
Field: Convergence Tolerance
Single Duct Parallel PIU Reheat AirTerminal Outputs
Zone Air Terminal Heating Rate [W]
Zone Air Terminal Heating Energy [J]
Zone Air Terminal Sensible Cooling Rate [W]
Zone Air Terminal Sensible Cooling Energy [J]
AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction
Field: Name
Field: Availability Schedule Name
Field: Maximum Total Air Flow Rate
Field: Induction Ratio
Field: Supply Air Inlet Node Name
Field: Induced Air Inlet Node Name
Field: Air Outlet Node Name
Field: Hot Water Inlet Node Name
Field: Cold Water Inlet Node Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Maximum Hot Water Flow Rate
Field: Minimum Hot Water Flow Rate
Field: Heating Convergence Tolerance
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Maximum Cold Water Flow Rate
Field: Minimum Cold Water Flow Rate
Field: Cooling Convergence Tolerance
Field: Zone Mixer Name
Single Duct Constant Volume Four Pipe Induction AirTerminal Outputs
AirTerminal:SingleDuct:ConstantVolume:CooledBeam
Field: Name
Field: Availability Schedule Name
Field: Cooled Beam Type
Field: Supply Air Inlet Node Name
Field: Supply Air Outlet Node Name
Field: Chilled Water Inlet Node Name
Field: Chilled Water Outlet Node Name
Field: Supply Air Volumetric Flow Rate
Field: Maximum Total Chilled Water Volumetric Flow Rate
Field: Number of Beams
Field: Beam Length
Field: Design Inlet Water Temperature
Field: Design Outlet Water Temperature
Field: Coil Surface Area per Coil Length
Field: Model Parameter (a)
Field: Model Parameter n1
Field: Model Parameter n2
Field: Model Parameter n3
Field: Model Parameter 0 (a)
Field: Model Parameter K1 (K1)
Field: Model Parameter n
Field: Coefficient of Induction Kin (Kin)
Field: Pipe Inside Diameter
Singled Duct Constant Volume Cooled Beam AirTerminal Outputs
Zone Air Terminal Beam Sensible Cooling Rate [W]
Zone Air Terminal Beam Sensible Cooling Energy [J]
Zone Air Terminal Supply Air Sensible Cooling Rate [W]
Zone Air Terminal Supply Air Sensible Cooling Energy [J]
Zone Air Terminal Supply Air Sensible Heating Rate [W]
Zone Air Terminal Supply Air Sensible Heating Energy [J]
Zone Air Terminal Beam Chilled Water Energy [J]
AirTerminal:DualDuct:ConstantVolume
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Hot Air Inlet Node Name
Field: Cold Air Inlet Node Name
Field: Maximum Air Flow Rate
Dual Duct Constant Volume AirTerminal Outputs
Zone Air Terminal Cold Supply Duct Damper Position
Zone Air Terminal Hot Supply Duct Damper Position
AirTerminal:DualDuct:VAV
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Hot Air Inlet Node Name
Field: Cold Air Inlet Node Name
Field: Maximum Damper Air Flow Rate
Field: Zone Minimum Air Flow Fraction
Field: Design Specification Outdoor Air Object Name
Dual Duct VAV AirTerminal Outputs
Zone Air Terminal Cold Supply Duct Damper Position []
Zone Air Terminal Hot Supply Duct Damper Position []
Zone Air Terminal Outdoor Air Volume Flow Rate [m3/s]
AirTerminal:DualDuct:VAV:OutdoorAir
Field: Name
Field: Availability Schedule Name
Field: Air Outlet Node Name
Field: Outdoor Air Inlet Node Name
Field: Recirculated Air Inlet Node Name
Field: Maximum Zone Total Airflow Rate
Field: Design Specification Outdoor Air Object Name
Field: Per Person Ventilation Rate Mode
Dual Duct VAV Outdoor Air AirTerminal Outputs
Zone Air Terminal Outdoor Air Duct Damper Position []
Zone Air Terminal Recirculated Air Duct Damper Position []
Zone Air Terminal Outdoor Air Fraction []
Group – Zone Forced Air Units
ZoneHVAC:IdealLoadsAirSystem
Field: Name
Field: Availability Schedule Name
Field: Zone Supply Air Node Name
Field: Zone Exhaust Air Node Name
Field: Maximum Heating Supply Air Temperature
Field: Minimum Cooling Supply Air Temperature
Field: Maximum Heating Supply Air Humidity Ratio
Field: Minimum Cooling Supply Air Humidity Ratio
Field: Heating Limit
Field: Maximum Heating Air Flow Rate
Field: Maximum Sensible Heating Capacity
Field: Cooling Limit
Field: Maximum Cooling Air Flow Rate
Field: Maximum Total Cooling Capacity
Field: Heating Availability Schedule Name
Field: Cooling Availability Schedule Name
Field: Dehumidification Control Type
Field: Cooling Sensible Heat Ratio
Field: Humidification Control Type
Field: Design Specification Outdoor Air Object Name
Field: Outdoor Air Inlet Node Name
Field: Demand Controlled Ventilation Type
Field: Outdoor Air Economizer Type
Field: Heat Recovery Type
Field: Sensible Heat Recovery Effectiveness
Field: Latent Heat Recovery Effectiveness
ZoneHVAC:IdealLoadsAirSystem Outputs
Ideal Loads Output Variable Overview
Zone Ideal Loads Supply Air Sensible Heating Energy [J]
Zone Ideal Loads Supply Air Sensible Heating Rate [W]
Zone Ideal Loads Supply Air Latent Heating Energy [J]
Zone Ideal Loads Supply Air Latent Heating Rate [W]
Zone Ideal Loads Supply Air Total Heating Energy [J]
Zone Ideal Loads Supply Air Total Heating Rate [W]
Zone Ideal Loads Supply Air Sensible Cooling Energy [J]
Zone Ideal Loads Supply Air Sensible Cooling Rate [W]
Zone Ideal Loads Supply Air Latent Cooling Energy [J]
Zone Ideal Loads Supply Air Latent Cooling Rate [W]
Zone Ideal Loads Supply Air Total Cooling Energy [J]
Zone Ideal Loads Supply Air Total Cooling Rate [W]
Zone Ideal Loads Zone Sensible Heating Energy [J]
Zone Ideal Loads Zone Sensible Heating Rate [W]
Zone Ideal Loads Zone Latent Heating Energy [J]
Zone Ideal Loads Zone Latent Heating Rate [W]
Zone Ideal Loads Zone Total Heating Energy [J]
Zone Ideal Loads Zone Total Heating Rate [W]
Zone Ideal Loads Zone Sensible Cooling Energy [J]
Zone Ideal Loads Zone Sensible Cooling Rate [W]
Zone Ideal Loads Zone Latent Cooling Energy [J]
Zone Ideal Loads Zone Latent Cooling Rate [W]
Zone Ideal Loads Zone Total Cooling Energy [J]
Zone Ideal Loads Zone Total Cooling Rate [W]
Zone Ideal Loads Outdoor Air Sensible Heating Energy [J]
Zone Ideal Loads Outdoor Air Sensible Heating Rate [W]
Zone Ideal Loads Outdoor Air Latent Heating Energy [J]
Zone Ideal Loads Outdoor Air Latent Heating Rate [W]
Zone Ideal Loads Outdoor Air Total Heating Energy [J]
Zone Ideal Loads Outdoor Air Total Heating Rate [W]
Zone Ideal Loads Outdoor Air Sensible Cooling Energy [J]
Zone Ideal Loads Outdoor Air Sensible Cooling Rate [W]
Zone Ideal Loads Outdoor Air Latent Cooling Energy [J]
Zone Ideal Loads Outdoor Air Latent Cooling Rate [W]
Zone Ideal Loads Outdoor Air Total Cooling Energy [J]
Zone Ideal Loads Outdoor Air Total Cooling Rate [W]
Zone Ideal Loads Heat Recovery Sensible Heating Energy [J]
Zone Ideal Loads Heat Recovery Sensible Heating Rate [W]
Zone Ideal Loads Heat Recovery Latent Heating Energy [J]
Zone Ideal Loads Heat Recovery Latent Heating Rate [W]
Zone Ideal Loads Heat Recovery Total Heating Energy [J]
Zone Ideal Loads Heat Recovery Total Heating Rate [W]
Zone Ideal Loads Heat Recovery Sensible Cooling Energy [J]
Zone Ideal Loads Heat Recovery Sensible Cooling Rate [W]
Zone Ideal Loads Heat Recovery Latent Cooling Energy [J]
Zone Ideal Loads Heat Recovery Latent Cooling Rate [W]
Zone Ideal Loads Heat Recovery Total Cooling Energy [J]
Zone Ideal Loads Heat Recovery Total Cooling Rate [W]
Zone Ideal Loads Economizer Active Time [hr]
Zone Ideal Loads Heat Recovery Active Time [hr]
Zone Ideal Loads Hybrid Ventilation Available Status []
ZoneHVAC:FourPipeFanCoil
Field: Name
Field: Availability Schedule Name
Field: Maximum Supply Air Flow Rate
Field: Low Speed Supply Air Flow Ratio
Field: Medium Speed Supply Air Flow Ratio
Field: Maximum Outdoor Air Flow Rate
Field: Outdoor Air Schedule Name
The name of a schedule whose values (0.0 to 1.0) are used as multipliers to alter the outdoor air flow rate. If this field is left blank, the values will default to 1.0.
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Maximum Cold Water Flow Rate
Field: Minimum Cold Water Flow Rate
Field: Cooling Convergence Tolerance
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Maximum Hot Water Flow Rate
Field: Minimum Hot Water Flow Rate
Field: Heating Convergence Tolerance
Fan Coil Outputs
Fan Coil Heating Rate [W]
Fan Coil Heating Energy [J]
Fan Coil Total Cooling Rate [W]
Fan Coil Total Cooling Energy [J]
Fan Coil Sensible Cooling Rate [W]
Fan Coil Sensible Cooling Energy [J]
Fan Coil Fan Electric Power [W]
Fan Coil Fan Electric Energy [J]
Fan Coil Runtime Fraction[]
Fan Coil Fan Speed Level []
Fan Coil Part Load Ratio []
Fan Coil Availability Status []
ZoneHVAC:UnitVentilator
Field: Name
Field: Availability Schedule Name
Field: Maximum Supply Air Flow Rate
Field: Outdoor Air Control Type
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Schedule Name
Field: Maximum Outdoor Air Flow Rate
Field: Maximum Outdoor Air Fraction or Temperature Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Node Name
Field: Exhaust Air Node Name
Field: Mixed Air Node Name
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Coil Option
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Heating Convergence Tolerance
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Cooling Convergence Tolerance
Field: Availability Manager List Name
Unit Ventilator Outputs
Zone Unit Ventilator Heating Rate [W]
Zone Unit Ventilator Heating Energy [J]
Zone Unit Ventilator Total Cooling Rate [W]
Zone Unit Ventilator Total Cooling Energy [J]
Zone Unit Ventilator Sensible Cooling Rate [W]
Zone Unit Ventilator Sensible Cooling Energy [J]
Zone Unit Ventilator Fan Electric Power [W]
Zone Unit Ventilator Fan Electric Energy [J]
ZoneHVAC:UnitHeater
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Maximum Supply Air Flow Rate
Field: Fan Control Type
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Maximum Hot Water or Steam Flow Rate
Field: Minimum Hot Water or Steam Flow Rate
Field: Heating Convergence Tolerance
Field: Availability Manager List Name
Unit Heater Outputs
Zone Unit Heater Heating Rate [W]
Zone Unit Heater Heating Energy [J]
Zone Unit Heater Fan Electric Power [W]
Zone Unit Heater Fan Electric Energy [J]
ZoneHVAC:OutdoorAirUnit
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Outdoor Air Flow Rate
Field: Outdoor Air Schedule Name
Field: Supply Fan Name
Field: Fan Placement
Field: Exhaust Fan Name
Field: Exhaust Air Flow Rate
Field: Exhaust Air Schedule Name
Field: Unit Control Type
Field: High Air Control Temperature Schedule Name
Field: Low Air Control Temperature Schedule Name
Field: Outdoor Air Node Name
Field: Air Outlet Node Name
Field: Air Inlet Node Name
Field: Supply Fan Outlet Node Name
Field: Outdoor Air Unit List Name
Field: Availability Manager List Name
Outdoor Air Unit Outputs
Zone Outdoor Air Unit Total Heating Rate [W]
Zone Outdoor Air Unit Total Heating Energy [J]
Zone Outdoor Air Unit Total Cooling Rate [W]
Zone Outdoor Air Unit Total Cooling Energy [J]
Zone Outdoor Air Unit Sensible Cooling Energy [J]
Zone Outdoor Air Unit Sensible Cooling Rate [W]
Zone Outdoor Air Unit Sensible Heating Energy [J]
Zone Outdoor Air Unit Sensible Heating Rate [W]
Zone Outdoor Air Unit Latent Cooling Energy [J]
Zone Outdoor Air Unit Latent Cooling Rate [W]
Zone Outdoor Air Unit Latent Heating Energy [J]
Zone Outdoor Air Unit Latent Heating Rate [W]
Zone Outdoor Air Unit Fan Electric Power [W]
Zone Outdoor Air Unit Fan Electric Energy [J]
Zone Outdoor Air Unit Air Mass Flow Rate [kg/s]
Zone Outdoor Air Unit Fan Availability Status []
ZoneHVAC:OutdoorAirUnit:EquipmentList
Field: Name
Field Set (Component Object Type, Component Name, Control Node Name) up to 8
Field: Component Object Type
Field: Component Name
ZoneHVAC:WindowAirConditioner
Field: Name
Field: Availability Schedule Name
Field: Maximum Supply Air Flow Rate
Field: Maximum Outdoor Air Flow Rate
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Fan Object Type
Field:Supply Air Fan Name
Field: Cooling Coil Object Type
Field: DX Cooling Coil Name
Field: Supply Air Fan Operating Mode Schedule Name
Field: Fan Placement
Field: Cooling Convergence Tolerance
Field: Availability Manager List Name
Window Air Conditioner Outputs
Zone Window Air Conditioner Total Cooling Rate [W]
Zone Window Air Conditioner Total Cooling Energy [J]
Zone Window Air Conditioner Sensible Cooling Rate [W]
Zone Window Air Conditioner Sensible Cooling Energy [J]
Zone Window Air Conditioner Latent Cooling Rate [W]
Zone Window Air Conditioner Latent Cooling Energy [J]
Zone Window Air Conditioner Electric Power[W]
Zone Window Air Conditioner Electric Energy [J]
Zone Window Air Conditioner Fan Part Load Ratio []
Zone Window Air Conditioner Compressor Part Load Ratio []
ZoneHVAC:PackagedTerminalAirConditioner
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Outdoor Air Flow Rate During Cooling Operation
Field: Outdoor Air Flow Rate During Heating Operation
Field: Outdoor Air Flow Rate When No Cooling or Heating is Needed
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Availability Manager List Name
Packaged Terminal Air Conditioner (PTAC) Outputs
Zone Packaged Terminal Air Conditioner Total Heating Rate [W]
Zone Packaged Terminal Air Conditioner Total Heating Energy [J]
Zone Packaged Terminal Air Conditioner Total Cooling Rate [W]
Zone Packaged Terminal Air Conditioner Total Cooling Energy [J]
Zone Packaged Terminal Air Conditioner Sensible Heating Rate [W]
Zone Packaged Terminal Air Conditioner Sensible Heating Energy [J]
Zone Packaged Terminal Air Conditioner Sensible Cooling Rate [W]
Zone Packaged Terminal Air Conditioner Sensible Cooling Energy [J]
Zone Packaged Terminal Air Conditioner Latent Heating Rate [W]
Zone Packaged Terminal Air Conditioner Latent Heating Energy [J]
Zone Packaged Terminal Air Conditioner Latent Cooling Rate [W]
Zone Packaged Terminal Air Conditioner Latent Cooling Energy [J]
Zone Packaged Terminal Air Conditioner Electric Power [W]
Zone Packaged Terminal Air Conditioner Electric Energy [J]
Zone Packaged Terminal Air Conditioner Fan Part Load Ratio []
Zone Packaged Terminal Air Conditioner Compressor Part Load Ratio []
Zone Packaged Terminal Air Conditioner Fan Availability Status []
ZoneHVAC:PackagedTerminalHeatPump
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Outdoor Air Flow Rate During Cooling Operation
Field: Outdoor Air Flow Rate During Heating Operation
Field: Outdoor Air Flow Rate When No Cooling or Heating is Needed
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Heating Convergence Tolerance
Field: Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Cooling Convergence Tolerance
Field: Supplemental Heating Coil Object Type
Field: Supplemental Heating Coil Name
Field: Maximum Supply Air Temperature from Supplemental Heater
Field: Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
Field: Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Availability Manager List Name
Packaged Terminal Heat Pump (PTHP) Outputs
Zone Packaged Terminal Heat Pump Total Heating Rate [W]
Zone Packaged Terminal Heat Pump Total Heating Energy [J]
Zone Packaged Terminal Heat Pump Total Cooling Rate [W]
Zone Packaged Terminal Heat Pump Total Cooling Energy [J]
Zone Packaged Terminal Heat Pump Sensible Heating Rate [W]
Zone Packaged Terminal Heat Pump Sensible Heating Energy [J]
Zone Packaged Terminal Heat Pump Sensible Cooling Rate [W]
Zone Packaged Terminal Heat Pump Sensible Cooling Energy [J]
Zone Packaged Terminal Heat Pump Latent Heating Rate [W]
Zone Packaged Terminal Heat Pump Latent Heating Energy [J]
Zone Packaged Terminal Heat Pump Latent Cooling Rate [W]
Zone Packaged Terminal Heat Pump Latent Cooling Energy [J]
Zone Packaged Terminal Heat Pump Electric Power [W]
Zone Packaged Terminal Heat Pump Electric Energy [J]
Zone Packaged Terminal Heat Pump Fan Part Load Ratio []
Zone Packaged Terminal Heat Pump Compressor Part Load Ratio []
Zone Packaged Terminal Heat Pump Fan Availability Status []
ZoneHVAC:RefrigerationChillerSet
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Air Chiller #1 Name
Field: Air Chiller #2 Name
Field: Air Chiller #3 Name
Field: Air Chiller #n Name (Extensible list, 20 provided in the IDD)
ZoneHVAC:WaterToAirHeatPump
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Outdoor Air Flow Rate During Cooling Operation
Field: Outdoor Air Flow Rate During Heating Operation
Field: Outdoor Air Flow Rate When No Cooling or Heating is Needed
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Maximum Cycling Rate
Field: Heat Pump Time Constant
Field: Fraction of On-Cycle Power Use
Field: Heat Pump Fan Delay Time
Field: Supplemental Heating Coil Object Type
Field: Supplemental Heating Coil Name
Field: Maximum Supply Air Temperature from Supplemental Heater
Field: Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
Field: Outdoor Dry-Bulb Temperature Sensor Node Name
Field: Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Availability Manager List Name
Field: Heat Pump Coil Water Flow Mode
Water to Air Heat Pump (ZoneHVAC) Outputs
Zone Water to Air Heat Pump Total Heating Rate [W]
Zone Water to Air Heat Pump Total Heating Energy [J]
Zone Water to Air Heat Pump Total Cooling Rate [W]
Zone Water to Air Heat Pump Total Cooling Energy [J]
Zone Water to Air Heat Pump Sensible Heating Rate [W]
Zone Water to Air Heat Pump Sensible Heating Energy [J]
Zone Water to Air Heat Pump Sensible Cooling Rate [W]
Zone Water to Air Heat Pump Sensible Cooling Energy [J]
Zone Water to Air Heat Pump Latent Heating Rate [W]
Zone Water to Air Heat Pump Latent Heating Energy [J]
Zone Water to Air Heat Pump Latent Cooling Rate [W]
Zone Water to Air Heat Pump Latent Cooling Energy [J]
Zone Water to Air Heat Pump Electric Power [W]
Zone Water to Air Heat Pump Electric Energy [J]
Zone Water to Air Heat Pump Fan Part Load Ratio []
Zone Water to Air Heat Pump Compressor Part Load Ratio []
Zone Water to Air Heat Pump Fan Availability Status []
ZoneHVAC:Dehumidifier:DX
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Rated Water Removal
Field: Rated Energy Factor
Field: Rated Air Flow Rate
Field: Water Removal Curve Name
Field: Energy Factor Curve Name
Field: Part Load Fraction Correlation Curve Name
Field: Minimum Dry-Bulb Temperature for Dehumidifier Operation
Field: Maximum Dry-Bulb Temperature for Dehumidifier Operation
Field: Off-Cycle Parasitic Electric Load
Field: Condensate Collection Water Storage Tank Name
DX Dehumidifier (ZoneHVAC) Outputs
Zone Dehumidifier Sensible Heating Rate [W]
Zone Dehumidifier Sensible Heating Energy [J]
Zone Dehumidifier Removed Water Mass Flow Rate [kg/s]
Zone Dehumidifier Removed Water Mass [kg]
Zone Dehumidifier Electric Power [W]
Zone Dehumidifier Electric Energy [J]
Zone Dehumidifier Off Cycle Parasitic Electric Power [W]
Zone Dehumidifier Off Cycle Parasitic Electric Energy [J]
Zone Dehumidifier Part Load Ratio []
Zone Dehumidifier Runtime Fraction []
Zone Dehumidifier Outlet Air Temperature [C]
Zone Dehumidifier Condensate Volume Flow Rate [m3/s]
Zone Dehumidifier Condensate Volume [m3]
ZoneHVAC:EnergyRecoveryVentilator
Field: Name
Field: Availability Schedule Name
Field: Heat Exchanger Name
Field: Supply Air Flow Rate
Field: Exhaust Air Flow Rate
Field: Supply Air Fan Name
Field: Exhaust Air Fan Name
Field: Controller Name
Field: Ventilation Rate per Unit Floor Area
Field: Ventilation Rate per Occupant
Field: Availability Manager List Name
Energy Recovery Ventilator (ERV) (ZoneHVAC) Outputs
Zone Ventilator Electric Power [W]
Zone Ventilator Electric Energy [J]
Zone Ventilator Total Cooling Rate [W]
Zone Ventilator Total Cooling Energy [J]
Zone Ventilator Total Heating Rate [W]
Zone Ventilator Total Heating Energy [J]
Zone Ventilator Sensible Cooling Rate [W]
Zone Ventilator Sensible Cooling Energy [J]
Zone Ventilator Sensible Heating Rate [W]
Zone Ventilator Sensible Heating Energy [J]
Zone Ventilator Latent Cooling Rate [W]
Zone Ventilator Latent Cooling Energy [J]
Zone Ventilator Latent Heating Rate [W]
Zone Ventilator Latent Heating Energy [J]
Zone Ventilator Supply Fan Availability Status []
ZoneHVAC:TerminalUnit:VariableRefrigerantFlow
Field: Zone Terminal Unit Name
Field: Availability Schedule Name
Field: Terminal Unit Air Inlet Node Name
Field: Terminal Unit Air Outlet Node Name
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate When No Cooling is Needed
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Heating is Needed
Field: Outdoor Air Flow Rate During Cooling Operation
Field: Outdoor Air Flow Rate During Heating Operation
Field: Outdoor Air Flow Rate When No Cooling or Heating is Needed
Field: Supply Air Fan Operating Mode Schedule Name
Field: Supply Air Fan Placement
Field: Supply Air Fan Object Type
Field: Supply Air Fan Object Name
Field: Outside Air Mixer Object Type
Field: Outside Air Mixer Object Name
Field: DX Cooling Coil Object Type
Field: DX Cooling Coil Name
Field: DX Heating Coil Object Type
Field: DX Heating Coil Object Name
Field: Zone Terminal Unit On Parasitic Electric Energy Use
Field: Zone Terminal Unit Off Parasitic Electric Energy Use
Field: Rated Total Heating Capacity Sizing Ratio
Field: Availability Manager List Name
Variable Refrigerant Flow (VRF) Terminal Unit (ZoneHVAC) Outputs
Zone VRF Air Terminal Total Cooling Rate [W]
Zone VRF Air Terminal Total Cooling Energy [J]
Zone VRF Air Terminal Sensible Cooling Rate [W]
Zone VRF Air Terminal Sensible Cooling Energy [J]
Zone VRF Air Terminal Latent Cooling Rate [W]
Zone VRF Air Terminal Latent Cooling Energy [J]
Zone VRF Air Terminal Total Heating Rate [W]
Zone VRF Air Terminal Total Heating Energy [J]
Zone VRF Air Terminal Sensible Heating Rate [W]
Zone VRF Air Terminal Sensible Heating Energy [J]
Zone VRF Air Terminal Latent Heating Rate [W]
Zone VRF Air Terminal Latent Heating Energy [J]
Zone VRF Air Terminal Cooling Electric Power[W]
Zone VRF Air Terminal Cooling Electric Energy [J]
Zone VRF Air Terminal Heating Electric Power[W]
Zone VRF Air Terminal Heating Electric Energy [J]
Zone VRF Air Terminal Fan Availability Status []
Group – Unitary Equipment
Furnace and Unitary Systems
AirLoopHVAC:Unitary:Furnace:HeatCool
Field: Name
Field: Availability Schedule Name
Field: Furnace Air Inlet Node Name
Field: Furnace Air Outlet Node Name
Field: Maximum Supply Air Temperature
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Controlling Zone or Thermostat Location
Field: Supply Fan Object Type
Field: Supply Fan Name
Field: Fan Placement
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Dehumidification Control Type
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Unitary System/Furnace Heat and Cool (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio
AirLoopHVAC:UnitaryHeatCool
Field: Name
Field: Availability Schedule Name
Field: Unitary System Air Inlet Node Name
Field: Unitary System Air Outlet Node Name
Field: Maximum Supply Air Temperature
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Controlling Zone or Thermostat Location
Field: Supply Fan Object Type
Field: Supply Fan Name
Field: Fan Placement
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Dehumidification Control Type
Field: Reheat Coil Object Type
Field: Reheat Coil Name
Unitary System Heat and Cool (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio []
Unitary System Compressor Part Load Ratio []
AirLoopHVAC:UnitaryHeatPump:AirToAir
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Supply Air Flow Rate During Cooling Operation
Field: Supply Air Flow Rate During Heating Operation
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Controlling Zone or Thermostat Location
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Supplemental Heating Coil Object Type
Field: Supplemental Heating Coil Name
Field: Maximum Supply Air Temperature from Supplemental Heater
Field: Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
Field: Fan Placement
Field: Dehumidification Control Type
AirLoopHVAC:UnitaryHeatPump:AirToAir Example Specification
Unitary Air to Air Heat Pump (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio []
Unitary System Compressor Part Load Ratio []
Unitary System Dehumidification Induced Heating Demand Rate [W]
AirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Controlling Zone or Thermostat Location
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Supply Air Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Supplemental Heating Coil Object Type
Field: Supplemental Heating Coil Name
Field: Maximum Supply Air Temperature from Supplemental Heater
Field: Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
Field: Auxiliary On-Cycle Electric Power
Field: Auxiliary Off-Cycle Electric Power
Field: Design Heat Recovery Water Flow Rate
Field: Maximum Temperature for Heat Recovery
Field: Heat Recovery Water Inlet Node Name
Field: Heat Recovery Water Outlet Node Name
Field: Supply Air Flow Rate When No Cooling or Heating is Needed
Field: Number of Speeds for Heating
Field: Number of Speeds for Cooling
Field: Speed 1 Supply Air Flow Rate During Heating Operation
Field: Speed 2 Supply Air Flow Rate During Heating Operation
Field: Speed 3 Supply Air Flow Rate During Heating Operation
Field: Speed 4 Supply Air Flow Rate During Heating Operation
Field: Speed 1 Supply Air Flow Rate During Cooling Operation
Field: Speed 2 Supply Air Flow Rate During Cooling Operation
Field: Speed 3 Supply Air Flow Rate During Cooling Operation
Field: Speed 4 Supply Air Flow Rate During Cooling Operation
Unitary Air to Air MultiSpeed Heat Pump (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio []
Unitary System Compressor Part Load Ratio []
Unitary System DX Coil Cycling Ratio []
Unitary System DX Coil Speed Ratio []
Unitary System DX Coil Speed Level []
Unitary System Total Heating Rate [W]
Unitary System Total Cooling Rate [W]
Unitary System Sensible Heating Rate [W]
Unitary System Sensible Cooling Rate [W]
Unitary System Latent Heating Rate [W]
Unitary System Latent Cooling Rate [W]
Unitary System Electric Power [W]
Unitary System Electric Energy [J]
Unitary System Ancillary Electric Power [W]
Unitary System Cooling Ancillary Electric Energy [J]
Unitary System Heating Ancillary Electric Energy [J]
Unitary System Heat Recovery Inlet Temperature [C]
Unitary System Heat Recovery Outlet Temperature [C]
Unitary System Heat Recovery Fluid Mass Flow Rate [kg/s]
Unitary System Heat Recovery Rate [W]
Unitary System Heat Recovery Energy [J]
AirLoopHVAC:Unitary:Furnace:HeatOnly
Field: Name
Field: Availability Schedule Name
Field: Furnace Inlet Node Name
Field: Furnace Outlet Node Name
Field: Maximum Supply Air Temperature
Field: Supply Air Flow Rate
Field: Controlling Zone or Thermostat Location
Field: Supply Fan Object Type
Field: Supply Fan Name
Field: Fan Placement
Field: Heating Coil Object Type
Field: Heating Coil Name
Unitary/Furnace Heat Only (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio []
AirLoopHVAC:UnitaryHeatOnly
Field: Name
Field: Availability Schedule Name
Field: Unitary System Air Inlet Node Name
Field: Unitary System Air Outlet Node Name
Field: Maximum Supply Air Temperature
Field: Supply Air Flow Rate
Field: Controlling Zone or Thermostat Location
Field: Supply Fan Object Type
Field: Supply Fan Name
Field: Fan Placement
Field: Heating Coil Object Type
Field: Heating Coil Name
Unitary Heat Only (AirLoopHVAC) Outputs
Unitary System Fan Part Load Ratio []
AirLoopHVAC:UnitaryHeatPump:WaterToAir
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Supply Air Flow Rate
Field: Controlling Zone or Thermostat Location
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Heating Convergence
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Cooling Convergence
Field: Maximum Cycling Rate
Field: Heat Pump Time Constant
Field: Fraction of On-Cycle Power Use
Field: Heat Pump Fan Delay Time
Field: Supplemental Heating Coil Object Type
Field: Supplemental Heating Coil Name
Field: Maximum Supply Air Temperature from Supplemental Heater
Field: Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
Field: Outdoor Dry-Bulb Temperature Sensor Node Name
Field: Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Dehumidification Control Type
Field: Heat Pump Coil Water Flow Mode
Unitary Water to Air Heat Pump (AirLoopHVAC) Outputs
Unitary System Requested Sensible Cooling Rate [W]
Unitary System Requested Latent Cooling Rate [W]
Unitary System Requested Heating Rate [W]
Unitary System Compressor Part Load Ratio []
Unitary System Fan Part Load Ratio []
Unitary System Dehumidification Induced Heating Demand Rate [W]
AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass
Field: Name
Field: Availability Schedule Name
Field: System Air Flow Rate During Cooling Operation
Field: System Air Flow Rate During Heating Operation
Field: System Air Flow Rate When No Cooling or Heating is Needed
Field: Outdoor Air Flow Rate During Cooling Operation
Field: Outdoor Air Flow Rate During Heating Operation
Field: Outdoor Air Flow Rate When No Cooling or Heating is Needed
Field: Outdoor Air Flow Rate Multiplier Schedule Name
Field: Air Inlet Node Name
Field: Bypass Duct Mixer Node Name
Field: Bypass Duct Splitter Node Name
Field: Air Outlet Node Name
Field: Outdoor Air Mixer Object Type
Field: Outdoor Air Mixer Name
Field: Supply Air Fan Object Type
Field: Supply Air Fan Name
Field: Supply Air Fan Placement
Field: Supply Air Fan Operating Mode Schedule Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Priority Control Mode
Field: Minimum Outlet Air Temperature During Cooling Operation
Field: Maximum Outlet Air Temperature During Heating Operation
Field: Dehumidification Control Type
Unitary VAV Changeover Bypass Heat and Cool (AirLoopHVAC) Outputs
Unitary System Total Heating Rate [W]
Unitary System Total Heating Energy [J]
Unitary System Total Cooling Rate [W]
Unitary System Total Cooling Energy [J]
Unitary System Sensible Heating Rate [W]
Unitary System Sensible Heating Energy [J]
Unitary System Sensible Cooling Rate [W]
Unitary System Sensible Cooling Energy [J]
Unitary System Latent Heating Rate [W]
Unitary System Latent Heating Energy [J]
Unitary System Latent Cooling Rate [W]
Unitary System Latent Cooling Energy [J]
Un itary System Electric Power [W]“unitary-system-electric-energy-j-1
Unitary System Fan Part Load Ratio []
Unitary System Compressor Part Load Ratio []
Unitary System Bypass Air Mass Flow Rate [kg/s]
Unitary System Air Outlet Setpoint Temperature [C]
Group – Variable Refrigerant Flow Equipment
AirConditioner:VariableRefrigerantFlow
Field: Heat Pump Name
Field: Availability Schedule Name
Field: Rated Total Cooling Capacity
Field: Rated Cooling COP
Field: Minimum Outdoor Temperature in Cooling Mode
Field: Maximum Outdoor Temperature in Cooling Mode
Field: Cooling Capacity Ratio Modifier Function of Low Temperature Curve Name
Field: Cooling Capacity Ratio Boundary Curve Name
Field: Cooling Capacity Ratio Modifier Function of High Temperature Curve Name
Field: Cooling Energy Input Ratio Modifier Function of Low Temperature Curve Name
Field: Cooling Energy Input Ratio Boundary Name
Field: Cooling Energy Input Ratio Modifier Function of High Temperature Curve Name
Field: Cooling Energy Input Ratio Modifier Function of Low Part-Load Ratio Curve Name
Field: Cooling Energy Input Ratio Modifier Function of HIgh Part-Load Ratio Curve Name
Field: Cooling Combination Ratio Correction Factor Curve Name
Field: Cooling Part-Load Fraction Correlation Curve Name
Field: Rated Total Heating Capacity
Field: Rated Total Heating Capacity Sizing Ratio
Field: Rated Heating COP
Field: Minimum Outdoor Temperature in Heating Mode
Field: Maximum Outdoor Temperature in Heating Mode
Field: Heating Capacity Ratio Modifier Function of Low Temperature Curve Name
Field: Heating Capacity Ratio Boundary Curve Name
Field: Heating Capacity Ratio Modifier Function of High Temperature Curve Name
Field: Heating Energy Input Ratio Modifier Function of Low Temperature Curve Name
Field: Heating Energy Input Ratio Boundary Curve Name
Field: Heating Energy Input Ratio Modifier Function of High Temperature Curve Name
Field: Heating Performance Curve Outdoor Temperature Type
Field: Heating Energy Input Ratio Modifier Function of Low Part-Load Ratio Curve Name
Field: Heating Energy Input Ratio Modifier Function of High Part-Load Ratio Curve Name
Field: Heating Combination Ratio Correction Factor Curve Name
Field: Heating Part-Load Fraction Correlation Curve Name
Field: Minimum Heat Pump Part-Load Ratio
Field: Zone Name for Master Thermostat Location
Field: Master Thermostat Priority Control Type
Field: Thermostat Priority Schedule Name
Field: Zone Terminal Unit List Name
Field: Heat Pump Waste Heat Recovery
Field: Equivalent Piping Length used for Piping Correction Factor in Cooling Mode
Field: Vertical Height used for Piping Correction Factor
Field: Piping Correction Factor for Length in Cooling Mode Curve Name
Field: Piping Correction Factor for Height in Cooling Mode Coefficient
Field: Equivalent Piping Length used for Piping Correction Factor in Heating Mode
Field: Piping Correction Factor for Length in Heating Mode Curve Name
Field: Piping Correction Factor for Height in Heating Mode Coefficient
Field: Crankcase Heater Power per Compressor
Field: Number of Compressors
Field: Ratio of Compressor Size to Total Compressor Capacity
Field: Maximum Outdoor Dry-bulb Temperature for Crankcase Heater
Field: Defrost Strategy
Field: Defrost Control
Field: Defrost Energy Input Ratio Modifier Function of Temperature Curve Name
Field: Defrost Time Period Fraction
Field: Resistive Defrost Heater Capacity
Field: Maximum Outdoor Dry-bulb Temperature for Defrost Operation
Field: Condenser Type
Field: Condenser Inlet Node Name
Field: Condenser Outlet Node Name
Field: Water Condenser Volume Flow Rate
Field: Evaporative Condenser Effectiveness
Field: Evaporative Condenser Air Flow Rate
Field: Evaporative Condenser Pump Rated Power Consumption
Field: Supply Water Storage Tank Name
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Fuel Type
Field: Minimum Outdoor Temperature in Heat Recovery Mode
Field: Maximum Outdoor Temperature in Heat Recovery Mode
Field: Heat Recovery Cooling Capacity Modifier Curve Name
Field: Initial Heat Recovery Cooling Capacity Fraction
Field: Heat Recovery Cooling Capacity Time Constant
Field: Heat Recovery Cooling Energy Modifier Curve Name
Field: Initial Heat Recovery Cooling Energy Fraction
Field: Heat Recovery Cooling Energy Time Constant
Field: Heat Recovery Heating Capacity Modifier Curve Name
Field: Initial Heat Recovery Heating Capacity Fraction
Field: Heat Recovery Heating Capacity Time Constant
Field: Heat Recovery Heating Energy Modifier Curve Name
Field: Initial Heat Recovery Heating Energy Fraction
Field: Heat Recovery Heating Energy Time Constant
Variable Refrigerant Flow (VRF) Air Conditioner Outputs
VRF Heat Pump Total Cooling Rate [W]
VRF Heat Pump Total Heating Rate [W]
VRF Heat Pump Cooling Electric Power [W]
VRF Heat Pump Cooling Electric Energy [J]
VRF Heat Pump Heating Electric Power [W]
VRF Heat Pump Heating Electric Energy [J]
VRF Heat Pump Cooling COP[]
VRF Heat Pump Heating COP[]
VRF Heat Pump COP[]
VRF Heat Pump Defrost Electric Power [W]
VRF Heat Pump Defrost Electric Energy [J]
VRF Heat Pump Part Load Ratio
VRF Heat Pump Runtime Fraction []
VRF Heat Pump Cycling Ratio []
VRF Heat Pump Operating Mode []
VRF Heat Pump Condenser Inlet Temperature [C]
VRF Heat Pump Condenser Outlet Temperature [C]
VRF Heat Pump Condenser Mass Flow Rate [kg/s]
VRF Heat Pump Condenser Heat Transfer Rate [W]
VRF Heat Pump Condenser Heat Transfer Energy [J]
VRF Heat Pump Maximum Capacity Cooling Rate [W]
VRF Heat Pump Maximum Capacity Heating Rate [W]
VRF Heat Pump Terminal Unit Cooling Load Rate [W]
VRF Heat Pump Terminal Unit Heating Load Rate [W]
VRF Heat Pump Crankcase Heater Electric Power [W]
VRF Heat Pump Crankcase Heater Electric Energy [J]
VRF Heat Pump Evaporative Condenser Water Use Volume [m3]
VRF Heat Pump Evaporative Condenser Pump Electric Power [W]
VRF Heat Pump Evaporative Condenser Pump Electric Energy [J]
VRF Heat Pump Basin He ater Electric Power [W]“vrf-heat-pump-basin-heater-electric-energy-j
VRF Heat Pump Heat Recovery Status Change Multiplier []
ZoneTerminalUnitList
Field: Zone Terminal List Name
Field: Zone Terminal Unit Name
Group – Radiative / Convective Units
ZoneHVAC:Baseboard:RadiantConvective:Water
Field: Name
Field: Availability Schedule Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Rated Average Water Temperature
Field: Rated Water Mass Flow Rate
This field is the rated standard water flow rate in kg/s which is published as part of the manufacturer’s literature. It is used by the manufacturers when determining the rated capacity (see next field). The default value is 0.063kg/s. If it is blank or zero, the default values is assumed.
Field: Rated Capacity
This field is the rated water baseboard capacity in watts at a rated water mass flow rate (see previous field). Almost all publications from manufacturers indicate it as W/m (Btuh per linear foot). The user thus must multiply it by the active length of the unit. The active length is available in the literature. Manufacturers are required to publish the difference between active and total length of the unit (I=B=R rating for boilers baseboard radiation, 2009). This field can be autosized by EnergyPlus. If it is blank or zero, autosizing is assumed.
Field: Maximum Water Flow Rate
Field: Convergence Tolerance
Field: Fraction Radiant
This field specifies what fraction of the power input to the baseboard heater is actually transferred to the space as radiant heat. The fraction should be between 0 and 1. This is the portion of the total power that is modeled as radiation. The portion that is radiant heat transfer from the baseboard heater is distributed to people and specific surfaces using the remaining fields. Note that the sum of the fractions in the remaining fields (people and surfaces) must equal 1.0 so that all the radiant power is distributed properly. For more information on the specification of this parameter, please see the Engineering Reference for EnergyPlus.
Field: Fraction of Radiant Energy Incident on People
Field Set: Surface Name, Fraction of Radiant Energy to Surface
The following two items are repeated up to a maximum of 20 surface/fraction pairs. At least one surface/fraction pair must appear in an input file. In other words, at least one surface must be identified as a recipient of radiant energy from the baseboard heater.
Field: Surface Name
Field: Fraction of Radiant Energy to Surface
Baseboard (Water) Radiant Convective (ZoneHVAC) Outputs
Baseboard Total Heating Rate [W]
Baseboard Convective Heating Rate [W]
Baseboard Radiant Heating Rate [W]
Baseboard Total Heating Energy [J]
Baseboard Convective Heating Energy [J]
Baseboard Radiant Heating Energy [J]
Baseboard Hot Water Mass Flow Rate [kg/s]
Baseboard Air Mass Flow Rate [kg/s]
Baseboard Water Inlet Temperature [C]
Baseboard Water Outlet Temperature [C]
Baseboard Air Inlet Temperature [C]
Baseboard Air Outlet Temperature [C]
ZoneHVAC:Baseboard:RadiantConvective:Steam
Field: Name
Field: Availability Schedule Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Degree of SubCooling
Field: Maximum Steam Flow Rate
Field: Convergence Tolerance
Field: Fraction Radiant
Field: Fraction of Radiant Energy Incident on People
Field Set: Surface Name, Fraction of Radiant Energy to Surface
Field: Surface Name
Field: Fraction of Radiant Energy to Surface
Note on Fraction of Radiant Energy Incident on People and to Surfaces
Baseboard (Steam) Radiant Convective (ZoneHVAC) Outputs
Baseboard Total Heating Rate [W]
Baseboard Convective Heating Rate [W]
Baseboard Radiant Heating Rate [W]
Baseboard Total Heating Energy [J]
Baseboard Convective Heating Energy [J]
Baseboard Radiant Heating Energy [J]
Baseboard Steam Energy [J]
Baseboard Steam Rate [W]
Baseboard Steam Mass Flow Rate [kg/s]
Baseboard Steam Inlet Temperature [C]
Baseboard Steam Outlet Temperature [C]
ZoneHVAC:Baseboard:RadiantConvective:Electric
Field: Name
Field: Availability Schedule Name
Field: Nominal Capacity
Field: Efficiency
Field: Fraction Radiant
Field: Fraction of Radiant Energy Incident on People
Field Set: Surface Name, Fraction of Radiant Energy to Surface
Field Set: Surface Name
Field Set: Fraction of Radiant Energy to Surface
Note on Fraction of Radiant Energy Incident on People and to Surfaces
Baseboard (Electric) Radiant Convective (ZoneHVAC) Outputs
Baseboard Total Heating Rate [W]
Baseboard Radiant Heating Rate [W]
Baseboard Convective Heating Rate [W]
Baseboard Electric Energy [J]
Baseboard Electric Power [J]
Baseboard Total Heating Energy [J]
Baseboard Radiant Heating Energy [J]
Baseboard Convective Heating Energy [J]
ZoneHVAC:Baseboard:Convective:Water
Field: Name
Field: Availability Schedule Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: U-Factor Times Area Value
Field: Maximum Water Flow Rate
Field Convergence Tolerance
Baseboard (Water) Convective (ZoneHVAC) Outputs
Baseboard Total Heating Rate [W]
Baseboard Total Heating Energy [J]
Baseboard Hot Water Energy [J]
Baseboard Hot Water Mass Flow Rate [kg/s]
Baseboard Air Mass Flow Rate [kg/s]
Baseboard Water Inlet Temperature [C]
Baseboard Water Outlet Temperature [C]
Baseboard Air Inlet Temperature [C]
Baseboard Air Outlet Temperature [C]
ZoneHVAC:Baseboard:Convective:Electric
Field: Name
Field: Availability Schedule Name
Field: Nominal Capacity
Field: Efficiency
Baseboard (Electric) Convective (ZoneHVAC) Outputs
Baseboard Total Heating Rate [W]
Baseboard Total Heating Energy [J]
Baseboard Electric Energy [J]
Baseboard Electric Power [W]
ZoneHVAC:LowTemperatureRadiant:VariableFlow
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Surface Name or Radiant Surface Group Name
Field: Hydronic Tubing Inside Diameter
Field: Hydronic Tubing Length
Field: Temperature Control Type
Field: Maximum Hot Water Flow
Field: Heating Water Inlet Node Name
Field: Heating Water Outlet Node Name
Field: Heating Control Throttling Range
Field: Heating Control Temperature Schedule Name
Field: Maximum Cold Water Flow
Field: Cooling Water Inlet Node Name
Field: Cooling Water Outlet Node Name
Field: Cooling Control Throttling Range
Field: Cooling Control Temperature Schedule Name
Field: Condensation Control Type
Field: Condensation Control Dewpoint Offset
Field: Number of Circuits
Field: Circuit Length
Low Temperature Radiant Variable Flow (ZoneHVAC) Outputs
Zone Radiant HVAC Heating Rate [W]
Zone Radiant HVAC Heating Energy [J]
Zone Radiant HVAC Cooling Rate [W]
Zone Radiant HVAC Cooling Energy [J]
Zone Radiant HVAC Mass Flow Rate Rate [kg/s]
Zone Radiant HVAC Inlet Temperature [C]
Zone Radiant HVAC Outlet Temperature [C]
Zone Radiant HVAC Moisture Condensation Time[s]
Zone Radiant HVAC Heating Fluid Energy [J]
Zone Radiant HVAC Cooling Fluid Energy [J]
ZoneHVAC:LowTemperatureRadiant:ConstantFlow
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Surface Name or Radiant Surface Group Name
Field: Hydronic Tubing Inside Diameter
Field: Hydronic Tubing Length
Field: Temperature Control Type
Field: Rated Flow Rate
Field: Pump Flow Rate Schedule Name
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Heating Water Inlet Node Name
Field: Heating Water Outlet Node Name
Field: Heating High Water Temperature Schedule Name
Field: Heating Low Water Temperature Schedule Name
Field: Heating High Control Temperature Schedule Name
Field: Heating Low Control Temperature Schedule Name
Field: Cooling Water Inlet Node Name
Field: Cooling Water Outlet Node Name
Field: Cooling High Water Temperature Schedule Name
Field: Cooling Low Water Temperature Schedule Name
Field: Cooling High Control Temperature Schedule Name
Field: Cooling Low Control Temperature Schedule Name
Field: Condensation Control Type
Field: Condensation Control Dewpoint Offset
Field: Number of Circuits
Field: Circuit Length
Low Temperature Radiant Constant Flow (ZoneHVAC) Outputs
Zone Radiant HVAC Heating Rate [W]
Zone Radiant HVAC Heating Energy [J]
Zone Radiant HVAC Cooling Rate [W]
Zone Radiant HVAC Cooling Energy [J]
Zone Radiant HVAC Mass Flow Rate [kg/s]
Zone Radiant HVAC Injection Mass Flow Rate [kg/s]
Zone Radiant HVAC Recirculation Mass Flow Rate [kg/s]
Zone Radiant HVAC Inlet Temperature [C]
Zone Radiant HVAC Outlet Temperature [C]
Zone Radiant HVAC Pump Inlet Temperature [C]
Zone Radiant HVAC Pump Electric Power [W]
Zone Radiant HVAC Pump Electric Energy [J]
Zone Radiant HVAC Pump Mass Flow Rate [kg/s]
Zone Radiant HVAC Pump Fluid Heat Gain Rate [W]
Zone Radiant HVAC Pump Fluid Heat Gain Energy [J]
Zone Radiant HVAC Moisture Condensation Time [s]
Zone Radiant HVAC Cooling Fluid Heat Transfer Energy [J]
Zone Radiant HVAC Heating Fluid Heat Transfer Energy [J]
ZoneHVAC:LowTemperatureRadiant:Electric
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Surface Name or Radiant Surface Group Name
Field: Maximum Electrical Power to Panel
Field: Temperature Control Type
Field: Heating Throttling Range
Field: Heating Setpoint Temperature Schedule Name
Low Temperature Radiant Electric (ZoneHVAC) Outputs
Zone Radiant HVAC Electric Power [W]
Zone Radiant HVAC Electric Energy [J]
Zone Radiant HVAC Heating Energy [J]
Zone Radiant HVAC Heating Rate [W]
ZoneHVAC:LowTemperatureRadiant:SurfaceGroup
Field: Name
Field Set: Surface Name, Flow Fraction to Surface
Field: Surface Name
Field: Flow Fraction for Surface
ZoneHVAC:HighTemperatureRadiant
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Maximum Power Input
Field: Fuel Type
Field: Combustion Efficiency
Field: Fraction of Input Converted to Radiant Energy
Field: Fraction of Input Converted to Latent Energy
Field: Fraction of Input that Is Lost
Field: Temperature control type
Field: Heating Throttling Range
Field: Heating Setpoint Temperature Schedule Name
Field: Fraction of Radiant Energy Incident on People
Field Set: Surface Name, Fraction of radiant energy to Surface
Field: Surface Name
Field: Fraction of Radiant Energy to Surface
High Temperature Radiant (ZoneHVAC) Outputs
Zone Radiant HVAC Heating Rate [W]
Zone Radiant HVAC Heating Energy [J]
Zone Radiant HVAC Gas Rate [W]
Zone Radiant HVAC Gas Energy [J]
Zone Radiant HVAC Electric Power[W]
Zone Radiant HVAC Electric Energy [J]
ZoneHVAC:VentilatedSlab
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Surface Name or Radiant Surface Group Name
Field: Maximum Air Flow Rate
Field: Outdoor Air Control Type
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Schedule Name
Field: Maximum Outdoor Air Flow Rate
Field: Maximum Outdoor Air Fraction or Temperature Schedule Name
Field: System Configuration Type
Field: Hollow Core Inside Diameter
Field: Hollow Core Length
Field: Number of Cores
Field: Temperature Control Type
Field: Heating High Air Temperature Schedule Name
Field: Heating Low Air Temperature Schedule Name
Field: Heating High Control Temperature Schedule Name
Field: Heating Low Control Temperature Schedule Name
Field: Cooling High Air Temperature Schedule Name
Field: Cooling Low Air Temperature Schedule Name
Field: Cooling High Control Temperature Schedule Name
Field: Cooling Low Control Temperature Schedule Name
Field: Return Air Node Name
Field: Slab In Node Name
Field: Zone Supply Air Node Name
Field: Outdoor Air Node Name
Field: Relief Air Node Name
Field: Outdoor Air Mixer Outlet Node Name
Field: Fan Outlet Node Name
Field: Fan Name
Field: Coil Option Type
Field: Heating Coil Object Type
Field: Heating Coil Name
Field: Hot Water or Steam Inlet Node Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Cold Water Inlet Node Name
Field: Availability Manager List Name
Ventilated Slab (ZoneHVAC) Outputs
Zone Ventilated Slab Radiant Heating Rate [W]
Zone Ventilated Slab Radiant Heating Energy [J]
Zone Ventilated Slab Radiant Cooling Rate [W]
Zone Ventilated Slab Radiant Cooling Energy [J]
Zone Ventilated Slab Coil Heating Rate [W]
Zone Ventilated Slab Coil Heating Energy [J]
Zone Ventilated Slab Coil Total Cooling Rate [W]
Zone Ventilated Slab Coil Total Cooling Energy [J]
Zone Ventilated Slab Coil Sensible Cooling Rate [W]
Zone Ventilated Slab Coil Sensible Cooling Energy [J]
Zone Ventilated Slab Coil Latent Cooling Rate [W]
Zone Ventilated Slab Coil Latent Cooling Energy [J]
Zone Ventilated Slab Air Mass Flow Rate [kg/s]
Zone Ventilated Slab Fan Electric Power [W]
Zone Ventilated Slab Fan Electric Energy [J]
Zone Ventilated Slab Inlet Air Temperature [C]
Zone Ventilated Slab Outlet Air Temperature [C]
Zone Ventilated Slab Zone Inlet Air Temperature [C]
Zone Ventilated Slab Return Air Temperature [C]
Zone Ventilated Slab Fan Outlet Air Temperature [C]
Zone Ventilated Slab Fan Availability Status []
ZoneHVAC:VentilatedSlab:SlabGroup
Field : Name of Ventilated Slab Surface Group
Field: Zone Name
Field: Surface Name
Field: Core Diameter
Field: Core length
Field: Number of Cores
Field: Slab Inlet Node Name
Field: Slab Outlet Node Name
Group – Refrigeration
Refrigeration:CompressorRack
Field: Name
Field: Heat Rejection Location
Field: Design Compressor Rack COP
Field: Compressor Rack COP Function of Temperature Curve Name
Field: Design Condenser Fan Power
Field: Condenser Fan Power Function of Temperature Curve Name
Field: Condenser Type
Field: Water-cooled Condenser Inlet Node Name
Field: Water-cooled Condenser Outlet Node Name
Field: Water-cooled Loop Flow Type
Field: Water-cooled Condenser Outlet Temperature Schedule Name
Field: Water-cooled Condenser Design Flow Rate
Field: Water-cooled Condenser Maximum Flow Rate
Field: Water-cooled Condenser Maximum Water Outlet Temperature
Field: Water-cooled Condenser Minimum Water Inlet Temperature
Field: Evaporative Condenser Availability Schedule Name
Field: Evaporative Condenser Effectiveness
Field: Evaporative Condenser Air Flow Rate
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Design Evaporative Condenser Water Pump Power
Field: Evaporative Water Supply Tank Name
Field: Condenser Air Inlet Node Name
Field: End-Use Subcategory
Field: Refrigeration Case Name or WalkIn Name or CaseAndWalkInList Name
Field: Heat Rejection Zone Name
Refrigeration Compressor Rack Outputs
Refrigeration Compressor Rack Condenser Mass Flow Rate [kg/s]
Refrigeration Compressor Rack Condenser Heat Transfer Rate [W]
Refrigeration Compressor Rack Condenser Heat Transfer Energy [J]
IF THE RACK SERVES CASES AND OR WALKINS:
Refrigeration Compressor Rack Electric Power [W]
Refrigeration Compressor Rack Electric Energy [J]
Refrigeration Compressor Runtime Fraction []
Refrigeration Compressor Rack Condenser Fan Electric Power [W]
Refrigeration Compressor Rack Condenser Fan Electric Energy [J]
Refrigeration Compressor Rack Total Heat Transfer Rate [W]
Refrigeration Compressor Rack Total Heat Transfer Energy [J]
Refrigeration Compressor Rack COP [W/W]
Refrigeration Compressor Rack Evaporative Condenser Pump Electric Power [W]
Refrigeration Compressor Rack Evaporative Condenser Pump Electric Energy [J]
Refrigeration Compressor Rack Evaporative Condenser Basin Heater Electric Power [W]
Refrigeration Compressor Rack Evaporative Condenser Basin Heater Electric Energy [J]
Refrigeration Compressor Rack Evaporative Condenser Water Volume Flow Rate [m3/s]
Refrigeration Compressor Rack Evaporative Condenser Water Volume [m3]
Refrigeration Compressor Rack Zone Sensible Heating Rate [W]
Refrigeration Compressor Rack Zone Sensible Heating Energy [J]
Refrigeration Compressor Rack Return Air Sensible Heating Rate [W]
Refrigeration Compressor Rack Return Air Sensible Heating Energy [J]
IF THE RACK SERVES CHILLERS
Refrigeration Air Chiller Compressor Rack Electric Power [W]
Refrigeration Air Chiller Compressor Rack Electric Energy [J]
Refrigeration Air Chiller System Compressor Runtime Fraction []
Refrigeration Air Chiller Compressor Rack Condenser Fan Electric Power [W]
Refrigeration Air Chiller Compressor Rack Condenser Fan Electric Energy [J]
Refrigeration Air Chiller Compressor Rack Total Heat Transfer Rate [W]
Refrigeration Air Chiller Compressor Rack Total Heat Transfer Energy [J]
Refrigeration Air Chiller Compressor Rack COP [W/W]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Pump Electric Power [W]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Pump Electric Energy [J]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Basin Heater Electric Power [W]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Basin Heater Electric Energy [J]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Water Volume Flow Rate [m3/s]
Refrigeration Air Chiller Compressor Rack Evaporative Condenser Water Volume [m3]
Refrigeration Air Chiller Compressor Rack Zone Sensible Heating Rate [W]
Refrigeration Air Chiller Compressor Rack Zone Sensible Heating Energy [J]
Refrigeration Air Chiller Compressor Rack Return Air Sensible Heating Energy [J]
Refrigeration Air Chiller Compressor Rack Return Air Sensible Heating Rate [W]
Refrigeration:Case
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Rated Ambient Temperature
Field: Rated Ambient Relative Humidity
Field: Rated Total Cooling Capacity per Unit Length
Field: Rated Latent Heat Ratio
Field: Rated Runtime Fraction
Field: Case Length
Field: Case Operating Temperature
Field: Latent Case Credit Curve Type
Field: Latent Case Credit Curve Name
Field: Standard Case Fan Power per Unit Length
Field: Operating Case Fan Power per Unit Length
Field: Standard Case Lighting Power per Unit Length
Field: Installed Case Lighting Power per Unit Length
Field: Case Lighting Schedule Name
Field: Fraction of Lighting Energy To Case
Field: Case Anti-Sweat Heater Power per Unit Length
Field: Minimum Anti-Sweat Heater Power per Unit Length
Field: Anti-Sweat Heater Control Type
Field: Humidity at Zero Anti-Sweat Heater Energy
Field: Case Height
Field: Fraction of Anti-Sweat Heater Energy To Case
Field: Case Defrost Power per Unit Length
Field: Case Defrost Type
Field: Case Defrost Schedule Name
Field: Case Defrost Drip-Down Schedule Name
Field: Defrost Energy Correction Curve Type
Field: Defrost Energy Correction Curve Name
Field: Under Case HVAC Return Air Fraction
Field: Refrigerated Case Restocking Schedule Name
Field: Case Credit Fraction Schedule Name
Field: Design Evaporator Temperature or Brine Inlet Temperature
Field: Average Refrigerant Charge Inventory
Refrigeration:Case Outputs
Refrigeration Case Evaporator Total Cooling Rate [W]
Refrigeration Case Evaporator Total Cooling Energy [J]
Refrigeration Case Evaporator Sensible Cooling Rate [W]
Refrigeration Case Evaporator Sensible Cooling Energy [J]
Refrigeration Case Evaporator Latent Cooling Rate [W]
Refrigeration Case Evaporator Latent Cooling Energy [J]
Refrigeration Case Zone Sensible Cooling Rate [W]
Refrigeration Case Zone Sensible Cooling Energy [J]
Refrigeration Case Zone Sensible Heating Rate [W]
Refrigeration Case Zone Sensible Heating Energy [J]
Refrigeration Case Zone Latent Rate [W]
Refrigeration Case Zone Latent Energy [J]
Refrigeration Case Return Air Sensible Cooling Rate [W]
Refrigeration Case Return Air Sensible Cooling Energy [J]
Refrigeration Case Return Air Sensible Heating Rate [W]
Refrigeration Case Return Air Sensible Heating Energy [J]
Refrigeration Case Return Air Latent Energy [J]
Refrigeration Case Return Air Latent Rate [W]
Refrigeration Case Evaporator Fan Electric Power [W]
Refrigeration Case Evaporator Fan Electric Energy [J]
Refrigeration Case Lighting Electric Power [W]
Refrigeration Case Lighting Electric Energy [J]
Refrigeration Case Defrost Energy Correction Curve Value
Refrigeration Case Latent Credit Curve Value []
Refrigeration Case Anti Sweat Electric Power [W]
Refrigeration Case Anti Sweat Electric Energy [J]
Refrigeration Case Defrost Electric Power [W]
Refrigeration Case Defrost Electric Energy [J]
Refrigeration:CaseAndWalkInList
Field: Name
Field: Case or WalkIn or Air Chiller Name
Refrigeration:WalkIn
Field: Name
Field: Availability Schedule Name
Field: Rated Coil Cooling Capacity
Field: Operating Temperature
Field: Rated Cooling Source Temperature
Field: Rated Total Heating Power
Field: Heating Power Schedule Name
Field: Rated Cooling Coil Fan Power
Field: Rated Circulation Fan Power
Field: Rated Total Lighting Power
Field: Lighting Schedule Name
Field: Defrost Type
Field: Defrost Control Type
Field: Defrost Schedule Name
Field: Defrost Drip-Down Schedule Name
Field: Defrost Power
Field: Temperature Termination Defrost Fraction to Ice
Field: Restocking Schedule Name
Field: Average Refrigerant Charge Inventory
Field: Insulated Floor Surface Area
Field: Insulated Floor U-Value
Field: Zone Name
Field: Total Insulated Surface Area Facing Zone
Field: Insulated Surface U-Value Facing Zone
Field: Area of Glass Reach In Doors Facing Zone
Field: Height of Glass Reach In Doors Facing Zone
Field: Glass Reach In Door U-Value Facing Zone
Field: Glass Reach In Door Opening Schedule Name Facing Zone
Field: Area of Stocking Doors Facing Zone
Field: Height of Stocking Doors Facing Zone
Field: Stocking Door U-Value Facing Zone
Field: Stocking Door Opening Schedule Name Facing Zone
Field: Stocking Door Opening Protection Type Facing Zone
Refrigeration Case and WalkIn Outputs
Refrigeration Walk In Evaporator Total Cooling Rate [W]
Refrigeration Walk In Evaporator Total Cooling Energy [J]
Refrigeration Walk In Evaporator Sensible Cooling Rate [W]
Refrigeration Walk In Evaporator Sensible Cooling Energy [J]
Refrigeration Walk In Evaporator Latent Cooling Rate [W]
Refrigeration Walk In Evaporator Latent Cooling Energy [J]
Refrigeration Walk In Ancillary Electric Power [W]
Refrigeration Walk In Ancillary Electric Energy [J]
Refrigeration Walk In Fan Electric Power [W]
Refrigeration Walk In Fan Electric Energy [J]
Refrigeration Walk In Lighting Electric Power [W]
Refrigeration Walk In Lighting Electric Energy [J]
Refrigeration Walk In Heater Electric Power [W]
Refrigeration Walk In Heater Electric Energy [J]
Refrigeration Walk In Defrost Electric Power [W]
Refrigeration Walk In Defrost Electric Energy [J]
Refrigeration Walk In Zone Sensible Cooling Rate [W]
Refrigeration Walk In Zone Sensible Cooling Energy [J]
Refrigeration Walk In Zone Sensible Heating Rate [W]
Refrigeration Walk In Zone Sensible Heating Energy [J]
Refrigeration Walk In Zone Latent Rate [W]
Refrigeration Walk In Zone Latent Energy [J]
Refrigeration:System
Field: Name
Field: Refrigerated Case or WalkIn or CaseAndWalkInList Name
Field: Refrigeration Transfer Load or TransferLoad List Name
Field: Condenser Name
Field:Compressor or Compressor List Name
Field: Minimum Condensing Temperature
Field: Refrigeration System Working Fluid Type
Field: Suction Temperature Control Type
Field: Mechanical Subcooler Name
Field: Liquid Suction Heat Exchanger Subcooler Name
Field: Sum UA Suction Piping
Field: Suction Piping Zone Name
Field: End-Use Subcategory
Field: Number of Compressor Stages
Field: Intercooler Type
Field: Shell-and-Coil Intercooler Effectiveness
Field: High-Stage Compressor or CompressorList Name
Refrigeration System Outputs
THE FOLLOWING OUTPUTS ARE AVAILABLE FOR SYSTEMS THAT SERVE CASES AND/OR WALKINS
Refrigeration System Total Compressor Electric Power [W]
Refrigeration System Total Compressor Electric Consumption [J]
Refrigeration System Total Low Stage Compressor Electric Power [W]
Refrigeration System Total Low Stage Compressor Electric Energy [J]
Refrigeration System Total High Stage Compressor Electric Power [W]
Refrigeration System Total High Stage Compressor Electric Energy [J]
Refrigeration System Total Low and High Stage Compressor Electric Energy [J]
Refrigeration System Average Compressor COP [W/W]
Refrigeration System Total Compressor Heat Transfer Rate [W]
Refrigeration System Total Compressor Heat Transfer Energy [J]
Refrigeration System Total Low Stage Compressor Heat Transfer Rate [W]
Refrigeration System Total Low Stage Compressor Heat Transfer Energy [J]
Refrigeration System Total High Stage Compressor Heat Transfer Rate [W]
Refrigeration System Total High Stage Compressor Heat Transfer Energy [J]
Refrigeration System Total Cases and Walk Ins Heat Transfer Rate [W]
Refrigeration System Total Cases and Walk Ins Heat Transfer Energy [J]
Refrigeration System Total Transferred Load Heat Transfer Rate [W]
Refrigeration System Total Transferred Load Heat Transfer Energy [J]
Refrigeration System Total Suction Pipe Heat Gain Rate [W]
Refrigeration System Total Suction Pipe Heat Gain Energy [J]
Refrigeration System Net Rejected Heat Transfer Rate [W]
Refrigeration System Net Rejected Heat Transfer Energy [J]
Refrigeration System Liquid Suction Subcooler Heat Transfer Rate [W]
Refrigeration System Liquid Suction Subcooler Heat Transfer Energy [J]
Refrigeration System Estimated Refrigerant Inventory Mass [kg]
Refrigeration System Estimated Refrigerant Mass Flow Rate [kg/s]
Refrigeration System Estimated Low Stage Refrigerant Mass Flow Rate [kg/s]
Refrigeration System Estimated High Stage Refrigerant Mass Flow Rate [kg/s]
Refrigeration System Intercooler Temperature [C]
Refrigeration System Intercooler Pressure [Pa]
Refrigeration System Condensing Temperature [C]
Refrigeration System Evaporating Temperature [C]
Refrigeration System Suction Pipe Suction Temperature [C]
Refrigeration System Thermostatic Expansion Valve Liquid Temperature [C]
THE FOLLOWING OUTPUTS ARE AVAILABLE FOR SYSTEMS THAT SERVE AIR CHILLERS
Refrigeration Air Chiller System Total Compressor Electric Power [W]
Refrigeration Chiller System Total Compressor Electric Consumption [J]
Refrigeration Air Chiller System Total Low Stage Compressor Electric Power [W]
Refrigeration Air Chiller System Total Low Stage Compressor Electric Energy [J]
Refrigeration Air Chiller System Total High Stage Compressor Electric Power [W]
Refrigeration Air Chiller System Total High Stage Compressor Electric Energy [J]
Refrigeration Air Chiller System Total Low and High Stage Compressor Electric Energy [J]
Refrigeration Air Chiller System Average Compressor COP [W/W]
Refrigeration Air Chiller System Total Compressor Heat Transfer Rate [W]
Refrigeration Air Chiller System Total Compressor Heat Transfer Energy [J]
Refrigeration Air Chiller System Total Low Stage Compressor Heat Transfer Rate [W]
Refrigeration Air Chiller System Total Low Stage Compressor Heat Transfer Energy [J]
Refrigeration Air Chiller System Total High Stage Compressor Heat Transfer Rate [W]
Refrigeration Air Chiller System Total High Stage Compressor Heat Transfer Energy [J]
Refrigeration Air Chiller System Total Air Chiller Heat Transfer Rate [W]
Refrigeration Air Chiller System Total Case and Walk In Heat Transfer Energy [J]
Refrigeration Air Chiller System Total Transferred Load Heat Transfer Rate [W]
Refrigeration Air Chiller System Total Transferred Load Heat Transfer Energy [J]
Refrigeration Air Chiller System Total Suction Pipe Heat Gain Rate [W]
Refrigeration Air Chiller System Total Suction Pipe Heat Gain Energy [J]
Refrigeration Air Chiller System Net Rejected Heat Transfer Rate [W]
Refrigeration Air Chiller System Net Rejected Heat Transfer Energy [J]
Refrigeration Air Chiller System Liquid Suction Subcooler Heat Transfer Rate [W]
Refrigeration Air Chiller System Liquid Suction Subcooler Heat Transfer Energy [J]
Refrigeration Air Chiller System Mechanical Subcooler Heat Transfer Energy [J]
Refrigeration Air Chiller System Estimated Refrigerant Inventory Mass [kg]
Refrigeration Air Chiller System Estimated Refrigerant Mass Flow Rate [kg/s]
Refrigeration Air Chiller System Estimated Low Stage Refrigerant Mass Flow Rate [kg/s]
Refrigeration Air Chiller System Estimated High Stage Refrigerant Mass Flow Rate [kg/s]
Refrigeration Air Chiller System Intercooler Temperature [C]
Refrigeration Air Chiller System Intercooler Pressure [Pa]
Refrigeration Air Chiller System Condensing Temperature [C]
Refrigeration Air Chiller System Evaporating Temperature [C]
Refrigeration Air Chiller System Suction Temperature [C]
Refrigeration Air Chiller System TXV Liquid Temperature [C]
Refrigeration:TranscriticalSystem
Field: Name
Field: System Type
Field: Medium Temperature Refrigerated Case or WalkIn or CaseAndWalkInList Name
Field: Low Temperature Refrigerated Case or WalkIn or CaseAndWalkInList Name
Field: Refrigeration Gas Cooler Name
Field: High Pressure Compressor or Compressor List Name
Field: Low Pressure Compressor or Compressor List Name
Field: Receiver Pressure
Field: Subcooler Effectiveness
Field: Refrigeration System Working Fluid Type
Field: Sum UA Suction Piping for Medium Temperature Loads
Field: Medium Temperature Suction Piping Zone Name
Field: Sum UA Suction Piping for Low Temperature Loads
Field: Low Temperature Suction Piping Zone Name
Field: End-Use Subcategory
Refrigeration Transcritical System Outputs
Refrigeration Transcritical System Total High Pressure Compressor Electric Power [W]
Refrigeration Transcritical System Total High Pressure Compressor Electric Energy [J]
Refrigeration Transcritical System Low Pressure Compressor Electric Power [W]
Refrigeration Transcritical System Low Pressure Compressor Electric Energy [J]
Refrigeration Transcritical System Total Compressor Electric Energy [J]
Refrigeration Transcritical System Average COP [W/W]
Refrigeration Transcritical System Medium Temperature Cases and Walk Ins Heat Transfer Rate [W]
Refrigeration Transcritical System Medium Temperature Cases and Walk Ins Heat Transfer Energy [J]
Refrigeration Transcritical System Low Temperature Cases and Walk Ins Heat Transfer Rate [W]
Refrigeration Transcritical System Low Temperature Cases and Walk Ins Heat Transfer Energy [J]
Refrigeration Transcritical System Total Cases and Walk Ins Heat Transfer Energy [J]
Refrigeration Transcritical System Medium Temperature Suction Pipe Heat Transfer Rate [W]
Refrigeration Transcritical System Medium Temperature Suction Pipe Heat Transfer Energy [J]
Refrigeration Transcritical System Low Temperature Suction Pipe Heat Transfer Rate [W]
Refrigeration Transcritical System Low Temperature Suction Pipe Heat Transfer Energy [J]
Refrigeration Transcritical System High Pressure Compressor Heat Transfer Rate [W]
Refrigeration Transcritical System High Pressure Compressor Heat Transfer Energy [J]
Refrigeration Transcritical System Low Pressure Compressor Heat Transfer Rate [W]
Refrigeration Transcritical System Low Pressure Compressor Heat Transfer Energy [J]
Refrigeration Transcritical System Net Rejected Heat Transfer Rate [W]
Refrigeration Transcritical System Net Rejected Heat Transfer Energy [J]
Refrigeration Transcritical System Estimated Refrigerant Inventory Mass [kg]
Refrigeration Transcritical System Refrigerant Mass Flow Rate [kg/s]
Refrigeration Transcritical System Medium Temperature Evaporating Temperature [C]
Refrigeration Transcritical System Medium Temperature Suction Temperature [C]
Refrigeration Transcritical System Low Temperature Evaporating Temperature [C]
Refrigeration Transcritical System Low Temperature Suction Temperature [C]
Refrigeration:Compressor
Field: Name
Field: Refrigeration Compressor Power Curve Name
Field: Refrigeration Compressor Capacity Curve Name
Field: Rated Superheat
Field: Rated Return Gas Temperature
Field: Rated Liquid Temperature
Field: Rated Subcooling
Field: End-Use Subcategory
Refrigeration Compressor Outputs
THE FOLLOWING OUTPUTS ARE AVAILABLE FOR SYSTEMS THAT SERVE CASES AND/OR WALKINS
Refrigeration Compressor Electric Power [W]
Refrigeration Compressor Electric Energy [J]
Refrigeration Compressor Heat Transfer Rate [W]
Refrigeration Compressor Heat Transfer Energy [J]
Refrigeration Compressor Run Time Fraction []
THE FOLLOWING OUTPUTS ARE AVAILABLE FOR SYSTEMS THAT SERVE AIR CHILLERS
Refrigeration Air Chiller System Compressor Electric Power [W]
Refrigeration Air Chiller System Compressor Electric Energy [J]
Refrigeration Air Chiller System Compressor Heat Transfer Rate [W]
Refrigeration Air Chiller System Compressor Heat Transfer Energy [J]
Refrigeration Chiller Compressor Run Time Fraction []
Refrigeration:CompressorList
Field: Name
Field: Refrigeration Compressor Name
Refrigeration:Subcooler
Field: Name
Field: Subcooler Type
Field: Liquid Suction Design Subcooling Temperature Difference
Field: Design Liquid Inlet Temperature
Field: Design Vapor Inlet Temperature
Field: Capacity-Providing System
Field: Outlet Control Temperature
Refrigeration Subcooler Outputs
FOR SUBCOOLERS ON SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration System Mechanical Subcooler Heat Transfer Rate [W]
Refrigeration System Mechanical Subcooler Heat Transfer Energy [J]
FOR SUBCOOLERS ON SYSTEMS SERVING AIR CHILLERS
Refrigeration Air Chiller System Mechanical Subcooler Heat Transfer Rate [W]
Refrigeration Air Chiller System Mechanical Subcooler Heat Transfer Energy [J]
Refrigeration:Condenser:AirCooled
Field: Name
Field: Rated Effective Total Heat Rejection Rate Curve Name
Field: Rated Subcooling Temperature Difference
Field: Condenser Fan Speed Control Type
Field: Rated Fan Power
Field: Minimum Fan Air Flow Ratio
Field: Air Inlet Node Name or Zone Name
Field: End-Use Subcategory
Field: Condenser Refrigerant Operating Charge Inventory
Field: Condensate Receiver Refrigerant Inventory
Field: Condensate Piping Refrigerant Inventory
Refrigeration Condenser (AirCooled) Outputs
FOR CONDENSERS ON SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration System Condenser Fan Electric Power [W]
Refrigeration System Condenser Fan Electric Consumption [J]
Refrigeration System Condenser Heat Transfer Rate [W]
Refrigeration System Condenser Heat Transfer Energy [J]
Refrigeration System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Non Refrigeration Recovered Heat Transfer Energy [J]
Refrigeration System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Defrost Recovered Heat Transfer Energy [J]
FOR CONDENSERS ON SYSTEMS SERVING AIR CHILLERS:
Refrigeration Air Chiller System Condenser Fan Electric Power [W]
Refrigeration Air Chiller System Condenser Fan Electric Energy [J]
Refrigeration Air Chiller System Condenser Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Defrost Recovered Heat Transfer Energy [J]
Refrigeration:Condenser:EvaporativeCooled
Field: Name
Field: Rated Effective Total Heat Rejection Rate
Field: Rated Subcooling Temperature Difference
Field: Fan Speed Control Type
Field: Rated Fan Power
Field: Minimum Fan Air Flow Ratio
Field: Approach Temperature Constant Term
Field: Approach Temperature Coefficient 2
Field: Approach Temperature Coefficient 3
Field: Approach Temperature Coefficient 4
Field: Mimimum Capacity Factor
Field: Maximum Capacity Factor
Field: Air Inlet Node Name
Field: Rated Air Flow Rate
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Rated Water Pump Power
Field: Evaporative Water Supply Tank Name
Field: Evaporative Condenser Availability Schedule Name
Field: End-Use Subcategory
Field: Condenser Refrigerant Operating Charge Inventory
Field: Condensate Receiver Refrigerant Inventory
Field: Condensate Piping Refrigerant Inventory
Refrigeration Condenser (EvaporativeCooled) Outputs
FOR CONDENSERS ON SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration System Condenser Fan Electric Power [W]
Refrigeration System Condenser Fan Electric Energy [J]
Refrigeration System Condenser Heat Transfer Rate [W]
Refrigeration System Condenser Heat Transfer Energy [J]
Refrigeration System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Heat Recovered for Non-Refrigeration Purposes Energy [J]
Refrigeration System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Defrost Recovered Heat Transfer Energy [J]
Refrigeration System Condenser Pump Electric Power [W]
Refrigeration System Condenser Pump Electric Energy [J]
Refrigeration System Condenser Basin Heater Electric Power [W]
Refrigeration System Condenser Basin Heater Electric Energy [J]
Refrigeration System Condenser Evaporated Water Volume Flow Rate [m3/s]
Refrigeration System Condenser Evaporated Water Volume [m3]
FOR CONDENSERS ON SYSTEMS SERVING AIR CHILLERS:
Refrigeration Air Chiller System Condenser Fan Electric Power [W]
Refrigeration Air Chiller System Condenser Fan Electric Energy [J]
Refrigeration Air Chiller System Condenser Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Defrost Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Pump Electric Power [W]
Refrigeration Air Chiller System Condenser Pump Electric Energy [J]
Refrigeration Air Chiller System Condenser Basin Heater Electric Power [W]
Refrigeration Air Chiller System Condenser Basin Heater Electric Energy [J]
Refrigeration Air Chiller System Condenser Evaporated Water Volume Flow Rate [m3/s]
Refrigeration Air Chiller System Condenser Evaporated Water Volume [m3]
Refrigeration:Condenser:WaterCooled
Field: Name
Field: Rated Effective Total Heat Rejection Rate
Field: Rated Condensing Temperature
Field: Rated Subcooling Temperature Difference
Field: Rated Water Inlet Temperature
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Water-Cooled Loop Flow Type
Field: Water Outlet Temperature Schedule Name
Field: Water Design Flow Rate
Field: Water Maximum Flow Rate
Field: Maximum Water Outlet Temperature
Field: Minimum Water Inlet Temperature
Field: End-Use Subcategory
Field: Condenser Refrigerant Operating Charge Inventory
Field: Condensate Receiver Refrigerant Inventory
Field: Condensate Piping Refrigerant Inventory
Refrigeration Condenser (WaterCooled) Outputs
FOR CONDENSERS ON SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration System Condenser Heat Transfer Rate [W]
Refrigeration System Condenser Heat Transfer Energy [J]
Refrigeration System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Heat Recovered for Non-Refrigeration Purposes Energy [J]
Refrigeration System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration System Condenser Heat Energy Recovered for Refrigeration Defrost Energy [J]
Refrigeration System Condenser Water Mass Flow Rate [kg/s]
FOR CONDENSERS ON SYSTEMS SERVING AIR CHILLERS:
Refrigeration Air Chiller System Condenser Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Total Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Non Refrigeration Recovered Heat Transfer Energy [J]
Refrigeration Air Chiller System Condenser Defrost Recovered Heat Transfer Rate [W]
Refrigeration Chiller System Condenser Heat Energy Recovered for Refrigeration Defrost Energy [J]
Refrigeration Air Chiller System Condenser Fluid Mass Flow Rate [kg/s]
Refrigeration:Condenser:Cascade
Field: Name
Field: Rated Condensing Temperature
Field: Rated Approach Temperature Difference
Field: Rated Effective Total Heat Rejection Rate
Field: Condensing Temperature Control Type
Field: Condenser Refrigerant Operating Charge Inventory
Field: Condensate Receiver Refrigerant Inventory
Field: Condensate Piping Refrigerant Inventory
Refrigeration Condenser (Cascade) Outputs
FOR CONDENSERS ON SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration System Condenser Heat Transfer Rate [W]
Refrigeration System Condenser Heat Transfer Energy [J]
FOR CONDENSERS ON SYSTEMS SERVING AIR CHILLERS:
Refrigeration Air Chiller System Condenser Heat Transfer Rate [W]
Refrigeration Air Chiller System Condenser Heat Transfer Energy [J]
Refrigeration:GasCooler:AirCooled
Field: Name
Field: Rated Total Heat Rejection Rate Curve Name
Field: Gas Cooler Fan Speed Control Type
Field: Rated Fan Power
Field: Minimum Fan Air Flow Ratio
Field: Transition Temperature
Field: Transcritical Approach Temperature
Field: Subcritical Temperature Difference
Field: End-Use Subcategory
Field: Gas Cooler Refrigerant Operating Charge Inventory
Field: Gas Cooler Receiver Refrigerant Inventory
Field: Gas Cooler Outlet Piping Refrigerant Inventory
Refrigeration GasCooler (AirCooled) Outputs
Refrigeration Transcritical System Gas Cooler Heat Transfer Rate [W]
Refrigeration Transcritical System Gas Cooler Heat Transfer Energy [J]
Refrigeration Transcritical System Gas Cooler Fan Electric Power [W]
Refrigeration Transcritical System Gas Cooler Fan Electric Energy [J]
Refrigeration Transcritical System Gas Cooler Outlet Temperature [C]
Refrigeration Transcritical System Gas Cooler Outlet Pressure [Pa]
Refrigeration Transcritical System Gas Cooler Defrost Recovered Heat Transfer Rate [W]
Refrigeration Transcritical System Gas Cooler Defrost Recovered Heat Transfer Energy [J]
Refrigeration:TransferLoadList
Field: Name
Field: Cascade Condenser Name or Secondary System Name
Refrigeration:SecondarySystem
Field: Name
Field: Refrigerated Case or WalkIn or CaseAndWalkInList Name
Field: Circulating Fluid Type
Field: Circulating Fluid Name
Field: Evaporator Capacity
Field: Evaporator Flow Rate for Secondary Fluid
Field:Evaporator Evaporating Temperature
Field: Evaporator Approach Temperature Difference
Field: Evaporator Range Temperature Difference
Field: Number of Pumps in Loop
Field: Total Pump Flow Rate
Field: Total Pump Power
Field: Total Pump Head
Field: PhaseChange Circulating Rate
Field: Pump Drive Type
Field: Variable Speed Pump Cubic Curve Name
Field: Pump Motor Heat to Fluid
Field: Sum UA Distribution Piping
Field: Distribution Piping Zone Name
Field: Sum UA Receiver/Separator Shell
Field: Receiver/Separator Zone Name
Field: Evaporator Refrigerant Inventory
Field: End-Use Subcategory
Refrigeration Secondary System Outputs
FOR SECONDARY SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration Secondary Loop Pump Electric Power [W]
Refrigeration Secondary Loop Pump Electric Energy [J]
Refrigeration Secondary Loop Load Heat Transfer Rate [W]
Refrigeration Secondary Loop Load Heat Transfer Energy [J]
Refrigeration Secondary Loop Total Heat Transfer Rate [W]
Refrigeration Secondary Loop Total Heat Transfer Energy [J]
Refrigeration Secondary Loop Estimated Refrigerant Inventory Mass [kg]
Refrigeration Secondary Loop Volume Flow Rate [m3/]s
Refrigeration Secondary Loop Pipe Heat Gain Rate [W]
Refrigeration Secondary Loop Pipe Heat Gain Energy [J]
Refrigeration Secondary Loop Receiver Heat Gain Rate [W]
Refrigeration Secondary Loop Receiver Heat Gain Energy [J]
FOR SECONDARY SYSTEMS SERVING AIR CHILLERS:
Refrigeration Air Chiller Secondary Loop Pump Electric Power [W]
Refrigeration Air Chiller Secondary Loop Pump Electric Energy [J]
Refrigeration Air Chiller Secondary Loop Load Heat Transfer Rate [W]
Refrigeration Air Chiller Secondary Loop Load Heat Transfer Energy [J]
Refrigeration Air Chiller Secondary Loop Total Heat Transfer Rate [W]
Refrigeration Air Chiller Secondary Loop Total Heat Transfer Energy [J]
Refrigeration Air Chiller Secondary Loop Estimated Refrigerant Inventory Mass [kg]
Refrigeration Air Chiller Secondary Loop Volume Flow Rate [m3/]s
Refrigeration Air Chiller Secondary Loop Pipe Heat Gain Rate [W]
Refrigeration Air Chiller Secondary Loop Pipe Heat Gain Energy [J]
Refrigeration Air Chiller Secondary Loop Receiver Heat Gain Rate [W]
Refrigeration Air Chiller Secondary Loop Receiver Heat Gain Energy [J]
Additional Refrigeration Outputs Available for Each Zone
Additional Refrigeration Outputs for Each Zone
FOR THE SUM OF ALL COOLING SYSTEMS SERVING CASES AND/OR WALKINS:
Refrigeration Zone Case and Walk In Total Sensible Cooling Rate [W]
Refrigeration Zone Case and Walk In Total Latent Cooling Rate [W]
Refrigeration Zone Case and Walk In Total Heat Transfer Rate [W]
Refrigeration Zone Case and Walk In Sensible Cooling Rate [W]
Refrigeration Zone Case and Walk In Heating Rate [W]
Refrigeration Zone Case and Walk In Total Cooling Rate [W]
FOR THE SUM OF ALL COOLING SYSTEMS SERVING AIR CHILLERS:
Refrigeration Zone Air Chiller Heating Rate [W]
Refrigeration Zone Air Chiller Sensible Cooling Rate [W]
Refrigeration Zone Air Chiller Sensible Heat Transfer Rate [W]
Refrigeration Zone Air Chiller Sensible Heat Transfer Energy [J]
Refrigeration Zone Air Chiller Latent Cooling Rate [W]
Refrigeration Zone Air Chiller Water Removed Mass Flow Rate [kg/s]
Refrigeration Zone Air Chiller Total Cooling Rate [W]
Refrigeration:AirChiller
Field: Name
Field: Availability Schedule Name
Field: Capacity Rating Type
NOTE – ONLY ONE OF THE FOLLOWING TWO FIELDS IS USED
Field: Rated Unit Load Factor
Field: Rated Capacity
Field: Rated Relative Humidity
Field: Rated Cooling Source Temperature
Field: Rated Temperature Difference DT1
Field: Maximum Difference Between Inlet Air and Evaporating Temperature
Field: Coil Material Correction Factor
Field: Refrigerant Correction Factor
Field: Capacity Correction Curve Type
Field: Capacity Correction Curve Name
Field: SHR60 Correction Factor
Field: Rated Total Heating Power
Field: Heating Power Schedule Name
Field: Fan Speed Control Type
Field: Rated Fan Power
Field: Rated Air Flow
Field: Minimum Fan Air Flow Ratio
Field: Defrost Type
Field: Defrost Control Type
Field: Defrost Schedule Name
Field: Defrost Drip-Down Schedule Name
Field: Defrost Power
Field: Temperature Termination Defrost Fraction to Ice
Field:Vertical Location
Field: Average Refrigerant Charge Inventory
Refrigeration Air Chiller Outputs
Refrigeration Zone Air Chiller Total Cooling Rate [W]
Refrigeration Zone Air Chiller Total Cooling Energy [J]
Refrigeration Zone Air Chiller Sensible Cooling Rate [W]
Refrigeration Zone Air Chiller Sensible Heat Transfer Rate [W]
Refrigeration Zone Air Chiller Sensible Cooling Energy [J]
Refrigeration Zone Air Chiller Sensible Heat Transfer Energy [J]
Refrigeration Zone Air Chiller Latent Cooling Rate [W]
Refrigeration Zone Air Chiller Latent Cooling Energy [J]
Refrigeration Zone Air Chiller Water Removed Mass Flow Rate [kg/s]
Refrigeration Zone Air Chiller Total Electric Power [W]
Refrigeration Zone Air Chiller Total Electric Energy [J]
Refrigeration Zone Air Chiller Fan Electric Power [W]
Refrigeration Zone Air Chiller Fan Electric Energy [J]
Refrigeration Zone Air Chiller Heater Electric Power [W]
Refrigeration Zone Air Chiller Heater Electric Energy [J]
Refrigeration Zone Air Chiller Defrost Electric Power [W]
Refrigeration Zone Air Chiller Defrost Electric Energy [J]
Refrigeration Zone Air Chiller Sensible Heat Ratio
Refrigeration Zone Air Chiller Frost Accumulation Mass [kg]
Refrigeration Zone Air Chiller Zone Total Cooling Rate [W]
Refrigeration Zone Air Chiller Zone Total Cooling Energy [J]
Refrigeration Zone Air Chiller Zone Sensible Cooling Rate [W]
Refrigeration Zone Air Chiller Zone Sensible Cooling Energy [J]
Refrigeration Zone Air Chiller Zone Heating Rate [W]
Refrigeration Zone Air Chiller Zone Heating Energy [J]
Refrigeration Zone Air Chiller Sensible Cooling Rate [W]
Refrigeration Zone Air Chiller Sensible Cooling Energy [J]
Refrigeration Zone Air Chiller Latent Cooling Rate [W]
Refrigeration Zone Air Chiller Water Removed Mass Flow Rate [kg/s]
Refrigeration Zone Air Chiller Latent Cooling Energy [J]
Refrigeration Zone Air Chiller Total Cooling Rate [W]
Refrigeration Zone Air Chiller Total Cooling Energy [J]
Refrigeration Zone Air Chiller Heating Rate [W]
Refrigeration Zone Air Chiller Heating Energy [J]
Group – Zone Controls – Thermostats and Humidistats
ZoneControl:Thermostat
Field: Name
Field: Zone or ZoneList Name
Field: Control Type Schedule Name
Field Set (Control Object Type, Control Name)
Field: Control Object Type
Field: Control Name
ZoneControl Thermostat Outputs
Zone Predicted Sensible Load to Setpoint Heat Transfer Rate [W]
Zone Predicted Sensible Load to Heating Setpoint Heat Transfer Rate [W]
Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate [W]
Zone Thermostat Control Type []
Zone Thermostat Heating Setpoint Temperature [C]
Zone Thermostat Cooling Setpoint Temperature [C]
Zone Heating Setpoint Not Met Time [hr]
Zone Heating Setpoint Not Met While Occupied Time [hr]
Zone Cooling Setpoint Not Met Time [hr]
Zone Cooling Setpoint Not Met While Occupied Time [hr]
Facility Heating Setpoint Not Met Time [hr]
Facility Heating Setpoint Not Met While Occupied Time [hr]
Facility Cooling Setpoint Not Met Time [hr]
Facility Cooling Setpoint Not Met While Occupied Time [hr]
Zone Oscillating Temperatures Time[hr]
Facility Any Zone Oscillating Temperatures Time[hr]
Zone Thermostat Setpoints
ThermostatSetpoint:SingleHeating
Field: Name
Field: Setpoint Temperature Schedule Name
ThermostatSetpoint:SingleCooling
Field: Name
Field: Setpoint Temperature Schedule Name
ThermostatSetpoint:SingleHeatingOrCooling
Field: Name
Field: Setpoint Temperature Schedule Name
ThermostatSetpoint:DualSetpoint
Field: Name
Field: Heating Setpoint Temperature Schedule Name
Field: Cooling Setpoint Temperature Schedule Name
ZoneControl:Thermostat:OperativeTemperature
Field: Thermostat Name
Field: Radiative Fraction Input Mode
Field: Fixed Radiative Fraction
Field: Radiative Fraction Schedule Name
Zone Control Themostatic Operative Temperature Outputs
Zone Thermostat Operative Temperature [C]
ZoneControl:Thermostat:TemperatureAndHumidity
Field: Thermostat Name
Field: Dehumidifying Relative Humidity Setpoint Schedule Name
Field: Dehumidification Control Type
Field: Overcool Range Input Method
Field: Overcool Constant Range
Field: Overcool Range Schedule Name
Field: Overcool Control Ratio
ZoneControl:Humidistat
Field: Name
Field: Zone Name
Field: Humidifying Relative Humidity Setpoint Schedule Name
Field: Dehumidifying Relative Humidity Setpoint Schedule Name
ZoneControl Humidistat Outputs
Zone Predicted Moisture Load Moisture Transfer Rate [kgWater/s]
Zone Predicted Moisture Load to Humidifying Setpoint Moisture Transfer Rate [kgWater/s]
Zone Predicted Moisture Load to Dehumidifying Setpoint Moisture Transfer Rate [kgWater/s]
ZoneControl:Thermostat:ThermalComfort
Field: Name
Field: Zone or ZoneList Name
Field: Averaging Method
Field: Object Name for Specific Object Averaging Method
Field: Minimum Dry-Bulb Temperature Setpoint
Field: Maximum Dry-Bulb Temperature Setpoint
Field: Thermal Comfort Control Type Schedule Name
Field Set (Thermal Comfort Control Object Type, Thermal Comfort Control Name)
Field: Thermal Comfort Control Object Type
Field: Thermal Comfort Control Name
ZoneControl Thermostat ThermalComfort Outputs
Zone Thermal Comfort Control Type []
Zone Thermal Comfort Control Fanger Low Setpoint PMV []
Zone Thermal Comfort Control Fanger High Setpoint PMV []
Zone Thermostat Heating Setpoint Temperature [C]
Zone Thermostat Cooling Setpoint Temperature [C]
Thermal Comfort Setpoints
ThermostatSetpoint:ThermalComfort:Fanger:SingleHeating
Field: Name
Field: Fanger Thermal Comfort Schedule Name
ThermostatSetpoint:ThermalComfort:Fanger:SingleCooling
Field: Name
Field: Fanger Thermal Comfort Schedule Name
ThermostatSetpoint:ThermalComfort:Fanger:SingleHeatingOrCooling
Field: Name
Field: Fanger Thermal Comfort Schedule Name
ThermostatSetpoint:ThermalComfort:Fanger:DualSetpoint
Field: Name
Field: Fanger Thermal Comfort Heating Schedule Name
Field: Fanger Thermal Comfort Cooling Schedule Name
ZoneControl:ContaminantController
Field: Name
Field: Controlled Zone Name
Field: Carbon Dioxide Control Availability Schedule Name
Field: Carbon Dioxide Setpoint Schedule Name
Field: Minimum Carbon Dioxide Concentration Schedule Name
Field: Generic Contaminant Control Availability Schedule Name
Field: Generic Contaminant Setpoint Schedule Name
ZoneControl Contaminant Controller Outputs
Zone Air CO2 Predicted Load to Setpoint Mass Flow Rate [kg/s]
Zone Air CO2 Setpoint Concentration [ppm]
Zone Generic Air Contaminant Predicted Load to Setpoint Mass Flow Rate [kg/s]
Zone Generic Air Contaminant Setpoint Concentration [ppm]
Group – Air Path
AirLoopHVAC:SupplyPath, AirLoopHVAC:ReturnPath
AirLoopHVAC:SupplyPath
Field: Name
Field: Supply Air Path Inlet Node Name
Field Set Component Type and Name
Field: Component <#> Object Type
Field: Component <#> Name
AirLoopHVAC:ReturnPath
Field: Name
Field: Return Air Path Outlet Node Name
Field Set Component Type and Name
Field: Component <#> Object Type
Field: Component <#> Name
AirLoopHVAC:ReturnPlenum
Field: Name
Field: Zone Name
Field: Zone Node Name
Field: Outlet Node Name
Field: Induced Air Outlet Node or NodeList Name
Field: Inlet <#> Node Name
AirLoopHVAC:SupplyPlenum
Field: Name
Field: Zone Name
Field: Zone Node Name
Field: Inlet Node Name
Field: Outlet <#> Node Name
AirLoopHVAC:ZoneSplitter
Field: Name
Field: Inlet Node Name
Field: Outlet <#> Node Name
AirLoopHVAC:ZoneMixer
Field: Name
Field: Outlet Node Name
Field: Inlet <#> Node Name
Group – Non-Zone Equipment
LoadProfile:Plant
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Load Schedule Name
Field: Peak Flow Rate
Field: Flow Rate Fraction Schedule Name
LoadProfile Plant Outputs
Plant Load Profile Mass Flow Rate [kg/s]
Plant Load Profile Heat Transfer Rate [W]
Plant Load Profile Heat Transfer Energy [J]
Plant Load Profile Cooling Energy [J]Plant Load Profile Heating Energy [J]
Group – Solar Collectors
SolarCollector:FlatPlate:Water
Field: Name
Field: Solar Collector Performance Name
Field: Surface Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Maximum Flow Rate
Solar Collector FlatPlate Water Output
Solar Collector Incident Angle Modifier [ ]
Solar Collector Efficiency [ ]
Solar Collector Heat Transfer Rate [W]
Solar Collector Heat Transfer Energy [J]
Solar Collector Heat Gain Rate [W]
Solar Collector Heat Loss Rate [W]
SolarCollectorPerformance:FlatPlate
Field: Name
Field: Gross Area
Field: Test Fluid
Field: Test Flow Rate
Field: Test Correlation Type
Field: Coefficient 1 of Efficiency Equation
Field: Coefficient 2 of Efficiency Equation
Field: Coefficient 3 of Efficiency Equation
Field: Coefficient 2 of Incident Angle Modifier
Field: Coefficient 3 of Incident Angle Modifier
SolarCollectorPerformance:FlatPlate Output
SolarCollector:IntegralCollectorStorage
Field: Name
Field: Solar Collector Performance Name
Field: Surface Name
Field: Bottom surface Boundary Conditions Type
Field: Other Side Conditions Model Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Maximum Flow Rate
SolarCollectorPerformance:IntegralCollectorStorage
Field: Name
Field: ICS Collector Type
Field: Gross Area
Field: Collector Water Volume
Field: Bottom Heat Loss Conductance
Field: Side Heat Loss Conductance
Field: Collector Aspect Ratio
Field: Collector Side Height
Field: Thermal Mass of Absorber Plate
Field: Number of Covers
Field: Cover Spacing
Field: Refractive Index of Outer Cover
Field: Extinction Coefficient Times Thickness of Outer Cover
Field: Emissivity of Outer Cover
Field: Refractive Index of Inner Cover
Field: Extinction Coefficient Times Thickness of Inner Cover
Field: Emissivity of Inner Cover
Field: Absorptance of Absorber Plate
Field: Emissivity of Absorber Plate
Solar Collector Integral Collector Storage Outputs
Solar Collector Storage Water Temperature [C]
Solar Collector Absorber Plate Temperature [C]
Solar Collector Thermal Efficiency [ ]
Solar Collector Storage Heat Transfer Rate [W]
Solar Collector Storage Heat Transfer Energy [J]
Solar Collector Skin Heat Transfer Rate [W]
Solar Collector Skin Heat Transfer Energy [J]
Solar Collector Heat Transfer Rate [W]
Solar Collector Heat Transfer Energy [J]
Solar Collector Transmittance Absorptance Product [ ]
Solar Collector Overall Top Heat Loss Coefficient [W/m2-C]
SolarCollector:FlatPlate:PhotovoltaicThermal
Field: Name
Field: Surface Name
Field: Photovoltaic-Thermal Model Performance Name
Field: Photovoltaic Generator Name
Field: Thermal Working Fluid Type
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Design Flow Rate
Solar Collector FlatPlate PhotovoltaicThermal Outputs
Generator Produced Thermal Rate [W]
Generator Produced Thermal Energy [J]
Generator PVT Fluid Bypass Status [ ]
Generator PVT Fluid Inlet Temperature [C]
Generator PVT Fluid Outlet Temperature [C]
Generator PVT Fluid Mass Flow Rate [kg/s]
SolarCollectorPerformance:PhotovoltaicThermal:Simple
Field: Name
Field: Fraction of Surface Area with Active Thermal Collector
Field: Thermal Conversion Efficiency Input Mode Type
Field: Value for Thermal Conversion Efficiency if Fixed
Field: Name of Schedule for Thermal Conversion Efficiency
Field: Front Surface Emittance
Solar Collector Heating System Plant Connections
Solar Heating System Control
Freeze Prevention
Additional Controls
System Availability Manager List Example
SolarCollector:UnglazedTranspired
Field: Name
Field: Boundary Conditions Model Name
Field: Availability Schedule Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Setpoint Node Name
Field: Zone Node Name
Field: Free Heating Setpoint Schedule Name
Field: Diameter of Perforations in Collector
Field: Distance Between Perforations in Collector
Field: Thermal Emissivity of Collector Surface
Field: Solar Absorbtivity of Collector Surface
Field: Effective Overall Height of Collector
Field: Effective Gap Thickness of Plenum Behind Collector
Field: Effective Cross Section Area of Plenum Behind Collector
Field: Hole Layout Pattern for Pitch
Field: Heat Exchange Effectiveness Correlation
Field: Ratio of Actual Collector Surface Area to Projected Surface Area
Field: Roughness of Collector
Field: Collector Thickness
Field: Effectiveness for Perforations with Respect to Wind
Field: Discharge Coefficient for Openings with Respect to Buoyancy Driven Flow
Field: Surface <#> Name
Solar Collector Unglazed Transpired Outputs
Solar Collector Heat Exchanger Effectiveness []
Solar Collector Leaving Air Temperature [C]
Solar Collector Outside Face Suction Velocity [m/s]
Solar Collector Surface Temperature [C]
Solar Collector Plenum Air Temperature [C]
Solar Collector Sensible Heating Rate [W]
SolarAir:Facility [J]
SolarAir:HVAC [J]
HeatProduced:SolarAir [J]
Solar Collector Sensible Heating Energy [J]
Solar Collector Natural Ventilation Air Change Rate [ACH]
Solar Collector Natural Ventilation Mass Flow Rate [kg/s]
Solar Collector Wind Natural Ventilation Mass Flow Rate [kg/s]
Solar Collector Buoyancy Natural Ventilation Mass Flow Rate [kg/s]
Solar Collector Incident Solar Radiation [W/m2]
Solar Collector System Efficiency []
Solar Collector Surface Efficiency []
SolarCollector:UnglazedTranspired:MultiSystem
Field: Solar Collector Name
Field Set: Inlet Node, Outlet Node, Mixed Air Node, Zone Node
Field: Outdoor Air System <#> Collector Inlet Node
Field: Outdoor Air System <#> Collector Outlet Node
Field: Outdoor Air System <#> Mixed Air Node
Field: Outdoor Air System <#> Zone Node
Group – Pumps
Pump:VariableSpeed
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Rated Flow Rate
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Coefficient 1 of the Part Load Performance Curve
Field: Coefficient 2 of the Part Load Performance Curve
Field: Coefficient 3 of the Part Load Performance Curve
Field: Coefficient 4 of the Part Load Performance Curve
Field: Minimum Flow Rate
Field: Pump Control Type
Field: Pump Flow Rate Schedule Name
Field: Pump Curve Name
Field: Impeller Diameter
Field: VFD Control Type
Field: Pump RPM Schedule Name
Field: Minimum Pressure Schedule
Field: Maximum Pressure Schedule
Field: Minimum RPM Schedule
Field: Maximum RPM Schedule
Field: Zone Name
Field: Skin Loss Radiative Fraction
Variable Speed Pump Outputs
Pump Electric Power [W]
Pump Electric Energy [J]
Pump Shaft Power [W]
Pump Fluid Heat Gain Rate [W]
Pump Fluid Heat Gain Energy [J]
Pump Outlet Temperature [C]
Pump Mass Flow Rate [kg/s]
Pump Zone Total Heating Rate [W]
Pump Zone Total Heating Energy [J]
Pump Zone Convective Heating Rate [W]
Pump Zone Radiative Heating Rate [W]
Pump:ConstantSpeed
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Rated Flow Rate
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Pump Control Type
Field: Pump Flow Rate Schedule Name
Field: Pump Curve Name
Field: Impeller Diameter
Field: Rotational Speed
Field: Zone Name
Field: Skin Loss Radiative Fraction
Constant Speed Pump Outputs
Pump Electric Power [W]
Pump Electric Energy [J]
Pump Shaft Power [W]
Pump Fluid Heat Gain Rate [W]
Pump Fluid Heat Gain Energy [J]
Pump Outlet Temperature [C]
Pump Mass Flow Rate [kg/s]
Pump Zone Convective Heating Rate [W]
Pump Zone Radiative Heating Rate [W]
Pump Zone Total Heating Energy [J]
Pump Zone Total Heating Rate [W]
Pump:VariableSpeed:Condensate
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Rated Flow Rate
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Coefficient 1 of the Part Load Performance Curve
Field: Coefficient 2 of the Part Load Performance Curve
Field: Coefficient 3 of the Part Load Performance Curve
Field: Coefficient 4 of the Part Load Performance Curve
Field: Pump Flow Rate Schedule Name
Field: Zone Name
Field: Skin Loss Radiative Fraction
Variable Speed Condensate Pump Outputs
Pump Electric Power [W]
Pump Electric Energy [J]
Pump Shaft Power [W]
Pump Fluid Heat Gain Rate [W]
Pump Fluid Heat Gain Energy [J]
Pump Outlet Temperature [C]
Pump Mass Flow Rate [kg/s]
Pump Zone Total Heating Rate [W]
Pump Zone Total Heating Energy [J]
Pump Zone Convective Heating Rate [W]
Pump Zone Radiative Heating Rate [W]
HeaderedPumps:ConstantSpeed
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Total Rated Flow Rate
Field: Number of Pumps in Bank
Field: Flow Sequencing Control Scheme
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Pump Control Type
Field: Pump Flow Rate Schedule Name
Field: Zone Name
Field: Skin Loss Radiative Fraction
Constant Speed Headered Pumps Outputs
Pump Electric Power [W]
Pump Electric Energy [J]
Pump Shaft Power [W]
Pump Fluid Heat Gain Rate [W]
Pump Fluid Heat Gain Energy [J]
Pump Outlet Temperature [C]
Pump Mass Flow Rate [kg/s]
Pump Operating Pumps Count []
Pump Zone Total Heating Rate [ W]“pump-zone-total-heating-energy-j-3
Pump Zone Convective Heating Rate [W]
Pump Zone Radiative Heating Rate [W]
HeaderedPumps:VariableSpeed
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Total Rated Flow Rate
Field: Number of Pumps in Bank
Field: Flow Sequencing Control Scheme
Field: Rated Pump Head
Field: Rated Power Consumption
Field: Motor Efficiency
Field: Fraction of Motor Inefficiencies to Fluid Stream
Field: Coefficient 1 of the Part Load Performance Curve
Field: Coefficient 2 of the Part Load Performance Curve
Field: Coefficient 3 of the Part Load Performance Curve
Field: Coefficient 4 of the Part Load Performance Curve
Field: Minimum Flow Rate
Field: Pump Control Type
Field: Pump Flow Rate Schedule Name
Field: Zone Name
Field: Skin Loss Radiative Fraction
Variable Speed Headered Pumps Outputs
Pump Electric Power [W]
Pump Electric Energy [J]
Pump Shaft Power [W]
Pump Fluid Heat Gain Rate [W]
Pump Fluid Heat Gain Energy [J]
Pump Outlet Temperature [C]
Pump Mass Flow Rate [kg/s]
Pump Operating Pumps Count []
Pump Zone Total Heating Rate [W]
Pump Zone Total Heating Energy [J]
Pump Zone Convective Heating Rate [W]
Pump Zone Radiative Heating Rate [W]
Group – Heating and Cooling Coils
Coil:Cooling:Water
Field: Name
Field: Availability Schedule Name
Field: Design Water Flow Rate
Field: Design Air Flow Rate
Field: Design Inlet Water Temperature
Field: Design Inlet Air Temperature
Field: Design Outlet Air Temperature
Field: Design Inlet Air Humidity Ratio
Field: Design Outlet Air Humidity Ratio
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Type of Analysis
Field: Heat Exchanger Configuration
Field: Condensate Collection Water Storage Tank Name
Cooling Coil (Water) Outputs
Cooling Coil Total Cooling Energy (J)
Cooling Coil Sensible Cooling Energy (J)
Cooling Coil Total Cooling Rate (W)
Cooling Coil Sensible Cooling Rate (W)
Cooling Coil Wetted Area Fraction []
Cooling Coil Condensate Volume Flow Rate [m3/s]
Cooling Coil Condensate Volume [m3]
Cooling Coil Source Side Heat Transfer Energy [J]
Coil:Heating:Water
Field: Name
Field: Availability Schedule Name
Field: U-Factor Times Area Value
Field: Maximum Water Flow Rate
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Performance Input Method
Field: Rated Capacity
Field: Rated Inlet Water Temperature
Field: Rated Inlet Air Temperature
Field: Rated Outlet Water Temperature
Field: Rated Outlet Air Temperature
Field: Rated Ratio for Air and Water Convection
Heating Coil (Water) Outputs
Heating Coil Heating Energy [J]
Heating Coil Heating Rate [W]
Heating Coil U Factor Times Area Value [W/K]
Heating Coil Source Side Heat Transfer Energy [J]
Coil:Heating:Steam
Field: Name
Field: Availability Schedule Name
Field: Maximum Steam Flow Rate
Field: Degree of SubCooling
Field: Degree of Loop SubCooling
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Coil Control Type
Field: Temperature Setpoint Node Name
Heating Coil (Steam) Outputs:
Heating Coil Heating Energy [J]
Heating Coil Heating Rate [W]
Heating Coil Steam Trap Loss Rate [W]
Heating Coil Steam Inlet Temperature [C]
Heating Coil Steam Outlet Temperature [C]
Heating Coil Steam Mass Flow Rate [kg/s]
Coil:Heating:Electric
Field: Name
Field: Availability Schedule Name
Field: Efficiency
Field: Nominal Capacity
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Temperature Setpoint Node Name
Heating Coil (Electric) Outputs
Heating Coil Air Heating Energy (J)
Heating Coil Air Heating Rate [W]
Heating Coil Electric Energy [J]
Heating Coil Electric Power [W]
Coil:Heating:Electric:MultiStage
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Temperature Setpoint Node Name
Field: Stage 1 Efficiency
Field: Stage 1 Nominal Capacity
Field: Stage 2 Efficiency
Field: Stage 2 Nominal Capacity
Field: Stage 3 Efficiency
Field: Stage 3 Nominal Capacity
Field: Stage 4 Efficiency
Field: Stage 4 Nominal Capacity
Heating Coild (Electric Multistage) Outputs
Heating Coil Energy (J)
Heating Coil Rate[W]
Heating Coil Electric Consumption [J]
Heating Coil Electric Power [W]
Coil:Heating:Desuperheater
Field: Name
Field: Availability Schedule Name
Field: Heat Reclaim Recovery Efficiency
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Heating Source Object Type
Field: Heating Source Name
Field: Temperature Setpoint Node Name
Field: Parasitic Electric Load
Heating Coil (Desuperheater) Outputs
Heating Coil Air Heating Rate [W]
Heating Coil Air Heating Energy [J]
Heating Coil Electric Power [W]
Heating Coil Electric Energy [J]
Heating Coil Runtime Fraction []
Coil:Cooling:DX:VariableRefrigerantFlow
Field: Coil Name
Field: Availability Schedule Name
Field: Rated Total Cooling Capacity
Field: Ratio Sensible Heat Ratio
Field: Rated Air Flow Rate
Field: Cooling Capacity Ratio Modifier Function of Temperature Curve Name
Field: Cooling Capacity Modifier Curve Function of Flow Fraction Name
Field: Coil Air Inlet Node Name
Field: Coil Air Outlet Node Name
Field: Name of Water Storage Tank for Condensate Collection
Cooling DX Coil (VariableRefrigerantFlow) Outputs
Cooling Coil Total Cooling Rate [W]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Sensible Cooling Energy [J]
Cooling Coil Latent Cooling Rate [W]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Runtime Fraction []
Cooling Coil Condensate Volume Flow Rate [m3/s]
Cooling Coil Condensate Volume [m3]
Coil:Heating:DX:VariableRefrigerantFlow
Field: Name
Field: Availability Schedule Name
Field: Rated Total Heating Capacity
Field: Rated Air Flow Rate
Field: Coil Air Inlet Node
Field: Coil Air Outlet Node
Field: Heating Capacity Ratio Modifier Function of Temperature Curve Name
Field: Heating Capacity Ratio Modifier Function of Flow Fraction Curve Name
Heating DX Coil (VariableRefrigerantFlow) Outputs
Heating Coil Total Heating Rate [W]
Heating Coil Total Heating Energy [J]
Heating Coil Runtime Fraction []
Coil:Heating:Gas
Field: Name
Field: Availability Schedule Name
Field: Gas Burner Efficiency
Field: Nominal Capacity
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Temperature Setpoint Node Name
Field: Parasitic Electric Load
Field: Part Load Fraction Correlation Curve Name
Field: Parasitic Gas Load
Heating Coil (Gas) Outputs
Heating Coil Air Heating Energy [J]
Heating Coil Air Heating Rate [W]
Heating Coil Gas Energy [J]
Heating Coil Gas Rate [W]
Heating Coil Electric Energy [J]
Heating Coil Electric Power [W]
Heating Coil Runtime Fraction []
Heating Coil Ancillary Gas Energy [J]
Heating Coil Ancillary Gas Rate [W]
Coil:Heating:Gas:MultiStage
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Temperature Setpoint Node Name
Field: Part Load Fraction Correlation Curve Name
Field: Parasitic Gas Load
Field: Stage 1 Gas Burner Efficiency
Field: Stage 1 Nominal Capacity
Field: Stage 1 Parasitic Electric Load
Field: Stage 2 Gas Burner Efficiency
Field: Stage 2 Nominal Capacity
Field: Stage 2 Parasitic Electric Load
Field: Stage 3 Gas Burner Efficiency
Field: Stage 3 Nominal Capacity
Field: Stage 3 Parasitic Electric Load
Field: Stage 4 Gas Burner Efficiency
Field: Stage 4 Nominal Capacity
Field: Stage 4 Parasitic Electric Load
Heating Coil (Gas Multistage) Outputs
Heating Coil Energy [J]
Heating Coil Rate [W]
Heating Coil Gas Consumption [J]
Heating Coil Gas Consumption Rate [W]
Heating Coil Electric Consumption [J]
Heating Coil Electric Power [W]
Heating Coil Parasitic Gas Consumption [J]
Heating Coil Parasitic Gas Consumption Rate [W]
Coil:Cooling:Water:DetailedGeometry
Field: Name
Field: Availability Schedule Name
Field: Maximum Water Flow Rate
Field: Tube Outside Surface Area
Field: Total Tube Inside Area
Field: Fin Surface Area
Field: Minimum Air Flow Area
Field: Coil Depth
Field: Fin Diameter
Field: Fin Thickness
Field: Tube Inside Diameter
Field: Tube Outside Diameter
Field: Tube Thermal Conductivity
Field: Fin Thermal Conductivity
Field: Fin Spacing
Field: Tube Depth Spacing
Field: Number of Tube Rows
Field: Number of Tubes per Row
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Condensate Collection Water Storage Tank Name
Detailed Geometry Cooling Coil (Water) Outputs
Cooling Coil Total Cooling Energy (J)
Cooling Coil Sensible Cooling Energy (J)
Cooling Coil Total Cooling Rate (W)
Cooling Coil Sensible Cooling Rate (W)
Cooling Coil Condensate Volume Flow Rate [m3/s]
Cooling Coil Condensate Volume [m3]
Cooling Coil Source Side Heat Transfer Energy [J]
Coil:Cooling:DX:SingleSpeed
Field: Name
Field: Availability Schedule Name
Field: Rated Total Cooling Capacity
Field: Rated Sensible Heat Ratio
Field: Rated COP
Field: Rated Air Flow Rate
Field: Rated Evaporator Fan Power Per Volume Flow Rate
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Total Cooling Capacity Function of Temperature Curve Name
Field: Total Cooling Capacity Function of Flow Fraction Curve Name
Field: Energy Input Ratio Function of Temperature Curve Name
Field: Energy Input Ratio Function of Flow Fraction Curve Name
Field: Part Load Fraction Correlation Curve Name
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: Maximum Cycling Rate
Field: Latent Capacity Time Constant
Field: Condenser Air Inlet Node Name
Field: Condenser Type
Field: Evaporative Condenser Effectiveness
Field: Evaporative Condenser Air Flow Rate
Field: Evaporative Condenser Pump Rated Power Consumption
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Supply Water Storage Tank Name
Field: Condensate Collection Water Storage Tank Name
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Sensible Heat Ratio Function of Temperature Curve Name
Field: Sensible Heat Ratio Function of Flow Fraction Curve Name
Coil:Cooling:DX:TwoSpeed
Field: Name
Field: Availability Schedule Name
Field: Rated High Speed Total Cooling Capacity
Field: Rated High Speed Sensible Heat Ratio
Field: Rated High Speed COP
Field: Rated High Speed Air Flow Rate
Field: Unit Internal Static Air Pressure
Field: Air Inlet Node
Field: Air Outlet Node
Field: Total Cooling Capacity Function of Temperature Curve Name
Field: Total Cooling Capacity Function of Flow Fraction Curve Name
Field: Energy Input Ratio Function of Temperature Curve Name
Field: Energy Input Ratio Function of Flow Fraction Curve Name
Field: Part Load Fraction Correlation Curve Name
Field: Rated Low Speed Total Cooling Capacity
Field: Rated Low Speed Sensible Heat Ratio
Field: Rated Low Speed COP
Field: Rated Low Speed Air Flow Rate
Field: Low Speed Total Cooling Capacity Function of Temperature Curve Name
Field: Low Speed Energy Input Ratio Function of Temperature Curve Name
Field: Condenser Air Inlet Node Name
Field: Condenser Type
Field: High Speed Evaporative Condenser Effectiveness
Field: High Speed Evaporative Condenser Air Flow Rate
Field: High Speed Evaporative Condenser Pump Rated Power Consumption
Field: Low Speed Evaporative Condenser Effectiveness
Field: Low Speed Evaporative Condenser Air Flow Rate
Field: Low Speed Evaporative Condenser Pump Rated Power Consumption
Field: Supply Water Storage Tank Name
Field: Condensate Collection Water Storage Tank Name
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Sensible Heat Ratio Function of Temperature Curve Name
Field: Sensible Heat Ratio Function of Flow Fraction Curve Name
Field: Low Sensible Heat Ratio Function of Temperature Curve Name
Field: Low Sensible Heat Ratio Function of Flow Fraction Curve Name
Coil:Cooling:DX:TwoStageWithHumidityControlMode
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Number of Capacity Stages
Field: Number of Enhanced Dehumidification Modes
Field: Normal Mode Stage 1 Coil Performance Object Type
Field: Normal Mode Stage 1 Coil Performance Object Name
Field: Normal Mode Stage 1+2 Coil Performance Object Type
Field: Normal Mode Stage 1+2 Coil Performance Object Name
Field: Dehumidification Mode 1 Stage 1 Coil Performance Object Type
Field: Dehumidification Mode 1 Stage 1 Coil Performance Object Name
Field: Dehumidification Mode 1 Stage 1+2 Coil Performance Object Type
Field: Dehumidification Mode 1 Stage 1+2 Coil Performance Object Name
Field: Supply Water Storage Tank Name
Field: Condensate Collection Water Storage Tank Name
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Coil:Cooling:DX:MultiSpeed
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Condenser Air Inlet Node Name
Field: Condenser Type
The type of condenser used by the multispeed DX cooling coil. Valid choices for this input field are AirCooled or EvaporativelyCooled. The default for this field is AirCooled.
Field: Supply Water Storage Tank Name
Field: Condensate Collection Water Storage Tank Name
Field: Apply Part Load Fraction to Speeds Greater than 1
Field: Apply Latent Degradation to Speeds Greater than 1
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field: Fuel Type
Field: Number of Speeds
Field Group: rated specification, performance curves, latent capacity degradation inputs, and evaporative cooled condenser data
Field: Speed Rated Total Cooling Capacity
Field: Speed Rated Sensible Heat Ratio
Field: Speed Rated COP
Field: Speed Rated Air Flow Rate
Field: Speed Total Cooling Capacity Function of Temperature Curve Name
Field: Speed Total Cooling Capacity Function of Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Flow Fraction Curve Name
Field: Speed Part Load Fraction Correlation Curve Name
Field: Speed Nominal Time for Condensate Removal to Begin
Field: Speed Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: Speed Maximum Cycling Rate
Field: Speed Latent Capacity Time Constant
Field: Speed Rated Waste Heat Fraction of Power Input
Field: Speed Waste Heat Function of Temperature Curve Name
Field: Speed Evaporative Condenser Effectiveness
Field: Speed Evaporative Condenser Air Flow Rate
Field: Speed Rated Evaporative Condenser Pump Power Consumption
DX Cooling Coil Outputs
Cooling Coil Total Cooling Rate [W]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Sensible Cooling Energy [J]
Cooling Coil Latent Cooling Rate [W]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Electric Power [W]
Cooling Coil Electric Energy [J]
Cooling Coil Runtime Fraction []
Cooling Coil Crankcase Heater Electric Power[W]
Cooling Coil Crankcase Heater Electric Energy [J]
Cooling Coil Condenser Inlet Temperature [C]
Cooling Coil Evaporative Condenser Water Volume [m3]
Cooling Coil Evaporative Condenser Mains Supply Water Volume [m3]
Cooling Coil Evaporative Condenser Pump Electric Power [W]
Cooling Coil Evaporative Condenser Pump Electric Energy [J]
Cooling Coil Stage 2 Runtime Fraction []
Cooling Coil Dehumidification Mode []
Cooling Coil Condensate Volume Flow Rate [m3/s]
Cooling Coil Condensate Volume [m3]
Cooling Coil Evaporative Condenser Mains Supply Water Volume [m3]
Cooling Coil Basin Heater Electric Power [W]
Cooling Coil Basin Heater Electric Energy [J]
Cooling Coil Power [W]
Cooling Coil Energy [J]
Coil:Cooling:DX:VariableSpeed
Field: Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Number of Speeds
Field: Nominal Speed Level
Field: Rated Total Cooling Capacity at Selected Nominal Speed Level
Field: Rated Volumetric Air Flow Rate at Selected Nominal Speed Level
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: Part Load Fraction Correlation Curve Name
Field: Condenser Air Inlet Node Name
Field: Condenser Type
Field: Evaporative Condenser Pump Rated Power Consumption
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Supply Water Storage Tank Name
Field: Condensate Collection Water Storage Tank Name
Field: Basin Heater Capacity
Field: Basin Heater Setpoint Temperature
Field: Basin Heater Operating Schedule Name
Field Group: Rated specification, performance curves
Field: Speed Reference Unit Total Cooling Capacity
Field: Speed Reference Unit SHR
Field: Speed Reference Unit COP
Field: Speed Reference Unit Air Flow Rate
Field: Speed Reference Unit Condenser Flow Rate
Field: Speed Reference Unit Pad Effectiveness of Evap Precooling
Field: Speed Total Cooling Capacity Function of Temperature Curve Name
Field: Speed Total Cooling Capacity Function of Air Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Air Flow Fraction Curve Name
Variable Speed DX Cooling Coil Outputs
Cooling Coil Electric Power [W]
Cooling Coil Total Cooling Rate [W]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Rate [W]
Cooling Coil Part Load Ratio []
Cooling Coil Runtime Fraction []
Cooling Coil Air Mass Flow Rate [kg/s]
Cooling Coil Air Inlet Temperature [C]
Cooling Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Air Outlet Temperature [C]
Cooling Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Upper Speed Level []
Cooling Coil Neighboring Speed Levels Ratio []
Cooling Coil Electric Energy [J]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Energy [J]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Latent Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Energy [J]
Cooling Coil Crankcase Heater Electric Power [W]
Cooling Coil Crankcase Heater Electric Energy [J]
Cooling Coil Condensate Volume Flow Rate [m3/s]
Cooling Coil Condensate Volume [m3]
Cooling Coil Condenser Inlet Temperature [C]
Cooling Coil Evaporative Condenser Water Volume [m3]
Cooling Coil Evaporative Condenser Mains Water Volume [m3]
Cooling Coil Evaporative Condenser Pump Electric Power[W]
Cooling Coil Evaporative Condenser Pump Electric Energy [J]
Cooling Coil Basin Heater Electric Power [W]
Cooling Coil Basin Heater Electric Energy [J]
CoilPerformance:DX:Cooling
Field: Name
Field: Rated Total Cooling Capacity
Field: Rated Sensible Heat Ratio
Field: Rated COP
Field: Rated Air Flow Rate
Field: Fraction of Air Flow Bypassed Around Coil
Field: Total Cooling Capacity Function of Temperature Curve Name
Field: Total Cooling Capacity Function of Flow Fraction Curve Name
Field: Energy Input Ratio Function of Temperature Curve Name
Field: Energy Input Ratio Function of Flow Fraction Curve Name
Field: Part Load Fraction Correlation Curve Name
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: Maximum Cycling Rate
Field: Latent Capacity Time Constant
Field: Condenser Air Inlet Node Name
Field: Condenser Type
Field: Evaporative Condenser Effectiveness
Field: Evaporative Condenser Air Flow Rate
Field: Evaporative Condenser Pump Rated Power Consumption
Field: Sensible Heat Ratio Function of Temperature Curve Name
Field: Sensible Heat Ratio Function of Flow Fraction Curve Name
Coil Performance DX Cooling Outputs
Coil:Heating:DX:SingleSpeed
Field: Name
Field: Availability Schedule Name
Field: Rated Total Heating Capacity
Field: Rated COP
Field: Rated Air Flow Rate
Field: Rated Evaporator Fan Power Per Volume Flow Rate
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Total Heating Capacity Function of Temperature Curve Name
Field: Total Heating Capacity Function of Flow Fraction Curve Name
Field: Energy Input Ratio Function of Temperature Curve Name
Field: Energy Input Ratio Function of Flow Fraction Curve Name
Field: Part Load Fraction Correlation Curve Name
Field: Defrost Energy Input Ratio Function of Temperature Curve Name
Field: Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
Field: Outdoor Dry-Bulb Temperature to Turn On Compressor
Field: Maximum Outdoor Dry-Bulb Temperature for Defrost Operation
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Defrost Strategy
Field: Defrost Control
Field: Defrost Time Period Fraction
Field: Resistive Defrost Heater Capacity
Field: Region Number
Field: Evaporator Air Inlet Node Name
DX Heating Coil Outputs
Heating Coil Total Heating Rate [W]
Heating Coil Total Heating Energy [J]
Heating Coil Electric Power [W]
Heating Coil Electric Energy [J]
Heating Coil Defrost Electric Power [W]
Heating Coil Defrost Electric Energy [J]
Heating Coil Crankcase Heater Electric Power [W]
Heating Coil Crankcase Heater Electric Energy [J]
Heating Coil Runtime Fraction []
Coil:Heating:DX:MultiSpeed
Field: Name
Field: Availability Schedule Name
Field: Air Inlet Node name
Field: Air Outlet Node Name
Field: Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Defrost Energy Input Ratio Function of Temperature Curve Name
Field: Maximum Outdoor Dry-Bulb Temperature for Defrost Operation
Field: Defrost Strategy
Field: Defrost Control
Field: Defrost Time Period Fraction
Field: Resistive Defrost Heater Capacity
Field: Apply Part Load Fraction to Speeds Greater than 1
Field: Fuel Type
Field: Number of Speeds
Field Group: rated specification, performance curves, and waste heat data
Field: Speed Rated Total Heating Capacity
Field: Speed Rated COP
Field: Speed Rated Air Flow Rate
Field: Speed Total Heating Capacity Function of Temperature Curve Name
Field: Speed Total Heating Capacity Function of Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Flow Fraction Curve Name
Field: Speed Part Load Fraction Correlation Curve Name
Field: Speed Rated Waste Heat Fraction of Power Input
Field: Speed Waste Heat Function of Temperature Curve Name
MultiSpeed DX Heating Coil Outputs
Heating Coil Total Heating Rate [W]
Heating Coil Total Heating Energy [J]
Heating Coil Electric Power [W]
Cooling Coil Electric Energy [J]
Heating Coil Defrost Electric Power [W]
Heating Coil Defrost Electric Energy [J]
Heating Coil Defrost Rate [W]
Heating Coil Defrost Energy [J]
Heating Coil Crankcase Heater Electric Power [W]
Heating Coil Crankcase Heater Electric Energy [J]
Heating Coil Runtime Fraction []
Heating Coil Rate [W]
Cooling Coil Energy [J]
Coil:Heating:DX:VariableSpeed
Field: Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Number of Speeds
Field: Nominal Speed Level
Field: Rated Total Heating Capacity at Selected Nominal Speed Level
Field: Rated Volumetric Air Flow Rate
!!! {:error “Image in Header” :alt “” :img “media/image339.png”} !!!
Field: Part Load Fraction Correlation Curve Name
Field: Defrost Energy Input Ratio Function of Temperature Curve Name
Field: Minimum Outdoor Dry-Bulb Temperature for Compressor Operation
Field: Outdoor Dry-Bulb Temperature to Turn On Compressor
Field: Maximum Outdoor Dry-Bulb Temperature for Defrost Operation
Field: Crankcase Heater Capacity
Field: Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation
Field: Defrost Strategy
Field: Defrost Control
Field: Defrost Time Period Fraction
Field: Resistive Defrost Heater Capacity
Field Group: Rated specification and performance curves
Field: Speed Reference Unit Total Heating Capacity
Field: Speed Reference Unit COP
Field: Speed Reference Unit Volumetric Air Flow Rate
Field: Speed Total Heating Capacity Function of Temperature Curve Name
Field: Speed Total Heating Capacity Function of Air Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Air Flow Fraction Curve Name
Variable Speed DX Heating Coil Outputs
Heating Coil Electric Power [W]
Heating Coil Heating Rate [W]
Heating Coil Sensible Heating Rate [W]
Heating Coil Source Side Heat Transfer Rate [W]
Heating Coil Part Load Ratio []
Heating Coil Runtime Fraction []
Heating Coil Air Mass Flow Rate [kg/s]
Heating Coil Air Inlet Temperature [C]
Heating Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Air Outlet Temperature [C]
Heating Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Upper Speed Level []
Heating Coil Neighboring Speed Levels Ratio []
Heating Coil Electric Energy [J]
Heating Coil Heating Energy [J]
Heating Coil Source Side Heat Transfer Energy [J]
Heating Coil Defrost Electric Power[W]
Heating Coil Defrost Electric Energy [J]
Heating Coil Crankcase Heater Electric Power [W]
Heating Coil Crankcase Heater Electric Energy [J]
Coil:WaterHeating:Desuperheater
Field: Name
Field: Availability Schedule Name
Field: Setpoint Temperature Schedule Name
Field: Dead Band Temperature Difference
Field: Rated Heat Reclaim Recovery Efficiency
Field: Rated Inlet Water Temperature
Field: Rated Outdoor Air Temperature
Field: Maximum Inlet Water Temperature for Heat Reclaim
Field: Heat Reclaim Efficiency Function of Temperature Curve Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Tank Object Type
Field: Tank Name
Field: Heating Source Object Type
Field: Heating Source Name
Field: Water Flow Rate
Field: Water Pump Power
Field: Fraction of Pump Heat to Water
Field: On-Cycle Parasitic Electric Load
Field: Off-Cycle Parasitic Electric Load
WaterHeating Coil (Desuperheater) Outputs
Water Heater Heating Rate [W]
Water Heater Heating Energy [J]
Water Heater Pump Electric Power [W]
Water Heater Pump Electric Energy [J]
Water Heater Heat Reclaim Efficiency Modifier Multiplier []
Water Heater On Cycle Parasitic Electric Power [W]
Water Heater On Cycle Parasitic Electric Energy [J]
Water Heater Off Cycle Parasitic Electric Power [W]
Water Heater Off Cycle Parasitic Electric Energy [J]
CoilSystem:Cooling:DX
Field: Name
Field: Availability Schedule Name
Field: DX Cooling Coil System Inlet Node Name
Field: DX Cooling Coil System Outlet Node Name
Field: DX Cooling Coil System Sensor Node Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
Field: Dehumidification Control Type
Field: Run on Sensible Load
Field: Run on Latent Load
Field: Use Outdoor Air DX Cooling Coil
Field: Outdoor Air DX Cooling Coil Leaving Minimum Air Temperature
DX Cooling Coil System Outputs
Coil System Cycling Ratio
Coil System Compressor Speed Ratio
Coil System Part Load Ratio
Coil System Frost Control Status
CoilSystem:Heating:DX
Field: Name
Field: Availability Schedule Name
Field: Heating Coil Object Type
Field: Heating Coil Name
DX Heating Coil System Outputs
Coil System Part Load Ratio
CoilSystem:Cooling:DX:HeatExchangerAssisted
Field: Name
Field: Heat Exchanger Object Type
Field: Heat Exchanger Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
CoilSystem:Cooling:DX:HeatExchangerAssisted Outputs
CoilSystem:Cooling:Water:HeatExchangerAssisted
Field: Name
Field: Heat Exchanger Object Type
Field: Heat Exchanger Name
Field: Cooling Coil Object Type
Field: Cooling Coil Name
CoilSystem:Cooling:Water:HeatExchangerAssisted Outputs
Coil:WaterHeating:AirToWaterHeatPump
Field: Name
Field: Rated Heating Capacity
Field: Rated COP
Field: Rated Sensible Heat Ratio
Field: Rated Evaporator Inlet Air Dry-Bulb Temperature
Field: Rated Evaporator Inlet Air Wet-Bulb Temperature
Field: Rated Condenser Inlet Water Temperature
Field: Rated Evaporator Air Flow Rate
Field: Rated Condenser Water Flow Rate
Field: Evaporator Fan Power Included in Rated COP
Field: Condenser Pump Power Included in Rated COP
Field: Condenser Pump Heat Included in Rated Heating Capacity and Rated COP
Field: Condenser Water Pump Power
Field: Fraction of Condenser Pump Heat to Water
Field: Evaporator Air Inlet Node Name
Field: Evaporator Air Outlet Node Name
Field: Condenser Water Inlet Node Name
Field: Condenser Water Outlet Node Name
Field: Crankcase Heater Capacity
Field: Maximum Ambient Temperature for Crankcase Heater Operation
Field: Evaporator Air Temperature Type for Curve Objects
Field: Heating Capacity Function of Temperature Curve Name
Field: Heating Capacity Function of Air Flow Fraction Curve Name
Field: Heating Capacity Function of Water Flow Fraction Curve Name
Field: Heating COP Function of Temperature Curve Name
Field: Heating COP Function of Air Flow Fraction Curve Name
Field: Heating COP Function of Water Flow Fraction Curve Name
Field: Part Load Fraction Correlation Curve Name
Coil:WaterHeating:AirToWaterHeatPump Outputs
Cooling Coil Total Cooling Rate [W]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Sensible Cooling Energy [J]
DX Coil Latent Cooling Rate [W]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Runtime Fraction []
Cooling Coil Crankcase Heater Electric Power[W]
Cooling Coil Crankcase Heater Electric Energy [J]
Cooling Coil Total Water Heating Rate [W]
Cooling Coil Total Water Heating Energy [J]
Cooling Coil Water Heating Electric Power[W]
Cooling Coil Water Heating Electric Energy [J]
Coil:Cooling:WaterToAirHeatPump:ParameterEstimation
Field: Name
Field: Compressor Type
Field: Refrigerant Type
Field: Design Source Side Flow Rate
Field: Nominal Cooling Coil Capacity
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: High Pressure Cutoff
Field: Low Pressure Cutoff
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Cooling Coil Parameters
Field: Load Side Total Heat Transfer Coefficient
Field: Load Side Outside Surface Heat Transfer Coefficient
Field: Superheat Temperature at the Evaporator Outlet
Field: Compressor Power Losses
Field: Compressor Efficiency
Field: Compressor Piston Displacement
Field: Compressor Suction/Discharge Pressure Drop
Field: Compressor Clearance Factor
Field: Refrigerant Volume Flow Rate
Field: Volume Ratio
Field: Leak Rate Coefficient
Field: Source Side Heat Transfer Coefficient
Field: Source Side Heat Transfer Resistance1
Field: Source Side Heat Transfer Resistance2
Coil:Cooling:WaterToAirHeatPump:EquationFit
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Rated Air Flow Rate
Field: Rated Water Flow Rate
Field: Rated Total Cooling Capacity
Field: Rated Sensible Cooling Capacity
Field: Rated Cooling Coefficient of Performance
Field: Total Cooling Capacity Coefficient 1 to 5
Field: Sensible Cooling Capacity Coefficient 1 to 6
Field: Cooling Power Consumption Coefficient 1 to 5
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Water to Air Heat Pump Cooling Coil (Parameter Estimation and Equation Fit) Outputs
Cooling Coil Electric Power [W]
Cooling Coil Total Cooling Rate [W]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Rate [W]
Cooling Coil Part Load Ratio []
Cooling Coil Runtime Fraction []
Cooling Coil Air Mass Flow Rate [kg/s]
Cooling Coil Air Inlet Temperature [C]
Cooling Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Air Outlet Temperature [C]
Cooling Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Source Side Mass Flow Rate [kg/s]
Cooling Coil Source Side Inlet Temperature [C]
Cooling Coil Source Side Outlet Temperature [C]
Cooling Coil Electric Energy [J]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Energy [J]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Latent Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Energy [J]
Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Number of Speeds
Field: Nominal Speed Level
Field: Rated Total Cooling Capacity at Selected Nominal Speed Level
Field: Rated Volumetric Air Flow Rate
Field: Rated Volumetric Water Flow Rate
Field: Nominal Time for Condensate Removal to Begin
Field: Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity
Field: Flag for Using Hot Gas Reheat, 0 or 1
Field: Part Load Fraction Correlation Curve Name
Field Group: rated specification, performance curves, and waste heat data
Field: Speed Reference Unit Total Cooling Capacity
Field: Speed Reference Unit SHR
Field: Speed Reference Unit COP
Field: Speed Reference Unit Air Flow Rate
Field: Speed Reference Unit Water Flow Rate
Field: Speed Total Cooling Capacity Function of Temperature Curve Name
Field: Speed Total Cooling Capacity Function of Air Flow Fraction Curve Name
Field: Speed Total Cooling Capacity Function of Water Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Air Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Water Flow Fraction Curve Name
Field: Speed Reference Unit Waste Heat Fraction of Power Input
Field: Speed Waste Heat Function of Temperature Curve Name
Variable Speed Water to Air Heat Pump Cooling Coil Outputs
Cooling Coil Electric Power [W]
Cooling Coil Total Cooling Rate [W]
Cooling Coil Sensible Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Rate [W]
Cooling Coil Part Load Ratio []
Cooling Coil Runtime Fraction []
Cooling Coil Air Mass Flow Rate [kg/s]
Cooling Coil Air Inlet Temperature [C]
Cooling Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Air Outlet Temperature [C]
Cooling Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Cooling Coil Source Side Mass Flow Rate [kg/s]
Cooling Coil Source Side Inlet Temperature [C]
Cooling Coil Source Side Outlet Temperature [C]
Cooling Coil Upper Speed Level []
Cooling Coil Neighboring Speed Levels Ratio []
Cooling Coil Recoverable Heat Transfer Rate [W]
Cooling Coil Electric Energy [J]
Cooling Coil Total Cooling Energy [J]
Cooling Coil Sensible Cooling Energy [J]
Cooling Coil Latent Cooling Energy [J]
Cooling Coil Latent Cooling Rate [W]
Cooling Coil Source Side Heat Transfer Energy [J]
Coil:Heating:WaterToAirHeatPump:ParameterEstimation
Field: Name
Field: Compressor Type
Field: Refrigerant Type
Field: Design Source Side Flow Rate
Field: Nominal Heating Coil Capacity
Field: High Pressure Cutoff
Field: Low Pressure Cutoff
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Heating Coil Parameters
Field: Load Side Total Heat Transfer Coefficient
Field: Superheat Temperature at the Evaporator Outlet
Field: Compressor Power Losses
Field: Compressor Efficiency
Field: Compressor Piston Displacement
Field: Compressor Suction/Discharge Pressure Drop
Field: Compressor Clearance Factor
Field: Refrigerant Volume Flow Rate
Field: Volume Ratio
Field: Leak Rate Coefficient
Field: Source Side Heat Transfer Coefficient
Field: Source Side Heat Transfer Resistance1
Field: Source Side Heat Transfer Resistance2
Coil:Heating:WaterToAirHeatPump:EquationFit
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Rated Air Flow Rate
Field: Rated Water Flow Rate
Field: Rated Heating Capacity
Field: Rated Heating Coefficient of Performance
Field: Heating Capacity Coefficient 1-5
Field: Heating Power Consumption Coefficient 1-5
Water to Air Heat Pump Heating Coil (parameter Estimation and Equation Fit) Outputs
Heating Coil Electric Power [W]
Heating Coil Heating Rate [W]
Heating Coil Sensible Heating Rate [W]
Heating Coil Source Side Heat Transfer Rate [W]
Heating Coil Part Load Ratio []
Heating Coil Runtime Fraction []
Heating Coil Air Mass Flow Rate [kg/s]
Heating Coil Air Inlet Temperature [C]
Heating Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Air Outlet Temperature [C]
Heating Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Source Side Mass Flow Rate [kg/s]
Heating Coil Source Side Inlet Temperature [C]
Heating Coil Source Side Outlet Temperature [C]
Heating Coil Electric Energy [J]
Heating Coil Heating Energy [J]
Heating Coil Source Side Heat Transfer Energy [J]
Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit
Field: Name
Field: Water Inlet Node Name
Field: Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Number of Speeds
Field: Nominal Speed Level
Field: Rated Total Heating Capacity at Selected Nominal Speed Level
Field: Rated Volumetric Air Flow Rate
Field: Rated Volumetric Water Flow Rate
Field: Part Load Fraction Correlation Curve Name
Field Group: rated specification, performance curves, and waste heat data
Field: Speed Reference Unit Total Heating Capacity
Field: Speed Reference Unit COP
Field: Speed Reference Unit Volumetric Air Flow Rate
Field: Speed Reference Unit Volumetric Water Flow Rate
Field: Speed Total Heating Capacity Function of Temperature Curve Name
Field: Speed Total Heating Capacity Function of Air Flow Fraction Curve Name
Field: Speed Total Heating Capacity Function of Water Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Temperature Curve Name
Field: Speed Energy Input Ratio Function of Air Flow Fraction Curve Name
Field: Speed Energy Input Ratio Function of Water Flow Fraction Curve Name
Field: Speed Rated Waste Heat Fraction of Power Input
Field: Speed Waste Heat Function of Temperature Curve Name
Variable Speed Water to Air Heat Pump Heating Coil Outputs
Heating Coil Electric Power [W]
Heating Coil Heating Rate [W]
Heating Coil Sensible Heating Rate [W]
Heating Coil Source Side Heat Transfer Rate [W]
Heating Coil Part Load Ratio []
Heating Coil Runtime Fraction []
Heating Coil Air Mass Flow Rate [kg/s]
Heating Coil Air Inlet Temperature [C]
Heating Coil Air Inlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Air Outlet Temperature [C]
Heating Coil Air Outlet Humidity Ratio [kgWater/kgDryAir]
Heating Coil Source Side Mass Flow Rate [kg/s]
Heating Coil Source Side Inlet Temperature [C]
Heating Coil Source Side Outlet Temperature [C]
Heating Coil Upper Speed Level []
Heating Coil Neighboring Speed Levels Ratio []
Heating Coil Recoverable Heat Transfer Rate [W]
Heating Coil Electric Energy [J]
Heating Coil Heating Energy [J]
Heating Coil Source Side Heat Transfer Energy [J]
Group – Fans
Fan:ConstantVolume
Field: Name
Field: Availability Schedule Name
Field: Fan Efficiency
Field: Pressure Rise
Field: Maximum Flow Rate
Field: Motor Efficiency
Field: Motor In Airstream Fraction
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: End-Use Subcategory
Constant Volume Fan Outputs
Fan Electric Power [W]
Fan Rise in Air Temperature [deltaC]
Fan Electric Energy [J]
Fan:OnOff
Field: Name
Field: Availability Schedule Name
Field: Fan Efficiency
Field: Pressure Rise
Field: Maximum Flow Rate
Field: Motor Efficiency
Field: Motor In Airstream Fraction
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Fan Power Ratio Function of Speed Ratio Curve Name
Field: Fan Efficiency Ratio Function of Speed Ratio Curve Name
Field: End-Use Subcategory
On Off Fan Outputs
Fan Electric Power [W]
Fan Rise in Air Temperature [deltaC]
Fan Electric Energy [J]
Fan Runtime Fraction []
Fan:VariableVolume
Field: Name
Field: Availability Schedule Name
Field: Fan Efficiency
Field: Pressure Rise
Field: Maximum Flow Rate
Field: Fan Power Minimum Flow Rate Input Method
Field: Fan Power Minimum Flow Fraction
Field: Fan Power Minimum Air Flow Rate
Field: Motor Efficiency
Field: Motor In Airstream Fraction
Field: Fan Power Coefficient 1
Field: Fan Power Coefficient 2
Field: Fan Power Coefficient 3
Field: Fan Power Coefficient 4
Field: Fan Power Coefficient 5
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: End-Use Subcategory
Variable Volume Fan Outputs
Fan Electric Power [W]
Fan Rise in Air Temperature [deltaC]
Fan Electric Energy [J]
Fan:ZoneExhaust
Field: Name
Field: Availability Schedule Name
Field: Fan Efficiency
Field: Pressure Rise
Field: Maximum Flow Rate
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: End-Use Subcategory
Field: Flow Fraction Schedule Name
Field: System Availability Manager Coupling Mode
Field: Minimum Zone Temperature Limit Schedule Name
Field: Balanced Exhaust Fraction Schedule Name
Zone Exhaust Fan Outputs
Fan Electric Power [W]
Fan Rise in Air Temperature [deltaC]
Fan Electric Energy [J]
Fan Unbalanced Air Mass Flow Rate [kg/s]
Fan Balanced Air Mass Flow Rate [kg/s]
FanPerformance:NightVentilation
Field: Fan Name
Field: Fan Efficiency
Field: Pressure Rise
Field: Maximum Flow Rate
Field: Motor Efficiency
Field: Motor in Airstream Fraction
Fan:ComponentModel
Field: Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Availability Schedule Name
Field: Maximum Flow Rate
Field: Minimum Flow Rate
Field: Fan Sizing Factor
Field: Fan Wheel Diameter
Field: Fan Outlet Area
Field: Maximum Fan Static Efficiency
Field: Euler Number at Maximum Fan Static Efficiency
Field: Maximum Dimensionless Fan Airflow
Field: Motor Fan Pulley Ratio
Field: Belt Maximum Torque
Field: Belt Sizing Factor
Field: Belt Fractional Torque Transition
Field: Motor Maximum Speed
Field: Maximum Motor Output Power
Field: Motor Sizing Factor
Field: Motor In Airstream Fraction
Field: VFD Efficiency Type
Field: Maximum VFD Output Power
Field: VFD Sizing Factor
Field: Fan Pressure Rise Curve Name
Field: Duct Static Pressure Reset Curve Name
Field: Normalized Fan Static Efficiency Curve Name– Non-Stall Region
Field: Normalized Fan Static Efficiency Curve Name– Stall Region
Field: Normalized Dimensionless Airflow Curve Name – Non-Stall Region
Field: Normalized Dimensionless Airflow Curve Name – Stall Region
Field: Maximum Belt Efficiency Curve Name
Field: Normalized Belt Efficiency Curve Name – Region 1
Field: Normalized Belt Efficiency Curve Name – Region 2
Field: Normalized Belt Efficiency Curve Name – Region 3
Field: Maximum Motor Efficiency Curve Name”field-normalized-motor-efficiency-curve-name
Field: VFD Efficiency Curve Name
Field: End-Use Subcategory
Component Model Fan Outputs
Fan Electric Power [W]
Fan Rise in Air Temperature [deltaC]
Fan Electric Energy [J]
Other Outputs
Group – Humidifiers
Humidifier:Steam:Electric
Field: Name
Field: Availability Schedule Name
Field: Rated Capacity
Field: Rated Power
Field: Rated Fan Power
Field: Standby Power
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Water Storage Tank Name
Steam Electric Humidfier Outputs
Humidifier Water Volume Flow Rate [m3/s]
Humidifier Water Volume[m3]
Humidifier Electric Power[W]
Humidifier Electric Energy [J]
Humidifier:Water [m3]
Humidifier:Electricity [J]
Humidifier Storage Tank Water Volume Flow Rate [m3/s]
Humidifier Storage Tank Water Volume [m3]
Humidifier Starved Storage Tank Water Volume Flow Rate [m3/s]
Humidifier Starved Storage Tank Water Volume [m3]
Humidifier Mains Water Volume [m3]
Group – Desiccant Dehumidifiers
Dehumidifier:Desiccant:NoFans
Field: Name
Field: Availability Schedule Name
Field: Process Air Inlet Node Name
Field: Process Air Outlet Node Name
Field: Regeneration Air inlet Node Name
Field: Regeneration Fan Inlet Node Name
Field: Control Type
Field: Leaving Maximum Humidity Ratio Setpoint
Field: Nominal Process Air Flow Rate
Field: Nominal Process Air Velocity
Field: Rotor Power
Field: Regeneration Coil Object Type
Field: Regeneration Coil Name
Field: Regeneration Fan Object Type
Field: Regeneration Fan Name
Field: Performance Model Type
Field: Leaving Dry-Bulb Function of Entering Dry-Bulb and Humidity Ratio Curve Name
Field: Leaving Dry-Bulb Function of Air Velocity Curve Name
Field: Leaving Humidity Ratio Function of Entering Dry-Bulb and Humidity Ratio Curve Name
Field: Leaving Humidity Ratio Function of Air Velocity Curve Name
Field: Regeneration Energy Function of Entering Dry-Bulb and Humidity Ratio Curve Name
Field: Regeneration Energy Function of Air Velocity Curve Name
Field: Regeneration Velocity Function of Entering Dry-Bulb and Humidity Ratio Curve Name
Field: Regeneration Velocity Function of Air Velocity Curve Name
Field: Nominal Regeneration Temperature
Desiccant Dehumidifier (NoFans) Outputs
Dehumidifier Removed Water Mass [kg]
Dehumidifier Removed Water Mass Flow Rate [kg/s]
Dehumidifier Part Load Ratio []
Dehumidifier Electric Power [W]
Dehumidifier Electric Energy [J]
Dehumidifier Regeneration Specific Energy [J/kgWater]
Dehumidifier Regeneration Rate [W]
Dehumidifier Regeneration Energy [J]
Dehumidifier Regeneration Air Speed[m/s]
Dehumidifier Regeneration Air Mass Flow Rate [kg/s]
Dehumidifier Process Air Mass Flow Rate [kg/s]
Dehumidifier:Desiccant:System
Field: Name
Field: Availability Schedule Name
Field: Desiccant Heat Exchanger Object Type
Field: Desiccant Heat Exchanger Name
Field: Sensor Node Name”field-regeneration-air-fan-object-type
Field: Regeneration Air Fan Name
Field: Regeneration Air Fan Placement
Field: Regeneration Air Heater Object Type
Field: Regeneration Air Heater Name
Field: Regeneration Inlet Air Setpoint Temperature
Field: Companion Cooling Coil Object Type
Field: Companion Cooling Coil Name
Field: Companion Cooling Coil Upstream of Dehumidifier Process Inlet
Field: Companion Coil Regeneration Air Heating
Field: Exhaust Fan Maximum Flow Rate
Field: Exhaust Fan Maximum Power
Field: Exhaust Fan Power Curve Name
Desiccant Dehumidifier Outputs
Dehumidifier Removed Water Mass [kg]
Dehumidifier Removed Water Mass Flow Rate [kg/s]
Dehumidifier Part Load Ratio [ ]
Dehumidifier Exhaust Fan Electric Power [W]
Dehumidifier Exhaust Fan Electric Energy [J]
Group – Energy Management System (EMS)
EnergyManagementSystem:Sensor
Field: Name
Field: Output:Variable or Output:Meter Index Key Name
Field: Output:Variable or Output:Meter Name
EnergyManagementSystem:Actuator
Field: Name
Field: Actuated Component Unique Name
Field: Actuated Component Type
Field: Actuated Component Control Type
EnergyManagementSystem:ProgramCallingManager
Field: Name
Field: EnergyPlus Model Calling Point
Field: Program Name 1
Field: Program Name 2 .. N
EnergyManagementSystem:Program
Field: Name
Field Set: Program lines 1 to N
EnergyManagementSystem:Subroutine
Field: Name
Field set: Lines 1 to N
EnergyManagementSystem:GlobalVariable
Field: Erl Variable (1..N) Name
EnergyManagementSystem:OutputVariable
Field: Name
Field: EMS Variable Name
Field: Type of Data in Variable
Field: Update Frequency
Field: EMS Program or Subroutine Name
EnergyManagementSystem:MeteredOutputVariable,
Field: Name
Field: EMS Variable Name
Field: Update Frequency
Field: EMS Program or Subroutine Name
Field: Resource Type
Field: Group Type
Field: End-Use Category
Field: End-Use Subcategory
EnergyManagementSystem:TrendVariable
Field: Name
Field: EMS Variable Name
Field: Number of Timesteps to be Logged
EnergyManagementSystem:InternalVariable
Field: Name
Field: Internal Data Index Key Name
Field: Internal Data Type
EnergyManagementSystem:CurveOrTableIndexVariable
Field: Name
Field: Curve or Table Object Name
EnergyManagementSystem:ConstructionIndexVariable
Field: Name
Field: Construction Object Name
Group – ExternalInterface
ExternalInterface
Field: Name
Building Controls Virtual Test Bed (BCVTB)
ExternalInterface:Schedule
Field: Name
Field: Schedule Type Limits Name
Field: Initial Value
ExternalInterface:Actuator
Field: Name
Field: Actuated Component Unique Name
Field: Actuated Component Type
Field: Actuated Component Control Type
Field: Initial Value
ExternalInterface:Variable
Field: Name
Field: Initial Value
Functional Mock-up Unit (FMU) Import
ExternalInterface:FunctionalMockupUnitImport
Field: FMU File Name
Field: FMU Timeout
Field: FMU LoggingOn
ExternalInterface:FunctionalMockupUnitImport:From:Variable
Field: EnergyPlus Key Value
Field: EnergyPlus Variable Name
Field: FMU File Name
Field: FMU Instance Name
Field: FMU Variable Name
ExternalInterface:FunctionalMockupUnitImport:To:Schedule
Field: EnergyPlus Variable Name
Field: Schedule Type Limits Name
Field: FMU File Name
Field: FMU Instance Name
Field: FMU Variable Name
Field: Initial Value
ExternalInterface:FunctionalMockupUnitImport:To:Actuator
Field: EnergyPlus Variable Name
Field: Actuated Component Unique Name
Field: Actuated Component Type
Field: Actuated Component Control Type
Field: FMU File Name
Field: FMU Instance Name
Field: FMU Variable Name
Field: Initial Value
ExternalInterface:FunctionalMockupUnitImport:To:Variable
Field: EnergyPlus Variable Name
Field: FMU File Name
Field: FMU Instance Name
Field: FMU Variable Name
Field: Initial Value
Functional Mock-up Unit (FMU) Export
ExternalInterface:FunctionalMockupUnitExport:From:Variable
Field: EnergyPlus Key Value
Field: EnergyPlus Variable Name
Field: FMU Variable Name
ExternalInterface:FunctionalMockupUnitExport:To:Schedule
Field: EnergyPlus Variable Name
Field: Schedule Type Limits Name
Field: FMU Variable Name
Field: Initial Value
ExternalInterface:FunctionalMockupUnitExport:To:Actuator
Field: EnergyPlus Variable Name
Field: Actuated Component Unique Name
Field: Actuated Component Type
Field: Actuated Component Control Type
Field: FMU Variable Name
Field: Initial Value
ExternalInterface:FunctionalMockupUnitExport:To:Variable
Field: EnergyPlus Variable Name
Field: FMU Variable Name
Field: Initial Value
Group – User Defined HVAC and Plant Component Models
ZoneHVAC:ForcedAir:UserDefined
Field: Name
Field: Overall Model Simulation Program Calling Manager Name
Field: Model Setup and Sizing Program Calling Manager Name
Field: Primary Air Inlet Node Name
Field: Primary Air Outlet Node Name
Field: Secondary Air Inlet Node Name
Field: Secondary Air Outlet Node Name
Field: Number of Plant Loop Connections
Field: Plant Connection 1 Inlet Node Name
Field: Plant Connection 1 Outlet Node Name
Field: Plant Connection 2 Inlet Node Name
Field: Plant Connection 2 Outlet Node Name
Field: Plant Connection 3 Inlet Node Name
Field: Plant Connection 3 Outlet Node Name
Field: Supply Inlet Water Storage Tank Name
Field: Collection Outlet Water Storage Tank Name
Field: Ambient Zone Name
AirTerminal:SingleDuct:UserDefined
Field: Name
Field: Overall Model Simulation Program Calling Manager Name
Field: Model Setup and Sizing Program Calling Manager Name
Field: Primary Air Inlet Node Name
Field: Primary Air Outlet Node Name
Field: Secondary Air Inlet Node Name
Field: Secondary Air Outlet Node Name
Field: Number of Plant Loop Connections
Field: Plant Connection 1 Inlet Node Name
Field: Plant Connection 1 Outlet Node Name
Field: Plant Connection 2 Inlet Node Name
Field: Plant Connection 2 Outlet Node Name
Field: Supply Inlet Water Storage Tank Name
Field: Collection Outlet Water Storage Tank Name
Field: Ambient Zone Name
Coil:UserDefined
Field: Name
Field: Overall Model Simulation Program Calling Manager Name
Field: Model Setup and Sizing Program Calling Manager Name
Field: Number of Air Connections
Field: Air Connection 1 Inlet Node Name
Field: Air Connection 1 Outlet Node Name
Field: Air Connection 2 Inlet Node Name
Field: Air Connection 2 Outlet Node Name
Field: Plant Connection is Used
Field: Plant Connection Inlet Node Name
Field: Plant Connection Outlet Node Name”field-supply-inlet-water-storage-tank-name-2
Field: Collection Outlet Water Storage Tank Name
Field: Ambient Zone Name
PlantComponent:UserDefined
Field: Name
Field: Main Model Program Calling Manager Name
Field: Number of Plant Loop Connections
FeildSet: {inlet node name, outlet node name, loading mode, flow request mode, initialization program calling manager, simulation program calling manager.}
Field: Plant Connection X Inlet Node Name
Field: Plant Connection X Outlet Node Name
Field: Plant Connection X Loading Mode
Field: Plant Connection X Loop Flow Request Mode
Field: Plant Connection X Initialization Program Calling Manager Name
Field: Plant Connection X Simulation Program Calling Manager Name
Field: Air Connection Inlet Node Name
Field: Air Connection Outlet Node Name
Field: Supply Inlet Water Storage Tank Name
Field: Collection Outlet Water Storage Tank Name
Field: Ambient Zone Name
Group – System Availability Managers
AvailabilityManager:Scheduled
Field: Name
Field: Schedule Name
Availability Manager Scheduled Control Status
AvailabilityManager:ScheduledOn
Field: Name
Field: Schedule Name
AvailabilityManager:ScheduledOn Outputs
Availability Manager Scheduled On Control Status []
AvailabilityManager:ScheduledOff
Field: Name
Field: Schedule Name
AvailabilityManager:ScheduledOff Outputs
Availability Manager Scheduled Off Control Status []
AvailabilityManager:NightCycle
AvailabilityManager:NightCycle Outputs
Availability Manager Night Cycle Control Status
AvailabilityManager:DifferentialThermostat
Field: Name
Field: Hot Node Name
Field: Cold Node Name
Field: Temperature Difference On Limit
Field: Temperature Difference Off Limit
AvailabilityManager:DifferentialThermostat Outputs
Availability Manager Differential Thermostat Control Status
AvailabilityManager:HighTemperatureTurnOff
Field: Name
Field: Sensor Node Name
Field: Temperature
AvailabilityManager:HighTemperatureTurnOff Outputs
Availability Manager High Temperature Turn Off Control Status []
AvailabilityManager:HighTemperatureTurnOn
Field: Name
Field: Sensor Node Name
Field: Temperature
AvailabilityManager:HighTemperatureTurnOn Outputs
Availability Manager High Temperature Turn On Control Status []
AvailabilityManager:LowTemperatureTurnOff
Field: Name
Field: Sensor Node Name
Field: Temperature
Field: Applicability Schedule Name
AvailabilityManager:LowTemperatureTurnOff Outputs
AvailabilityManager:LowTemperatureTurnOn
Field: Name
Field: Sensor Node Name
Field: Temperature
AvailabilityManager:LowTemperatureTurnOn Outputs
Availability Manager Low Temperature Turn On Control Status []
AvailabilityManager:NightVentilation
Field: Name
Field: Applicability Schedule Name
Field: Fan Schedule Name
Field: Ventilation Temperature Schedul e Name”field-ventilation-temperature-difference
Field: Ventilation Temperature Low Limit
Field: Night Venting Flow Fraction
Field: Control Zone Name
System Availability Manager Night Ventilation Outputs
Availability Manager Night Ventilation Control Status []
AvailabilityManager:HybridVentilation
Field: Name
Field: HVAC Air Loop Name
Field: Controlled Zone Name
Field: Ventilation Control Mode Schedule Name
Field: Use Weather File Rain Indicators
Field: Maximum Wind Speed
Field: Minimum Outdoor Temperature
Field: Maximum Outdoor Temperature
Field: Minimum Outdoor Enthalpy
Field: Maximum Outdoor Enthalpy
Field: Minimum Outdoor Dewpoint
Field: Maximum Outdoor Dewpoint
Field: Minimum Outdoor Ventilation Air Schedule Name
Field: Opening Factor Function of Wind Speed Curve Name
Field: AirflowNetwork Control Type Schedule Name
Field: Simple Airflow Control Type Schedule Name
Field: ZoneVentilation Object Name
AvailabilityManager:HybridVentilation Outputs
Availability Manager Hybrid Ventilation Control Mode []
Availability Manager Hybrid Ventilation Control Status []
Group – Setpoint Managers
SetpointManager:Scheduled
Field: Name
Field: Control Variable
Field: Schedule Name
Field: Setpoint Node or NodeList Name
SetpointManager:Scheduled:DualSetpoint
Field: Name
Field: Control Variable
Field: High Setpoint Schedule Name
Field: Low Setpoint Schedule Name
Field: Setpoint Node or NodeList Name
SetpointManager:OutdoorAirReset
Field: Name
Field: Control Variable
Field: Setpoint at Outdoor Low Temperature
Field: Outdoor Low Temperature
Field: Setpoint at Outdoor High Temperature
Field: Outdoor High Temperature
Field: Setpoint Node or NodeList Name
Field: Schedule Name
Field: Setpoint at Outdoor Low Temperature 2
Field: Outdoor Low Temperature 2
Field: Setpoint at Outdoor High Temperature 2
Field: Outdoor High Temperature 2
SetpointManager:SingleZone:Reheat
Field: Name
Field: Control Variable
Field: Minimum Supply Air Temperature
Field: Maximum Supply Air Temperature
Field: Control Zone Name
Field: Zone Node Name
Field: Zone Inlet Node Name
Field: Setpoint Node or NodeList Name
SetpointManager:SingleZone:Heating
Field: Name
Field: Control Variable
Field: Minimum Supply Air Temperature
Field: Maximum Supply Air Temperature
Field: Control Zone Name
Field: Zone Node Name
Field: Zone Inlet Node Name
Field: Setpoint Node or NodeList Name
SetpointManager:SingleZone:Cooling
Field: Name
Field: Control Variable
Field: Minimum Supply Air Temperature
Field: Maximum Supply Air Temperature
Field: Control Zone Name
Field: Zone Node Name
Field: Zone Inlet Node Name
Field: Setpoint Node or NodeList Name
SetpointManager:SingleZone:Humidity:Minimum
Field: Name
Field: Control Variable
Field: Schedule Name
Field: Setpoint Node or NodeList Name
Field: Control Zone Air Node Name
SetpointManager:SingleZone:Humidity:Maximum
Field: Name
Field: Control Variable
Field: Schedule Name
Field: Setpoint Node or NodeList Name
Field: Control Zone Air Node Name
SetpointManager:MixedAir
Field: Name
Field: Control Variable
Field: Reference Setpoint Node Name
Field: Fan Inlet Node Name
Field: Fan Outlet Node Name
Field: Setpoint Node or NodeList Name
SetpointManager:OutdoorAirPretreat
Field: Name
Field: Control Variable
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Minimum Setpoint Humidity Ratio
Field: Maximum Setpoint Humidity Ratio
Field: Reference Setpoint Node Name
Field: Mixed Air Stream Node Name
Field: Outdoor Air Stream Node Name
Field: Return Air Stream Node Name
Field: Setpoint Node or NodeList Name
SetpointManager:Warmest
Field: Name
Field: Control Variable
Field: HVAC Air Loop Name
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Strategy
Field: Setpoint Node or NodeList Name
SetpointManager:Coldest
Field: Name
Field: Control Variable
Field: HVAC Air Loop Name
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Strategy
Field: Setpoint Node or NodeList Name
SetpointManager:ReturnAirBypassFlow
Field: Name
Field: Control Variable
Field: HVAC Air Loop Name
Field: Temperature Setpoint Schedule Name
SetpointManager:WarmestTemperatureFlow
Field: Name
Field: Control Variable
Field: HVAC Air Loop Name
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Strategy
Field: Setpoint Node or NodeList Name
Field: Minimum Turndown Ratio
SetpointManager:WarmestTemperatureFlow Outputs
Setpoint Manager Warmest Temperature Critical Zone Number []
Setpoint Manager Warmest Temperature Turndown Flow Fraction []
SetpointManager:MultiZone:Cooling:Average
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Setpoint Node or NodeList Name
SetpointManager:MultiZone:Heating:Average
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Temperature
Field: Maximum Setpoint Temperature
Field: Setpoint Node or NodeList Name
SetpointManager:MultiZone:MinimumHumidity:Average
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Humidity Ratio
Field: Maximum Setpoint Humidity Ratio
Field: Setpoint Node or NodeList Name
SetpointManager:MultiZone:MaximumHumidity:Average
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Humidity Ratio
Field: Maximum Setpoint Humidity Ratio
Field: Setpoint Node or NodeList Name
SetpointManager:MultiZone:Humidity:Minimum
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Humidity Ratio
Field: Maximum Setpoint Humidity Ratio
Field: Setpoint Node or NodeList Name
SetpointManager:MultiZone:Humidity:Maximum
Field: Name
Field: HVAC Air Loop Name
Field: Minimum Setpoint Humidity Ratio
Field: Maximum Setpoint Humidity Ratio
Field: Setpoint Node or NodeList Name
SetpointManager:FollowOutdoorAirTemperature
Field: Name
Field: Control Variable
Field: Reference Temperature Type
Field: Offset Temperature Difference
Field: Maximum Setpoint Temperature
Field: Minimum Setpoint Temperature
Field: Setpoint Node or NodeList Name
SetpointManager:FollowSystemNodeTemperature
Field: Name
Field: Control Variable
Field: Reference Node Name
Field: Reference Temperature Type
Field: Offset Temperature Difference
Field: Maximum Limit Setpoint Temperature
Field: Minimum Limit Setpoint Temperature
Field: Setpoint System Node or NodeList Name
SetpointManager:FollowGroundTemperature
Field: Name
Field: Control Variable
Field: Reference Ground Temperature Object Type
Field: Offset Temperature Difference
Field: Maximum Setpoint Temp erature”field-minimum-setpoint-temperature-7
Field: Setpoint System Node or NodeList Name
SetpointManager:CondenserEnteringReset
Field: Name
Field: Control variable
Field: Default Condenser Entering Water Temperature Schedule Name
Field: Minimum Design Wetbulb Temperature Curve Name
Field: Minimum Outside Air Wetbulb Temperature Curve Name
Field: Optimized Condenser Entering Temperature Curve Name
Field: Minimum Lift
Field: Maximum Condenser Entering Temperature
Field: Cooling Tower Design Inlet Air Wet-Bulb Temperature
Field: Setpoint Node or Node List Name
SetpointManager:CondenserEnteringReset:Ideal
Field: Name
Field: Control variable
Field: Minimum Lift
Field: Maximum Condenser Entering Water Temperature
Field: Setpoint Node or Node List Name
Group – Controllers
Controls (Air Loop and Zone Equipment)
Controller:WaterCoil
Field: Name
Field: Control Variable
Field: Action
Field: Actuator Variable
Field: Sensor Node Name
Field: Actuator Node Name
Field: Controller Convergence Tolerance
Field: Maximum Actuated Flow
Field: Minimum Actuated Flow
Controller:OutdoorAir
Field: Name
Field: Relief Air Outlet Node Name
Field: Return Air Node Name
Field: Mixed Air Node Name
Field: Actuator Node Name
Field: Minimum Outdoor Air Flow Rate
Field: Maximum Outdoor Air Flow Rate
Field: Economizer Control Type
Field: Economizer Control Action Type
Field: Economizer Maximum Limit Dry-Bulb Temperature
Field: Economizer Maximum Limit Enthalpy
Field: Economizer Maximum Limit Dewpoint Temperature
Field: Electronic Enthalpy Limit Curve Name
Field: Economizer Minimum Limit Dry-Bulb Temperature
Field: Lockout Type
Field: Minimum Limit Type
Field: Minimum Outdoor Air Schedule Name
Field: Minimum Fraction of Outdoor Air Schedule Name
Field: Maximum Fraction of Outdoor Air Schedule Name
Field: Mechanical Ventilation Controller Name
Field: Time of Day Economizer Control Schedule Name
Field: High Humidity Control
Field: Humidistat Control Zone Name
Field: High Humidity Outdoor Air Flow Ratio
Field: Control High Indoor Humidity Based on Outdoor Humidity Ratio
Field: Heat Recovery Bypass Control Type
Controller:OutdoorAir Outputs
Air System Outdoor Air Economizer Status []
Air System Outdoor Air Heat Recovery Bypass Status []
Air System Outdoor Air Heat Recovery Bypass Heating Coil Activity Status []
Air System Outdoor Air Heat Recovery Bypass Minimum Outdoor Air Mixed Air Temperature [C]
Air System Outdoor Air High Humidity Control Status []
Air System Outdoor Air Flow Fraction []
Air System Outdoor Air Minimum Flow Fraction []
Air System Outdoor Air Mass Flow Rate [kg/s]
Air System Mixed Air Mass Flow Rate [kg/s]
Controller:MechanicalVentilation
The first five inputs for this object are the name, the availability schedule, the zone outdoor air method, the system outdoor air method, and the zone maximum outdoor air fraction. The next three input fields define the zone name (or zone list name), the design specification outdoor air object name, and the design specification zone air distribution object name to be applied to this zone (or zone list). The last three fields are extensible
Field: Name
Field: Availability Schedule Name
Field: Demand Controlled Ventilation
Field: System Outdoor Air Method
Field: Zone Maximum Outdoor Air Fraction
Field Set (Zone Name, Design Specification Outdoor Air Object Name, and Design Specification Zone Air Distribution Object Name)
Field: Zone Name
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
ZoneHVAC:EnergyRecoveryVentilator:Controller
Field: Name
Field: Temperature High Limit
Field: Temperature Low Limit
Field: Enthalpy High Limit
Field: Dewpoint Temperature Limit
Field: Electronic Enthalpy Limit Curve Name
Field: Exhaust Air Temperature Limit
Field: Exhaust Air Enthalpy Limit
Field: Time of Day Economizer Flow Control Schedule Name
Field: High Humidity Control Flag
Field: Humidistat Control Zone Name
Field: High Humidity Outdoor Air Flow Ratio
Field: Control High Indoor Humidity based on Outdoor Humidity Ratio
Group – Evaporative Coolers
EvaporativeCooler:Direct:CelDekPad
Field: Name
Field: Availability Schedule Name
Field: Direct Pad Area
Field: Direct Pad Depth
Field: Recirculating Water Pump Power Consumption
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Control Type
Field: Water Supply Storage Tank Name
EvaporativeCooler:Direct:CelDekPad Outputs
Evaporative Cooler Wet Bulb Effectiveness
Evaporative Cooler Electric Power[W]
Evaporative Cooler Electric Energy [J]
Evaporative Cooler Water Volume [m3]
Evaporative Cooler Mains Water Volume [m3]
Evaporative Cooler Storage Tank Water Volume [m3]
Evaporative Cooler Starved Water Volume [m3]
Evaporative Cooler Starved Mains Water Volume [m3]
EvaporativeCooler:Direct:ResearchSpecial
Field: Name
Field: Availability Schedule Name
Field: Cooler Effectiveness
Field: Recirculationg Water Pump Power Consumption
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Sensor Node Name
Field: Water Supply Storage Tank Name
Field: Drift Loss Fraction
Field: Blowdown Concentration Ratio
EvaporativeCooler:Direct:ResearchSpecial Outputs
Evaporative Cooler Electric Power[W]
Evaporative Cooler Electric Energy [J]
Evaporative Cooler Water Volume [m3]
Evaporative Cooler Mains Water Volume [m3]
Evaporative Cooler Storage Tank Water Volume [m3]
Evaporative Cooler Starved Water Volume [m3]
Evaporative Cooler Starved Mains Water Volume [m3]
EvaporativeCooler:Indirect:CelDekPad
Field: Name
Field: Availability Schedule Name
Field: Direct Pad Area
Field: Direct Pad Depth
Field: Recirculating Water Pump Power Consumption
Field: Secondary Fan Flow Rate
Field: Secondary Fan Efficiency
Field: Secondary Fan Delta Pressure
Field: Indirect Heat Exchanger Effectiveness
Field: Primary Air Inlet Node Name
Field: Primary Air Outlet Node Name
Field: Control Type
Field: Water Supply Storage Tank Name
Field: Secondary Air Inlet Node Name
EvaporativeCooler:Indirect:CelDekPad Outputs
Evaporative Cooler Wetbulb Effectiveness
Evaporative Cooler Total Stage Effectiveness
Evaporative Cooler Electric Power[W]
Evaporative Cooler Electric Energy [J]
Evaporative Cooler Water Volume[m3]
Evaporative Cooler Mains Water Volume [m3]
Evaporative Cooler Storage Tank Water Volume [m3]
Evaporative Cooler Starved Water Volume [m3]
Evaporative Cooler Starved Mains Water Volume [m3]
EvaporativeCooler:Indirect:WetCoil
Field: Name
Field: Availability Schedule Name
Field: Coil Maximum Efficiency
Field: Coil Flow Ratio
Field: Recirculating Water Pump Power Consumption
Field: Secondary Fan Flow Rate
Field: Secondary Fan Efficiency
Field: Secondary Fan Delta Pressure
Field: Primary Air Inlet Node Name
Field: Primary Air Outlet Node Name
Field: Control Type
Field: Water Supply Storage Tank Name
Field: Secondary Air Inlet Node Name
Field: Drift Loss Fraction
Field: Blowdown Concentration Ratio
EvaporativeCooler:Indirect:WetCoil Outputs
Evaporative Cooler Total Stage Effectiveness []
Evaporative Cooler Electric Power [W]
Evaporative Cooler Electric Energy [J]
Evaporative Cooler Water Volume [m3]
Evaporative Cooler Mains Water Volume [m3]
Evaporative Cooler Storage Tank Water Volume [m3]
Evaporative Cooler Starved Water Volume [m3]
Evaporative Cooler Starved Mains Water Volume [m3]
EvaporativeCooler:Indirect:ResearchSpecial
Field: Name
Field: Availability Schedule Name
Field: Cooler Maximum Effectiveness
Field: Cooler Flow Ratio
Field: Recirculating Water Pump Power Consumption
Field: Secondary Fan Flow Rate
Field: Secondary Fan Efficiency
Field: Secondary Fan Delta Pressure
Field: Primary Air Inlet Node Name
Field: Primary Air Outlet Node Name
Field: Control Type
Field: Dewpoint Effectiveness Factor
Field: Secondary Air Inlet Node Name”field-sensor-node-name-1
Field: Relief Air Inlet Node Name
Field: Water Supply Storage Tank Name
Field: Drift Loss Fraction
Field: Blowdown Concentration Ratio
EvaporativeCooler:Indirect:ResearchSpecial Outputs
Evaporative Cooler Total Stage Effectiveness []
Evaporative Cooler Part Load Ratio []
Evaporative Cooler Dewpoint Bound Status []
Evaporative Cooler Electric Power [W]
Evaporative Cooler Electric Energy [J]
Evaporative Cooler Water Volume [m3]
Evaporative Cooler Mains Water Volume [m3]
Evaporative Cooler Storage Tank Water Volume [m3]
Evaporative Cooler Starved Water Volume [m3]
Evaporative Cooler Starved Mains Water Volume [m3]
Group – Heat Recovery
HeatExchanger:AirToAir:FlatPlate
Field: Name
Field: Availability Schedule Name
Field: Flow Arrangement Type
Field: Economizer Lockout
Field: Ratio of Supply to Secondary hA Values
Field: Nominal Supply Air Flow Rate
Field: Nominal Supply Air Inlet Temperature
Field: Nominal Supply Air Outlet Temperature
Field: Nominal Secondary Air Flow Rate
Field: Nominal Secondary Air Inlet Temperature
Field: Nominal Electric Power
Field: Supply Air Inlet Node Name
Field: Supply Air Outlet Node Name
Field: Secondary Air Inlet Node Name
Field: Secondary Air Outlet Node Name
HeatExchanger:AirToAir:FlatPlate Outputs
Heat Exchanger Sensible Heating Rate [W]
Heat Exchanger Sensible Heating Energy [J]
Heat Exchanger Latent Gain Rate [W]
Heat Exchanger Latent Heating Energy [J]
Heat Exchanger Total Heating Rate [W]
Heat Exchanger Total Heating Energy [J]
Heat Exchanger Sensible Cooling Rate [W]
Heat Exchanger Sensible Cooling Energy [J]
Heat Exchanger Latent Cooling Rate [W]
Heat Exchanger Latent Cooling Energy [J]
Heat Exchanger Total Cooling Rate [W]
Heat Exchanger Total Cooling Energy [J]
Heat Exchanger Electric Power [W]
Heat Exchanger Electric Energy [J]
HeatExchanger:AirToAir:SensibleAndLatent
Field: Name
Field: Availability Schedule Name
Field: Nominal Supply Air Flow Rate
Field: Sensible Effectiveness at 100% Heating Air Flow
Field: Latent Effectiveness at 100% Heating Air Flow
Field: Sensible Effectiveness at 75% Heating Air Flow
Field: Latent Effectiveness at 75% Heating Air Flow
Field: Sensible Effectiveness at 100% Cooling Air Flow
Field: Latent Effectiveness at 100% Cooling Air Flow
Field: Sensible Effectiveness at 75% Cooling Air Flow
Field: Latent Effectiveness at 75% Cooling Air Flow
Field: Supply Air Inlet Node Name
Field: Supply Air Outlet Node Name
Field: Exhaust Air Inlet Node Name
Field: Exhaust Air Outlet Node Name
Field: Nominal Electric Power
Field: Supply Air Outlet Temperature Control
Field: Heat Exchanger Type
Field: Frost Control Type
Field: Threshold Temperature
Field: Initial Defrost Time Fraction
Field: Rate of Defrost Time Fraction Increase
Field: Economizer Lockout
HeatExchanger:AirToAir:SensibleAndLatent Outputs
Heat Exchanger Sensible Heating Rate [W]
Heat Exchanger Sensible Heating Energy [J]
Heat Exchanger Latent Gain Rate [W]
Heat Exchanger Latent Gain Energy [J]
Heat Exchanger Total Heating Rate [W]
Heat Exchanger Total Heating Energy [J]
Heat Exchanger Sensible Cooling Rate [W]
Heat Exchanger Sensible Cooling Energy [J]
Heat Exchanger Latent Cooling Rate [W]
Heat Exchanger Latent Cooling Energy [J]
Heat Exchanger Total Cooling Rate [W]
Heat Exchanger Total Cooling Energy [J]
Heat Exchanger Electric Power [W]
Heat Exchanger Electric Energy [J]
Heat Exchanger Sensible Effectiveness []
Heat Exchanger Latent Effectiveness []
Heat Exchanger Supply Air Bypass Mass Flow Rate [kg/s]
Heat Exchanger Exhaust Air Bypass Mass Flow Rate [kg/s]
Heat Exchanger Defrost Time Fraction []
HeatExchanger:Desiccant:BalancedFlow
Field: Name
Field: Availability Schedule Name
Field: Regeneration Air Inlet Node Name
Field: Regeneration Air Outlet Node Name
Field: Process Air Inlet Node Name
Field: Process Air Outlet Node Name
Field: Heat Exchanger Performance Object Type
Field: Heat Exchanger Performance Name
Field: Economizer Lockout
HeatExchanger:Desiccant:BalancedFlow Outputs
Heat Exchanger Sensible Heating Rate [W]
Heat Exchanger Sensible Heating Energy [J]
Heat Exchanger Latent Gain Rate [W]
Heat Exchanger Latent Gain Energy [J]
Heat Exchanger Total Heating Rate [W]
Heat Exchanger Total Heating Energy [J]
Heat Exchanger Sensible Cooling Rate [W]
Heat Exchanger Sensible Cooling Energy [J]
Heat Exchanger Latent Cooling Rate [W]
Heat Exchanger Latent Cooling Energy [J]
Heat Exchanger Total Cooling Rate [W]
Heat Exchanger Total Cooling Energy [J]
Heat Exchanger Electric Power [W]
Heat Exchanger Electric Energy [J]
HeatExchanger:Desiccant:BalancedFlow:PerformanceDataType1
Field: Name
Field: Nominal Air Flow Rate
Field: Nominal Air Face Velocity
Field: Nominal Electric Power
Field: Temperature Equation Coefficient 1
Field: Temperature Equation Coefficient 2
Field: Temperature Equation Coefficient 3
Field: Temperature Equation Coefficient 4
Field: Temperature Equation Coefficient 5
Field: Temperature Equation Coefficient 6
Field: Temperature Equation Coefficient 7
Field: Temperature Equation Coefficient 8
Field: Minimum Regeneration Inlet Air Humidity Ratio for Temperature Equation
Field: Maximum Regeneration Inlet Air Humidity Ratio for Temperature Equation
Field: Minimum Regeneration Inlet Air Temperature for Temperature Equation
Field: Maximum Regeneration Inlet Air Temperature for Temperature Equation
Field: Minimum Process Inlet Air Humidity Ratio for Temperature Equation
Field: Maximum Process Inlet Air Humidity Ratio for Temperature Equation
Field: Minimum Process Inlet Air Temperature for Temperature Equation
Field: Maximum Process Inlet Air Temperature for Temperature Equation
Field: Minimum Regeneration Air Velocity for Temperature Equation
Field: Maximum Regeneration Air Velocity for Temperature Equation
Field: Minimum Regeneration Outlet Air Temperature for Temperature Equation
Field: Maximum Regeneration Outlet Air Temperature for Temperature Equation
Field: Minimum Regeneration Inlet Air Relative Humidity for Temperature Equation
Field: Maximum Regeneration Inlet Air Relative Humidity for Temperature Equation
Field: Minimum Process Inlet Air Relative Humidity for Temperature Equation
Field: Maximum Process Inlet Air Relative Humidity for Temperature Equation
Field: Humidity Ratio Equation Coefficient 1
Field: Humidity Ratio Equati on Coefficient 2”field-humidity-ratio-equation-coefficient-3
Field: Humidity Ratio Equation Coefficient 4
Field: Humidity Ratio Equation Coefficient 5
Field: Humidity Ratio Equation Coefficient 6
Field: Humidity Ratio Equation Coefficient 7
Field: Humidity Ratio Equation Coefficient 8
Field: Minimum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation
Field: Maximum Regeneration Inlet Air Humidity Ratio for Humidity Ratio Equation
Field: Minimum Regeneration Inlet Air Temperature for Humidity Ratio Equation
Field: Maximum Regeneration Inlet Air Temperature for Humidity Ratio Equation
Field: Minimum Process Inlet Air Humidity Ratio for Humidity Ratio Equation
Field: Maximum Process Inlet Air Humidity Ratio for Humidity Ratio Equation
Field: Minimum Process Inlet Air Temperature for Humidity Ratio Equation
Field: Maximum Process Inlet Air Temperature for Humidity Ratio Equation
Field: Minimum Regeneration Air Velocity for Humidity Ratio Equation
Field: Maximum Regeneration Air Velocity for Humidity Ratio Equation
Field: Minimum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation
Field: Maximum Regeneration Outlet Air Humidity Ratio for Humidity Ratio Equation
Field: Minimum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation
Field: Maximum Regeneration Inlet Air Relative Humidity for Humidity Ratio Equation
Field: Minimum Process Inlet Air Relative Humidity for Humidity Ratio Equation
Field: Maximum Process Inlet Air Relative Humidity for Humidity Ratio Equation
HeatExchanger:Desiccant:BalancedFlow:PerformanceDataType1 Outputs
Group – Demand Limiting Controls
DemandManagerAssignmentList
Field: Name
Field: Meter Name
Field: Demand Limit Schedule Name
Field: Demand Limit Safety Fraction
Field: Billing Period Schedule Name
Field: Peak Period Schedule Name
Field: Demand Window Length
Field: Demand Manager Priority
Field: Demand Manager Type 1
Field: Demand Manager Name 1
DemandManagerAssignmentList Outputs
Demand Manager Meter Demand Power [W]
Demand Manager Average Demand Power [W]
Demand Manager Peak Demand Power [W]
Demand Manager Scheduled Limit Power [W]
Demand Manager Demand Limit Power [W]
Demand Manager Avoided Demand [W]
Demand Manager Over Limit Power [W]
Demand Manager Over Limit Time [hr]
Demand Manager Exterior Energy Iteration Count []
Demand Manager Heat Balance Iteration Count []
Demand Manager HVAC Iteration Count []
DemandManager:ExteriorLights
Field: Name
Field: Availability Schedule Name
Field: Limit Control
Field: Minimum Limit Duration
Field: Maximum Limit Fraction
Field: Limit Step Change
Field: Selection Control
Field: Rotation Duration
Field: Exterior Lights 1-10 Name
DemandManager:ExteriorLights Outputs
DemandManager:Lights
Field: Name
Field: Availability Schedule Name
Field: Limit Control
Field: Minimum Limit Duration
Field: Maximum Limit Fraction
Field: Limit Step Change
Field: Selection Control
Field: Rotation Duration
Field: Lights 1-10 Name
DemandManager:Lights Outputs
DemandManager:ElectricEquipment
Field: Name
Field: Availability Schedule Name
Field: Limit Control
Field: Minimum Limit Duration
Field: Maximum Limit Fraction
Field: Limit Step Change
Field: Selection Control
Field: Rotation Duration
Field: Electric Equipment 1-10 Name
DemandManager:ElectricEquipment Outputs
DemandManager:Thermostats
Field: Name
Field: Availability Schedule Name
Field: Reset Control
Field: Minimum Reset Duration
Field: Maximum Heating Setpoint Reset
Field: Maximum Cooling Setpoint Reset
Field: Reset Step Change
Field: Selection Control
Field: Rotation Duration
Field: Thermostat 1-10 Name
DemandManager:Thermostats Outputs
Group – Electric Load Center-Generator Specifications
ElectricLoadCenter:Transformer
Field: Availability Schedule Name
Field: Transformer Usage
Field: Zone Name
Field: Radiative Fraction
Field: Rated Capacity
Field: Phase
Field: Conductor Material
Field: Full Load Temperature Rise
Field: Fraction of Eddy Current Losses
Field: Performance Input Method
Field: Rated No Load Loss
Field: Rated Load Loss
Field: Nameplate Efficiency
Field: Per Unit Load for Nameplate Efficiency
Field: Reference Temperature for Nameplate Efficiency
Field: Per Unit Load for Maximum Efficiency
Field: Consider Transformer Loss for Utility Cost
Field: Electric Meter 1-10 Name
ElectricLoadCenter:Transformer Outputs
Transformer Efficiency
Transformer Output Electric Power [W]
Transformer Output Elecric Energy [J]
Transformer Input Electric Power [W]
Transformer Input Electric Energy [J]
Transformer No Load Loss Rate [W]
Transformer No Load Loss Energy [J]
Transformer Load Loss Rate [W]
Transformer Load Loss Energy [J]
Transformer Thermal Loss Rate [W]
Transformer Thermal Loss Energy [J]
Transformer Distribution Electric Loss Energy [J]
Transformer Cogeneration Electric Loss Energy [J]
ElectricLoadCenter:Distribution
Field: Name
Field: Generator List Name
Field: Generator Operation Scheme Type
Field: Demand Limit Scheme Purchased Electric Demand Limit
Field: Track Schedule Name Scheme Schedule Name
Field: Track Meter Scheme Meter Name
Field: Electrical Buss Type
Field: Inverter Object Name
Field: Electrical Storage Object Name
Field: Transformer Object Name
ElectricLoadCenter:Distribution Outputs
Facility Total Produced Electric Power [W]
Facility Total Produced Electric Energy [J]
Facility Total Purchased Electric Power [W]
Facility Total Purchased Electric Energy [J]
Facility Total Surplus Electric Energy [J]
Facility Total Building Electric Demand Power [W]
Facility Total HVAC Electric Demand Power [W]
Facility Total Electric Demand Power [W]
Facility Net Purchased Electric Power [W]
Facility Net Purchased Electric Energy [J]
Electric Load Center Requested Electric Power [W]
Electric Load Center Produced Electric Power [W]
Electric Load Center Produced Electric Energy [J]
Electric Load Center Produced Thermal Rate [W]
Electric Load Center Produced Thermal Energy [J]
ElectricLoadCenter:Generators
Field: Name
FieldSet: Name, Object Type, Rated Power Output, Availability, Thermal Ratio up to 30
Field: Generator Name
Field: Generator Object Type
Field: Generator Rated Electric Power Output
Field: Generator Availability Schedule Name
Field: Generator Rated Thermal to Electrical Power Ratio
ElectricLoadCenter:Generators Outputs
Generator Requested Electric Power [W]
ElectricLoadCenter:Inverter:Simple
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Radiative Fraction
Field: Inverter Efficiency
ElectricLoadCenter:Inverter:FunctionOfPower
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Radiative Fraction
Field: Efficiency Function of Power Curve Name
Field: Rated Maximum Continuous Input Power
Field: Minimum Efficiency
Field: Maximum Efficiency
Field: Minimum Power Output
Field: Maximum Power
Field: Ancillary Power Consumed In Standby
ElectricLoadCenter:Inverter:LookUpTable
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Radiative Fraction
Field: Rated Maximum Continuous Output Power
Field: Night Tare Loss Power
Field: Nominal Voltage Input
Field: Efficiency at 10% Power and Nominal Voltage
Field: Efficiency at 20% Power and Nominal Voltage
Field: Efficiency at 30% Power and Nominal Voltage
Field: Efficiency at 50% Power and Nominal Voltage
Field: Efficiency at 75% Power and Nominal Voltage
Field: Efficiency at 100% Power and Nominal Voltage
Electric Load Center Inverter Outputs
Inverter DC to AC Efficiency [ ]
Inverter DC Input Elecric Power [W]
Inverter DC Input Electric Energy [J]
Inverter AC Output Electric Power [W]
Inverter AC Output Electric Energy [J]
Inverter Thermal Loss Rate [W]
Inverter Thermal Loss Energy [J]
Inverter Ancillary AC Electric Power [W]
Inverter Ancillary AC Electric Energy [J]
ElectricLoadCenter:Storage:Simple
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Radiative Fraction for Zone Heat Gains
Field: Nominal Energetic Efficiency for Charging
Field: Nominal Discharging Energetic Efficiency
Field: Maximum Storage Capacity
Field: Maximum Power for Discharging
Field: Maximum Power for Charging
Field: Initial State of Charge
ElectricLoadCenter:Storage:Simple Outputs
Electric Storage Charge State [J]
Electric Storage Charge Power [W]
Electric Storage Charge Energy [J]
Electric Storage Production Decrement Energy [J]
Electric Storage Discharge Power [W]
Electric Storage Discharge Energy [J]
Electric Storage Thermal Loss Rate [W]
Electric Storage Thermal Loss Energy [J]
ElectricLoadCenter:Storage: Battery
Field: Name
Field: Availability Schedule Name
Field: Zone Name
Field: Radiative Fraction
Field: Number of Battery Modules in Parallel
Field: Number of Battery Modules in Series
Field: Maximum Module Capacity
Field: Initial Fractional State of Charge
Field: Fraction of Available Charge Capacity
Field: Change Rate from Bound Charge to Available Charge
Field: Fully Charged Module Open Circuit Voltage
Field: Fully Discharged Module Open Circuit Voltage
Field: Voltage Change Curve Name for Charging
Field: Voltage Change Curve Name for Discharging
Field: Module Internal Electrical Resistance
Field: Maximum Module Discharging Current
Field: Module Cut-off Voltage
Field: Module Charge Rate Limit
Field: Battery Life Calculation
Field: Number of Cycle Bins
Field: Battery Cycle Life Curve Name
ElectricLoadCenter: Storage:Battery Outputs
Electric Storage Operating Mode Index []
Electric Storage Charge State [Ah]
Electric Storage Charge Fraction []
Electric Storage Charge Power [W]
Electric Storage Charge Energy [J]
Electric Storage Production Decrement Energy [J]
Electric Storage Discharge Power [W]
Electric Storage Discharge Energy [J]
Electric Storage Total Current [A]
Electric Storage Total Voltage [V]
Electric Storage Thermal Loss Rate [W]
Electric Storage Thermal Loss Energy [J]
Electric Storage Degradation Fraction []
Generator:InternalCombustionEngine
Field: Name
Field: Rated Power Output
Field: Electric Circuit Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Shaft Power Curve Name
Field: Jacket Heat Recovery Curve Name
Field: Lube Heat Recovery Curve Name
Field: Total Exhaust Energy Curve Name
Field: Exhaust Temperature Curve Name
U-Factor Times Area (UA) Curve
Field: Coefficient 1 of U-Factor Times Area Curve
Field: Coefficient 2 of U-Factor Times Area Curve
Field: Maximum Exhaust Flow per Unit of Power Output
Field: Design Minimum Exhaust Temperature
Field: Fuel Higher Heating Value
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Inlet Node Name
Field: Heat Recovery Outlet Node Name
Field: Fuel Type
Field: Heat Recovery Maximum Temperature
Generator:InternalCombustionEngine Outputs
Generator Produced Electric Power [W]
Generator Produced Electric Energy [J]
Generator Lube Heat Recovery Rate [W]
Generator Lube Heat Recovery Energy [J]
Generator Jacket Heat Recovery Rate [W]
Generator Jacket Heat Recovery Energy [J]
Generator Exhaust Heat Recovery Rate [W]
Generator Exhaust Heat Recovery Energy [J]
Generator Produced Thermal Rate [W]
Generator Produced Thermal Energy [J]
Generator Exhaust Air Temperature [C]
Generator Heat Recovery Inlet Temperature [C]
Generator Heat Recovery Outlet Temperature [C]
Generator Heat Recovery Mass Flow Rate [kg/s]
Generator Fuel HHV Basis Rate [W]
Generator Fuel HHV Basis Energy [J]
Generator Rate [W]
Generator Energy [J]
Generator Mass Flow Rate [kg/s]
Generator:CombustionTurbine
Field: Name
Field: Rated Power Output
Field: Electric Circuit Node Name
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Part Load Based Fuel Input Curve Name
Field: Temperature Based Fuel Input Curve Name
Field: Exhaust Flow Curve Name
Field: Part Load Based Exhaust Temperature Curve Name
Field: Temperature Based Exhaust Temperature Curve Name
Field: Heat Recovery Lube Energy Curve Name
U-Factor Times Area (UA) Curve
Field: Coefficient 1 of U-Factor Times Area Curve
Field: Coefficient 2 of U-Factor Times Area Curve
Field: Maximum Exhaust Flow per Unit of Power Output
Field: Design Minimum Exhaust Temperature
Field: Design Air Inlet Temperature
Field: Fuel Higher Heating Value
Field: Design Heat Recovery Water Flow Rate
Field: Heat Recovery Inlet Node Name
Field: Heat Recovery Outlet Node Name
Field: Fuel Type
Field: Heat Recovery Maximum Temperature
Field: Outdoor Air Inlet Node Name
Generator:CombustionTurbine Outputs
Generator Rate [W]
Generator Energy [J]
Generator Mass Flow Rate [kg/s]
Generator:MicroTurbine
Field: Name
Field: Reference Electrical Power Output
Field: Minimum Full Load Electrical Power Output
Field: Maximum Full Load Electrical Power Output
Field: Reference Electrical Efficiency Using Lower Heating Value
Field: Reference Combustion Air Inlet Temperature
Field: Reference Combustion Air Inlet Humidity Ratio
Field: Reference Elevation
Field: Electrical Power Function of Temperature and Elevation Curve Name
Field: Electrical Efficiency Function of Temperature Curve Name
Field: Electrical Efficiency Function of Part Load Ratio Curve Name
Field: Fuel Type
Field: Fuel Higher Heating Value
Field: Fuel Lower Heating Value
Field: Standby Power
Field: Ancillary Power
Field: Ancillary Power Function of Fuel Input Curve Name
Field: Heat Recovery Water Inlet Node Name
Field: Heat Recovery Water Outlet Node Name
Field: Reference Thermal Efficiency Using Lower Heat Value
Field: Reference Inlet Water Temperature
Field: Heat Recovery Water Flow Operating Mode
Field: Reference Heat Recovery Water Flow Rate
Field: Heat Recovery Water Flow Rate Function of Temperature and Power Curve Name
Field: Thermal Efficiency Function of Temperature and Elevation Curve Name
Field: Heat Recovery Rate Function of Part Load Ratio Curve Name
Field: Heat Recovery Rate Function of Inlet Water Temperature Curve Name
Field: Heat Recovery Rate Function of Water Flow Rate Curve Name
Field: Minimum Heat Recovery Water Flow Rate
Field: Maximum Heat Recovery Water Flow Rate
Field: Maximum Heat Recovery Water Temperature
Field: Combustion Air Inlet Node Name
Field: Combustion Air Outlet Node Name
Field: Reference Exhaust Air Mass Flow Rate
Field: Exhaust Air Flow Rate Function of Temperature Curve Name
Field: Exhaust Air Flow Rate Function of Part Load Ratio Curve Name
Field: Nominal Exhaust Air Outlet Temperature
Field: Exhaust Air Temperature Function of Temperature Curve Name
Field: Exhaust Air Temperature Function of Part Load Ratio Curve Name
Generator:MicroTurbine Outputs
Generator Produced Electric Power [W]
Generator Produced Electric Energy [J]
Generator LHV Basis Electric Efficiency []
Generator HHV Basis Rate [W]
Generator Fuel HHV Basis Rate [W]
Generator HHV Basis Energy [J]
Generator Fuel HHV Basis Energy [J]
Generator Mass Flow Rate [kg/s]
Generator Standby Electric Power [W]
Generator Standby Electric Energy [J]
Generator Ancillary Electric Power [W]
Generator Ancillary Electric Energy [J]
Generator Produced Thermal Rate [W]
Generator Produced Thermal Energy [J]
Generator Thermal Efficiency LHV Basis [-]
Generator Heat Recovery Inlet Temperature [C]
Generator Heat Recovery Outlet Temperature [C]
Generator Heat Recovery Water Mass Flow Rate [kg/s]
Generator Exhaust Air Mass Flow Rate [kg/s]
Generator Exhaust Air Temperature [C]
Generator:MicroCHP
Field: Name
Field: Performance Parameters Name
Field: Zone Name
Field: Cooling Water Inlet Node Name
Field: Cooling Water Outlet Node Name
Field: Air Inlet Node Name
Field: Air Outlet Node Name
Field: Generator Fuel Supply Name
Field: Availability Schedule Name
Generator:MicroCHP:NonNormalizedParameters
Field: Name
Field: Maximum Electric Power
Field: Minimum Electric Power
Field: Minimum Cooling Water Flow Rate
Field: Maximum Cooling Water Temperature
Field: Electrical Efficiency Curve Name
Field: Thermal Efficiency Curve Name
Field: Cooling Water Flow Rate Mode
Field: Cooling Water Flow Rate Curve Name
Field: Air Flow Rate Curve Name
Field: Maximum Net Electrical Power Rate of Change
Field: Maximum Fuel Flow Rate of Change
Field: Heat Exchanger U-Factor Times Area Value
Field: Skin Loss U-Factor Times Area Value
Field: Skin Loss Radiative Fraction
Field: Aggregated Thermal Mass of Energy Conversion Portion of Generator
Field: Aggregated Thermal Mass of Heat Recovery Portion of Generator
Field: Standby Power
Field: Warm Up Mode
Field: Warm Up Fuel Flow Rate Coefficient
Field: Nominal Engine Operating Temperature
Field: Warm Up Power Coefficient
Field: Warm Up Fuel Flow Rate Limit Ratio
Field: Warm Up Delay Time
Field: Cool Down Power
Field: Cool Down Delay Time
Field: Restart Mode
Generator:MicroCHP Outputs
Generator Off Mode Time [s]
Generator Standby Mode Time [s]
Generator Warm Up Mode Time [s]
Generator Normal Operating Mode Time [s]
Generator Cool Down Mode Time [s]
Generator Produced Electric Power [W]
Generator Produced Electric Energy [J]
Generator Electric Efficiency [ ]
Generator Thermal Efficiency [ ]
Generator Gross Input Heat Rate [W]
Generator Steady State Engine Heat Generation Rate [W]
Generator Engine Heat Exchange Rate [W]
Generator Produced Thermal Rate [W]
Generator Produced Thermal Energy [J]
Generator Air Mass Flow Rate [kg/s]
Generator Fuel Molar Flow Rate [kmol/s]
Generator Fuel Mass Flow Rate [kg/s]
Generator Engine Temperature [C]
Generator Coolant Inlet Temperature [C]
Generator Coolant Outlet Temperature [C]
Generator Fuel HHV Basis Energy [J]
Generator Fuel HHV Basis Rate [W]
Generator Fuel LHV Basis Energy [J]
Generator Fuel LHV Basis Rate [W]
Generator Zone Sensible Heat Transfer Rate [W]
Generator Zone Sensible Heat Transfer Energy [J]
Generator Zone Convection Heat Transfer Rate [W]
Generator Zone Radiation Heat Transfer Rate [W]
Generator:FuelCell
Field: Name
Field: Power Module Name
Field: Air Supply Name
Field: Fuel Supply Name
Field: Water Supply Name
Field: Auxiliary Heater Name
Field: Heat Exchanger Name
Field: Electrical Storage Name
Field: Inverter Name
Field: Stack Cooler Name
Generator:FuelCell Outputs
Generator Produced Electric Power [W]
Generator Produced Electric Energy [J]
Generator Produced Thermal Rate [W]
Generator Produced Thermal Energy [J]
Generator Fuel HHV Basis Energy [J]
Generator Fuel HHV Basis Rate [W]
Generator Fuel LHV Basis Energy [J]
Generator Fuel Consumption Rate LHV Basis [W]
Generator Zone Sensible Heat Transfer Rate [W]
Generator Zone Sensible Heat Transfer Energy [J]
Generator Zone Convection Heat Transfer Rate [W]
Generator Zone Radiation Heat Transfer Rate [W]
Generator Air Inlet Temperature [C]
Generator Power Module Entering Air Temperature [C]
Generator Air Molar Flow Rate [kmol/s]
Generator Power Module Entering Air Enthalpy [W]
Generator Blower Electric Power [W]
Generator Blower Electric Energy [J]
Generator Blower Skin Heat Loss Rate [W]
Generator Fuel Inlet Temperature [C]
Generator Power Module Entering Fuel Temperature [C]
Generator Fuel Molar Flow Rate [kmol/s]
Generator Power Module Entering Fuel Enthalpy [W]
Generator Fuel Compressor Electric Power [W]
Generator Fuel Compressor Electric Energy [J]
Generator Fuel Compressor Skin Heat Loss Rate [W]
Generator Fuel Reformer Water Inlet Temperature [C]
Generator Power Module Entering Reforming Water Temperature [C]
Generator Fuel Reformer Water Molar Flow Rate [kmol/s]
Generator Fuel Reformer Water Pump Electric Power [W]
Generator Fuel Reformer Water Pump Electric Energy [J]
Generator Power Module Entering Reforming Water Enthalpy [W]
Generator Product Gas Temperature [C]
Generator Product Gas Enthalpy [W]
Generator Product Gas Molar Flow Rate [kmol/s]
Generator Product Gas Ar Molar Flow Rate [kmol/s]
Generator Product Gas CO2 Molar Flow Rate [kmol/s]
Generator Product Gas H2O Vapor Molar Flow Rate [kmol/s]
Generator Product Gas N2 Molar Flow Rate [kmol/s]
Generator Product Gas O2 Molar Flow Rate [kmol/s]
Generator Inverter Loss Power [W]
Generator Produced DC Electric Power [W]
Generator DC Power Efficiency [ ]
Generator Electric Storage Charge State [J]
Generator Produced DC Electric Power [W]
Generator DC Storage Charging Energy [J]
Generator DC Storage Discharging Power [W]
Generator DC Storage Discharging Energy [J]
Generator Ancillary AC Electric Power [W]
Generator Ancillary AC Electric Energy [J]
Generator Fuel Cell Model Iteration Count [ ]
Generator Regula Falsi Iteration Count [ ]
Generator Heat Recovery Exit Gas Temperature [C]
Generator Heat Recovery Exit Gas H2O Vapor Fraction []
Generator Heat Recovery Water Condensate Molar Flow Rate [kmol/s]
Generator:FuelCell:PowerModule
Field: Name
Field: Efficiency Curve Mode
Field: Efficiency Curve Name
Field: Nominal Efficiency
Field: Nominal Electrical Power
Field: Number of Stops at Start of Simulation
Field: Cycling Performance Degradation Coefficient
Field: Number of Run Hours at Beginning of Simulation
Field: Accumulated Run Time Degradation Coefficient
Field: Run Time Degradation Initiation Time Threshold
Field: Power Up Transient Limit
Field: Power Down Transient Limit
Field: Start Up Time
Field: Start Up Fuel
Field: Start Up Electricity Consumption
Field: Start Up Electricity Produced
Field: Shut Down Time
Field: Shut Down Fuel
Field: Shut Down Electricity Consumption
Field: Ancilliary Electricity Constant Term
Field: Ancilliary Electricity Linear Term
Field: Skin Loss Calculation Mode
Field: Zone Name
Field: Skin Loss Radiative Fraction
Field: Constant Skin Loss Rate
Field: Skin Loss U-Factor Times Area Term
Field: Skin Loss Quadratic Curve Name
Field: Dilution Air Flow Rate
Field: Stack Heat loss to Dilution Air
Field: Dilution Inlet Air Node Name
Field: Dilution Outlet Air Node Name
Field: Minimum Operating Point
Field: Maximum Operating Point
Generator:FuelCell:StackCooler
Field: Name
Field: Heat Recovery Water Inlet Node Name
Field: Heat Recovery Water Outlet Node Nane
Field: Nominal Stack Temperature
[Field: Actual Stack Temperature]](page-055.html#field-actual-stack-temperature)
Field: Coefficient r0
Field: Coefficient r1
Field: Coefficient r2
Field: Coefficient r3
Field: Stack Coolant Flow Rate
Field: Stack Cooler U-Factor Times Area Value
Field: Fs-cogen Adjustment Factor
Field: Stack Cogeneration Exchanger Area
Field: Stack Cogeneration Exchanger Nominal Flow Rate
Field: Stack Cogeneration Exchanger Nominal Heat Transfer Coefficient
Field: Stack Cogeneration Exchanger Nominal Heat Transfer Coefficient Exponent
Field: Stack Cooler Pump Power
Field: Stack Cooler Pump Heat loss
Field: Stack Air Cooler Fan Coefficient f0
Field: Stack Air Cooler Fan Coefficient f1
Field: Stack Air Cooler Fan Coefficient f2
Generator:FuelCell:AirSupply
Field: Name
Field: Air Inlet Node Name
Field: Blower Power Curve Name
Field: Blower Heat Loss Factor
Field: Air Supply Rate Calculation Mode
Field: Stoichiometric Ratio
Field: Air Rate Function of Electric Power Curve Name
Field: Air Rate Air Temperature Coefficient
Field: Air Rate Function of Fuel Rate Curve Name
Field: Air Intake Heat Recovery Mode
Field: Air Supply Constituent Mode
Field: Number of UserDefined Constituents
Field: Constituent 1-5 Name
Field: Molar Fraction 1-5
Generator:FuelCell:WaterSupply
Field: Name
Field: Reformer Water Flow Rate Function of Fuel Rate Curve Name
Field: Reformer Water Pump Power Function of Fuel Rate Curve Name
Field: Pump Heat Loss Factor
Field: Water Temperature Modeling Mode
Field: Water Temperature Reference Node Name
Field: Water Temperature Schedule Name
Generator:FuelCell:AuxiliaryHeater
Field: Name
Field: Excess Air Ratio
Field: Ancillary Power Constant Term
Field: Ancillary Power Linear Term
Field: Skin Loss U-Factor Times Area Value
Field: Skin Loss Destination
Field: Zone Name to Receive Skin Losses
Field: Heating Capacity Units
Field: Maximum Heating Capacity in Watts
Field: Minimum Heating Capacity in Watts
Field: Maximum Heating Capacity in Kmol per Second
Field: Minimum Heating Capacity in Kmol per Second
Field: Name
Field: Heat Recovery Water Inlet Node Name
Field: Heat Recovery Water Outlet Node Name
Field: Heat Recovery Water Maximum Flow Rate
Field: Exhaust Outlet Air Node Name
Field: Heat Exchanger Calculation Method
Field: Method 1 Heat Exchanger Effectiveness
Field: Method 2 Parameter hxs0
Field: Method 2 Parameter hxs1
Field: Method 2 Parameter hxs2
Field: Method 2 Parameter hxs3
Field: Method 2 Parameter hxs4
Field: Method 3 h0Gas Coefficient
Field: Method 3 NdotGasRef Coefficient
Field: Method 3 n Coefficient
Field: Method 3 Gas Area
Field: Method 3 h0 Water Coefficient
Field: Method 3 N dot Water ref Coefficient
Field: Method 3 m Coefficient
Field: Method 3 Area Water Coefficient
Field: Method 3 F Adjustment Factor
Field: Method 4 hxl1 Coefficient
Field: Method 4 hxl2 Coefficient
Field: Method 4 Condensation Threshold
Generator:FuelCell:ElectricalStorage
Field: Name
Field: Choice of Model
Field: Nominal Charging Energetic Efficiency
Field: Nominal Discharging Energetic Efficiency
Field: Simple Maximum Capacity
Field: Simple Maximum Power Draw
Field: Simple Maximum Power Store
Field: Initial Charge State
Generator:FuelCell:Inverter
Field: Name
Field: Inverter Efficiency Calculation Mode
Field: Inverter Efficiency
Field: Efficiency Function of DC Power Curve Name
Generator:FuelSupply
Field: Name
Field: Fuel Temperature Modeling Mode
Field: Fuel Temperature Reference Node Name
Field: Fuel Temperature Schedule Name
Field: Compressor Power Function of Fuel Rate Curve Name
Field: Compressor Heat Loss Factor
Field: Fuel Type
Field: Liquid Generic Fuel Lower Heating Value
Field: Liquid Generic Fuel Higher Heating Value
Field: Liquid Generic Fuel Molecular Weight
Field: Liquid Generic Fuel CO2 Emission Factor
Field: Number of Constituents in Gaseous Constituent Fuel Supply
Field: Constituent 1-12 Name
Field: Constituent 1-12 Molar Fraction
Generator:FuelSupply Outputs
Generator Fuel Compressor Electric Power [W]
Generator Fuel Compressor Electric Energy [J]
Generator Fuel Compressor Skin Heat Loss Rate [W]
Photovoltaic Generators
Generator:Photovoltaic
Field: Name
Field: Surface Name
Field: Photovoltaic Performance Object Type
Field: Module Performance Name
Field: Heat Transfer Integration Mode
Field: Number of Series Strings in Parallel
Field: Number of Modules in Series
Generator:Photovoltaic Outputs
Generator Produced DC Electric Power [W]
Generator Produced DC Electric Energy [J]
Generator PV Array Efficiency [ ]
Generator PV Cell Temperature [°C]
Generator PV Short Circuit Current [A]
Generator PV Open Circuit Voltage [V]
PhotovoltaicPerformance:Simple
Field: Name
Field: Fraction of Surface Area with Active Solar Cells
Field: Conversion Efficiency Input Mode
Field: Value for Cell Efficiency if Fixed
Field: Efficiency Schedule Name
PhotovoltaicPerformance:EquivalentOne-Diode
Field: Name
Field: Cell Type
Field: Number of Cells in Series
Field: Active Area
Field: Transmittance Absorptance Product
Field: Semiconductor Bandgap
Field: Shunt Resistance
Field: Short Circuit Current
Field: Open Circuit Voltage
Field: Reference Temperature
Field: Reference Insolation
Field: Module Current at Maximum Power
Field: Module Voltage at Maximum Power
Field: Temperature Coefficient of Short Circuit Current
Field: Temperature Coefficient of Open Circuit Voltage
Field: Nominal Operating Cell Temperature Test Ambient Temperature
Field: Nominal Operating Cell Temperature Test Cell Temperature
Field: Nominal Operating Cell Temperature Test Insolation
Field: Module Heat Loss Coefficient
Field: Total Heat Capacity
PhotovoltaicPerformance:Sandia
Field: Name
Field: Active Area
Field: Number of Cells in Series
Field: Number of Cells in Parallel
Field: Short-Circuit Current
Field: Open-Circuit Voltage
Field: Current at Maximum Power Point
Field: Voltage at Maximum PowerPoint
Field: Sandia Database Parameter aIsc
Field: Sandia Database Parameter aImp
Field: Sandia Database Parameter c0
Field: Sandia Database Parameter c1
Field: Sandia Database Parameter Bvoc0
Field: Sandia Database Parameter mBVoc
Field: Sandia Database Parameter BVmp0
Field: Sandia Database Parameter mBVmp
Field:Diode Factor
Field: Sandia Database Parameter c2
Field: Sandia Database Parameter c3
Field: Sandia Database Parameter a0
Field: Sandia Database Parameter a1
Field: Sandia Database Parameter a2
Field: Sandia Database Parameter a3
Field: Sandia Database Parameter a4
Field: Sandia Database Parameter b0
Field: Sandia Database Parameter b1
Field: Sandia Database Parameter b2
Field: Sandia Database Parameter b3
Field: Sandia Database Parameter b4
Field: Sandia Database Parameter b5
Field: Sandia Database Parameter Delta(TC)
Field: Sandia Database Parameter fd
Field: Sandia Database Parameter a
Field: Sandia Database Parameter b
Field: Sandia Database Parameter c4
Field: Sandia Database Parameter c5
Field: Sandia Database Parameter Ix0
Field: Sandia Database Parameter Ixx0
Field: Sandia Database Parameter c6
Field: Sandia Database Parameter c7
Generator:WindTurbine
Field: Name
Field: Availability Schedule Name
Field: Rotor Type
Field: Power Control
Field: Rated Rotor Speed
Field: Rotor Diameter
Field: Overall Height
Field: Number of Blades
Field: Rated Power
Field: Rated Wind Speed
Field: Cut In Wind Speed
Field: Cut Out Wind Speed
Field: Fraction System Efficiency
Field: Maximum Tip Speed Ratio
Field: Maximum Power Coefficient
Field: Annual Local Average Wind Speed
Field: Height for Local Average Wind Speed
Field: Blade Chord Area
Field: Blade Drag Coefficient
Field: Blade Lift Coefficient
Field: Power Coefficient Parameter
Generator:WindTurbine Outputs
Generator Produced Electric Power [W]
Generator Produced Electric Energy [J]
Generator Turbine Local Wind Speed [m/s]
Generator Turbine Local Air Density [kg/m3]
Generator Turbine Tip Speed Ratio []
Generator Turbine Power Coefficient []
Generator Turbine Chordal Component Velocity [m/s]
Generator Turbine Normal Component Velocity [m/s]
Generator Turbine Relative Flow Velocity [m/s]
Generator Turbine Attack Angle [deg]
Group – Water Systems
WaterUse:Equipment
Field: Name
Field: End-Use Subcategory
Field: Peak Flow Rate
Field: Flow Rate Fraction Schedule Name
Field: Target Temperature Schedule Name
Field: Hot Water Supply Temperature Schedule Name
Field: Cold Water Supply Temperature Schedule Name
Field: Zone Name
Field: Sensible Fraction Schedule Name
Field: Latent Fraction Schedule Name
WaterUse:Equipment Outputs
Water Use Equipment Hot Water Mass Flow Rate [kg/s]
Water Use Equipment Cold Water Mass Flow Rate [kg/s]
Water Use Equipment Total Mass Flow Rate [kg/s]
Water Use Equipment Hot Water Volume Flow Rate [m3/s]
Water Use Equipment Cold Water Volume Flow Rate [m3/s]
Water Use Equipment Total Volume Flow Rate [m3/s]
Water Use Equipment Hot Water Volume [m3]
Water Use Equipment Cold Water Volume [m3]
Water Use Equipment Total Volume [m3]
Water Use Equipment Mains Water Volume [m3]
Water Use Equipment Hot Water Temperature [C]
Water Use Equipment Cold Water Temperature [C]
Water Use Equipment Target Water Temperature [C]
Water Use Equipment Mixed Water Temperature [C]
Water Use Equipment Drain Water Temperature [C]
Water Use Equipment Heating Rate [W]
Water Use Equipment Heating Energy [J]
Water Use Equipment Zone Sensible Heat Gain Rate [W]
Water Use Equipment Zone Sensible Heat Gain Energy [J]
Water Use Equipment Zone Latent Gain Rate [W]
Water Use Equipment Zone Latent Gain Energy [J]
Water Use Equipment Zone Moisture Gain Mass Flow Rate [kg/s]
Water Use Equipment Zone Moisture Gain Mass [kg]
WaterUse:Connections
Field: Name
Field: Inlet Node Name
Field: Outlet Node Name
Field: Supply Water Storage Tank Name
Field: Reclamation Water Storage Tank Name
Field: Hot Water Supply Temperature Schedule Name
Field: Cold Water Supply Temperature Schedule Name
Field: Drain Water Heat Exchanger Type
Field: Drain Water Heat Exchanger Destination
Field: Drain Water Heat Exchanger U-Factor Times Area
Field: Water Use Equipment 1-10 Name
WaterUse:Connections Outputs
Water Use Connections Hot Water Mass Flow Rate [kg/s]
Water Use Connections Cold Water Mass Flow Rate [kg/s]
Water Use Connections Total Mass Flow Rate [kg/s]
Water Use Connections Drain Water Mass Flow Rate [kg/s]
Water Use Connections Heat Recovery Mass Flow Rate [kg/s]
Water Use Connections Hot Water Volume Flow Rate [m3/s]
Water Use Connections Cold Water Volume Flow Rate [m3/s]
Water Use Connections Total Volume Flow Rate [m3/s]
Water Use Connections Hot Water Volume [m3]
Water Use Connections Cold Water Volume [m3]
Water Use Connections Total Volume [m3]
Water Use Connections Hot Water Temperature [C]
Water Use Connections Cold Water Temperature [C]
Water Use Connections Drain Water Temperature [C]
Water Use Connections Return Water Temperature [C]
Water Use Connections Waste Water Temperature [C]
Water Use Connections Heat Recovery Water Temperature [C]
Water Use Connections Heat Recovery Effectiveness []
Water Use Connections Heat Recovery Rate [W]
Water Use Connections Heat Recovery Energy [J]
Water Use Connections Plant Hot Water Energy [J]
WaterUse:Storage
Field: Name
Field: Water Quality Subcategory
Field: Maximum Capacity
Field: Initial Volume
Field: Design In Flow Rate
Field: Design Out Flow Rate
Field: Overflow Destination
Field: Type of Supply Controlled by Float Valve
Field: Float Valve On Capacity
Field: Float Valve Off Capacity
Field: Backup Mains Capacity
Field: Other Tank Name
Field: Water Thermal Mode
Field: Water Temperature Schedule Name
Field: Ambient Temperature Indicator
Field: Ambient Temperature Schedule Name
Field: Zone Name
Field: Tank Surface Area
Field: Tank U Value
Field: Tank Outside Surface Material Name
WaterUse:Storage Outputs
Water System Storage Tank Volume [m3]
Water System Storage Tank Net Volume Flow Rate [m3]
Water System Storage Tank Inlet Volume Flow Rate [m3/s]
Water System Storage Tank Outlet Volume Flow Rate [m3]
Water System Storage Tank Mains Water Volume [m3]
Water System Storage Tank Mains Water Volume Flow Rate [m3/s]
Water System Storage Tank Water Temperature [C]
Water System Storage Tank Overflow Volume Flow Rate [m3/s]
Water System Storage Tank Overflow Water Volume [m3]
Water System Storage Tank Overflow Temperature [C]
WaterUse:RainCollector
Field: Name
Field: Storage Tank Name
Field: Loss Factor Mode
Field: Collection Loss Factor
Field: Collection Loss Factor Schedule Name
Field: Maximum Collection Rate
Field: Collection Surface 1-10 Name
WaterUse:RainCollector Outputs
Water System Rainwater Collector Volume Flow Rate [m3/s]
Water System Rainwater Collector Volume [m3]
WaterUse:Well
Field: Name
Field: Storage Tank Name
Field: Pump Depth
Field: Pump Rated Flow Rate
Field: Pump Rated Head
Field: Pump Rated Power Consumption
Field: Pump Efficiency
Field: Well Recovery Rate
Field: Nominal Well Storage Volume
Field: Water Table Depth Mode
Field: Water Table Depth
Field: Water Table Depth Schedule Name
WaterUse:Well Outputs
Water System Groundwater Well Requested Volume Flow Rate [m3/s]
Water System Groundwater Well Volume Flow Rate [m3/s]
Water System Groundwater Well Volume [m3]
Water System Groundwater Well Pump Electric Power [W]
Water System Groundwater Well Pump Electric Energy [J]
Group – Performance Curves
Curve:Linear
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Output Unit Type
Curve:QuadLinear
y = C1 + C2 * w + C3 * x + C4 * y + C5 * z
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 w
Field: Coefficient3 x
Field: Coefficient4 y
Field: Coefficient5 z
Field: Minimum Value of w
Field: Maximum Value of w
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Value of y
Field: Maximum Value of y
Field: Minimum Value of z
Field: Maximum Value of z
Field: Input Unit Type for w
Field: Input Unit Type for x
Field: Input Unit Type for y
Field: Input Unit Type for z
Curve:Quadratic
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Output Unit Type
Curve:Cubic
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Coefficient4 x**3
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Output Unit Type
Curve:Quartic
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Coefficient4 x**3
Field: Coefficient5 x**4
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Value of x
Field: Input Unit Type for X
Field: Output Unit Type
Curve:Exponent
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 Constant
Field: Coefficient3 Constant
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Output Unit Type
Curve:Bicubic
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Coefficient4 y
Field: Coefficient5 y**2
Field: Coefficient6 x*y
Field: Coefficient7 x**3
Field: Coefficient8 y**3
Field: Coefficient9 x**2*y
Field: Coefficient10 x*y**2
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Value of y
Field: Maximum Value of y
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Input Unit Type for Y
Field: Output Unit Type
Curve:Biquadratic
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Coefficient4 y
Field: Coefficient5 y**2
Field: Coefficient6 x*y
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Value of y
Field: Maximum Value of y
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Input Unit Type for Y
Field: Output Unit Type
Curve:QuadraticLinear
Field: Name
Field: Coefficient1 Constant
Field: Coefficient2 x
Field: Coefficient3 x**2
Field: Coefficient4 y
Field: Coefficient5 x*y
Field: Coefficient6 x**2*y
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Value of y
Field: Maximum Value of y
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Input Unit Type for Y
Field: Output Unit Type
Curve:Triquadratic
Field: Coefficient1 Constant
Field: Coefficient2 x**2
Field: Coefficient3 x
Field: Coefficient4 y**2
Field: Coefficient5 y
Field: Coefficient6 z**2
Field: Coefficient7 z
Field: Coefficient8 x**2*y**2
Field: Coefficient9 x*y
Field: Coefficient10 x*y**2
Field: Coefficient11 x**2*y
Field: Coefficient12 x**2*z**2
Field: Coefficient13 x*z
Field: Coefficient14 x*z**2
Field: Coefficient15 x**2*z
Field: Coefficient16 y**2*z**2
Field: Coefficient17 y*z
Field: Coefficient18 y*z**2
Field: Coefficient19 y**2*z
Field: Coefficient20 x**2*y**2*z**2
Field: Coefficient21 x**2*y**2*z
Field: Coefficient22 x
2
y
z
2
Field: Coefficient23 x*y**2*z**2
Field: Coefficient24 x**2
y
z
Field: Coefficient25 x*y**2*z
Field: Coefficient26 x
y
z**2
Field: Coefficient27 x
y
z
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Value of y
Field: Maximum Value of y
Field: Minimum Value of z
Field: Maximum Value of z
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X
Field: Input Unit Type for Y
Field: Input Unit Type for Z
Field: Output Unit Type
Curve:Functional:PressureDrop
Field: Name
Field: Diameter
Field: Minor Loss Coefficient
Field: Length
Field: Roughness
Field: Fixed Friction Factor
Curve:FanPressureRise
Field: Name
Field: Fan Pressure Rise Coefficient1 C1
Field: Fan Pressure Rise Coefficient2 C2
Field: Fan Pressure Rise Coefficient3 C3
Field: Fan Pressure Rise Coefficient4 C4
Field: Minimum Value of Qfan
Field: Maximum Value of Qfan
Field: Minimum Value of Psm
Field: Maximum Value of Psm
Field: Minimum Curve Output
Field: Maximum Curve Output
Curve:ExponentialSkewNormal
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Coefficient4 C4
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Curve:Sigmoid
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Coefficient4 C4
Field: Coefficient5 C5
Fi eld: Minimum Value of x”field-maximum-value-of-x-12
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Curve:RectangularHyperbola1
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Curve:RectangularHyperbola2
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Curve:ExponentialDecay
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Curve:DoubleExponentialDecay
Field: Name
Field: Coefficient1 C1
Field: Coefficient2 C2
Field: Coefficient3 C3
Field: Coefficient4 C4
Field: Coefficient5 C5
Field: Minimum Value of x
Field: Maximum Value of x
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for x
Field: Output Unit Type
Performance Curve Outputs
Performance Curve Output Value
Performance Curve Input Variable 1(-N) Value []
Group – Performance Tables
Table:OneIndependentVariable
Field: Name
Field: Curve Type
Field: Interpolation Method
Field: Minimum Value of X
Field: Maximum Value of X
Field: Minimum Table Output
Field: Maximum Table Output
Field: Input Unit Type for X1
Field: Output Unit Type
Field: Normalization Reference
Data Pairs
Field: X Value #n
Field: Output Value #n
Performance Table Outputs
Performance Curve Output Value []
Performance Curve Input Variable 1 Value []
Table:TwoIndependentVariables
Field: Name
Field: Curve Type
Field: Interpolation Method
Field: Minimum Value of X
Field: Maximum Value of X
Field: Minimum Value of Y
Field: Maximum Value of Y
Field: Minimum Table Output
Field: Maximum Table Output
Field: Input Unit Type for X
Field: Input Unit Type for Y
Field: Output Unit Type
Field: Normalization Reference
Data Pairs
Field: X Value #n
Field: Y Value #n
Field: Output Value #n
Two Independent Variable Performance Table Outputs
Performance Curve Output Value []
Performance Curve Input Variable 1 Value []
Performance Curve Input Variable 2 Value []
Lookup Tables
Table:MultiVariableLookup
Field: Name
Field: Curve Type
Field: Interpolation Method
Field: Table Data Format
Field: Number of Interpolation Points
Field: External File Name
Field: X1 Sort Order
Field: X2 Sort Order
Field: Minimum Value of X1
Field: Maximum Value of X1
Field: Minimum Value of X2
Field: Maximum Value of X2
Field: Minimum Value of X3
Field: Maximum Value of X3
Field: Minimum Value of X4
Field: Maximum Value of X4
Field: Minimum Value of X5
Field: Maximum Value of X5
Field: Minimum Curve Output
Field: Maximum Curve Output
Field: Input Unit Type for X1
Field: Input Unit Type for X2
Field: Input Unit Type for X3
Field: Input Unit Type for X4
Field: Input Unit Type for X5
Field: Ou tput Unit Type”data-input-format
Field: Field #1 (NumberOfIndependentVariables)
Field: Field #2 (NumberOfValuesForIndependentVariable1)
Field: Field #3 (DeterminedByPreviousFields)
Field: Field #4
Lookup Table Outputs
Lookup Table Outputs
Performance Curve Output Value []
Performance Curve Input Variable 1(-N) Value []
Group – Fluid Properties
FluidProperties:Name
Field: Fluid Name
Field: Fluid Type
FluidProperties:GlycolConcentration
Field: Name
Field: Glycol Type
Field: User Defined Glycol Name
Field: Glycol Concentration
FluidProperties:Temperatures
Field: Name
Field(s) 1-250: Temperature
FluidProperties:Saturated
Field: Name
Field: Fluid Property Type
Field: Fluid Phase
Field: Temperatures Values Name
Field(s) 1-250: Property Value
FluidProperties:Superheated
Field: Fluid Name
Field: Fluid Property Type
Field: Temperatures Values Name
Field: Pressure
Field(s) 1-250: Property Value
Glycol Fluid Types
FluidProperties:Concentration
Field: Fluid Name
Field: Fluid Property Type
Field: Temperatures Values Name
Field: Concentration
Field(s) 1-250: Property Value
HVAC Template Objects
HVACTemplate Processing
Group – HVAC Templates
HVACTemplate:Thermostat
Field: Name
Field: Heating Setpoint Schedule Name
Field: Constant Heating Setpoint
Field: Cooling Setpoint Schedule Name
Field: Constant Cooling Setpoint
HVACTemplate:Zone:IdealLoadsAirSystem
Field: Zone Name
Field: Template Thermostat Name
HVACTemplate:Zone:FanCoil
Field: Zone Name
Field: Template Thermostat Name
Field: Supply Air Maximum Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: System Availability Schedule Name
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Design Setpoint
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Coil Design Setpoint
Field: Dedicated Outdoor Air System Name
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature Difference
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:PTAC
Field: Zone Name
Field: Template Thermostat Name
Field: Cooling Supply Air Flow Rate
Field: Heating Supply Air Flow Rate
Field: No Load Supply Air Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: System Availability Schedule Name
Field: Supply Fan Operating Mode Schedule Name
Field: Supply Fan Placement
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Rated Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Coil Capacity
Field: Gas Heating Coil Efficiency
Field: Gas Heating Coil Parasitic Electric Load
Field: Dedicated Outdoor Air System Name
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:PTHP
Field: Zone Name
Field: Template Thermostat Name
Field: Cooling Supply Air Flow Rate
Field: Heating Supply Air Flow Rate
Field: No Load Supply Air Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: System Availability Schedule Name
Field: Supply Fan Operating Mode Schedule Name
Field: Supply Fan Placement
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Rated Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heat Pump Heating Coil Type
Field: Heat Pump Heating Coil Availability Schedule Name
Field: Heat Pump Heating Coil Rated Capacity
Field: Heat Pump Heating Coil Rated COP
Field: Heat Pump Heating Minimum Outdoor Dry-Bulb Temperature
Field: Heat Pump Defrost Maximum Outdoor Dry-Bulb Temperature
Field: Heat Pump Defrost Strategy
Field: Heat Pump Defrost Control
Field: Heat Pump Defrost Time Period Fraction
Field: Supplemental Heating Coil Type
Field: Supplemental Heating Coil Availability Schedule Name
Field: Supplemental Heating Coil Capacity
Field: Supplemental Heating Coil Maximum Outdoor Dry-Bulb Temperature
Field: Supplemental Gas Heating Coil Efficiency
Field: Supplemental Gas Heating Coil Parasitic Electric Load
Field: Dedicated Outdoor Air System Name
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:Unitary
Field: Zone Name
Field: Template Unitary System Name
Field: Template Thermostat Name
Field: Supply Air Maximum Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Baseboard Heating Type
Field: Baseboard Heating Availability Schedule Name
Field: Baseboard Heating Capacity
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:VAV
Field: Zone Name
Field: Template VAV System Name
Field: Template Thermostat Name
Field: Supply Air Maximum Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Zone Minimum Air Flow Method
Field: Constant Minimum Air Flow Fraction
Field: Fixed Minimum Air Flow Rate
Field: Minimum Air Flow Fraction Schedule Name
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: Reheat Coil Type
Field: Reheat Coil Availability Schedule Name
Field: Damper Heating Action
Control Fields for Maximum Flow During Reheat:
Field: Maximum Flow per Zone Floor Area During Reheat
Field: Maximum Flow Fraction During Reheat
Field: Maximum Reheat Air Temperature
Field: Design Specification Outdoor Air Object Name for Control
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Baseboard Heating Type
Field: Baseboard Heating Availability Schedule Name
Field: Baseboard Heating Capacity
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Design Specification Outdoor Air Object Name for Sizing
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:VAV:FanPowered
Field: Zone Name
Field: Template VAV System Name
Field: Template Thermostat Name
Field: Primary Supply Air Maximum Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Primary Supply Air Minimum Flow Fraction
Field: Secondary Supply Air Maximum Flow Rate
Field: Flow Type
Field: Parallel Fan On Flow Fraction
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: Reheat Coil Type
Field: Reheat Coil Availability Schedule Name
Field: Fan Total Efficiency
Field: Fan Delta Pressure
Field: Fan Motor Efficiency
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Baseboard Heating Type
Field: Baseboard Heating Availability Schedule Name
Field: Baseboard Heating Capacity
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Zone PIU Fan Schedule Name
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:Zone:WaterToAirHeatPump
Field: Zone Name
Field: Template Thermostat Name
Field: Cooling Supply Air Flow Rate
Field: Heating Supply Air Flow Rate
Field: No Load Supply Air Flow Rate
Field: Zone Heating Sizing Factor
Field: Zone Cooling Sizing Factor
Field: Outdoor Air Method
Field: Outdoor Air Flow Rate per Person
Field: Outdoor Air Flow Rate per Zone Floor Area
Field: Outdoor Air Flow Rate per Zone
Field: System Availability Schedule Name
Field: Supply Fan Operating Mode Schedule Name
Field: Supply Fan Placement
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Cooling Coil Type
Field: Cooling Coil Rated Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heat Pump Heating Coil Type
Field: Heat Pump Heating Coil Rated Capacity
Field: Heat Pump Heating Coil Rated COP
Field: Supplemental Heating Coil Availability Schedule Name
Field: Supplemental Heating Coil Capacity
Field: Maximum Cycling Rate
Field: Heat Pump Time Constant
Field: Fraction of On-Cycle Power Use
Field: Heat Pump Fan Delay Time
Field: Dedicated Outdoor Air System Name
Field: Supplemental Heating Coil Type
Field: Zone Cooling Design Supply Air Temperature Input Method
Field: Zone Cooling Design Supply Air Temperature
Field: Zone Cooling Design Supply Air Temperature Difference
Field: Zone Heating Design Supply Air Temperature Input Method
Field: Zone Heating Design Supply Air Temperature
Field: Zone Heating Design Supply Air Temperature Difference
Field: Heat Pump Coil Water Flow Mode
Field: Design Specification Outdoor Air Object Name
Field: Design Specification Zone Air Distribution Object Name
HVACTemplate:System:Unitary
Field: Name
Field: System Availability Schedule Name
Field: Control Zone or Thermostat Location Name
Field: Supply Fan Maximum Flow Rate
Field: Supply Fan Operating Mode Schedule Name
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Design Supply Air Temperature
Field: Cooling Coil Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Design Supply Air Temperature
Field: Heating Coil Capacity
Field: Gas Heating Coil Efficiency
Field: Gas Heating Coil Parasitic Electric Load
Field: Maximum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Schedule Name
Field: Economizer Type
Field: Economizer Lockout
Field: Economizer Upper Temperature Limit
Field: Economizer Lower Temperature Limit
Field: Economizer Upper Enthalpy Limit
Field: Economizer Maximum Limit Dewpoint Temperature
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Supply Fan Placement
Field: Night Cycle Control
Field: Night Cycle Control Zone Name
Field: Heat Recovery Type
Field: Sensible Heat Recovery Effectiveness
Field: Latent Heat Recovery Effectiveness
Field: Dehumidification Control Type
Field: Dehumidification Control Zone Name
Field: Dehumidification Setpoint
Field: Humidifier Type
Field: Humidifier Availability Schedule Name
Field: Humidifier Rated Capacity
Field: Humidifier Rated Electric Power
Field: Humidifier Control Zone Name
Field: Humidifier Setpoint
HVACTemplate:System:UnitaryHeatPump:AirToAir
Field: Name
Field: System Availability Schedule Name
Field: Control Zone or Thermostat Location Name
Field: Cooling Supply Air Flow Rate
Field: Heating Supply Air Flow Rate
Field: No Load Supply Air Flow Rate
Field: Supply Fan Operating Mode Schedule Name
Field: Supply Fan Placement
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Design Supply Air Temperature
Field: Cooling Coil Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heat Pump Heating Coil Type
Field: Heating Design Supply Air Temperature
Field: Heat Pump Heating Coil Availability Schedule Name
Field: Heat Pump Heating Coil Rated Capacity
Field: Heat Pump Heating Coil Rated COP
Field: Heat Pump Heating Minimum Outdoor Dry-Bulb Temperature
Field: Heat Pump Defrost Maximum Outdoor Dry-Bulb Temperature
Field: Heat Pump Defrost Strategy
Field: Heat Pump Defrost Control
Field: Heat Pump Defrost Time Period Fraction
Field: Supplemental Heating Coil Type
Field: Supplemental Heating Coil Availability Schedule Name
Field: Supplemental Heating Coil Capacity
Field: Supplemental Heating Coil Maximum Outdoor Dry-Bulb Temperature
Field: Supplemental Gas Heating Coil Efficiency
Field: Supplemental Gas Heating Coil Parasitic Electric Load
Field: Maximum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Schedule Name
Field: Economizer Type
Field: Economizer Lockout
Field: Economizer Maximum Limit Dry-Bulb Temperature
Field: Economizer Maximum Limit Enthalpy
Field: Economizer Maximum Limit Dewpoint Temperature
Field: Economizer Minimum Limit Dry-Bulb Temperature
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Night Cycle Control
Field: Night Cycle Control Zone Name
Field: Heat Recovery Type
Field: Sensible Heat Recovery Effectiveness
Field: Latent Heat Recovery Effectiveness
Field: Humidifier Type
Field: Humidifier Availability Schedule Name
Field: Humidifier Rated Capacity
Field: Humidifier Rated Electric Power
Field: Humidifier Control Zone Name
Field: Humidifier Setpoint
HVACTemplate:System:VAV
Field: Name
Field: System Availability Schedule Name
Field: Supply Fan Maximum Flow Rate
Field: Supply Fan Minimum Flow Rate
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Setpoint Schedule Name
Field: Cooling Coil Design Setpoint
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Coil Setpoint Schedule Name
Field: Heating Coil Design Setpoint
Field: Gas Heating Coil Efficiency
Field: Gas Heating Coil Parasitic Electric Load
Field: Preheat Coil Type
Field: Preheat Coil Availability Schedule Name
Field: Preheat Coil Setpoint Schedule Name
Field: Preheat Coil Design Setpoint
Field: Gas Preheat Coil Efficiency
Field: Gas Preheat Coil Parasitic Electric Load
Field: Maximum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Control Type
Field: Minimum Outdoor Air Schedule Name Name
Field: Economizer Type
Field: Economizer Lockout
Field: Economizer Upper Temperature Limit
Field: Economizer Lower Temperature Limit
Field: Economizer Upper Enthalpy Limit
Field: Economizer Maximum Limit Dewpoint Temperature
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Supply Fan Placement
Field: Supply Fan Part-Load Power Coefficients
Field: Night Cycle Control
Field: Night Cycle Control Zone Name
Field: Heat Recovery Type
Field: Sensible Heat Recovery Effectiveness
Field: Latent Heat Recovery Effectiveness
Field: Cooling Coil Setpoint Reset Type
Field: Heating Coil Setpoint Reset Type
Field: Dehumidification Control Type
Field: Dehumidification Control Zone Name
Field: Dehumidification Setpoint
Field: Humidifier Type
Field: Humidifier Availability Schedule Name
Field: Humidifier Rated Capacity
Field: Humidifier Rated Electric Power
Field: Humidifier Control Zone Name
Field: Humidifier Setpoint
Field: Sizing Option
HVACTemplate:System:PackagedVAV
Field: Name
Field: System Availability Schedule Name
Field: Supply Fan Maximum Flow Rate
Field: Supply Fan Minimum Flow Rate
Field: Supply Fan Placement
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Setpoint Schedule Name
Field: Cooling Coil Design Setpoint
Field: Cooling Coil Capacity
Field: Cooling Coil Rated Sensible Heat Ratio
Field: Cooling Coil Rated COP
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Coil Setpoint Schedule Name
Field: Heating Coil Design Setpoint
Field: Heating Coil Capacity
Field: Gas Heating Coil Efficiency
Field: Gas Heating Coil Parasitic Electric Load
Field: Maximum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Flow Rate
Field: Minimum Outdoor Air Control Type
Field: Minimum Outdoor Air Schedule Name
Field: Economizer Type
Field: Economizer Lockout
Field: Economizer Maximum Limit Dry-Bulb Temperature
Field: Economizer Maximum Limit Enthalpy
Field: Economizer Maximum Limit Dewpoint Temperature
Field: Economizer Minimum Limit Dry-Bulb Temperature
Field: Supply Plenum Name
Field: Return Plenum Name
Field: Supply Fan Part-Load Power Coefficients
Field: Night Cycle Control
Field: Night Cycle Control Zone Name
Field: Heat Recovery Type
Field: Sensible Heat Recovery Effectiveness
Field: Latent Heat Recovery Effectiveness
Field: Cooling Coil Setpoint Reset Type
Field: Heating Coil Setpoint Reset Type
Field: Dehumidification Control Type
Field: Dehumidification Control Zone Name
Field: Dehumidification Setpoint
Field: Humidifier Type
Field: Humidifier Availability Schedule Name
Field: Humidifier Rated Capacity
Field: Humidifier Rated Electric Power
Field: Humidifier Control Zone Name
Field: Humidifier Setpoint
Field: Sizing Option
HVACTemplate:System:DedicatedOutdoorAir
Field: Name
Field: System Availability Schedule Name
Field: Air Outlet Type
Field: Supply Fan Flow Rate
Field: Supply Fan Total Efficiency
Field: Supply Fan Delta Pressure
Field: Supply Fan Motor Efficiency
Field: Supply Fan Motor in Air Stream Fraction
Field: Supply Fan Placement
Field: Cooling Coil Type
Field: Cooling Coil Availability Schedule Name
Field: Cooling Coil Setpoint Control Type
Field: Cooling Coil Design Setpoint
Field: Cooling Coil Setpoint Schedule Name
Field: Cooling Coil Setpoint at Outdoor Dry-Bulb Low
Field: Cooling Coil Reset Outdoor Dry-Bulb Low
Field: Cooling Coil Setpoint at Outdoor Dry-Bulb High
Field: Cooling Coil Reset Outdoor Dry-Bulb High
Field: DX Cooling Coil Capacity
Field: DX Cooling Coil Rated Sensible Heat Ratio
Field: DX Cooling Coil Rated COP
Field: Heating Coil Type
Field: Heating Coil Availability Schedule Name
Field: Heating Coil Setpoint Control Type
Field: Heating Coil Design Setpoint
Field: Heating Coil Setpoint Schedule Name
Field: Heating Coil Setpoint at Outdoor Dry-Bulb Low
Field: Heating Coil Reset Outdoor Dry-Bulb Low
Field: Heating Coil Setpoint at Outdoor Dry-Bulb High
Field: Heating Coil Reset Outdoor Dry-Bulb High
Field: Gas Heating Coil Efficiency
Field: Gas Heating Coil Parasitic Electric Load
Field: Heat Recovery Type
Field: Heat Recovery Sensible Effectiveness []
Field: Heat Recovery Latent Effectiveness []
Field: Heat Recovery Heat Exchanger Type
Field: Heat Recovery Frost Control Type
Field: Dehumidification Control Type
Field: Dehumidification Setpoint
Field: Humidifier Type
Field: Humidifier Availability Schedule Name
Field: Humidifier Rated Capacity
Field: Humidifier Rated Electric Power
Field: Humidifier Setpoint
Field: Dehumidification Setpoint Schedule Name
Field: Humidifier Setpoint Schedule Name
HVACTemplate:Plant:ChilledWaterLoop
Field: Name
Field: Pump Schedule Name
Field: Pump Control Type
Field: Chiller Plant Operation Scheme Type
Field: Chiller Plant Equipment Operation Schemes Name
Field: Chilled Water Setpoint Schedule Name
Field: Chilled Water Design Setpoint
Field: Chilled Water Pump Configuration
Field: Primary Chilled Water Pump Rated Head
Field: Secondary Chilled Water Pump Rated Head
Field: Condenser Plant Operation Scheme Type
Field: Condenser Equipment Operation Schemes Name
Field: Condenser Water Temperature Control Type
Field: Condenser Water Setpoint Schedule Name
Field: Condenser Water Design Setpoint
Field: Condenser Water Pump Rated Head
Field: Chilled Water Setpoint Reset Type
Field: Chilled Water Setpoint at Outdoor Dry-Bulb Low
Field: Chilled Water Reset Outdoor Dry-Bulb Low
Field: Chilled Water Setpoint at Outdoor Dry-Bulb High
Field: Chilled Water Reset Outdoor Dry-Bulb High
Field: Chilled Water Primary Pump Type
Field: Chilled Water Secondary Pump Type
Field: Condenser Water Pump Type
Field: Chilled Water Supply Side Bypass Pipe
Field: Chilled Water Demand Side Bypass Pipe
Field: Condenser Water Supply Side Bypass Pipe
Field: Condenser Water Demand Side Bypass Pipe
Field: Fluid Type
Field: Loop Design Delta Temperature
Field: Minimum Outdoor Dry Bulb Temperature
Field: Chilled Water Load Distribution Scheme
Field: Condenser Water Load Distribution Scheme
HVACTemplate:Plant:Chiller
Field: Name
Field: Chiller Type
Field: Capacity
Field: Nominal COP
Field: Condenser Type
Field: Priority
Field: Sizing Factor
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Minimum Unloading Ratio
Field: Leaving Chilled Water Lower Temperature Limit
HVACTemplate:Plant:Chiller:ObjectReference
This object references a detailed chiller object and adds it to an HVACTemplate:Plant:ChilledWaterLoop. The user must create a complete detailed chiller object with all required curve or performance objects. The detailed chiller object is referenced by object type and name and the chiller will be automatically to the chilled water loop branches and equipment list.
Field: Name
Field: Chiller Object Type
Field: Chiller Name
Field: Priority
HVACTemplate:Plant:Tower
Field: Name
Field: Tower Type
Field: High-Speed Nominal Capacity
Field: High-Speed Fan Power
Field: Low-Speed Nominal Capacity
Field: Low-Speed Fan Power
Field: Free Convection Capacity
Field: Priority
HVACTemplate:Plant:Tower:ObjectReference
This object references a detailed cooling tower object and adds it to an HVACTemplate:Plant:ChilledWaterLoop or MixedWaterLoop. The user must create a complete detailed cooling tower object with all required curve or performance objects. The detailed cooling tower object is referenced by object type and name and the tower will be automatically to the chilled water loop or mixed water loop branches and equipment list.
Field: Name
Field: Cooling Tower Object Type
Field: Cooling Tower Name
Field: Priority
HVACTemplate:Plant:HotWaterLoop
Field: Name
Field: Pump Schedule Name
Field: Pump Control Type
Field: Hot Water Plant Operation Scheme Type
Field: Hot Water Plant Equipment Operation Schemes Name
Field: Hot Water Setpoint Schedule Name
Field: Hot Water Design Setpoint
Field: Hot Water Pump Configuration
Field: Hot Water Pump Rated Head
Field: Hot Water Setpoint Reset Type
Field: Hot Water Setpoint at Outdoor Dry Bulb Low
Field: Hot Water Reset Outdoor Dry Bulb Low
Field: Hot Water Setpoint at Outdoor Dry Bulb High
Field: Hot Water Reset Outdoor Dry Bulb High
Field: Hot Water Pump Type
Field: Supply Side Bypass Pipe
Field: Demand Side Bypass Pipe
Field: Fluid Type
Field: Loop Design Delta Temperature
Field: Maximum Outdoor Dry Bulb Temperature
Field: Load Distribution Scheme
HVACTemplate:Plant:Boiler
Fiel d: Name”field-boiler-type
Field: Capacity
Field: Efficiency
Field: Fuel Type
Field: Priority
Field: Sizing Factor
Field: Minimum Part Load Ratio
Field: Maximum Part Load Ratio
Field: Optimum Part Load Ratio
Field: Water Outlet Upper Temperature Limit
HVACTemplate:Plant:Boiler:ObjectReference
This object references a detailed boiler object and adds it to an HVACTemplate:Plant:HotWaterLoop or MixedWaterLoop. The user must create a complete detailed boiler object with all required curve or performance objects. The detailed boiler object is referenced by object type and name and the boiler will be automatically to the hot water or mixed water loop branches and equipment list.
Field: Name
Field: Boiler Object Type
Field: Boiler Name
Field: Priority
HVACTemplate:Plant:MixedWaterLoop
Field: Name
Field: Pump Schedule Name
Field: Pump Control Type
Field: Operation Scheme Type
Field: Equipment Operation Schemes Name
Field: High Temperature Setpoint Schedule Name
Field: High Temperature Design Setpoint
Field: Low Temperature Setpoint Schedule Name
Field: Low Temperature Design Setpoint
Field: Water Pump Configuration
Field: Water Pump Rated Head
Field: Water Pump Type
Field: Supply Side Bypass Pipe
Field: Demand Side Bypass Pipe
Field: Fluid Type
Field: Loop Design Delta Temperature
Field: Load Distribution Scheme
EnergyPlus Economics
Group – Economics
Introduction to Economics
Conceptual Framework – Variables and Hierarchy
UtilityCost:Tariff
Field: Name
Field: Output Meter Name
Field: Conversion Factor Choice
Field: Energy Conversion Factor
Field: Demand Conversion Factor
Field: Time of Use Period Schedule Name
Field: Season Schedule Name
Field: Month Schedule Name
Field: Demand Window Length
Field: Monthly Charge or Variable Name
Field: Minimum Monthly Charge or Variable Name
Field: Real Time Pricing Charge Schedule Name
Field: Customer Baseline Load Schedule Name
Field: Group Name
Field: Buy Or Sell
UtilityCost:Qualify
Field: Name
Field: Tariff Name
Field: Variable Name
Field: Qualify Type
Field: Threshold Value or Variable Name
Field: Season
Field: Threshold Test
Field: Number of Months
UtilityCost:Charge:Simple
Field: Charge Variable Name
Field: Tariff Name
Field: Source Variable
Field: Season
Field: Category Variable Name
Field: Cost per Unit Value or Variable Name
UtilityCost:Charge:Block
Field: Charge Variable Name
Field: Tariff Name
Field: Source Variable
Field: Season
Field: Category Variable Name
Field: Remaining Into Variable
Field: Block Size Multiplier Value or Variable Name
Field: Block Size 1 Value or Variable Name
Field: Block 1 Cost per Unit Value or Variable Name
UtilityCost:Ratchet
Field: Ratchet Variable Name
Field: Tariff Name
Field: Baseline Source Variable
Field: Adjustment Source Variable
Field: Season From
Field: Season To
Field: Multiplier Value or Variable Name
Field: Offset Value or Variable Name
UtilityCost:Variable
Field: Name
Field: Tariff Name
Field: Variable Type
Field: January through December Values
UtilityCost:Computation
Field: Name
Field: Tariff Name
Field: Compute Step N
UtilityCost:Tariff Examples
Example A – Flat Energy Charge
Example B – Block Energy Charge
Example C – Block Energy and Demand Charges
Example D - Seasonal Energy Charges with Minimum Charge
Example E – kWh/kW Energy Charges
Example F – Seasonal Time of Use Energy
Example G – Blocks within Blocks
Example H – Real Time Pricing
Example I – Selling and Net-Metering
UtilityCost:Tariff Reporting
Economic Results Summary Report
Complex Tariff Modeling
Operator: SUM (unlimited)
Operator: ADD (2)
Operator: MULTIPLY (2)
Operator: SUBTRACT (2)
Operator: DIVIDE (2)
Operator: ABSOLUTE (1)
Operator: INTEGER (1)
Operator: SIGN (1)
Operator: MAXIMUM (unlimited)
Operator: MINIMUM (unlimited)
Operator: EXCEEDS (2)
Operator: ANNUALMINIMUM (1)
Operator: ANNUALMAXIMUM (1)
Operator: ANNUALSUM (1)
Operator: ANNUALAVERAGE (1)
Operator: ANNUALOR (1)
Operator: ANNUALAND (1)
Operator: ANNUALMAXIMUMZERO (1)
Operator: ANNUALMINIMUMZERO (1)
Operator: IF (3)
Operator: GREATERTHAN (2)
Operator: GREATEREQUAL (2)
Operator: LESSTHAN (2)
Operator: LESSEQUAL (2)
Operator: EQUAL (2)
Operator: NOTEQUAL (2)
Operator: AND (2)
Operator: OR (2)
Operator: NOT (2)
Operator: FROM (Unlimited)
Cost Estimating
ComponentCost:LineItem
Field: Name
Field: Type
Field: Line Item Type
Field: Item Name
Field: Object End Use Key
Field: Cost per Each
Field: Cost per Area
Field: Cost per Unit of Output Capacity
Field: Cost per Unit of Output Capacity per COP
Field: Cost per Volume
Field: Cost per Volume Rate
Field: Cost per Energy per Temperature Difference
Field: Quantity
ComponentCost:Adjustments
Field: Miscellaneous Cost per Conditioned Area
Field: Design and Engineering Fees
Field: Contractor Fee
Field: Contingency
Field: Permits, Bonding and Insurance
Field: Commissioning Fee
Field: Regional Adjustment Factor
ComponentCost:Reference
Field: Reference Building Line Item Costs
Field: Reference Building Miscellaneous Cost per Conditioned Area
Field: Reference Building Design and Engineering Fees
Field: Reference Building Contractor Fee
Field: Reference Building Contingency
Field: Reference Building Permits, Bonding and Insurance
Field: Reference Building Commissioning Fee
Field: Reference Building Regional Adjustment Factor
Economics Cost Estimate Reporting
Life-Cycle Costing
LifeCycleCost:Parameters
Field: Name
Field: Discounting Convention
Field: Inflation Approach
Field: Real Discount Rate
Field: Nominal Discount Rate
Field: Inflation Rate
Field: Base Date Month
Field: Base Date Year
Field: Service Date Month
Field: Service Date Year
Field: Length of Study Period in Years
Field: Tax rate
Field: Depreciation Method
LifeCycleCost:RecurringCosts
Field: Name
Field: Category
Field: Cost
Field: Start of Costs
Field: Years From Start
Field: Months From Start
Field: Repeat Period Years
Field: Repeat Period Months
Field: Annual Escalation Rate
LifeCycleCost:NonrecurringCost
Field: Name
Field: Category
Field: Cost
Field: Start of Costs
Field: Years From Start
Field: Months From Start
LifeCycleCost:UsePriceEscalation
Field: Name
Field: Resource
Field: Escalation Start Year
Field: Escalation Start Month
Field: Year 1 Escalation
Field: Year n Escalation
LifeCycleCost:UseAdjustment
Field: Name
Field: Resource
Field: Year 1 multiplier
Field: Year N multiplier
CurrencyType
Field: Monetary Unit
Parametric Objects
Group – Parametrics
Expressions
Processing Order
Parametric:SetValueForRun
Field: Parameter Name
Field: Value for run n
Parametric:Logic
IF ENDIF Block
IF ELSE ENDIF Block
IF ELSEIF ELSE ENDIF Block
SELECT CASE DEFAULT ENDSELECT Block
ENABLE DISABLE
REMARK
OBJECT DEFINITION
Field: Name
Field: Parametric Logic Line n
Parametric:RunControl
Field: Name
Field: Perform run n
Parametric:FileNameSuffix
Field: Name
Field: Suffix for file name in run n
Input for Output
Group – Reports
Variable Dictionary Reports
Field: Key Field
Field: Sort Option
Variable Dictionary Report in IDF Format
Surface Reports
Output:Surfaces:List
Lines Data Report
Field: Report Specifications
Detailed Surface Data Report
Vertices Data Report
Detailed Surface Data With Vertices Report
View Factor Information Report
DecayCurvesfromZoneComponentLoads
Output:Surfaces:Drawing
DXF Surface Report
Field: Report Specifications 1
Field: Report Specifications 2
DXF Wire Frame Report
VRML Report
Field: Report Specifications 1
Field: Report Specifications 2
Output:Schedules
Field: Key Field
Output:Constructions
Constructions Report
Field: Details Type 1, Details Type 2
Materials Report
Output:DaylightFactors
Field: Reporting Days
Output:EnergyManagementSystem
Field: Actuator Availability Dictionary Reporting
Field: Internal Variable Availability Dictionary Reporting
Field: EnergyPlus Runtime Language Debug Output Level
OutputControl:SurfaceColorScheme
Field: Name
Field Set: Drawing Element Type and Colorr
Field: Drawing Element <#> Type
Field: Color for Drawing Element <#>
OutputControl:ReportingTolerances
Field: Tolerance for Time Heating Setpoint Not Met
Field: Tolerance for Time Cooling Setpoint Not Met
Output:Variable
Field: Key Value
Field: Variable Name
Field: Reporting Frequency
Field: Schedule Name
Output:Meter and Output:Meter:MeterFileOnly
Output:Meter:Cumulative and Output:Meter:Cumulative:MeterFileOnly
Field: Name
Other Resource Types
Additional End Use Types Only Used for EnergyTransfer
Field: Reporting Frequency
Meter Details File (eplusout.mtd)
Output:EnvironmentalImpactFactors
Field: Reporting Frequency
EnvironmentalImpactFactors
Field: District Heating Efficiency
Field: Disctrict Cooling COP
Field: Steam Conversion Efficiency
Field: Total Carbon Equivalent Emission Factor From N2O
Field: Total Carbon Equivalent Emission Factor From CH4
Field: Total Carbon Equivalent Emission Factor From CO2
FuelFactors
Field: Existing Fuel Resource Name
Field: Units of Measure
Field: Energy per Unit Factor
Field: Source Energy Factor
Field: Source Energy Schedule Name
Field: CO2 Emission Factor
Field: CO2 Emission Factor Schedule Name
Field: CO Emission Factor
Field: CO Emission Factor Schedule Name
Field: CH4 Emission Factor
Field: CH4 Emission Factor Schedule Name
Field: NOx Emission Factor
Field: NOx Emission Factor Schedule Name
Field: N2O Emission Factor
Field: N2O Emission Factor Schedule Name
Field: SO2 Emission Factor
Field: SO2 Emission Factor Schedule Name
Field: PM Emission Factor
Field: PM Emission Factor Schedule Name
Field: PM10 Emission Factor
Field: PM10 Emission Factor Schedule Name
Field: PM2.5 Emission Factor
Field: PM2.5 Emission Factor Schedule Name
Field: NH3 Emission Factor
Field: NH3 Emission Factor Schedule Name
Field: NMVOC Emission Factor
Field: NMVOC Emission Factor Schedule Name
Field: Hg Emission Factor
Field: Hg Emission Factor Schedule Name
Field: Pb Emission Factor
Field: Pb Emission Factor Schedule Name
Field: Water Emission Factor
Field: Water Emission Factor Schedule Name
Field: Nuclear High Level Emission Factor
Field: Nuclear High Level Emission Factor Schedule Name
Field: Nuclear Low Level Emission factor
Field: Nuclear Low Level Emission Factor Schedule Name
Environmental Pollution Impact Outputs
Environmental Impact Electricity Source Energy [J]
Environmental Impact Purchased Electricity Source Energy [J]
Environmental Impact Surplus Sold Electricity Source [J]
Environmental Impact Natural Gas Source Energy [J]
Environmental Impact Fuel Oil #2 Source Energy [J]
Environmental Impact Fuel Oil #1 Source Energy [J]
Environmental Impact Coal Source Energy [J]
Environmental Impact Gasoline Source Energy [J]
Environmental Impact Propane Source Energy [J]
Environmental Impact Diesel Source Energy [J]
Environmental Impact OtherFuel1 Source Energy [J]
Environmental Impact OtherFuel2 Source Energy [J]
Environmental Impact Electricity CO2 Emissions Mass [kg]
Environmental Impact Natural Gas CO2 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 CO2 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 CO2 Emissions Mass [kg]
Environmental Impact Coal CO2 Emissions Mass [kg]
Environmental Impact Gasoline CO2 Emissions Mass [kg]
Environmental Impact Propane CO2 Emissions Mass [kg]
Environmental Impact Diesel CO2 Emissions Mass [kg]
Environmental Impact OtherFuel1 CO2 Emissions Mass [kg]
Environmental Impact OtherFuel2 CO2 Emissions Mass [kg]
Environmental Impact Electricity CO Emissions Mass [kg]
Environmental Impact Natural Gas CO Emissions Mass [kg]
Environmental Impact Fuel Oil #2 CO Emissions Mass [kg]
Environmental Impact Fuel Oil #1 CO Emissions Mass [kg]
Environmental Impact Coal CO Emissions Mass [kg]
Environmental Impact Gasoline CO Emissions Mass [kg]
Environmental Impact Propane CO Emissions Mass [kg]
Environmental Impact Diesel CO Emissions Mass [kg]
Environmental Impact OtherFuel1 CO Emissions Mass [kg]
Environmental Impact OtherFuel2 CO Emissions Mass [kg]
Environmental Impact Electricity CH4 Emissions Mass [kg]
Environmental Impact Natural Gas CH4 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 CH4 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 CH4 Emissions Mass [kg]
Environmental Impact Coal CH4 Emissions Mass [kg]
Environmental Impact Gasoline CH4 Emissions Mass [kg]
Environmental Impact Propane CH4 Emissions Mass [kg]
Environmental Impact Diesel CH4 Emissions Mass [kg]
Environmental Impact OtherFuel1 CH4 Emissions Mass [kg]
Environmental Impact OtherFuel2 CH4 Emissions Mass [kg]
Environmental Impact Electricity NOx Emissions Mass [kg]
Environmental Impact Natural Gas NOx Emissions Mass [kg]
Environmental Impact Fuel Oil #2 NOx Emissions Mass [kg]
Environmental Impact Fuel Oil #1 NOx Emissions Mass [kg]
Environmental Impact Coal NOx Emissions Mass [kg]
Environmental Impact Gasoline NOx Emissions Mass [kg]
Environmental Impact Propane NOx Emissions Mass [kg]
Environmental Impact Diesel NOx Emissions Mass [kg]
Environmental Impact OtherFuel1 NOx Emissions Mass [kg]
Environmental Impact OtherFuel2 NOx Emissions Mass [kg]
Environmental Impact Electricity N2O Emissions Mass [kg]
Environmental Impact Natural Gas N2O Emissions Mass [kg]
Environmental Impact Fuel Oil #2 N2O Emissions Mass [kg]
Environmental Impact Fuel Oil #1 N2O Emissions Mass [kg]
Environmental Impact Coal N2O Emissions Mass [kg]
Environmental Impact Gasoline N2O Emissions Mass [kg]
Environmental Impact Propane N2O Emissions Mass [kg]
Environmental Impact Diesel N2O Emissions Mass [kg]
Environmental Impact OtherFuel1 N2O Emissions Mass [kg]
Environmental Impact OtherFuel2 N2O Emissions Mass [kg]
Environmental Impact Electricity SO2 Emissions Mass [kg]
Environmental Impact Natural Gas SO2 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 SO2 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 SO2 Emissions Mass [kg]
Environmental Impact Coal SO2 Emissions Mass [kg]
Environmental Impact Gasoline SO2 Emissions Mass [kg]
Environmental Impact Propane SO2 Emissions Mass [kg]
Environmental Impact Diesel SO2 Emissions Mass [kg]
Environmental Impact OtherFuel1 SO2 Emissions Mass [kg]
Environmental Impact OtherFuel2 SO2 Emissions Mass [kg]
Environmental Impact Electricity PM Emissions Mass [kg]
Environmental Impact Natural Gas PM Emissions Mass [kg]
Environmental Impact Fuel Oil #2 PM Emissions Mass [kg]
Environmental Impact Fuel Oil #1 PM Emissions Mass [kg]
Environmental Impact Coal PM Emissions Mass [kg]
Environmental Impact Gasoline PM Emissions Mass [kg]
Environmental Impact Propane PM Emissions Mass [kg]
Environmental Impact Diesel PM Emissions Mass [kg]
Environmental Impact OtherFuel1 PM Emissions Mass [kg]
Environmental Impact OtherFuel2 PM Emissions Mass [kg]
Environmental Impact Electricity PM10 Emissions Mass [kg]
Environmental Impact Natural Gas PM10 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 PM10 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 PM10 Emissions Mass [kg]
Environmental Impact Coal PM10 Emissions Mass [kg]
Environmental Impact Gasoline PM10 Emissions Mass [kg]
Environmental Impact Propane PM10 Emissions Mass [kg]
Environmental Impact Diesel PM10 Emissions Mass [kg]
Environmental Impact OtherFuel1 PM10 Emissions Mass [kg]
Environmental Impact OtherFuel2 PM10 Emissions Mass [kg]
Environmental Impact Electricity PM2.5 Emissions Mass [kg]
Environmental Impact Natural Gas PM2.5 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 PM2.5 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 PM2.5 Emissions Mass [kg]
Environmental Impact Coal PM2.5 Emissions Mass [kg]
Environmental Impact Gasoline PM2.5 Emissions Mass [kg]
Environmental Impact Propane PM2.5 Emissions Mass [kg]
Environmental Impact Diesel PM2.5 Emissions Mass [kg]
Environmental Impact OtherFuel1 PM2.5 Emissions Mass [kg]
Environmental Impact OtherFuel2 PM2.5 Emissions Mass [kg]
Environmental Impact Electricity NH3 Emissions Mass [kg]
Environmental Impact Natural Gas NH3 Emissions Mass [kg]
Environmental Impact Fuel Oil #2 NH3 Emissions Mass [kg]
Environmental Impact Fuel Oil #1 NH3 Emissions Mass [kg]
Environmental Impact Coal NH3 Emissions Mass [kg]
Environmental Impact Gasoline NH3 Emissions Mass [kg]
Environmental Impact Propane NH3 Emissions Mass [kg]
Environmental Impact Diesel NH3 Emissions Mass [kg]
Environmental Impact OtherFuel1 NH3 Emissions Mass [kg]
Environmental Impact OtherFuel2 NH3 Emissions Mass [kg]
Environmental Impact Electricity NMVOC Emissions Mass [kg]
Environmental Impact Natural Gas NMVOC Emissions Mass [kg]
Environmental Impact Fuel Oil #2 NMVOC Emissions Mass [kg]
Environmental Impact Fuel Oil #1 NMVOC Emissions Mass [kg]
Environmental Impact Coal NMVOC Emissions Mass [kg]
Environmental Impact Gasoline NMVOC Emissions Mass [kg]
Environmental Impact Propane NMVOC Emissions Mass [kg]
Environmental Impact Diesel NMVOC Emissions Mass [kg]
Environmental Impact OtherFuel1 NMVOC Emissions Mass [kg]
Environmental Impact OtherFuel2 NMVOC Emissions Mass [kg]
Environmental Impact Electricity Hg Emissions Mass [kg]
Environmental Impact Natural Gas Hg Emissions Mass [kg]
Environmental Impact Fuel Oil #2 Hg Emissions Mass [kg]
Environmental Impact Fuel Oil #1 Hg Emissions Mass [kg]
Environmental Impact Coal Hg Emissions Mass [kg]
Environmental Impact Gasoline Hg Emissions Mass [kg]
Environmental Impact Propane Hg Emissions Mass [kg]
Environmental Impact Diesel Hg Emissions Mass [kg]
Environmental Impact OtherFuel1 Hg Emissions Mass [kg]
Environmental Impact OtherFuel2 Hg Emissions Mass [kg]
Environmental Impact Electricity Pb Emissions Mass [kg]
Environmental Impact Natural Gas Pb Emissions Mass [kg]
Environmental Impact Fuel Oil #2 Pb Emissions Mass [kg]
Environmental Impact Fuel Oil #1 Pb Emissions Mass [kg]
Environmental Impact Coal Pb Emissions Mass [kg]
Environmental Impact Gasoline Pb Emissions Mass [kg]
Environmental Impact Propane Pb Emissions Mass [kg]
Environmental Impact Diesel Pb Emissions Mass [kg]
Environmental Impact OtherFuel1 Pb Emissions Mass [kg]
Environmental Impact OtherFuel2 Pb Emissions Mass [kg]
Environmental Impact Electricity Water Consumption Volume [L]
Environmental Impact Natural Gas Water Consumption Volume [L]
Environmental Impact Fuel Oil #2 Water Consumption Volume [L]
Environmental Impact Fuel Oil #1 Water Consumption Volume [L]
Environmental Impact Coal Water Consumption Volume [L]
Environmental Impact Gasoline Water Consumption Volume [L]
Environmental Impact Propane Water Consumption Volume [L]
Environmental Impact Diesel Water Consumption Volume [L]
Environmental Impact OtherFuel1 Water Consumption Volume [L]
Environmental Impact OtherFuel2 Water Consumption Volume [L]
Environmental Impact Electricity Nuclear High Level Waste Mass [kg]
Nuclear High Level Waste From Natural Gas [kg]
Environmental Impact Fuel Oil #2 Nuclear High Level Waste Mass [kg]
Environmental Impact Fuel Oil #1 Nuclear High Level Waste Mass [kg]
Environmental Impact Coal Nuclear High Level Waste Mass [kg]
Environmental Impact Gasoline Nuclear High Level Waste Mass [kg]
Environmental Impact Propane Nuclear High Level Waste Mass [kg]
Environmental Impact Diesel Nuclear High Level Waste Mass [kg]
Environmental Impact OtherFuel1 Nuclear High Level Waste Mass [kg]
Environmental Impact OtherFuel2 Nuclear High Level Waste Mass [kg]
Environmental Impact Electricity Nuclear Low Level Waste Volume [m3]
Environmental Impact Natural Gas Nuclear Low Level Waste Volume [m3]
Environmental Impact Fuel Oil #2 Nuclear Low Level Waste Volume [m3]
Environmental Impact Fuel Oil #1 Nuclear Low Level Waste Volume [m3]
Environmental Impact Coal Nuclear Low Level Waste Volume [m3]
Environmental Impact Gasoline Nuclear Low Level Waste Volume [m3]
Environmental Impact Propane Nuclear Low Level Waste Volume [m3]
Environmental Impact Diesel Nuclear Low Level Waste Volume [m3]
Environmental Impact OtherFuel1 Nuclear Low Level Waste Volume [m3]
Environmental Impact OtherFuel2 Nuclear Low Level Waste Volume [m3]
Environmental Impact Total N2O Emissions Carbon Equivalent Mass [kg]
Environmental Impact Total CH4 Emissions Carbon Equivalent Mass [kg]
Environmental Impact Total CO2 Emissions Carbon Equivalent Mass [kg]
Output:SQLite
Field: Option
Output
Using ReadVarsESO
Creating Charts and Spreadsheet files from Output Variables
Standard Output Reports
Output:Table:TimeBins
Field: Key Value
Field: Variable Name
Field: Interval Start
Field: Interval Size
Field: Interval Count
Field: Schedule Name
Field: Variable Type
Output:Table:Monthly
Field: Name
Field: Digits After Decimal
Field Set: Variable or Meter and Aggregation Type
Field: Variable or Meter <#> Name
Field: Aggregation Type for Variable or Meter <#>
Output:Table:SummaryReports
Field: Report <#> Name
Predefined Annual Summary Reports
Annual Building Utility Performance Summary (sometimes called ABUPS)
Input Verification and Results Summary (or IVRS)
Source Energy End Use Components Summary
Climatic Data Summary
Envelope Summary
Surface Shadowing Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Component Sizing Summary
Outdoor Air Summary
System Summary
Adaptive Comfort Summary
Sensible Heat Gain Summary
Zone Component Load Summary
Standard 62.1 Summary
Energy Meters Summary
Predefined Monthly Summary Reports
ZoneCoolingSummaryMonthly
ZoneHeatingSummaryMonthly
ZoneElectricSummaryMonthly
SpaceGainsMonthly
PeakSpaceGainsMonthly
SpaceGainComponentsAtCoolingPeakMonthly
EnergyConsumptionElectricityNaturalGasMonthly
EnergyConsumptionElectricityGeneratedPropaneMonthly
EnergyConsumptionDieselFuel OilMonthly
EnergyConsumptionDisctrictHeatingCoolingMonthly
EnergyConsumptionCoalGasolineMonthly
EnergyConsumptionOtherFuelsMonthly
EndUseEnergyConsumptionElectricityMonthly
EndUseEnergyConsumptionNaturalGasMonthly
EndUseEnergyConsumptionDieselMonthly
EndUseEnergyConsumptionFuelOilMonthly
EndUseEnergyConsumptionCoalMonthly
EndUseEnergyConsumptionPropaneMonthly
EndUseEnergyConsumptionGasolineMonthly
EndUseEnergyConsumptionOtherFuelsMonthly
PeakEnergyEndUseElectricityPart1Monthly
PeakEnergyEndUseElectricityPart2Monthly
ElectricComponentsOfPeakDemandMonthly
PeakEnergyEndUseNaturalGasMonthly
PeakEnergyEndUseDieselMonthly
PeakEnergyEndUseFuelOilMonthly
PeakEnergyEndUseCoalMonthly
PeakEnergyEndUsePropaneMonthly
PeakEnergyEndUseGasolineMonthly
PeakEnergyEndUseOtherFuelsMonthly
SetpointsNotMetWithTemperaturesMonthly
ComfortReportSimple55Monthly
UnglazedTranspiredSolarCollectorSummaryMonthly
OccupantComfortDataSummaryMonthly
Chille ReportMonthly
TowerReportMonthly
BoilerReportMonthly
DXReportMonthly
WindowReportMonthly
WindowEnergyReportMonthly
WindowZoneSummaryMonthly
WindowEnergyZoneSummaryMonthly
AverageOutdoorConditionsMonthly
OutdoorConditionsMaximumDryBulbMonthly
OutdoorConditionsMinimumDryBulbMonthly
OutdoorConditionsMaximumWetBulbMonthly
OutdoorConditionsMaximumDewPointMonthly
OutdoorGroundConditionsMonthly
WindowACReportMonthly
WaterHeaterReportMonthly
GeneratorReportMonthly
DaylightingReportMonthly
CoilReportMonthly
PlantLoopDemandReportMonthly
FanReportMonthly
PumpReportMonthly
CondLoopDemandReportMonthly
ZoneTemperatureOscillationReportMonthly
AirLoopSystemEnergyAndWaterUseMonthly
AirLoopSystemComponentLoadsMonthly
AirLoopSystemComponentEnergyUseMonthly
MechanicalVentilationLoadsMonthly
Zone Mechanical Ventilation Air Changes per Hour (SumOrAverage)
OutputControl:Table:Style
Field: Column Separator
Field: Unit Conversion
Weather Data
Missing Weather File Data
Weather Data Hourly Interpolation
Weather File Data Reporting (errors) during Simulation
Running EnergyPlus
Energy+.ini
Errors
EnergyPlus Execution Time
Reducing Run Time Tips
Appendix A. Units and Abbreviations
Standard EnergyPlus Conditions
Standard Temperature and Pressure
Standard EnergyPlus Units
Copyright © 2009-2026 Big Ladder Software LLC. All rights reserved. The Big Ladder name and logo are trademarks of Big Ladder Software LLC.